![Front view of a blue industrial control unit with multiple drive bays and indicator lights (no visible text or labels)](.pxis-2719a-datasheet-en-1/3fd88f0744664932afc867b7f11e4f843585256a5a0b6d7b4595f6c86121b69b.jpg)

# Introduction

The ADLINK PXIS-2719A is a 3U PXI chassis with advanced features, including:

• Innovative cooling solution, delivering efficient and uniform heat dissipation
• Superior stability within an extended temperature range
• Intelligent chassis management providing dynamic monitoring and management of fan speed, system voltage, and internal temperature
• Remote management via standard RS-232 monitoring port

The PXIS-2719A is compliant with PXI and CompactPCI specifications and provides one system slot and eighteen peripheral slots. It is designed to meet or exceed application requirements with maximum slot capacity, extended operating temperature range, and superior heat dissipation in a lightweight and robust design.

The PXIS-2719A includes an Industrial-grade 600 W AC power supply to provide ample reliable power to the entire system. The PXIS-2719A is designed with an external 10 MHz reference clock input, front panel LED indicators, and easy-access PXI/CompactPCI slots with card guides for convenient installation and use. With innovative features and robust design, the PXIS-2719A is a clear leader for PXI platform-based test and measurement applications.

# Features

■ PXI Hardware Specification Rev. 2.2 compliant
■ Rack-mountable 19-slot PXI chassis with one system slot and eighteen PXI/CompactPCI peripheral slots
■ Advanced forced-cooling mechanism for efficient and uniform heat dissipation
■ External 10 MHz reference clock input via BNC connector
■ 0°C to 55°C extended operating temperature range
■ Intelligent chassis monitoring/control
• Automatic fan speed control
• Chassis status monitoring and exporting
• Remote chassis power on/off control
■ 600 W industrial-grade AC power supply
■ Power, temperature and fan monitoring LEDs

# Highlights

# Innovative Cooling Mechanism

The ADLINK PXIS-2719A features an innovative design for heat dissipation. The cooling fans are placed in the rear section of the chassis where cool air is drawn in through apertures on the bottom and exhausted through the back. This new design provides uniform airflow for each PXI slot and exceptional cooling capability. When the chassis is installed, the design minimizes intake of hot air from the rear where other devices exhaust, while maintaining a steady temperature inside the chassis.

# ■	Intelligent Chassis Management

The PXIS-2719A has a built-in control board monitors and manages chassis status, including internal temperature, fan speed, and voltages. Using the RS-232 monitoring port, the chassis status information can be exported to another computer for remote management. The control board can also accept commands from the remote system to allow remote power on/off and fan speed control of the PXIS-2719A chassis.

# Flexible Rack-mount Design

An optional rack-mount kit provides flexible installation of the PXIS-2719A. By adjusting the position of rack-mount bracket, the PXIS-2719A can be recessed in a cabinet rack up to 10 centimeters to accommodate external mechanical parts on the front side, such as complicated connectors/ wires and mass interconnect modules.

![3D diagram of a transparent container with internal flow arrows and water channels, no text or symbols present](.pxis-2719a-datasheet-en-1/274225d2259eed215c9d531f14101eb63935b31e86d0d2cd4c72aa8dc81c148f.jpg)

![Front view of a server rack with three fans and a small indicator button (no visible text or symbols)](.pxis-2719a-datasheet-en-1/dd9906b9cd0f740893acdd9a182f465b9e4cafa8fe16fd61253aeb2dbc1a39f1.jpg)

Remote Monitoring Port

![3D rendering of a white rectangular electronic device with blue trim and red indicator lights, no visible text or symbols](.pxis-2719a-datasheet-en-1/0d97dbfc2394e52d48f4cf2497588863a87a5672612716155dfbd6d1679a304f.jpg)

# Specifications

# Power Supply

■ AC Input

• Input voltage range: 85 to 264 VAC full range
• Input voltage frequency: 47 to 63 Hz

■ DC Output

• Maximum total usable power is 600 W

<table><tr><td>VDC</td><td>Maximum</td><td>Load Regulation</td><td>Maximum Ripple &amp; Noise</td></tr><tr><td>+5 V</td><td>45.0 A</td><td>±3%</td><td>20 mV</td></tr><tr><td>+12 V</td><td>15.0 A</td><td>±3%</td><td>50 mV</td></tr><tr><td>+3.3 V</td><td>42.0 A</td><td>±3%</td><td>20 mV</td></tr><tr><td>-12 V*</td><td>4.75 A</td><td>±3%</td><td>50 mV</td></tr></table>

# Cooling

■ Fans: 3 sets of 185.9 CFM fans
■ Per-slot cooling capacity: 25 W (verified by 55°C chamber test)

# Physical

■ Number of slots: 19
(1 system slot + 18 peripheral slots)
■ Dimensions: 444 mm (W) x 178 mm (H) x 455 mm (D) (17.3” x 6.9” x 17.7”)
■ Weight: 13.4 kg (29.5 lbs)

# Operating Environment

■ Ambient temperature: 0˚C to 55˚C (32˚F to 131˚F)
■ Relative humidity: 10% to 90%, non-condensing

# Storage Environment

■ Ambient temperature: -20˚C to 70˚C (-4˚F to 158˚F)
■ Relative humidity: 10% to 90%, non-condensing

# Shock and Vibration

■ Functional shock: 30 G, half-sine, 11 ms pulse duration
■ Random Vibration

• Operating: 5 to 500 Hz, 0.31 GRMS, 3 axes
• Non-operating: 5 to 500 Hz, 2.46 GRMS, 3 axes

# Emissions Compliance

■ EN 61326-1
■ FCC Class A

# CE Compliance

■ Safety: EN 61010-1
■ Immunity: EN 61326-1

Recommended System Controller

<table><tr><td></td><td>PXIS-2719A</td></tr><tr><td>PXI-3980/3950</td><td>√</td></tr></table>

![The image displays the word 'Google' in black text at the top left. Below the text is a large, light blue triangle pointing downwards. At the very bottom of the image, there is a thick black horizontal line.](.pxis-2719a-datasheet-en-1/d6cfcabb0cbbd39cf45a6a5bcb9acdcf077dba0b89c0ffc9983ab7a81a01f199.jpg)

# Ordering Information

■ PXIS-2719A

3U 19-Slot Smart PXI Chassis with 600 W AC Power Supply

■ PXIS-2719A Rack-mount Kit

Flexible Rack-mount Kit for PXIS-2719A
[🔗 Link to the original document](.pxis-2719a-datasheet-en-1/pxis-2719a-datasheet-en-1.pdf)