# AMC-7100

# AdvancedMC™ SAS Hard Drive Module

# User's Manual

![Close-up of a hard disk drive on a green circuit board (no visible text or symbols)](.amc-7100-50-1z004-1000-200/d77282e1e406abe38ef549c393a8deef249b5fb3446d1df5b9e91bacc687a8dc.jpg)

Manual Rev. 2.00

Revision Date: February 1, 2010

Part No: 50-1Z004-1000

![Circular black-and-white recycling symbol with three white arrows forming a triangle (no text or symbols)](.amc-7100-50-1z004-1000-200/aad937a2b98539ef2c8c9d77944dcfd7b4236d6f9b69f64a401ccb5a3d3598cd.jpg)

Recycled Paper

# Revision History

<table><tr><td>Revision</td><td>Release Date</td><td>Description of Change(s)</td></tr><tr><td>2.00</td><td>2010/02/01</td><td>Initial Release</td></tr></table>

# Preface

# Copyright 2010 ADLINK Technology Inc.

This document contains proprietary information protected by copyright. All rights are reserved. No part of this manual may be reproduced by any mechanical, electronic, or other means in any form without prior written permission of the manufacturer.

# Disclaimer

The information in this document is subject to change without prior notice in order to improve reliability, design, and function and does not represent a commitment on the part of the manufacturer.

In no event will the manufacturer be liable for direct, indirect, special, incidental, or consequential damages arising out of the use or inability to use the product or documentation, even if advised of the possibility of such damages.

# Environmental Responsibility

ADLINK is committed to fulfill its social responsibility to global environmental preservation through compliance with the European Union's Restriction of Hazardous Substances (RoHS) directive and Waste Electrical and Electronic Equipment (WEEE) directive. Environmental protection is a top priority for ADLINK. We have enforced measures to ensure that our products, manufacturing processes, components, and raw materials have as little impact on the environment as possible. When products are at their end of life, our customers are encouraged to dispose of them in accordance with the product disposal and/or recovery programs prescribed by their nation or company.

# Trademarks

Product names mentioned herein are used for identification purposes only and may be trademarks and/or registered trademarks of their respective companies.

# Using this Manual

# Audience and Scope

The AMC-7100 User's Manual is intended for hardware technicians and systems operators with knowledge of installing, configuring and operating industrial grade CompactPCI modules.

# Manual Organization

This manual is organized as follows:

Chapter 1, Overview: Introduces the AMC-7100, its features, and package contents.

Chapter 2, Installation: Provides detailed instructions for installing the AMC-7100.

Chapter 3, Functional Description: Describes the major functional features and capabilities of the AMC-7100

Chapter 4, Connector Pin Assignments: Describes the connector pin assignments of the AMC-7100.

Chapter 5, Specifications: Describes the environmental and mechanical specifications of the AMC-7100.

Chapter 6, Front Panel Indicators: Describes the the Front Panel LED indicators.

Chapter 7, IPMI Function List: Contains a listing of IPMI functions supported by the AMC-7100, including and Standard and OEM commands.

Important Safety Instructions: Presents safety instructions all users must follow for the proper setup, installation and usage of equipment and/or software.

Getting Service: Contact information for ADLINK's worldwide offices.

# Conventions

Take note of the following conventions used throughout this manual to make sure that users perform certain tasks and instructions properly.

![The image displays a white document icon with a folded top-left corner and horizontal grey lines suggesting text. A large, bold red checkmark is superimposed over the document, angling diagonally upwards from the bottom left to the top right.](.amc-7100-50-1z004-1000-200/86f2a585f006d7f015ad759967eefa4e353a5e7619856b0f0a8471ad22efc162.jpg)
NOTE:

Additional information, aids, and tips that help users perform tasks.

![The image displays a standard triangular warning sign. It features a bright yellow background enclosed by a thick black border. Centered within the triangle is a large black exclamation mark.](.amc-7100-50-1z004-1000-200/101c5616ea5a2396fb2665e6d96aac772ca4024b677271322ccca9cc8a9dbeec.jpg)
CAUTION:

Information to prevent minor physical injury, component damage, data loss, and/or program corruption when trying to complete a task.

![The image displays a red triangle with a white exclamation mark centered inside it, serving as a standard warning symbol.](.amc-7100-50-1z004-1000-200/1d3ccf4dac61c57ffd15af2fac03fb379f7a178a9e7684cbef0ad22467c36b34.jpg)
WARNING:

Information to prevent serious physical injury, component damage, data loss, and/or program corruption when trying to complete a specific task.

This page intentionally left blank.

# Table of Contents

# Revision History...... ii

# Preface...... iii

# Table of Contents...... vii

# List of Tables ix

# List of Figures ...... xi

# 1 Overview ...... 1

1.1 Introduction.... 1
1.2 Features.... 1
1.3 PICMG Standards Compliance.... 2
1.4 Package Contents 2

# 2 Installation 3

2.1 Important Information about Your Chassis 3
2.2 Before Installing or Removing the AMC.... 4
2.3 Verify Slot Usage 6
2.4 Module Hot Swap 6
2.5 Installing the AMC-7100 Module 8
2.6 Removing the AMC Module.... 9

# 3 Functional Description ...... 11

3.1 Overview.... 11
3.2 Serial Storage I/O Interfaces 12
3.3 Power Regulator 12
3.4 IPMI Subsystem.... 13

# 4 Connector Pin Assignments 15

4.1 AMC-7100 Port Assignments 15

# 5 Specifications.... 19

5.1 Hard Drive Operation and Storage Specifications .... 19
5.2 Power Requirements 20
5.3 EMC Compliance 21

# 6 Front Panel Indicators 23

# 7 IPMI Function List.... 25

7.1 Sensor Data Records.... 25
7.2 Supported IPMI Commands.... 28

# Important Safety Instructions.... 31

# Getting Service 33

# List of Tables

Table 3-1: I/O Ports Available on AMC Connector 12
Table 4-1: AMC-7100 AMC Port Assignments 15
Table 4-2: AMC Module Card-edge Interface Pin Assignment 16
Table 5-1: AMC-7100 Environmental Specifications, Hard Disk Drives 19
Table 5-2: AMC-7100 Power Requirements 20
Table 5-3: AMC-7100 EMC Emission Compliancy 21
Table 6-1: AMC-7100 LED Functions 23
Table 7-1: Sensor Data Records 25
Table 7-2: Standard FRU Data Records 26
Table 7-3: AMC-7100 E-Key Port Assignments 27
Table 7-4: Supported IPMI Commands 29

This page intentionally left blank.

# List of Figures

Figure 1-1: AMC-7100 Assembly Diagram ...... 1

Figure 2-1: AMC Module Handle 7

Figure 3-1: AMC-7100 Functional Blocks 11

Figure 6-1: AMC-7100 Front Panel Indicators 23

This page intentionally left blank.

# 1 Overview

# 1.1 Introduction

The AMC-7100 is an Advanced Mezzanine Card (AMC) module which provides embedded systems designers with an in-chassis storage solution that utilizes a SAS hard disk (HD). SAS technology generally boasts the greatest reliability and performance needed by mission critical enterprise applications. The Module is as single-width AMC with mid-size panel and hard drive in 2.5" small form factor, to provide the greatest spindle density for your ATCA or MicroTCA application. The AMC-7100 also includes a modular management controller (MMC).

![Disk Drive](.amc-7100-50-1z004-1000-200/f11872dae225d9762a504d6adcd166547d4755224e287c5470e8db8e7f2717c9.jpg)

Figure 1-1: AMC-7100 Assembly Diagram

# 1.2 Features

The AMC-7100 is a single-width mid-size AMC Module with the following features:

▶ Accommodates a single 2.5" SAS 146GB hard drive
▶ Supports both Port 2 and Port 3 via switch setting or IPMI control
▶ Drive over-current protection
▶ General Advanced Mezzanine Card Features
▶ Ejector switches for hot swap
▶ One blue hot swap LED

▶ OOS (Out-of-Service) LED
▶ Bi-color LED for Port 2/3 designation, and activity

Refer to Chapter 5: Specifications for additional details regarding environmental, mechanical, power specifications, as well as reliability and compliance statements.

# 1.3 PICMG Standards Compliance

The AMC-7100 is fully compliant with the following PCI Industrial Computer Manufacturers Group (PICMG) specifications:

▶ PICMG AMC.0 R2.0
▶ PICMG AMC.3 R1.0 storage signaling option

# 1.4 Package Contents

The AMC-7100 is packaged with the following components. If any of the items on the contents list are missing or damaged, retain the shipping carton and packing material and contact the dealer for inspection. Please obtain authorization before returning any product to ADLINK.

▶ AMC-7100 AdvancedMC™ SAS 146GB Hard Drive Module
▶ User's manual

![The image shows a yellow triangular warning sign with a black border containing a large black exclamation point. Below the triangle, the text 'CAUTION:' is written in black capital letters.](.amc-7100-50-1z004-1000-200/29a9f6c5eed185f35352e9c0694f25eed215f31c30ef31b573e7f0feaa8fedba.jpg)

This product must be protected from static discharge and physical shock. Never remove any of the components except at a static-free workstation. Use the anti-static bag shipped with the product when putting the board on a surface. Wear an anti-static wrist strap properly grounded on one of the system's ESD ground jacks when installing or servicing system components.

# 2 Installation

This chapter contains the procedures for installing and removing the AMC-7100 AMC module.

The AMC-7100 Module can be installed into an ATCA AdvancedMC carrier board or MicroTCA chassis with slots designed to accept AMC.3 installations. The module slot height must properly match the panel height fitted to the AMC.

# 2.1 Important Information about Your Chassis

The AMC-7100 is designed to PICMG specifications and is a general-purpose Advanced Mezzanine Card. Before using this board, review the specifications of the chassis and backplane that will house the module to determine the presence of, and any limitations of, chassis, IPMI bus, and user defined pin outs. For example, some chassis backplanes route certain I/O pins to internal resources such as alarm cards and drive resources. The AMC-7100 is intended for an Advanced TCA AMC carrier card or MicroTCA chassis/backplanes/slots that are AMC.3 compliant. It is your responsibility to verify this system compatibility. Failure to do so could result in improper operation or equipment damage.

# UL-Listed Accessory – For Use Statement

The AMC-7100 is a UL-Listed “accessory” and CUL-Listed “accessory” for use with UL-Listed AdvancedTCA and MicroTCA products that have a user’s guide detailing user installation of AMC module accessories.

# Maximum Module Current Requirements

Be sure to validate the host chassis, and the intended AMC slot is cable of meeting the AMC modules with maximum current requirements.

AMC-7100 Max. Current Draw: 1.41 A

# 2.2 Before Installing or Removing the AMC

Boards may be damaged if improperly installed or handled. Please read and follow the guidelines in this section to protect your equipment.

# ESD Precautions

ADLINK strongly recommends that you use an antistatic wrist strap and a conductive foam pad when installing or upgrading a system. Electronic components, such as disk drives, computer boards, and memory modules, can be extremely sensitive to electrostatic discharge (ESD). After removing the component from its protective wrapper or from the system, place the component flat on a grounded, static-free surface (and, in the case of a board, component side up). Do not slide the component over any surface.

If an ESD station is not available, you can avoid damage resulting from ESD by wearing an antistatic wrist strap (available at electronics stores) that is attached to an active electrical ground. Note that a system chassis may not be grounded if it is unplugged.

# Bent Pins or Other Damage

Bent pins or loose components can cause damage to the board, the backplane, or other system components. Carefully inspect your board and the backplane for both pin and component integrity before installation. Our suppliers take significant steps to ensure there are no bent pins on the backplane or connector damage to the boards prior to leaving our factory. Bent pins caused by improper installation or by boards with damaged connectors could void the warranty for the backplane or boards.

If a system contains one or more crushed pins, power off the system and contact your local sales representative to schedule delivery of a replacement chassis assembly.

# Caution Areas

![The image features a yellow triangular warning sign with a black border and a black exclamation mark in the center. Below the triangle, the word 'CAUTION:' is displayed in black capital letters.](.amc-7100-50-1z004-1000-200/d9e979b03d334ccd4c1b39f32d132cdd28dabbfbfd970f0cf8654ee871bd7efa.jpg)

When first installing boards in an empty chassis or onto a carrier board, we recommend that you start at the left of the card cage and work to the right.

When inserting or removing a board in a slot adjacent to other boards, use extra caution to avoid damage to the pins and components located on the primary or secondary sides of the boards.

# Preserving EMI Compliance

To preserve compliance with applicable standards and regulations for electromagnetic interference (EMI), during operation all front and rear openings on the chassis or board faceplates must be filled with an appropriate card or covered with a filler panel. If the EMI barrier is open, devices may cause or be susceptible to excessive interference.

# Understanding Hot Swap

Your AMC-7100 is electrically designed for hot swap within a fully powered chassis. To facilitate hot swap, there is a blue LED on the front faceplate. This LED is under software control.

If your system is using software that provides full hot swap capabilities, the software will illuminate the blue hot swap LED on the AMC faceplate when software has stopped and it is safe to remove the AMC module.

If your system does not have hot-swap aware software running, behavior of the blue LED is indeterminate. In this case, you may need to manually shut down applications or operating systems running on the board prior to board removal, even if the blue LED is lit.

Powering down or removing a board before the operating system or other software running on the board has been properly shut down may cause corruption of data or file systems.

# 2.3 Verify Slot Usage

![The image shows a standard warning sign featuring a yellow triangle with a black border containing a black exclamation point in the center. Below the triangle, the word 'CAUTION:' is printed in black capital letters on a white background.](.amc-7100-50-1z004-1000-200/7b4a93bcc369d4063f803f68635d8c16ab7aebe55aca44f815257dcee11bc0a3.jpg)

Prevent possible damage to module components by verifying the proper slot usage for your configuration. In most cases, electronic keying (E-keying) will prevent powering on of a board installed in an incompatible slot. However, as an extra precaution, you should be familiar with the slot purpose.

# 2.4 Module Hot Swap

This section describes a recommended procedure for installing a board module in a chassis. The AMC-7100 module has a latching mechanism. The Latch Mechanism includes the module handle with an integrated multi-position shaft and micro-switch (see figure below).

The module handle is held in place by the faceplate, while the micro-switch is mounted on the module printed circuit board. The module handle is used to activate the micro-switch, which allows for Hot Swap switch as well as for extracting the module out of the connector and the AMC bay.

There are 3 positions of the Module Handle:

1. Pushed all the way in (IN) - When IN the module sends a signal to the Shelf Manager that the module is not in the Hot Swap state and the Shelf Manager will communicate with the MMC. This is the position that the Module Handle should be in during normal operation.
2. Half Way (HW) - When the Module Handle is in the HW position, the Hot Swap switch is open and the MMC will send a Hot Swap event to the Shelf manager.
3. Out (OUT) - When the Module Handle is in the OUT position the latching mechanism is released and the module can be extracted.

The use of the Module Handle is used in conjunction with the Blue LED. Please refer to the text below for more detailed instructions on insertion and extraction.

![3D mechanical assembly diagram showing a component with a blue base and green handle, no visible text or symbols](.amc-7100-50-1z004-1000-200/8ba40fec0953ae9a76edb55c6d272b5157b8d03ad7c7da076318ec5613a9a554.jpg)

Figure 2-1: AMC Module Handle

# 2.5 Installing the AMC-7100 Module

This section describes a recommended procedure for installing a board module in a chassis.

Before you install your module, please read all cautions, warnings, and instructions presented in this section.

![The image displays a safety warning sign. It features a yellow equilateral triangle with a black border containing a large black exclamation point in the center. Directly below the triangle is a white rectangular field with the text 'CAUTION:' printed in black capital letters.](.amc-7100-50-1z004-1000-200/36a6b639f07766c2671698d53861a11f18afb3683eca69fedfad306646a5ec58.jpg)

Handling modules and peripherals can result in static damage. Use a grounded wrist strap, static-dissipating work surface, and antistatic containers when handling and storing components.

Insert the board by holding the Module Handle—do not exert unnecessary pressure on the faceplate.

![The image displays a standard safety warning sign. It features a yellow triangle with a thick black border. Inside the triangle is a large black exclamation point, accompanied by a small black dot directly beneath it. Below the triangle, the word 'CAUTION' is printed in black capital letters.](.amc-7100-50-1z004-1000-200/40cff9ffecb6479f734001e0ebb8497df6d6749f25f4fa734a3329c236fd3163.jpg)

Hot swap compliant modules may be installed while the system is powered on. If a module is not hot swap compliant (or the system does not support hot swap), you should remove power to the slot or system before installing the module.

1. Verify that you have taken the necessary antistatic precautions.
2. Inspect the ATCA carrier board or MicroTCA chassis, and locate the desired AMC slot.
3. Remove the slot filler panel from the selected AMC slot, if necessary.
4. Carefully align the edges of the module with the rail guides in the appropriate slot or carrier card.
5. Taking care to keep the module aligned in the guides, apply equal and steady pressure and slide the module in until the fingers of the module snap into the internal AMC connector.
6. DO NOT FORCE THE BOARD INTO THE SLOT.
7. Push the Module Handle to the IN position.
8. Power on the system, if necessary. Refer to your system manual for instructions on correctly powering on the system. Once power is applied to the chassis, the internal MMC controller runs a self-test that runs for approximately 10 seconds. Upon a successful power up self-test, the blue hot swap LED will blink and then turn off, indicating that the module has been placed in operation.

# 2.6 Removing the AMC Module

The AMC-7100 is hot-swappable and can be removed from the chassis without powering down the associated host carrier or chassis. This section describes the recommended procedure for removing an AMC module.

![A yellow triangular warning sign with a black border featuring a central black exclamation point, with the text 'CAUTION:' in bold black capital letters below it.](.amc-7100-50-1z004-1000-200/4790daf6595da45df8f67618efbaee0862ff3d678c196b9e3d989c35beae11d8.jpg)

Before you remove your module, please read all cautions, warnings, and instructions presented in this section. Hot swap compliant modules may be removed while the system is powered on. If the chassis is not hot swap compliant, you should remove power to the slot or system before removing the module.

To remove the AMC module, follow these steps:

1. Begin to remove your module by pulling the Module Handle to the half way (HW) position. Do not remove the module

2. Powering down or removing a board before the operating system or other software running on the board has been properly shut down may cause corruption of data or file systems.

3. If your module is hot swap compliant and you are running fully functional hot swap-aware software, unlatching this ejector lever will start the shutdown process on the board. The software will slowly blink the blue hot swap LED indicating the module is in the process of being de-activated.

4. Once the module has been de-activated, the Blue LED will solidly illuminate. Once this is done you can extract the module by pulling on the module handle.

5. WARNING: Some AMC-7100 models may display this symbol to indicate the possible presence of a hot surface or component reaching up to 85C. To

![The image displays a black-outlined triangle containing a symbol consisting of three vertical wavy lines rising above a horizontal line.](.amc-7100-50-1z004-1000-200/e597346d97bcf2aec19a5fdd09569c747f36ef25ef3758772dbd24611788d370.jpg)

reduce the risk of injury from a hot component when servicing, allow the surface to cool before touching.

6. If your board or system is not running hot swap-aware software, the blue LED may illuminate without regard to software processes still running on the board. Be sure to manually shut down applications or operating systems running on the board prior to board removal.

7. Carefully pull the module from the chassis. If the card slot is to remain empty, install a filler panel in the slot.

# 3 Functional Description

This chapter provides a functional description of the major components and devices on the AMC-7100.

# 3.1 Overview

The AMC-7100 contains three major functional blocks. These are:

1. The Serial Storage interface
2. The Power Regulator, and
3. The IPMI subsystem (Module Management Controller - MMC)

The following block diagram illustrates the major components and switch locations on the AMC-7100.

![The image displays a vertical block diagram containing several components enclosed within a large lime-green rectangular boundary. The components, from top to bottom, are:\n\n1.  An orange rectangle labeled **'AMC FINGERS'**.\n2.  A light blue rectangle labeled **'Power Regulator'**.\n3.  A large central light blue rectangle labeled **'SAS HDD'**.\n4.  A small dark grey rectangle labeled **'HDD CONNECTOR'**.\n5.  A small light blue rectangle in the bottom right corner labeled **'MMC'**.\n6.  Two small orange squares in the bottom left area.\n\nThere are two external labels with specific connections:\n*   The text **'Port Select Switch'** has an arrow pointing to the second (right-hand) small orange square.\n*   The text **'Hot Swap Switch'** is centered below the two small orange squares.](.amc-7100-50-1z004-1000-200/49a6debd23b7b4a6daa100363891839eb3d915a0dd5310cf0c7a954ca3da7aed.jpg)

Figure 3-1: AMC-7100 Functional Blocks

# 3.2 Serial Storage I/O Interfaces

The AMC-7100 AMC modules plug into ATCA carrier boards which support AMC.3 storage signaling.

<table><tr><td>AMC I/O</td><td>Description</td></tr><tr><td>Port 2</td><td>3Gb SAS, Receive and transmit pairs</td></tr><tr><td>Port 3</td><td>3Gb SAS, Receive and transmit pairs</td></tr><tr><td>MMC Device</td><td>Serial IPMI management bus</td></tr></table>

Table 3-1: I/O Ports Available on AMC Connector

# AMC Serial Storage Port Assignments

The AMC-7100 supports SAS DUAL PORT hard disk. Port 2 is always the SAS primary port and Port 3 is always the SAS secondary port.

# Serial Storage Port Selection via IPMI

The MMC firmware allows the selection of an alternate port by use of the “Set AMC Port State” command to first disable the enabled port, followed by a “Set AMC Port State” command to enable the alternate port.

If the MMC firmware receives a "Set AMC Port State" to enable the other port while the current port is already enabled, the command will respond with 0xD5, Cannot Execute Command completion code.

In order for the MMC to change ports, the Port Select Switch (SW1/POS1) setting must be in the OFF position (see Figure 3-1: AMC-7100 Functional Blocks on Page 11).

# 3.3 Power Regulator

The Power Regulator is the part of the module that generates the required power from the payload power (+12V) that is delivered to the module through the AMC connector. This power is current limited by the onboard regulator.

# 3.4 IPMI Subsystem

The IPMI subsystem provides management control for the board. It is based on an Atmel microcontroller (Module Management Controller - MMC). Its function is to monitor module functions such as power, temperature, and hot swap requests via the ejector handle and report these to the base controller in the enclosure. It also stores information about the module including serial number and E-Keying.

This page intentionally left blank.

# 4 Connector Pin Assignments

This chapter provides connector pin assignments for AMC-7100. This module is AMC.3 compliant and uses Ports 2 and 3 as defined in the AMC.3 specification.

# 4.1 AMC-7100 Port Assignments

Below are the specific ports that are used by the AMC-7100. All other pins match the AMC.0 specification.

<table><tr><td>Port</td><td>Signal</td></tr><tr><td>2</td><td>AMC.3 Serial Storage Port 2</td></tr><tr><td>3</td><td>AMC.3 Serial Storage Port 3</td></tr></table>

Table 4-1: AMC-7100 AMC Port Assignments

# AMC-7100 Card-edge Interface Pin Assignments

The AMC-7100 includes an AMC connector which conforms to the single slot B+ extended connector, with 170 signal contacts. The pin assignments are as follows.

<table><tr><td>Pin#</td><td>Signal</td><td>Pin#</td><td>Signal</td></tr><tr><td>1</td><td>GND</td><td>86</td><td>GND</td></tr><tr><td>2</td><td>12V</td><td>87</td><td>No Connect</td></tr><tr><td>3</td><td>&#x27;PRSNT1_L&#x27;</td><td>88</td><td>No Connect</td></tr><tr><td>4</td><td>&#x27;AMC_VCC3&#x27;</td><td>89</td><td>GND</td></tr><tr><td>5</td><td>GA0</td><td>90</td><td>No Connect</td></tr><tr><td>6</td><td>No Connect</td><td>91</td><td>No Connect</td></tr><tr><td>7</td><td>GND</td><td>92</td><td>GND</td></tr><tr><td>8</td><td>No Connect</td><td>93</td><td>No Connect</td></tr><tr><td>9</td><td>12V</td><td>94</td><td>No Connect</td></tr><tr><td>10</td><td>GND</td><td>95</td><td>GND</td></tr><tr><td>11</td><td>No Connect</td><td>96</td><td>No Connect</td></tr><tr><td>12</td><td>No Connect</td><td>97</td><td>No Connect</td></tr><tr><td>13</td><td>GND</td><td>98</td><td>GND</td></tr><tr><td>14</td><td>No Connect</td><td>99</td><td>No Connect</td></tr><tr><td>15</td><td>No Connect</td><td>100</td><td>No Connect</td></tr><tr><td>16</td><td>GND</td><td>101</td><td>GND</td></tr><tr><td>17</td><td>GA1</td><td>102</td><td>No Connect</td></tr><tr><td>18</td><td>12V</td><td>103</td><td>No Connect</td></tr><tr><td>19</td><td>GND</td><td>104</td><td>GND</td></tr><tr><td>20</td><td>No Connect</td><td>105</td><td>No Connect</td></tr><tr><td>21</td><td>No Connect</td><td>106</td><td>No Connect</td></tr><tr><td>22</td><td>GND</td><td>107</td><td>GND</td></tr><tr><td>23</td><td>No Connect</td><td>108</td><td>No Connect</td></tr><tr><td>24</td><td>No Connect</td><td>109</td><td>No Connect</td></tr><tr><td>25</td><td>GND</td><td>110</td><td>GND</td></tr><tr><td>26</td><td>GA2</td><td>111</td><td>No Connect</td></tr><tr><td>27</td><td>12V</td><td>112</td><td>No Connect</td></tr><tr><td>28</td><td>GND</td><td>113</td><td>GND</td></tr><tr><td>29</td><td>&#x27;TX_SATA_2+&#x27;</td><td>114</td><td>No Connect</td></tr><tr><td>30</td><td>&#x27;TX_SATA_2-&#x27;</td><td>115</td><td>No Connect</td></tr></table>

Table 4-2: AMC Module Card-edge Interface Pin Assignment

<table><tr><td>Pin#</td><td>Signal</td><td>Pin#</td><td>Signal</td></tr><tr><td>31</td><td>GND</td><td>116</td><td>GND</td></tr><tr><td>32</td><td>&#x27;RX_SATA_2+&#x27;</td><td>117</td><td>No Connect</td></tr><tr><td>33</td><td>&#x27;RX_SATA_2-&#x27;</td><td>118</td><td>No Connect</td></tr><tr><td>34</td><td>GND</td><td>119</td><td>GND</td></tr><tr><td>35</td><td>&#x27;TX_SATA_3+&#x27;</td><td>120</td><td>No Connect</td></tr><tr><td>36</td><td>&#x27;TX_SATA_3-&#x27;</td><td>121</td><td>No Connect</td></tr><tr><td>37</td><td>GND</td><td>122</td><td>GND</td></tr><tr><td>38</td><td>&#x27;RX_SATA_3+&#x27;</td><td>123</td><td>No Connect</td></tr><tr><td>39</td><td>&#x27;RX_SATA_3-&#x27;</td><td>124</td><td>No Connect</td></tr><tr><td>40</td><td>GND</td><td>125</td><td>GND</td></tr><tr><td>41</td><td>&#x27;AMC_ENABLE_L&#x27;</td><td>126</td><td>No Connect</td></tr><tr><td>42</td><td>12V</td><td>127</td><td>No Connect</td></tr><tr><td>43</td><td>GND</td><td>128</td><td>GND</td></tr><tr><td>44</td><td>No Connect</td><td>129</td><td>No Connect</td></tr><tr><td>45</td><td>No Connect</td><td>130</td><td>No Connect</td></tr><tr><td>46</td><td>GND</td><td>131</td><td>GND</td></tr><tr><td>47</td><td>No Connect</td><td>132</td><td>No Connect</td></tr><tr><td>48</td><td>No Connect</td><td>133</td><td>No Connect</td></tr><tr><td>49</td><td>GND</td><td>134</td><td>GND</td></tr><tr><td>50</td><td>No Connect</td><td>135</td><td>No Connect</td></tr><tr><td>51</td><td>No Connect</td><td>136</td><td>No Connect</td></tr><tr><td>52</td><td>GND</td><td>137</td><td>GND</td></tr><tr><td>53</td><td>No Connect</td><td>138</td><td>No Connect</td></tr><tr><td>54</td><td>No Connect</td><td>139</td><td>No Connect</td></tr><tr><td>55</td><td>GND</td><td>140</td><td>GND</td></tr><tr><td>56</td><td>&#x27;IPMI_SCL_L&#x27;</td><td>141</td><td>No Connect</td></tr><tr><td>57</td><td>12V</td><td>142</td><td>No Connect</td></tr><tr><td>58</td><td>GND</td><td>143</td><td>GND</td></tr><tr><td>59</td><td>No Connect</td><td>144</td><td>No Connect</td></tr><tr><td>60</td><td>No Connect</td><td>145</td><td>No Connect</td></tr></table>

Table 4-7: AMC Module Card-edge Interface Pin Assignment (cont'd)

<table><tr><td>Pin#</td><td>Signal</td><td>Pin#</td><td>Signal</td></tr><tr><td>61</td><td>GND</td><td>146</td><td>GND</td></tr><tr><td>62</td><td>No Connect</td><td>147</td><td>No Connect</td></tr><tr><td>63</td><td>No Connect</td><td>148</td><td>No Connect</td></tr><tr><td>64</td><td>GND</td><td>149</td><td>GND</td></tr><tr><td>65</td><td>No Connect</td><td>150</td><td>No Connect</td></tr><tr><td>66</td><td>No Connect</td><td>151</td><td>No Connect</td></tr><tr><td>67</td><td>GND</td><td>152</td><td>GND</td></tr><tr><td>68</td><td>No Connect</td><td>153</td><td>No Connect</td></tr><tr><td>69</td><td>No Connect</td><td>154</td><td>No Connect</td></tr><tr><td>70</td><td>GND</td><td>155</td><td>GND</td></tr><tr><td>71</td><td>&#x27;IPMI_SDA_L&#x27;</td><td>156</td><td>No Connect</td></tr><tr><td>72</td><td>12V</td><td>157</td><td>No Connect</td></tr><tr><td>73</td><td>GND</td><td>158</td><td>GND</td></tr><tr><td>74</td><td>No Connect</td><td>159</td><td>JTAG- TCK</td></tr><tr><td>75</td><td>No Connect</td><td>160</td><td>JTAG- TDI</td></tr><tr><td>76</td><td>GND</td><td>161</td><td>GND</td></tr><tr><td>77</td><td>No Connect</td><td>162</td><td>JTAG - TMS</td></tr><tr><td>78</td><td>No Connect</td><td>163</td><td>JTAG- TDO</td></tr><tr><td>79</td><td>GND</td><td>164</td><td>GND</td></tr><tr><td>80</td><td>No Connect</td><td>165</td><td>No Connect</td></tr><tr><td>81</td><td>No Connect</td><td>166</td><td>No Connect</td></tr><tr><td>82</td><td>GND</td><td>167</td><td>No Connect</td></tr><tr><td>83</td><td>&#x27;PRSNT0_L&#x27;</td><td>168</td><td>No Connect</td></tr><tr><td>84</td><td>12V</td><td>169</td><td>No Connect</td></tr><tr><td>85</td><td>GND</td><td>170</td><td>GND</td></tr></table>

Table 4-7: AMC Module Card-edge Interface Pin Assignment (cont'd)

# 5 Specifications

This chapter contains the environmental and mechanical specifications for the AMC-7100. The environmental specifications relate to and vary with the Hard Drive that the AMC-7100 is configured with.

5.1 Hard Drive Operation and Storage Specifications

<table><tr><td colspan="2">Specification</td><td>Enterprise SAS</td></tr><tr><td rowspan="4">Temperature</td><td>Operating (ambient)</td><td>5°C to 55°C</td></tr><tr><td>Disk enclosure surface</td><td>5°C to 60°C (operating)</td></tr><tr><td>Non-operating</td><td>-40°C to 70°C</td></tr><tr><td>Gradient</td><td>3°C/min – (20°C/hour)</td></tr><tr><td rowspan="3">Relative humidity</td><td>Operating</td><td>5% to 95%</td></tr><tr><td>Non-operating</td><td>5% to 95%</td></tr><tr><td>Maximum wet bulb</td><td>29°C (operating)</td></tr><tr><td rowspan="2">Vibration</td><td>Operating</td><td>1G (20 to 300Hz)</td></tr><tr><td>Non-operating</td><td>5G (20 to 300Hz)</td></tr><tr><td rowspan="2">Shock</td><td>Operating</td><td>100 G / 1ms duration</td></tr><tr><td>Non-operating</td><td>400 G / 1ms duration</td></tr><tr><td rowspan="2">Altitude</td><td>Operating</td><td>-1,000 to +10,000 feet</td></tr><tr><td>Non-operating</td><td>-1,000 to +40,000 feet</td></tr><tr><td rowspan="5">Performance</td><td>RPM</td><td>10,000</td></tr><tr><td>Seek time Avg</td><td>Read/write 4.5 ms (typical)</td></tr><tr><td>Seek time Max</td><td>Read/write 9.0ms (typical)</td></tr><tr><td>Interface</td><td>SAS 3.0Gb</td></tr><tr><td>MTBF</td><td>280,000H</td></tr></table>

Table 5-1: AMC-7100 Environmental Specifications, Hard Disk Drives

# 5.2 Power Requirements

The AMC-7100 shall consume no more than the following from the system supplies under normal operating conditions

<table><tr><td>Power Source</td><td>Current</td></tr><tr><td>Management Power (MP)</td><td>100 mA</td></tr><tr><td>+12V (spin up &lt; 8secs)</td><td>1.41 A (17 W)</td></tr><tr><td>+12V normal operating</td><td>0.65 A (7.8 W)</td></tr><tr><td>+12V (idle)</td><td>0.51 A (6.12 W)</td></tr><tr><td>Off State</td><td>less than 0.4 W</td></tr></table>

Table 5-2: AMC-7100 Power Requirements

# 5.3 EMC Compliance

This product was tested in an EMC-compliant chassis and meets the requirements for EN55022 Class A equipment. Compliance was achieved under the following conditions:

▶ Conductive chassis rails connected to earth ground, providing the path for connecting shields to earth ground
▶ Front panel screws properly tightened

For minimum RF emissions, it is essential that the conditions above be implemented. Failure to do so could compromise the EMC compliance of the equipment containing the module.

<table><tr><td>Standard</td><td>Description</td></tr><tr><td>US: FCC 47 CFR Part 15 Class A</td><td>Yes, Class A emissions requirements (USA)</td></tr><tr><td>Canada: ICES 003 Class A</td><td>Yes Class A Digital Apparatus emissions (Canada)</td></tr><tr><td>Japan: VCCI Class A</td><td>Yes Class A ITE emissions requirements (Japan)</td></tr><tr><td>Europe Commercial: EN 55022:1994 Class A</td><td>Yes, Class A ITE emissions requirements (EU)</td></tr><tr><td>Europe Commercial: EN 55024:1998 Class A</td><td>Immunity for ITE equipment</td></tr><tr><td>Europe Commercial: EN 61000-4-2,3,5,6,8,11: 2001</td><td>EMC Electrostatic discharge immunity</td></tr><tr><td>Europe Commercial: EN 61000-4-4: 2000 (Limits for harmonic current emissions)</td><td>Yes</td></tr><tr><td>Europe Commercial: EN 61000-3-2,3</td><td>Yes, Limits for harmonic current emissions</td></tr><tr><td>Europe Telecom Carrier: EN 300-386 v1.3.3 April 2005</td><td>Requirements for Telecom Network Equipment – Non-Telco Centers</td></tr><tr><td>Europe CE Mark</td><td>Yes</td></tr><tr><td>Australia: AS/NZS 3548 C-Tick</td><td>Yes, Class A ITE emissions requirements (Australia)</td></tr></table>

Table 5-3: AMC-7100 EMC Emission Compliance

This page intentionally left blank.

# 6 Front Panel Indicators

The faceplate of the AMC-7100 module has 3 LED indicators. The figure and table below describe their functions.

![ACT\nOOS\nHS\nS\nS](.amc-7100-50-1z004-1000-200/0909496e744fb5aaf18247eed402917f6933341f461f9824a02b04f34ae59879.jpg)

Figure 6-1: AMC-7100 Front Panel Indicators

<table><tr><td>Indicator</td><td>Color</td><td>State</td><td>Function</td></tr><tr><td rowspan="4">Hot Swap (HS)</td><td rowspan="4">Blue</td><td>On</td><td>Management power available to the module and the module can safely be extracted</td></tr><tr><td>Off</td><td>The module is operational and is unsafe for extraction</td></tr><tr><td>Long Blink</td><td>Delay before module is activated</td></tr><tr><td>Short Blink</td><td>Delay before module is deactivated</td></tr><tr><td rowspan="2">Fault or “Out of Service” (OOS)</td><td rowspan="2">Red</td><td>On</td><td>Module Fault set by Shelf Manager or 12V payload power not detected</td></tr><tr><td>Off</td><td>No module fault; 12V payload power is being supplied to board</td></tr><tr><td rowspan="2">Module Active (ACT) and “in service”</td><td rowspan="2">Green</td><td>On</td><td>12V payload power is being supplied to board</td></tr><tr><td>Off</td><td>12V payload power is not detected</td></tr></table>

Table 6-1: AMC-7100 LED Functions

This page intentionally left blank.

# 7 IPMI Function List

The AMC-7100 module employs a Module Management Controller (MMC) as specified in the AMC.0 R2.0 specification. The MMC provides an Intelligent Platform Management Interface (IPMI) which will communicate with the AdvancedTCA and $\mu$ TCA shelf managers. This MMC controls and monitors the following:

▶ Hot Swap communication with the shelf manager
▶ Inlet air temperature
▶ Voltage monitoring
Electronic Keying as described in the AMC.0 specification
▶ FRU information
- Drives LED indicators for Hot Swap. OOS (out of service), and Port selection

# 7.1 Sensor Data Records

The MMC monitors the status of the module and provides this data so it can be read by the shelf manager. Below are the Sensor Data Records (SDRs) that the AMC-7100 module creates.

<table><tr><td>Signal Type</td><td>Item Monitored</td></tr><tr><td>Event</td><td>Hot Swap Switch</td></tr><tr><td>Threshold</td><td>+1.2V Payload Power</td></tr><tr><td>Threshold</td><td>+3.3V Payload Power</td></tr><tr><td>Threshold</td><td>+12V Payload Power</td></tr><tr><td>Threshold</td><td>Inlet Air Temperature</td></tr><tr><td>Threshold</td><td>Exit Air Temperature over HDD</td></tr></table>

Table 7-1: Sensor Data Records

The AMC-7100 includes the standard FRU data records per the IPMI Platform Management FRU Information Storage Definition, Board Info Area. The AMC-7100 includes additional FRU records as defined in the PICMG 2.9 specification.

<table><tr><td colspan="2">Board Info</td></tr><tr><td>Manufacturer</td><td>ADLINK Technology, Inc.</td></tr><tr><td>Product Name</td><td>AMC-7100/146G</td></tr><tr><td>Part Number</td><td>AMC-7100/146G</td></tr><tr><td>Serial Number</td><td>048LYMMSSSS (Note 1)</td></tr><tr><td colspan="2">Product Info</td></tr><tr><td>Manufacturer</td><td>ADLINK Technology, Inc.</td></tr><tr><td>Product Name</td><td>AMC-7100/146G</td></tr><tr><td>Part/Model Number</td><td>AMC-7100/146G</td></tr><tr><td>Product Version</td><td>##</td></tr><tr><td>Serial Number</td><td>048LYMMSSSS (Note 1)</td></tr></table>

Table 7-2: Standard FRU Data Records

Note 1: Serial Number format: 048LYMMSSSS

L = location of manufacture, YMM = year and month of manufacture, SSSS = quantity sequence (resets monthly)

$$
\begin{array}{l} 0 4 8 = \text { part   code   (denotes   AMC - 7100) } \\ L = \text { location   of   manufacture } \\ Y = \text { year   (hex: } 4 = 2 0 0 4 A = 2 0 1 0) \\ M M = m o n t h \\ \text { SSSS } = \text { sequence   number(0 - 9999) } \\ \end{array}
$$

# AMC Port Assignments

The AMC-7100 connects up to two ports on the AMC connector. These are defined by the AMC.3 specification for serial storage. The link type and link type extension are defined in the table below.

<table><tr><td>Port #</td><td>Port Name</td><td>Link type</td><td>AMC port map region</td></tr><tr><td>0</td><td>unused</td><td></td><td></td></tr><tr><td>1</td><td>unused</td><td></td><td></td></tr><tr><td>2</td><td>Channel 0</td><td>Link type 7 = AMC.3 Storage, Link type extension = 2 (SAS/SATA) AMC Asymmetric Match = 00b (SAS)</td><td>Common Options</td></tr><tr><td>3</td><td>Channel 1</td><td>Link type 7 = AMC.3 Storage, Link type extension = 2 (SAS/SATA) AMC Asymmetric Match = 00b (SAS)</td><td>Common Options</td></tr><tr><td>4-20</td><td>unused</td><td></td><td></td></tr></table>

Table 7-3: AMC-7100 E-Key Port Assignments

# 7.2 Supported IPMI Commands

The MMC communicates with the carrier controller through the local IPMB-L bus of the carrier and responds to all mandatory commands for AMC Module Management Controllers (as defined in the AMC Specification), as well as some optional ones.

<table><tr><td>Command</td><td>IPMI/PICMG/AMC Spec</td><td>NetFn</td><td>CMD</td><td>MMC Req</td></tr><tr><td colspan="5">IPM Device “Global” Commands</td></tr><tr><td>Get Device ID</td><td>17.1</td><td>App</td><td>01h</td><td>Mandatory</td></tr><tr><td>Broadcast “Get Device ID”</td><td>17.9</td><td>App</td><td>01h</td><td>Mandatory</td></tr><tr><td colspan="5">Messaging Commands</td></tr><tr><td>Send Message</td><td>18.7</td><td>App</td><td>34h</td><td>Optional</td></tr><tr><td colspan="5">Event Commands</td></tr><tr><td>Platform Event</td><td>23.3</td><td>S/E</td><td>02h</td><td>Mandatory</td></tr><tr><td colspan="5">Sensor Device Commands</td></tr><tr><td>Get Device SDR Info</td><td>29.2</td><td>S/E</td><td>20h</td><td>Mandatory</td></tr><tr><td>Get Device SDR</td><td>29.3</td><td>S/E</td><td>21h</td><td>Mandatory</td></tr><tr><td>Reserve Device SDR Repository</td><td>29.4</td><td>S/E</td><td>22h</td><td>Mandatory</td></tr><tr><td>Get Sensor Reading Factors</td><td>29.5</td><td>S/E</td><td>23h</td><td>Optional</td></tr><tr><td>Set Sensor Hysteresis</td><td>29.6</td><td>S/E</td><td>24h</td><td>Optional</td></tr><tr><td>Get Sensor Hysteresis</td><td>29.7</td><td>S/E</td><td>25h</td><td>Optional</td></tr><tr><td>Set Sensor Threshold</td><td>29.8</td><td>S/E</td><td>26h</td><td>Optional</td></tr><tr><td>Get Sensor Threshold</td><td>29.9</td><td>S/E</td><td>27h</td><td>Optional</td></tr><tr><td>Set Sensor Event Enable</td><td>29.10</td><td>S/E</td><td>28h</td><td>Optional</td></tr><tr><td>Get Sensor Event Enable</td><td>29.11</td><td>S/E</td><td>29h</td><td>Optional</td></tr><tr><td>Rearm Sensor Events</td><td>29.12</td><td>S/E</td><td>2Ah</td><td>Optional</td></tr><tr><td>Get Sensor Event Status</td><td>29.13</td><td>S/E</td><td>2Bh</td><td>Optional</td></tr><tr><td>Get Sensor Reading</td><td>29.14</td><td>S/E</td><td>2Dh</td><td>Mandatory</td></tr><tr><td colspan="5">FRU Device Commands</td></tr><tr><td>Get FRU Inventory Area Info</td><td>28.1</td><td>Storage</td><td>10h</td><td>Mandatory</td></tr><tr><td>Read FRU Data</td><td>28.2</td><td>Storage</td><td>11h</td><td>Mandatory</td></tr><tr><td>Write FRU Data</td><td>28.3</td><td>Storage</td><td>12h</td><td>Mandatory</td></tr></table>

<table><tr><td>Command</td><td>IPMI/PICMG/AMC Spec</td><td>NetFn</td><td>CMD</td><td>MMC Req</td></tr><tr><td colspan="5">AdvancedTCA $^{\text{TM}}$  Commands</td></tr><tr><td>Get PICMG Properties</td><td>3-9</td><td>PICMG</td><td>00h</td><td>Mandatory</td></tr><tr><td>FRU Control</td><td>3-22</td><td>PICMG</td><td>04h</td><td>Mandatory</td></tr><tr><td>Get FRU LED Properties</td><td>3-24</td><td>PICMG</td><td>05h</td><td>Mandatory</td></tr><tr><td>Get LED Color Capabilities</td><td>3-25</td><td>PICMG</td><td>06h</td><td>Mandatory</td></tr><tr><td>Set FRU LED State</td><td>3-26</td><td>PICMG</td><td>07h</td><td>Mandatory</td></tr><tr><td>Get FRU LED State</td><td>3-27</td><td>PICMG</td><td>08h</td><td>Mandatory</td></tr><tr><td>Get Device Locator Record ID</td><td>3-29</td><td>PICMG</td><td>0Dh</td><td>Mandatory</td></tr><tr><td colspan="5">AMC $^{\text{®}}$  Commands</td></tr><tr><td>Set AMC Port State</td><td>3-27</td><td>PICMG</td><td>19h</td><td>Mandatory</td></tr><tr><td>Get AMC Port State</td><td>3-28</td><td>PICMG</td><td>1Ah</td><td>Mandatory</td></tr></table>

Table 7-4: Supported IPMI Commands

This page intentionally left blank.

# Important Safety Instructions

Please read and follow all instructions marked on the product and in the documentation before operating the system. Retain all safety and operating instructions for future use.

▶ Please read these safety instructions carefully.
$\triangleright$ Please keep this User's Manual for future reference.
▶ The equipment should be operated within the recommended operating temperature.
The equipment should be operated only from the type of power source indicated on the rating label. Make sure the voltage of the power source is correct when connecting the equipment to the power outlet.
If the user's equipment has a voltage selector switch, make sure that the switch is set to the proper position for the area. The voltage selector switch is set at the factory to the correct voltage.
▶ For pluggable equipment, ensure they are installed near a socket-outlet that is easily accessible.
- Secure the power cord to prevent unnecessary accidents. Do not place anything over the power cord.
▶ If the equipment will not be in use for long periods of time, disconnect the equipment from mains to avoid being damaged by transient overvoltage.
▶ All cautions and warnings on the equipment should be noted.
▶ Please keep this equipment away from humidity.
▶ Do not use this equipment near water or a heat source.
▶ Place this equipment on a reliable surface when installing. A drop or fall could cause injury.
▶ Never pour any liquid into the opening, this could cause fire or electrical shock.

▶ Openings in the case are provided for ventilation. Do not block or cover these openings. Make sure there is adequate space around the system for ventilation when setting up the work area. Never insert objects of any kind into the ventilation openings.
▶ To avoid electrical shock, always unplug all power and modem cables from the wall outlets before removing covers.
▶ Lithium Battery provided (real time clock battery)

"CAUTION - Risk of explosion if battery is replaced by an incorrect type. Dispose used batteries as instructed in the instructions"

▶ The equipment should be checked by service personnel if one of the following situation arises:

The power cord or plug is damaged.
▷ Liquid has penetrated the equipment.
The equipment has been exposed to moisture.
The equipment is not functioning or does not function according to the user's manual.
The equipment has been dropped and damaged.
▷ If the equipment has obvious sign of breakage.

▶ Never open the equipment. For safety reasons, the equipment should only be opened by qualified service personnel.

# Getting Service

Contact us should you require any service or assistance.

# ADLINK Technology, Inc.

Address: 9F, No.166 Jian Yi Road, Chungho City, Taipei County 235, Taiwan
台北縣中和市建一路 166 號 9 樓

Tel: +886-2-8226-5877

Fax: +886-2-8226-5717

Email: service@adlinktech.com

# Ampro ADLINK Technology, Inc.

Address: 5215 Hellyer Avenue, #110, San Jose, CA 95138, USA

Tel: +1-408-360-0200

Toll Free: +1-800-966-5200 (USA only)

Fax: +1-408-360-0222

Email: info@adlinktech.com

# ADLINK Technology Beijing

Address: 北京市海淀区上地东路 1 号盈创动力大厦 E 座 801 室(100085)
Rm. 801, Power Creative E, No. 1, B/D
Shang Di East Rd., Beijing, 100085 China

Tel: +86-10-5885-8666

Fax: +86-10-5885-8625

Email: market@adlinktech.com

# ADLINK Technology Shanghai

Address: 上海市漕河泾高科技开发区钦江路 333 号 39 幢 4 层 (200233)
4F, Bldg 39, Caoheting Science & Technology Park,
No.333 Qinjiang Rd., Shanghai, 200233 China

Tel: +86-21-6495-5210

Fax: +86-21-5450-0414

Email: market@adlinktech.com

# ADLINK Technology Shenzhen

Address: 深圳市南山区科技园南区高新南七道 数字技术园
A1 栋 2 楼 C 区 (518057)
2F, C Block, Bldg. A1, Cyber-Tech Zone, Gao Xin Ave. Sec. 7,
High-Tech Industrial Park S., Shenzhen, 518054 China

Tel: +86-755-2643-4858

Fax: +86-755-2664-6353

Email: market@adlinktech.com

# ADLINK Technology, Inc. (German Liaison Office)

Address: Nord Carree 3, 40477 Duesseldorf, Germany

Tel: +49-211-495-5552

Fax: +49-211-495-5557

Email: emea@adlinktech.com

# ADLINK Technology, Inc. (French Liaison Office)

Address: 15 rue Emile Baudot, 91300 Massy CEDEX, France

Tel: +33 (0) 1 60 12 35 66

Fax: +33 (0) 1 60 12 35 66

Email: france@adlinktech.com

# ADLINK Technology Japan Corporation

Address: 151-0072 東京都渋谷区幡ヶ谷

1-1-2 朝日生命幡ヶ谷ビル 8F

Asahiseimei Hatagaya Bldg. 8F

1-1-2 Hatagaya, Shibuya-ku, Tokyo 151-0072, Japan

Tel: +81-3-4455-3722

Fax: +81-3-5333-6040

Email: japan@adlinktech.com

# ADLINK Technology, Inc. (Korean Liaison Office)

Address: 서울시 서초구 서초동 1506-25 한도 B/D 2 층

2F, Hando B/D, 1506-25, Seocho-Dong, Seocho-Gu,

Seoul 137-070, Korea

Tel: +82-2-2057-0565

Fax: +82-2-2057-0563

Email: korea@adlinktech.com

# ADLINK Technology Singapore Pte. Ltd.

Address: 84 Genting Lane #07-02A, Cityneon Design Centre, Singapore 349584

Tel: +65-6844-2261

Fax: +65-6844-2263

Email: singapore@adlinktech.com

# ADLINK Technology Singapore Pte. Ltd. (Indian Liaison Office)

Address: No. 1357, "Anupama", Sri Aurobindo Marg, 9th Cross, JP Nagar Phase I, Bangalore - 560078, India

Tel: +91-80-65605817

Fax: +91-80-22443548

Email: india@adlinktech.com
[🔗 Link to the original document](.amc-7100-50-1z004-1000-200/amc-7100-50-1z004-1000-200.pdf)