# ND-6058

28-CH PPI Module
![ADLINK\nGREEN\nRoHS Compla\nNO. 8008\nUDRAM](.nd-6058-datasheet-1/609767fba734933dcd5c0a89a528511518f6a63f57adcf4ac2e8c12f6ef6a33b.jpg)

# Programmable I/O

■	8255 programmable peripheral interface mode 0 emulation
■	Channel: 24
■	Input Signal • TTL level
■	Internal Pull-Up Resistor: 10 kΩ
■	Maximum Current: 0.5 mA
■	Output Signal • TTL level

# Digital Input

■	Channels: 4
■	TTL level

# Power

■	Requirement: unregulated +10 V to +30 VDC
■	Power Consumption:1.488 W typical

# Connector

■	50-pin female SCSI II

# ND-6063

8-CH Relay Output Module
![ADLINK\nGREEN\nRoHS Compliance\nUdAM\nAD-3003\n100mm](.nd-6058-datasheet-1/1976b0ec3d8b4ef358f7937ca349dc6917082cf9f6c2390ae17ed0226727a400.jpg)

# Relay Output

■	Channels: 8 independent relay outputs
■	Output Type: 8 form A
■	Contact Rating

• DC 1 A / 30 V

• ON/OFF interval time: 3 ms (at 20°C)

■	Internal Insulation
■	Resistance: 1000 MΩ @ 500 VDC
■	Expected Life: 2 x 105

(1 A 30 VDC resistive at 20 cpm)

# Power

■	Requirement: unregulated +10 V to +30 VDC
■	Power Consumption: 1.416 W typical

# ND-6067

8-CH AC Relay Output Module
![ADLINK\nGREEN\nRoHS Complia\nUdPM\nAD-30007\n100μs](.nd-6058-datasheet-1/71a75b6d2ed16a452fbf6bbae37395688ee18a9df43279611c8dd97ff19d3dd0.jpg)

# Relay Output

■	Channels: 5 independent relay outputs and 3 common source replay outputs
■	Output type: 8 form A
■	Contact rating:

• AC 3 A / 250 V

• DC 3 A / 30 V

■	ON/OFF time interval: 6 ms/3 ms
• Operate time: approx. 6 ms
• Release time: approx. 3 ms
■	Insulation resistance: 1000 MΩ minimum (at 500 VDC)
■	Expected Life: 2 x 105 (3 A 250 VAC, 3 A 30 VDC at 20 cpm)

# Power

■	Power Requirement: +10 V to +30 VDC Unregulated with against power reversal
■	Power Consumption: 1.392 W typical

# ND-6060

Relay Output & Digital Input Module
![ADLINK\nGREEN\nRoHS Compliance\nNo. 3400\nU-DRAM](.nd-6058-datasheet-1/dfca2dda4ea95cc8247ad9717df7d16cd0bf3e620dd931c0ca2bd4b137c2a0db.jpg)

# Relay Output

■	 Channels: 4 relay outputs

■	 Output Type: 2 form C and 2 form A

■	 Contact Rating:

• DC 2A / 30 V

■	 ON/OFF Interval Time: 3 ms

■	 Internal Insulation Resistance:

1000 MΩ @ 500 VDC

■	 Expected Life: 2 x105
(1 A 30 VDC resistive at 20 cpm)
■	 Programmable output polarity
■	 Programmable output power on/safety state

# Digital Input

■	 Channels: 4
■	 Common External Voltage: +24 V
■	 Current Limit Resistor: 2.2 kΩ
■	 Isolation Voltage: 5000 VRMS
■	 Input Type: dry contact
■	 Programmable input polarity

# Power

■	 Requirement: unregulated +10 V to +30 VDC
■	 Power Consumption: 0.84 W typical

# ND-6080

2-CH Counter/Frequency Input Module
![ADLINK\nGREEN\nRoHS Compliant\nUDRAM](.nd-6058-datasheet-1/dd5e10b1b7a8324918aa24e76e54c3f8caf485cba3102eb543577625612fce85.jpg)

# Counter Inputs

■	Channels: Two independent 32-bit counter
■	Input Frequency: 20 KHz max.
■	Input Mode: isolated or non-isolated
■	Isolation Voltage: 5000 VRMS
■	Isolation Input Level

• Logical level 0: +1 V max

• Logical level 1: 3.5 V to 30 V

■	Current Limit Resistor: 1.2 kΩ

■	Non-isolated Input Level programmable threshold

• Logical l level 0: 0 V to +5 V
(default = 0.8 V)
• Logical level 1: 0 V to +5 V (default = 2.4 V)

■	Input Pulse Width: > 5 μs
■	Max Count: 4,294,967,295 (32-bit)

■	Programmable Digital Noise Filter: 4 μs to 1.02 ms
■	Alarm: alarm comparator on each counter

# Frequency Measurement

■	Range: 1 Hz to 20 KHz
■	Programmable built-in gate time: 1.0 / 0.1 s

# Digital Output

■	Channels: 2
■	Open collector to 30 V, 30 mA max. load

# Power

■	Requirement: unregulated +10 V to +30 VDC
■	Power Consumption: 2.016 W