![CMOS-PCB\nPOWER\nPLAST\nCPU 电容器\nINPUT RANGE\n34 VTD/DC\nGEN HCT SHAP\nPCMD 2.11](.cps-h640-48-datasheet-en-20170409-v1/6b1a1fb81005b7935e2a1109ac44d33c2d9023966df54a75056c5d316e502337.jpg)

# Features

PICMG® 2.11 CompactPCI® Power Interface compliant
6U CompactPCI® 8HP form factor
PICMG® 2.11 47-pin CompactPCI® in-rack power module interface
400 W DC output
Active PFC (Power Factor Correction) meets IEC1000-3-2 Harmonic Correction
Internal OR-ing Diodes for N+1 redundancy
Hot swappable
Active current sharing
EN 55022 & FCC Class A
Supports remote ON/OFF
Supports power failure signal & degradation signal

Specifications

<table><tr><td>Model Name</td><td>cPS-H640/AC</td><td>cPS-H640/48</td></tr><tr><td>PICMG Standards</td><td colspan="2">PICMG® 2.11 CompactPCI 47-pin Power Interface compliant</td></tr><tr><td>Form Factor</td><td colspan="2">6U cPCI (233.33 x 160 mm), 2-slot (8HP) wide</td></tr><tr><td>Input Voltage</td><td>100-240 10% V AC</td><td>36-72 V DC</td></tr><tr><td>Input Frequency</td><td>50-60 5% Hz</td><td>DC</td></tr><tr><td>Input Current</td><td>5.1 A @115 V AC / 2.5 A @ 230 V AC</td><td>12A @ 48 V DC</td></tr><tr><td>Inrush Current</td><td>&lt; 30 A @230 V AC</td><td>N/A</td></tr><tr><td rowspan="2">Power Factor Correction(PFC, only for AC)</td><td colspan="2">Typical 0.97-0.99</td></tr><tr><td colspan="2">Meets Harmonic Correction IEC1000-3-2</td></tr><tr><td rowspan="5">Output Voltage/Current</td><td colspan="2">5 V: Typ. 40.0 A, Max. 50.0 A</td></tr><tr><td colspan="2">3.3 V: Typ. 20.0 A, Max. 40.0 A</td></tr><tr><td colspan="2">+12 V: Typ. 10.0 A, Max. 15.0 A</td></tr><tr><td colspan="2">-12 V: Typ. 2.0 A, Max 5.0 A</td></tr><tr><td colspan="2">** Max. load is the continuous operating load of each rail individually. The Max. load of each rail cannot be drawn from all outputs simultaneously.</td></tr><tr><td>Output Voltage Minimum Load</td><td colspan="2">1.0 A @ +5 V</td></tr><tr><td>Output Wattage</td><td colspan="2">Typical 400 W continuous</td></tr><tr><td>Line Regulation</td><td colspan="2">Typical 0.1%</td></tr><tr><td>Load Regulation</td><td colspan="2">Typical 1-3%</td></tr><tr><td>Ripple</td><td colspan="2">50 mV @ +5 V and 3.3 V outputs, 120 mV @ +12V and -12V outputs</td></tr><tr><td>Hold-up Time</td><td colspan="2">10 ms after power fail signal</td></tr><tr><td>Efficiency</td><td colspan="2">Typical 79-83%</td></tr><tr><td>Output voltage sense and current sharing</td><td colspan="2">Available at 5 V , 3.3 V and +12 V outputs</td></tr><tr><td>N+1 Redundancy</td><td colspan="2">Installed with internal OR-ing diodes at all outputs for N+1 redundancy operation</td></tr><tr><td>Remote ON/OFF</td><td colspan="2">Available at [INH#] &amp; [EN#]</td></tr></table>

<table><tr><td>Power Failure Signal</td><td colspan="2">Available at [FAL#] pin</td></tr><tr><td>Power Degradation Signal</td><td colspan="2">Available at [DEG#] pin</td></tr><tr><td rowspan="4">Protections</td><td colspan="2">Over Temperature Protection (OTP): 70°C</td></tr><tr><td colspan="2">Over Current Protection (OCP): Installed at each rail</td></tr><tr><td colspan="2">Over Load Protection (OLP): Typical 120% max. load, fully protected against output overload or short circuit.</td></tr><tr><td colspan="2">Over Voltage Protection (OVP): Built-in at all outputs</td></tr><tr><td rowspan="2">Status LED</td><td colspan="2">&lt; Green LED &gt; [POWER] means valid input voltage</td></tr><tr><td colspan="2">&lt; Amber LED &gt; [FAULT] means a critical fault</td></tr><tr><td>Earth Leakage</td><td>&lt; 0.9mA @ 230 V AC &gt;</td><td>N/A</td></tr><tr><td>Operating Temp.</td><td colspan="2">0°C to 70°C (0°C to +40°C at full load with specified air flow. De-rates linearly to 50% at +70°C.)</td></tr><tr><td>Storage Temp.</td><td colspan="2">-20°C to +85°C</td></tr><tr><td>Humidity</td><td colspan="2">20% to 90% non-condensing</td></tr><tr><td>Shock</td><td colspan="2">15 G peak-to-peak, 11 ms duration, non-operation</td></tr><tr><td>Vibration</td><td colspan="2">Operation: 1.88 Grms, 5-500 Hz, each axis</td></tr><tr><td>Cooling Requirement</td><td colspan="2">Minimum 20 CFM airflow is required for typical full rating power</td></tr><tr><td>Compliance</td><td colspan="2">IEC950, EN 55022, FCC Class A, IEC60950 Class I</td></tr></table>

Ordering Information

<table><tr><td>Model Number</td><td>Description/Configuration</td></tr><tr><td>cPS-H640/AC</td><td>PICMG® 2.11 47-Pin Hot-Swap Redundant 6U CompactPCI 8HP 400 W Power Module with Universal AC Input</td></tr><tr><td>cPS-H640/48</td><td>PICMG® 2.11 47-Pin Hot-Swap Redundant 6U CompactPCI 8HP 400 W Power Module with 36-72 V DC Input</td></tr></table>
[🔗 Link to the original document](.cps-h640-48-datasheet-en-20170409-v1/cps-h640-48-datasheet-en-20170409-v1.pdf)