# AXE-7420GWA

# User’s Manual

4U Short-depth AI GPU Server with Intel® Xeon® 600 Processors for Workstations

![Front view of a server rack unit with hexagonal ventilation slots and drive ports (no visible text or labels)](.axe-7420gwa-50m-22811-1000-02/f8bee5ef363d767a12303178ba000ea0c3652d82ba26addc2c35db6ff5a7b29b.jpg)

Manual Rev.: 0.2 Preliminary

Revision Date: June 15, 2026

Part Number: 50M-22811-1000

# Preface

# Copyright

Copyright 2026 ADLINK Technology, Inc. This document contains proprietary information protected by copyright. All rights are reserved. No part of this manual may be reproduced by any mechanical, electronic, or other means in any form without prior written permission of the manufacturer.

# Disclaimer

The information in this document is subject to change without prior notice in order to improve reliability, design, and function and does not represent a commitment on the part of the manufacturer. In no event will the manufacturer be liable for direct, indirect, special, incidental, or consequential damages arising out of the use or inability to use the product or documentation, even if advised of the possibility of such damages.

# Environmental Responsibility

ADLINK is committed to fulfill its social responsibility to global environmental preservation through compliance with the European Union's Restriction of Hazardous Substances (RoHS) directive and Waste Electrical and Electronic Equipment (WEEE) directive. Environmental protection is a top priority for ADLINK. We have enforced measures to ensure that our products, manufacturing processes, components, and raw materials have as little impact on the environment as possible. When products are at their end of life, our customers are encouraged to dispose of them in accordance with the product disposal and/or recovery programs prescribed by their nation or company.

![Symbol of a trash bin crossed with two crossed lines and a solid rectangle below (no text or labels)](.axe-7420gwa-50m-22811-1000-02/5a00dd3f139b4a4a3bb286280e4771231a872933ad42df42c5cb9708d101bf8e.jpg)

Battery Labels (for products with battery)

![Simple line drawing of a trash bin crossed out by two diagonal lines (no text or symbols)](.axe-7420gwa-50m-22811-1000-02/e2dbbe97eecc73eb6fe940aa1c5df7994d6df32885d0a8a5ed1caf48a07a3679.jpg)

![The image displays a black recycling symbol featuring three chasing arrows enclosed within a square border. Directly below the square, the text 'Li-ion' appears in bold, black letters.](.axe-7420gwa-50m-22811-1000-02/79afcccce23dcbc8c8fb112efc5268f924200345be962cd917ef878dadf16eba.jpg)

![RECYCLE\nRBRC\nLi-ion\n1.800.822.8837](.axe-7420gwa-50m-22811-1000-02/c14408a8546f259d28e4429a2d3585a183872a8dfe0bd6f365b822fd2893dea2.jpg)

![廢電池請回收](.axe-7420gwa-50m-22811-1000-02/95f5184f8f0ee98bbdbe530d93fbf07e5cb3312bf3180e5687c820744a736ae7.jpg)

# California Proposition 65 Warning

![The image displays a standard warning sign featuring a yellow triangle with a thick black border. Inside the triangle, centered, is a black exclamation mark.](.axe-7420gwa-50m-22811-1000-02/0408a6b44aadd794da568b1f667c04d814153211e49c11c0f4a991681eeef457.jpg)

WARNING: This product can expose you to chemicals including acrylamide, arsenic, benzene, cadmium, Tris(1,3-dichloro-2-propyl)phosphate (TDCPP), 1,4-Dioxane, formaldehyde, lead, DEHP, styrene, DINP, BBP, PVC, and vinyl materials, which are known to the State of California to cause cancer, and acrylamide, benzene, cadmium, lead, mercury, phthalates, toluene, DEHP, DIDP, DnHP,

DBP, BBP, PVC, and vinyl materials, which are known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.

# Trademarks

Product names mentioned herein are used for identification purposes only and may be trademarks and/or registered trademarks of their respective companies.

# Conventions

Take note of the following conventions used throughout this manual to make sure that users perform certain tasks and instructions properly.

![The image is a square icon enclosed by a black border. It depicts a white document resembling a piece of paper with a folded top-right corner. Faint gray horizontal lines are visible on the document, simulating text. A large, bold red checkmark is superimposed over the document, angled from the bottom left to the top right.](.axe-7420gwa-50m-22811-1000-02/a2cddcc167136a624718ad0f8e6c7deab5a3bdc22afb7c8648a0892e08a8089c.jpg)
NOTE:

Additional information, aids, and tips that help users perform tasks.

![The image shows a yellow triangle with a black border containing a large black exclamation point in the center.](.axe-7420gwa-50m-22811-1000-02/2463727f5b325c187893d46fb8b64bea2604e4bc14ca787763028f2b7c1ce0a6.jpg)
CAUTION:

Information to prevent minor physical injury, component damage, data loss, and/or program corruption when trying to complete a task.

![A red triangle containing a white exclamation point.](.axe-7420gwa-50m-22811-1000-02/80e8da517c243d69ab688c940f4139f01d4ac858ebec2f10d1d55e01f1d63aa4.jpg)
WARNING:

Information to prevent serious physical injury, component damage, data loss, and/or program corruption when trying to complete a specific task.

# Revision History

<table><tr><td>Revision</td><td>Description</td><td>Date</td><td>By</td></tr><tr><td>0.1</td><td>Preliminary release</td><td>2026-05-05</td><td>AL</td></tr><tr><td>0.2</td><td>Specifications, block diagram, and BIOS setup updated</td><td>2026-06-15</td><td>AL</td></tr></table>

# Table of Contents

# Preface...

# List of Figures .... .vii

# List of Tables...... .viii

# 1 Introduction....

1.1 Features...
1.2 Packing List .
1.3 Optional Accessories .

# Specifications ...

# Functional Block Diagram .......

# 4 Mechanical Layout ..

4.1 Mechanical Dimensions . 7
4.2 Server Layout .. .8
4.3 Connector Locations .. ..10

# Connector Pinouts and Jumper Settings ...... .11

5.1 Rear I/O Connectors . .11
5.2 Onboard Headers and Connectors.. ..18
5.3 Jumper and Switch Settings....... ..27
5.4 Expansion Slots .31

# Getting Started....... .45

6.1 Installing Memory Modules . ..45
6.2 PCIe Slot Secondary Power Supply.. ..46
6.3 BMC LAN Configuration.. ..46
6.4 BIOS Update... ..47
6.5 BMC Firmware Update via Network . ..47
6.6 CPLD Update... ..47
6.7 Create a RAID Volume... ..48

# 7 BIOS Settings..... .49

7.1 BIOS Setup Menu.. .Error! Bookmark not defined.
7.2 Main Menu.. .Error! Bookmark not defined.
7.3 Advanced Menu.... .Error! Bookmark not defined.
7.4 Chipset Menu.... .Error! Bookmark not defined.
7.5 Security Menu... .Error! Bookmark not defined.
7.6 Boot Menu . .Error! Bookmark not defined.
7.7 Save & Exit Menu . .Error! Bookmark not defined.

7.8 Server Management . .Error! Bookmark not defined.
7.9 View System Event Log .. .Error! Bookmark not defined.
7.10 BMC User Settings . .Error! Bookmark not defined.
7.11 BMC Warm Reset.. .Error! Bookmark not defined.

# 8 BMC .... ..89

8.1 BMC Introduction .... ..89
8.2 Web GUI Introduction.. ..90
8.3 IPMI . ..141
8.4 Redfish . .151

# Safety Instructions... ..182

# Consignes de Sécurité Importantes.. ..184

# FCC Warning ........ ..186

# Getting Service............ ....187

# List of Figures

Figure 1: Functional block diagram.. 5
Figure 2: Mechanical dimensions ..
Figure 3: AXE-7420GWA rear panel . .8
Figure 4: AXE-7420GWA front panel.. .9
Figure 5: Onboard LED indicators . ..10
Figure 6: Jumper and switch locations . .27
Figure 7: Expansion slot block diagram.. ..31

# List of Tables

Table 1: Motherboard layout descriptions. ..10

# Introduction

ADLINK AXE-7420GWA is a 4U 19" rackmount edge computing server/workstation system powered by 6thgeneration Intel® Xeon™ 600 workstation processors with Intel® W890 chipset. For providing rich IO expansion, there are 12x PCIe slots on chassis, up to 8x 2.5” storage bay and 1x 3.5” storage bay.

It also features high-speed data transfer interfaces such as PCIe 5.0, USB 3.2 Gen 2, and SATA 6 Gb/s (SATA III), along with quad-channel DDR5 memory supporting up to 6400 MT/s for edge AI applications.

With an abundant I/O port design and high-speed data transfer interfaces, the AXE-7420GWA provides a significant competitive advantage for edge AI computing in terms of device compatibility, durable connectivity, and readiness for extreme environments.

# 1.1 Features

The main features of the AXE-7420GWA as follows:

• 4U chassis with a single Intel® Xeon® 600 Processors for Workstations, up to 350W TDP
• 12-slot expansion design, including 4x PCIe x16(1x via MICO) & 2x PCIe x8 & 2x PCIe x4
Up to 4x GPU cards with extension board
Up to 11x PCIe slots with extension board
8x 2.5” SATA SSD
3x Internal fan modules & 2x optional external fan modules
Supports a single Intel® Granite Rapids-Workstation family processor
8× DDR5 DIMMs, up to 6400 MT/s (4 channels, 1DPC)
• Supports up to 11 PCIe slots with extension board, including 3× PCIe x16 slots
Supports up to 4 MCIO connectors
Onboard VGA and DisplayPort (DP) ports
• 1× 1GbE (Intel® I210) and 1× 2.5GbE (Intel® I226); supports Wake-on-LAN (WOL) and PXE boot
BMC with AST2600, compliant with IPMI v2.0 and Redfish
Dimension: 550mm(L) x 438mm(W) x 176mm(H)

# 1.2 Packing List

• AXE-7420GWA bare bone
CPU cooler
Power code

# 1.3 Optional Accessories

• 2-bay SlimSAS storage (Part Number: 29-0450A-0000)
• 8-bay 2.5 Inch SATA/SAS 6Gbps Hard Drive kit (Part Number: 29-04300-0000)
• 1-slot PCIex16 extension (Part Number: xxx)
• 4-slots PCIe extension board, 2x PCIex8, 2PCIex4 (55-37233-000E)
• 2-port USB 2.0 cable with bracket (Part Number: 30-25010-3010)
• 2-port USB 3.0 cable with bracket (Part Number: 30-25046-0100)
• 2-port COM cable with bracket (Part Number: 30-25116-0000-A0)

This page intentionally left blank.

Specifications

<table><tr><td rowspan="4">System</td><td>Form Factor</td><td>4U 19" Rackmount</td></tr><tr><td>Dimension (WxDxH)</td><td>438 x 550 x 177mm (17.23 x 21.65 x 6.95 inch)</td></tr><tr><td>Gross Weight</td><td>21.4kg (47.18 lbs)</td></tr><tr><td>Net Weight</td><td>18.1kg (39.90 lbs)</td></tr><tr><td rowspan="3">Processor</td><td>Socket Type</td><td>Socket E2, LGA 4710 socket</td></tr><tr><td>Support CPU Series</td><td>Single Intel® Xeon® 600 Processors for Workstations, up to 350W TDP</td></tr><tr><td>TDP</td><td>Support up to 350W</td></tr><tr><td>Chipset</td><td>PCH</td><td>W890</td></tr><tr><td>GPU</td><td>Type</td><td>3x FHFL GPU Gen5 x16</td></tr><tr><td rowspan="3">Memory</td><td>Slot Count</td><td>8x DIMM slots</td></tr><tr><td>Capacity</td><td>1TB, 128GBx 8 slot(note)</td></tr><tr><td>DIMM Type/Speed</td><td>4 Channel DDR5, 8 slots DDR5 RDIMM ECC Memory speed: Up to 6400MT/S (1DPC), 5200 MT/S (2DPC)</td></tr><tr><td rowspan="2">Storage</td><td>SATA</td><td>4x SATA III slots, SATA RAID 0/1/5/10 supported by PCH or Up to 8x SATA III slots, SATA RAID 0/1/5/10 supported by PCH (optional)</td></tr><tr><td>M.2 (2242/2280)</td><td>2x M.2(M-Key) NVMe #1 support 2280/22110/25110 #2 support 2280/22110</td></tr><tr><td>PCIe Expansion Slot</td><td>Configuration</td><td>Expert stream (128L): 3x PCIe 5.0 x16 2x PCIe 5.0 x8 2x PCIe 5.0 x4 Mainstream (80L): 2x PCIe 5.0 x16 2x PCIe 5.0 x8 2x PCIe 5.0 x4</td></tr><tr><td>Cooling</td><td>System Fan</td><td>3x fan modules (80x38 fan) 1x fan modules in rear end (60x 25 fan)</td></tr><tr><td rowspan="5">Power Supply</td><td>PSU Type</td><td>ATX PS2</td></tr><tr><td>Efficiency</td><td>80 Plus Titanium</td></tr><tr><td>Output Watts</td><td>1650W</td></tr><tr><td>Voltage</td><td>100V to 240V AC @50-60Hz</td></tr><tr><td>Redundancy</td><td>1+1</td></tr><tr><td rowspan="3">Front I/O</td><td>LEDs</td><td>Power on x1, system event x1, thermal alarm x1</td></tr><tr><td>USB</td><td>2x USB 2.0</td></tr><tr><td>Others</td><td>1x Power button 1x Reset hole</td></tr><tr><td rowspan="5">Rear I/O</td><td>LAN</td><td>1x 1Gb RJ45 Ethernet port (shared with IPMI Management LAN) 1x 2.5Gb RJ45 Ethernet port</td></tr><tr><td>COM</td><td>1x DB-9 COM connector with RS-232/422/485</td></tr><tr><td>USB</td><td>5x Type A USB3.2 Gen2 10Gbps 1x Type C USB3.2 Gen2 10Gbps</td></tr><tr><td>Graphic</td><td>1x D-Sub 15-pin VGA port 1x DP port</td></tr><tr><td>Button</td><td>1x Clear CMOS reset hole button</td></tr><tr><td>Security</td><td>TPM (Optional)</td><td>TPM 2.0 module SPI</td></tr><tr><td>BMC Controller</td><td>Chipset</td><td>ASPEED AST2600 with IPMI 2.0 and Redfish support</td></tr><tr><td>BIOS</td><td>Chipset</td><td>AMI BIOS on SPI flash memory</td></tr><tr><td>Environment</td><td>Temperature</td><td>Operating: 0°C to +40°C · Storage: -40°C to +70°C Relative Humidity: 10%–85% (long term), 5%–90% (short term)</td></tr><tr><td>Operation system</td><td>OS</td><td>Windows® 11 LTSC (64 bit)Ubuntu 24.04 (64 bit)</td></tr></table>

![The image displays a simple icon featuring a white sheet of paper with its top-left corner folded down (a 'dog-ear'). Faint horizontal lines run across the lower portion of the paper. A large, bold red checkmark is superimposed over the center of the document, angled slightly upward from left to right.](.axe-7420gwa-50m-22811-1000-02/c517f42816691d9d1924bad8904544028ff3c490a1d69af1f041955a52aa92c2.jpg)
NOTE:

\* Follow the latest Intel® Memory POR

# Functional Block Diagram

![Based on the provided flowchart, here is the accurate and concise description of the labeled blocks and their connections:\n\n**Power and Memory Section (Top Left)**\n*   **Blocks:** 'CRPS Redundant PSUs Supports 12V DC input', 'ATX Connector 24P x4', 'ATX Connector 8P x4', 'DDR5 RDIMM 5200 MT/s (2DPC) 4 Channel 2DPC configuration Max System Capacity ~2TB', 'DDR5 RDIMM slot x2' (repeated 4 times).\n*   **Connections:**\n    *   'CRPS Redundant PSUs...' connects to 'ATX Connector 24P x4' and 'ATX Connector 8P x4' via 'Power/PMBus'.\n    *   'DDR5 RDIMM 5200...' connects to four 'DDR5 RDIMM slot x2' blocks.\n    *   Each 'DDR5 RDIMM slot x2' connects via 'DDR5' to 'CHA', 'CHC', 'CHE', and 'CHG' respectively.\n\n**Processor and PCIe Expansion Section (Top Center & Right)**\n*   **Blocks:** 'Processor Intel CPU Socket E2 LGA 4710 (Granite Rapids Expert + Mainstream Workstation, TDP 350W)', 'PCIe x16 CEM-Slot4', 'PCIe x16 CEM-Slot1', 'MCIO x8 74P x2' (repeated), 'MCIO 1&2', 'MCIO 3&4', 'PCIe x16 CEM-Slot7', 'PCIe x4 CEM-Slot6', 'PCIe x8 CEM-Slot5', 'M .2_2280/22110/25110', 'PCIe x8 CEM-Slot3', 'PCIe x8 CEM-Slot2', 'M .2_2280/22110', 'TPM pin header', 'TPM Module INFINEON TPM 2.0 SLM 9670AQ2.0'.\n*   **Connections:**\n    *   'Processor' connects to 'PCIe x16 CEM-Slot4' via 'PE6' and 'PCIe Gen5 x16'.\n    *   'Processor' connects to 'PCIe x16 CEM-Slot1' via 'PE8' and 'PCIe Gen5 x16'.\n    *   'Processor' connects to 'MCIO 3&4' via 'PE7', 'PCIe Gen5 x16', and 'MCIO x8 74P x2'.\n    *   'Processor' connects to 'MCIO 1&2' via 'PE3', 'PCIe Gen5 x16', and 'MCIO x8 74P x2'.\n    *   'Processor' connects to 'PCIe x16 CEM-Slot7' via 'PE0' and 'PCIe Gen5 x16'.\n    *   'Processor' connects to 'PCIe x4 CEM-Slot6' via 'PE0' and 'PCIe Gen5 x4'.\n    *   'Processor' connects to 'PCIe x8 CEM-Slot5' via 'PE2' and 'PCIe Gen5 x8'.\n    *   'Processor' connects to 'M .2_2280/22110/25110' via 'PE0' and 'PCIe Gen5 x4'.\n    *   'Processor' connects to 'PCIe x8 CEM-Slot3' via 'PE0' and 'PCIe Gen5 x4'.\n    *   'Processor' connects to 'PCIe x8 CEM-Slot2' via 'PE2' and 'PCIe Gen5 x8'.\n    *   'Processor' connects to 'M .2_2280/22110' via 'PE0' and 'PCIe Gen5 x4'.\n    *   'Processor' connects to 'TPM pin header' via 'SPI'.\n    *   'TPM pin header' connects to 'TPM Module INFINEON TPM 2.0 SLM 9670AQ2.0'.\n\n**Central Hub (W890) and Peripherals**\n*   **Blocks:** 'W890', 'Microphone Speaker 3.5mm Jack', 'Mic-in', 'Line-in', 'Line-out', 'Codec Realtek ALC897', 'MDI', 'Intel Ethernet Controller I226-V', 'PCIe Gen3 x1', 'HDA', '2.5G BaseT RJ45 + 2x1 Type-A USB3', '2x USB3.2', '2x USB2.0', 'TI TUSB1002AIRGER USB 3.2 Re-driver', 'USB3.2 Gen2', 'USB2.0/1.1', '1G BaseT RJ45 + 2x1 Type-A USB3', 'TI TUSB1002AIRGER USB 3.2 2P Re-driver', 'USB Type-C 10G + USB 3 Type A', 'U3#1', 'U3#2', 'U3#3', 'U3#6', '8x 7pin SATA3 Header', 'SATA#0~7', 'VROC Header', 'GPP F23'.\n*   **Connections:**\n    *   'W890' connects to 'Processor' via 'DMI Gen4 x8' and 'eSPI'.\n    *   'Microphone Speaker 3.5mm Jack' connects via 'Mic-in', 'Line-in', 'Line-out' to 'Codec Realtek ALC897'.\n    *   'Codec Realtek ALC897' connects via 'MDI' to 'Intel Ethernet Controller I226-V'.\n    *   'Intel Ethernet Controller I226-V' connects via 'PCIe Gen3 x1' to 'W890' (labeled 'PCIe#3' and 'HDA').\n    *   '2.5G BaseT RJ45 + 2x1 Type-A USB3' connects via '2x USB3.2' and '2x USB2.0' to 'TI TUSB1002AIRGER USB 3.2 Re-driver'.\n    *   'TI TUSB1002AIRGER USB 3.2 Re-driver' connects via 'USB3.2 Gen2', 'USB2.0/1.1', 'USB3.2 Gen2' to 'W890' (labeled 'U3#2').\n    *   '1G BaseT RJ45 + 2x1 Type-A USB3' connects via '2x USB3.2' and '2x USB2.0' to 'TI TUSB1002AIRGER USB 3.2 2P Re-driver'.\n    *   'TI TUSB1002AIRGER USB 3.2 2P Re-driver' connects via 'USB2.0/1.1', 'USB3.2 Gen2' to 'W890' (labeled 'U3#6').\n    *   'USB Type-C 10G + USB 3 Type A' connects via 'USB3.2 Gen2', 'USB2.0/1.1', 'USB3.2 Gen2', 'USB2.0/1.1' to 'TI TUSB1002AIRGER USB 3.2 Re-driver'.\n    *   'TI TUSB1002AIRGER USB 3.2 Re-driver' connects via 'USB2.0/1.1', 'USB3.2 Gen2', 'USB2.0/1.1' to 'W890' (labeled 'U3#1').\n    *   'USB Type-C 10G + USB 3 Type A' connects via 'USB2.0/1.1', 'USB3.2 Gen2', 'USB2.0/1.1' to 'TI TUSB1002AIRGER USB 3.2 Re-driver'.\n    *   'TI TUSB1002AIRGER USB 3.2 Re-driver' connects via 'USB2.0/1.1', 'USB3.2 Gen2', 'USB2.0/1.1' to 'W890' (labeled 'U3#2').\n    *   '8x 7pin SATA3 Header' connects via 'SATA#0~7' to 'W890'.\n    *   'VROC Header' connects via 'GPP F23' to 'W890'.\n\n**Server IPMC and Headers Section (Bottom Right)**\n*   **Blocks:** 'Server IPMC ASPEED AST2600', 'PCIe#9~12', 'PCIe Gen4 x4', 'SlimSAS 1', 'PCIe#21~24', 'SlimSAS 2', 'U3#7~10', 'USB2.0/1.1', 'USB3.2 Gen1', 'USB3.2 x4 Header', 'USB3.2 x4', 'U2#11~12', 'USB2.0 x2', 'U3#3', 'NC-SI', 'To I210-IT', 'PCIe#7', 'MDI', 'To AST2600', 'U2#13~14', 'KCS/Redfish', 'I2C/SMBus', 'I2C', 'Nuvoton NCT6126D', 'UART', 'PCIe#4', 'PCIe Gen2 x1', 'DISPLAY PORT', 'DP connector', 'VGA', 'DBG UART', 'IPMC Header', 'GPIOs', 'UID/Reset/Power button', 'Front panel', 'PWM/TACH', '48W Fan x2', 'System Fan x4', 'CPU Fan', 'UARTx2', 'RS485 Transceiver x2 EXAR SP339', 'COMx1', '2x1 D-SUB connector', 'UARTx3', 'RS232 Transceiver ADM213EARSZ', 'COMx4', 'COM x5 Header', 'SPI Switch', 'BIOS Flash 64MB', 'SPI', 'eSPI'.\n*   **Connections:**\n    *   'W890' connects to 'Server IPMC ASPEED AST2600' via 'PCIe Gen2 x1' (from 'PCIe#4').\n    *   'W890' connects to 'SlimSAS 1' via 'PCIe#9~12' and 'PCIe Gen4 x4'.\n    *   'W890' connects to 'SlimSAS 2' via 'PCIe#21~24' and 'PCIe Gen4 x4'.\n    *   'W890' connects to 'USB3.2 x4 Header' via 'U3#7~10' and 'USB3.2 Gen1' (and 'USB2.0/1.1').\n    *   'USB3.2 x4 Header' connects via 'USB3.2 x4' to 'USB3.2 x4 Header'.\n    *   'W890' connects to 'USB2.0 x2' via 'U2#11~12'.\n    *   'W890' connects to 'USB2.0 x2' via 'U3#7~10' and 'USB2.0/1.1'.\n    *   'W890' connects to 'To I210-IT' via 'U3#3' and 'NC-SI'.\n    *   'W890' connects to 'To AST2600' via 'PCIe#7' and 'MDI'.\n    *   'W890' connects to 'SPI Switch' via 'U3#6' and 'SPI'.\n    *   'SPI Switch' connects to 'BIOS Flash 64MB' via 'SPI'.\n    *   'BIOS Flash 64MB' connects to 'Server IPMC' via 'SPI'.\n    *   'W890' connects to 'Server IPMC' via 'U2#13~14' and 'KCS/Redfish'.\n    *   'W890' connects to 'Nuvoton NCT6126D' via 'I2C/SMBus' and 'I2C'.\n    *   'Nuvoton NCT6126D' connects to 'Server IPMC' via 'UART'.\n    *   'Server IPMC' connects to 'DP connector' via 'DISPLAY PORT'.\n    *   'Server IPMC' connects to 'VGA' via 'VGA'.\n    *   'Server IPMC' connects to 'IPMC Header' via 'DBG UART'.\n    *   'Server IPMC' connects to 'UID/Reset/Power button' and 'Front panel' via 'GPIOs'.\n    *   'Server IPMC' connects to '48W Fan x2', 'System Fan x4', and 'CPU Fan' via 'PWM/TACH'.\n    *   'Server IPMC' connects to '2x1 D-SUB connector' via 'UARTx2', 'RS485 Transceiver x2 EXAR SP339', and 'COMx1'.\n    *   'Server IPMC' connects to 'COM x5 Header' via 'UARTx3', 'RS232 Transceiver ADM213EARSZ', and 'COMx4'.\n\n**Legend (Top Right)**\n*   **Blocks:** 'Key IC', 'Internal connector', 'I/O', 'Expert Workstation SKU'.\n*   **Connections:** 'Expert Workstation SKU' is an arrow pointing to the right.](.axe-7420gwa-50m-22811-1000-02/9daf4e86b2586a9ab00b9fa23cb11052ba7a027f2b961398408b53f29af297d7.jpg)

Figure 1: Functional block diagram

This page intentionally left blank.

# Mechanical Layout

# 4.1 Mechanical Dimensions

![The image displays a technical engineering drawing of a server chassis featuring five orthographic projections with dimensional annotations:\n\n*   **Top View:** Shows the rear panel with fans and I/O ports, marked with a width of **438.00**.\n*   **Middle Left View:** A side profile view indicating a total height of **550.00**, a horizontal hole spacing of **76.00**, and a small bottom dimension of **7.00**.\n*   **Middle Center View:** A large side panel view showing internal mounting holes, marked with a width of **438.00**.\n*   **Middle Right View:** A side profile view featuring a hexagonal vent pattern, marked with a width of **176.00**.\n*   **Bottom View:** The front panel view showing drive bays and a control area with small text labels reading **SYS** and **TEMP**.](.axe-7420gwa-50m-22811-1000-02/c3e5743a3ae661d7bfda77221305beab09d4eeeafa412edb8460ae74ef33db82.jpg)
Figure 2: Mechanical dimensions

# 4.2 Server Layout

# AXE-7420GWA Rear Panel

![2.5 Gb LAN\nDP\nCOM\n1Gb LAN\nAudio\nPSU\nClear CMOS reset hole\nVGA\nUSB3.2 Gen2\nUSB3.2 Type C\nPCIE Slot](.axe-7420gwa-50m-22811-1000-02/73ec486f7fe3c1a233fb5c0172313dfe604e5048ccf1a6c784e26d4ddf212ec2.jpg)

Figure 3: AXE-7420GWA rear panel

# AXE-7420GWA Front Panel

![System event LED\nThermal alarm LED\nSYS\nTEMP\n5.25' Bay\n3.3' Bay\nUSB 2.0\nPower button Reset button](.axe-7420gwa-50m-22811-1000-02/c787dcb24613fd4c2a382b3d5247b6b48169e41311a184e40bcc9b1083c6b447.jpg)

Figure 4: AXE-7420GWA front panel

# 4.3 Connector Locations

![Circuit board layout diagram with numbered components and labeled slots, likely for a computer or hardware assembly.](.axe-7420gwa-50m-22811-1000-02/8295c136dd919910130c135e96ad84a88351f0e84131d11a95163830d510a325.jpg)

Figure 5: Onboard LED indicators

Table 1: Motherboard layout descriptions

<table><tr><td>No.</td><td>Description</td></tr><tr><td>1</td><td>Clear CMOS reset hole</td></tr><tr><td>2</td><td>System Fan</td></tr><tr><td>3</td><td>System Fan</td></tr><tr><td>4</td><td>DP connector</td></tr><tr><td>5</td><td>COM+VGA</td></tr><tr><td>6</td><td>2.5Gb LAN + USB3.2 Gen2</td></tr><tr><td>7</td><td>1Gb LAN+USB 3.2 Gen2</td></tr><tr><td>8</td><td>USB3.2 Gen2 + Type C</td></tr><tr><td>9</td><td>Audio</td></tr><tr><td>10</td><td>System Fan</td></tr><tr><td>11</td><td>System Fan</td></tr><tr><td>12</td><td>PCIe x16</td></tr><tr><td>13</td><td>PCIe x8</td></tr><tr><td>14</td><td>PCIe x4 with x8 connector</td></tr><tr><td>15</td><td>PCIex16</td></tr><tr><td>16</td><td>PCIex8</td></tr><tr><td>17</td><td>PCIex4</td></tr><tr><td>18</td><td>PCIex16</td></tr><tr><td>19</td><td>XDP (for debug)</td></tr><tr><td>20</td><td>CPU fan</td></tr><tr><td>21</td><td>Case open detection</td></tr><tr><td>22</td><td>CPU Power connector</td></tr><tr><td>23</td><td>DDR5 slot</td></tr></table>

<table><tr><td>No.</td><td>Description</td></tr><tr><td>24</td><td>DDR5 slot</td></tr><tr><td>25</td><td>DDR5 slot</td></tr><tr><td>26</td><td>DDR5 slot</td></tr><tr><td>27</td><td>CRPS power board header</td></tr><tr><td>28</td><td>DIDO header</td></tr><tr><td>29</td><td>IPMB header</td></tr><tr><td>30</td><td>USB3.2 Gen1 header</td></tr><tr><td>31</td><td>USB3.2 Gen1 header</td></tr><tr><td>32</td><td>CPU</td></tr><tr><td>33</td><td>VROC</td></tr><tr><td>34</td><td>COM port</td></tr><tr><td>35</td><td>CMOS battery</td></tr><tr><td>36</td><td>PCH-W890</td></tr><tr><td>37</td><td>M.2 connector</td></tr><tr><td>38</td><td>80 port display</td></tr><tr><td>39</td><td>COM port</td></tr><tr><td>40</td><td>COM port</td></tr><tr><td>41</td><td>COM port</td></tr><tr><td>42</td><td>DDR5 slot</td></tr><tr><td>43</td><td>DDR5 slot</td></tr><tr><td>44</td><td>DDR5 slot</td></tr><tr><td>45</td><td>DDR5 slot</td></tr><tr><td>46</td><td>M.2 connector</td></tr></table>

<table><tr><td>No.</td><td>Description</td></tr><tr><td>47</td><td>COM port</td></tr><tr><td>48</td><td>CPU Power connector</td></tr><tr><td>49</td><td>USB 2.0 header</td></tr><tr><td>50</td><td>SlimSAS</td></tr><tr><td>51</td><td>ESPI header</td></tr><tr><td>52</td><td>SMBus header</td></tr><tr><td>53</td><td>CPLD JTAG header</td></tr><tr><td>54</td><td>SGPIO header</td></tr><tr><td>55</td><td>MCIO connector</td></tr><tr><td>56</td><td>MCIO connector</td></tr><tr><td>57</td><td>MCIO connector</td></tr><tr><td>58</td><td>MCIO connector</td></tr><tr><td>59</td><td>ATX Power connector</td></tr><tr><td>60</td><td>System Fan</td></tr><tr><td>61</td><td>System Fan</td></tr><tr><td>62</td><td>SlimSAS</td></tr><tr><td>63</td><td>PCIe power connector</td></tr><tr><td>64</td><td>PCIe power connector</td></tr><tr><td>65</td><td>SATA III x2</td></tr><tr><td>66</td><td>SATA III x2</td></tr><tr><td>67</td><td>SATA III x2</td></tr><tr><td>68</td><td>SATA III x2</td></tr><tr><td>69</td><td>Front Panel header</td></tr></table>

![The image shows a white document icon with a folded top-right corner and horizontal black lines running down the page. A large red checkmark is superimposed over the left side of the document. There is no text present in the image.](.axe-7420gwa-50m-22811-1000-02/8cfb9d438c59a55f9f5c4c19e6d5266dbc3f36951a2023a5b0860c4dfd39b10a.jpg)
NOTE:

Please ensure the correct pin definition when connecting the power cables.

# Connector Pinouts and Jumper Settings

# 5.1 Rear I/O Connectors

# Clear CMOS Reset Button

(SW2)

<table><tr><td>Signal</td><td>Pin</td></tr><tr><td>PCH_RTCRST-L</td><td>1</td></tr><tr><td>GND</td><td>2</td></tr><tr><td>GND</td><td>3</td></tr><tr><td>GND</td><td>4</td></tr></table>

![0.40\n(.016)\n0.70\n(.028)\n4.50\n(.177)\n7.00±0.50\n(.276±.020)\n8.50±0.40\n(.335±.016)\n1.80 ±0.3\n(.071±.03)\n4.00\n(.157)\n7.20\n(.283)\n3.50±0.50\n(.138±.020)](.axe-7420gwa-50m-22811-1000-02/b1cf2fcec50d0c1ea8d9ce574c88ee3ff0aa6679a9eb6edd121546a30d340e05.jpg)

![6.55\n(.258)\nØ3.50\n(.138)\n0.30\n(.012)\n2.55\n(.100)\nH\n0.70\n(.028)\n2.50\n(.098)\n4.00\n(.157)](.axe-7420gwa-50m-22811-1000-02/0835d0f04faf4b2cdf98016b5a8def9bde8f0bc467d2a6771784353770b315b6.jpg)

![The image shows a schematic labeled 'CIRCUIT DIAGRAM' at the bottom. It depicts two parallel horizontal branches.\n\nThe top branch connects a circle labeled 'T3' to a circle labeled 'T4' via a capacitor symbol (two parallel vertical lines). A line extends to the right from 'T4' and connects to a ground symbol, which is labeled 'GROUND TERMINAL'.\n\nThe bottom branch connects a circle labeled 'T1' to a circle labeled 'T2' via an open switch symbol.](.axe-7420gwa-50m-22811-1000-02/820d87757cf7b08b3e13cf1f487da46e2a10539d62eaf3409584af8c0ea432c7.jpg)

# DisplayPort Connector

(DP\_DDI1)
![Isometric line drawing of an electronic component housing (no text or symbols)](.axe-7420gwa-50m-22811-1000-02/1577faeb201496ca4abff466a3b479ec12b6956bcb61be2a342e218f485f7108.jpg)

![16.10 (.634)\n12.00 (.472)\n19-0.50 (.020)(PITCH)\nCL OF 16.10\nPIN 1\n4-0.40 (.016)\n20-0.20 (.008)\n2-0.120 (.047)\nPIN 20\n164±0.1 (.065±0.04)\nCL OF 12.00\n5-R0.30±0.2 (R.012±0.008)\n10.50 (.413)\nPIN 2\n4.76 (.187)\nPIN 19\n1.64±0.1 (.065±0.04)](.axe-7420gwa-50m-22811-1000-02/9c5470ee271e30fd6350f9178cd6de1efe6b5d6478a15d7f9840228de365d8a0.jpg)

![DP_DDI1\n1 ML_LANE_0P\n2 GND1\n3 ML_LANE_0N\n4 ML_LANE_1P\n5 GND2\n6 ML_LANE_1N\n7 ML_LANE_2P\n8 GND3\n9 ML_LANE_2N\n10 ML_LANE_3P\n11 GND4\n12 ML_LANE_3N\n13 CONFIG1\n14 CONFIG2\n15 AUX_CHP\n16 GND7\n17 AUX_CHN\n18 HPD\n19 RTN\n20 PWR\nDisplayPort_20\nN1 N2\n1 2\n1 9 20\nMTG1 MTG2 MTG3 MTG4\nG1 G2 G3 G4](.axe-7420gwa-50m-22811-1000-02/33b9b6e5a2d747b02fc813e369d4333bff931690135b1e33a19071f70082c048.jpg)

<table><tr><td>PIN#</td><td>Signal Name</td><td>PIN#</td><td>Signal Name</td></tr><tr><td>1</td><td>DDI2_PAIR0_P_Ch_CN</td><td>13</td><td>DP_CONN_CFG1(1M ohm to GND)</td></tr><tr><td>2</td><td>GND</td><td>14</td><td>DP_CONN_CFG2(1M ohm to GND)</td></tr><tr><td>3</td><td>DDI2_PAIR0_N_Ch_CN</td><td>15</td><td>DP_AUX_CONN_P</td></tr><tr><td>4</td><td>DDI2_PAIR1_P_Ch_CN</td><td>16</td><td>GND</td></tr><tr><td>5</td><td>GND</td><td>17</td><td>DP_AUX_CONN_N</td></tr><tr><td>6</td><td>DDI2_PAIR1_N_Ch_CN</td><td>18</td><td>CN_DDI2_HPD</td></tr><tr><td>7</td><td>NC</td><td>19</td><td>GND</td></tr><tr><td>8</td><td>GND</td><td>20</td><td>DP_3V3</td></tr><tr><td>9</td><td>NC</td><td>G1</td><td>GND</td></tr><tr><td>10</td><td>NC</td><td>G2</td><td>GND</td></tr><tr><td>11</td><td>GND</td><td>G3</td><td>GND</td></tr><tr><td>12</td><td>NC</td><td>G4</td><td>GND</td></tr></table>

# VGA+ DSUB(9P)

VGA\_COM1

![16.84±0.13\n( .663±.005 )\n2.77\n( .109 )\n1.385\n( .0545 )\n8.38±0.13\n( TYP.) \nPOS.1\n2.84\n( .112 )\n( TYP.)\n4-40 UNC\n( 4PL.) \nPOS.1\n19.05±0.25\n( .750±.010 )\n31.47±0.38\n( 1.239±.015 )\n1.98( .078 )\n1.98( .078 )\n2.29\n( .090 )\n( TYP.)\n1.145 ( .045 )\n( TYP.)\n0.25 ( .010 )\n16.31±0.13\n( .642±.005 )\n24.99±0.25\n( .984±.010 )\n30.81±0.38\n( 1.213±.015 )\n②\n③\n6.27±0.25\n( .247±.010 )\n3.90 ±0.18 ( .154 ± .006 )\n5](.axe-7420gwa-50m-22811-1000-02/45a4ca4c10056afccc1044266e0dfe660ef17db031ff793c7463f2fa27079290.jpg)

![5.97±0.13\n(.235±.005)\n①\n⑨\n⑧\n1.27±0.20\n(.050±.008)\n12.55±0.38\n(.494±.015)\n6.17±0.13\n(.243±.005)\n8.89±0.25\n(.350±.010)\n11.43±0.25\n(.450±.010)\n13.97±0.25\n(.550±.010)\n17.88±0.25\n(.704±.010)\n3.18±0.20\n(.125±.008)](.axe-7420gwa-50m-22811-1000-02/64718ea7735dc1b48f11402dec4634e9e9b8b87ff3b4b100db516028cbc96302.jpg)

![VGA COM1B\nUP   COM\n20\n24\n19\n23\n18\n22\n17\n21\n16\nD-SUB+H/D_9_F15](.axe-7420gwa-50m-22811-1000-02/a78502b1259330ce2a9f37137098afcee60a2d56d8760cf29516ae2eb2c93e43.jpg)

<table><tr><td>PIN#</td><td>Signal Name</td><td>PIN#</td><td>Signal Name</td></tr><tr><td>16</td><td>COM1_DCD-L</td><td>21</td><td>COM1_DSR-L</td></tr><tr><td>17</td><td>COM1_RXD</td><td>22</td><td>COM1_RTS-L</td></tr><tr><td>18</td><td>COM1_TXD</td><td>23</td><td>COM1_CTS-L</td></tr><tr><td>19</td><td>COM1_DTR-L</td><td>24</td><td>P_+5V_PSU/P_+12V_PSU</td></tr><tr><td>20</td><td>GND</td><td></td><td></td></tr></table>

![VGA COM1A\n| Pin Number | Label       |\n| ----------- | ----------- |\n| 25          | DOWN        |\n| 26          | VGA         |\n| 27          |           |\n| 28          |           |\n| 6           |             |\n| 1           |             |\n| 7           |             |\n| 2           |             |\n| 8           |             |\n| 3           |             |\n| 9           |             |\n| 4           |             |\n| 10          |             |\n| 5           |             |\n| 26          |             |\n|            | D-SUB+H/D_9_F15 |](.axe-7420gwa-50m-22811-1000-02/fa185604674d57a2f5e305d1b76d659066a86a39ff156e88252517b59844284c.jpg)

<table><tr><td>PIN#</td><td>Signal Name</td><td>PIN#</td><td>Signal Name</td></tr><tr><td>1</td><td>RED</td><td>13</td><td>CRT_HSYNC</td></tr><tr><td>2</td><td>GREEN</td><td>14</td><td>CRT_VSYNC</td></tr><tr><td>3</td><td>BLUE</td><td>15</td><td>SD_CLK</td></tr><tr><td>4</td><td>NC</td><td>25</td><td>GND</td></tr><tr><td>5</td><td>GND</td><td>26</td><td>GND</td></tr><tr><td>6</td><td>GND</td><td>27</td><td>GND</td></tr><tr><td>7</td><td>GND</td><td>28</td><td>GND</td></tr><tr><td>8</td><td>GND</td><td></td><td></td></tr><tr><td>9</td><td>P_+5V_PSU</td><td></td><td></td></tr><tr><td>10</td><td>GND</td><td></td><td></td></tr><tr><td>11</td><td>NC</td><td></td><td></td></tr><tr><td>12</td><td>SD_DATA</td><td></td><td></td></tr></table>

# 2.5G Base-T\_RJ45 + USB3.2 Gen2 x2

RJ45\_USB1
![Left LED\nC\nRight LED\nC8\nC1\n12.63 ±0.25\n4.13 ±0.25\n19.59 ±0.25\nU18\nU14\nU13\nU9\nU5\nU4\n0.2~0.6\nAfter Pre-Soldering\n0.45 ±0.08\nUSB\n12.7~14.2\n15.80 ±0.50\n18.55 ±0.38\n0.50 ±0.08 LED](.axe-7420gwa-50m-22811-1000-02/ae472a0171382da1b273edafa60c52ccdd9e09bc5cb0f5df85dc346ea2848d6d.jpg)

![L3\nOrange(橙)\n+\n+\nGreen(綠)\nL4](.axe-7420gwa-50m-22811-1000-02/15cb873e7ba87dbb7776384ab3f2e30e56903a6edf459897d71fc4ff43b16401.jpg)

![L1\nL2\nYellow(黄)](.axe-7420gwa-50m-22811-1000-02/60784ecb057c260829e8b3367f4e1ef50052834f907eb2611da2affde65bc8e4.jpg)

<table><tr><td>Emitting Color</td><td>λp (nm)</td><td>Vf @If=20mA</td><td>Ir @Vr=5V</td></tr><tr><td>Green</td><td>570</td><td>1.7 ~2.6 V</td><td>10μA max.</td></tr><tr><td>Orange</td><td>605</td><td>1.7 ~2.6 V</td><td>10μA max.</td></tr><tr><td>Yellow</td><td>588</td><td>1.7 ~2.6 V</td><td>10μA max.</td></tr></table>

![RJ45_USB1\nR2 TD1+\nR3 TD1-\nR4 TD2+\nR5 TD2-\nR6 TD3+\nR7 TD3-\nR8 TD4+\nR9 TD4-\nLAN\nL1\nL2\nL3\nL4\nR1 VCC GND_1\nU1 VBUS1 USB VBUS2 U10\nU2 DM1 DM2 U11\nU3 DP1 DP2 U12\nU4 GND_2 GND_4 U13\nU5 SSRXN1 SSRXN2 U14\nU6 SSRXP1 SSRXP2 U15\nU7 GND_3 GND_5 U16\nU8 SSTXN1 SSTXN2 U17\nU9 SSTXP1 SSTXP2 U18\nG G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G\nG1 G2 G3 G4 G5 G6 G7 G8 RJ45-USB3](.axe-7420gwa-50m-22811-1000-02/b06ba2ff1da5d185380c4e5012a324524c162af0e2ece8b0e58b69f5a8d6b304.jpg)

<table><tr><td>PIN#</td><td>Signal Name</td><td>PIN#</td><td>Signal Name</td></tr><tr><td>R1</td><td>LAN1_CT</td><td>U7</td><td>GND</td></tr><tr><td>R2</td><td>LAN1_MDI0_P</td><td>U8</td><td>USB31_3_TX_RE_CN_DN</td></tr><tr><td>R3</td><td>LAN1_MDI0_N</td><td>U9</td><td>USB31_3_TX_RE_CN_DP</td></tr><tr><td>R4</td><td>LAN1_MDI1_P</td><td>U10</td><td>USBVCC2</td></tr><tr><td>R5</td><td>LAN1_MDI1_N</td><td>U11</td><td>USB2_P4_CMC_DN</td></tr><tr><td>R6</td><td>LAN1_MDI2_P</td><td>U12</td><td>USB2_P4_CMC_DP</td></tr><tr><td>R7</td><td>LAN1_MDI2_N</td><td>U13</td><td>GND</td></tr><tr><td>R8</td><td>LAN1_MDI3_P</td><td>U14</td><td>USB31_4_RX_RE_CN_DN</td></tr><tr><td>R9</td><td>LAN1_MDI3_N</td><td>U15</td><td>USB31_4_RX_RE_CN_DP</td></tr><tr><td>R10</td><td>GND</td><td>U16</td><td>GND</td></tr><tr><td>L1</td><td>LIINK_AT_1</td><td>U17</td><td>USB31_4_TX_RE_CN_DN</td></tr><tr><td>L2</td><td>ACT_AT_1</td><td>U18</td><td>USB31_4_TX_RE_CN_DP</td></tr><tr><td>L3</td><td>LINK1000J_1</td><td>G1</td><td>GND</td></tr><tr><td>L4</td><td>LINK2500J_1</td><td>G2</td><td>GND</td></tr><tr><td>U1</td><td>USBVCC1</td><td>G3</td><td>GND</td></tr><tr><td>U2</td><td>USB2_P3_CMC_DN</td><td>G4</td><td>GND</td></tr><tr><td>U3</td><td>USB2_P3_CMC_DP</td><td>G5</td><td>GND</td></tr><tr><td>U4</td><td>GND</td><td>G6</td><td>GND</td></tr><tr><td>U5</td><td>USB31_3_RX_RE_CN_DN</td><td>G7</td><td>GND</td></tr><tr><td>U6</td><td>USB31_3_RX_RE_CN_DP</td><td>G8</td><td>GND</td></tr></table>

# 1G Base-T\_RJ45 + USB3.2 Gen2 x2

RJ45\_USB2

![Left LED\nC8\nC1\nRight LED\n12.63 ±0.25\nU18\nU14\nU13\n4.13 ±0.25\n19.59 ±0.25\nU9\nU5\nU1\nU4\n0.2~0.6\nAfter Pre-Soldering\n0.45 ±0.08\nUSB\n0.50 ±0.08 LED\n12.7~14.2\n15.80 ±0.50\n18.55 ±0.38](.axe-7420gwa-50m-22811-1000-02/1de58813f5c6771e41305a6d649ab16f41829c0e316f2e47c003ae0c35c9f0e0.jpg)

![L3\nOrange(橙)\nL4\nGreen(綠)](.axe-7420gwa-50m-22811-1000-02/c4d72c4ad93a751557dadd2b8fe3f31ec5c52ccea256e3b4ee20e3e03d0b1b0d.jpg)

![L1\nYellow(黄)\nL2](.axe-7420gwa-50m-22811-1000-02/0d1273065555cc7b8b40b5a9799e50707867b17fabab41c87bafccb0a9af14b5.jpg)

<table><tr><td>Emitting Color</td><td> $\lambda_{p}$  (nm)</td><td>Vf @lf=20mA</td><td>Ir @Vr=5V</td></tr><tr><td>Green</td><td>570</td><td>1.7 ~2.6 V</td><td>10μA max.</td></tr><tr><td>Orange</td><td>605</td><td>1.7 ~2.6 V</td><td>10μA max.</td></tr><tr><td>Yellow</td><td>588</td><td>1.7 ~2.6 V</td><td>10μA max.</td></tr></table>

<table><tr><td rowspan="21">&lt;img src="images/7d62074436401ba063fab67c6d3ef562b7e3f336075f7d690c38de03ca259ee5.jpg"/&gt;</td><td>PIN#</td><td>Signal Name</td><td>PIN#</td><td>Signal Name</td></tr><tr><td>R1</td><td>LAN2_CT</td><td>U7</td><td>GND</td></tr><tr><td>R2</td><td>LAN2_MDI0_P</td><td>U8</td><td>USB31_5_TX_RE_CN_DN</td></tr><tr><td>R3</td><td>LAN2_MDI0_N</td><td>U9</td><td>USB31_5_TX_RE_CN_DP</td></tr><tr><td>R4</td><td>LAN2_MDI1_P</td><td>U10</td><td>USBVCC4</td></tr><tr><td>R5</td><td>LAN2_MDI1_N</td><td>U11</td><td>USB2_P6_CMC_DN</td></tr><tr><td>R6</td><td>LAN2_MDI2_P</td><td>U12</td><td>USB2_P6_CMC_DP</td></tr><tr><td>R7</td><td>LAN2_MDI2_N</td><td>U13</td><td>GND</td></tr><tr><td>R8</td><td>LAN2_MDI3_P</td><td>U14</td><td>USB31_6_RX_RE_CN_DN</td></tr><tr><td>R9</td><td>LAN2_MDI3_N</td><td>U15</td><td>USB31_6_RX_RE_CN_DP</td></tr><tr><td>R10</td><td>GND</td><td>U16</td><td>GND</td></tr><tr><td>L1</td><td>LIINK_AT_2</td><td>U17</td><td>USB31_6_TX_RE_CN_DN</td></tr><tr><td>L2</td><td>ACT_AT_2</td><td>U18</td><td>USB31_6_TX_RE_CN_DP</td></tr><tr><td>L3</td><td>LINK1000J_2</td><td>G1</td><td>GND</td></tr><tr><td>L4</td><td>LINK2500J_2</td><td>G2</td><td>GND</td></tr><tr><td>U1</td><td>USBVCC3</td><td>G3</td><td>GND</td></tr><tr><td>U2</td><td>USB2_P5_CMC_DN</td><td>G4</td><td>GND</td></tr><tr><td>U3</td><td>USB2_P5_CMC_DP</td><td>G5</td><td>GND</td></tr><tr><td>U4</td><td>GND</td><td>G6</td><td>GND</td></tr><tr><td>U5</td><td>USB31_5_RX_RE_CN_DN</td><td>G7</td><td>GND</td></tr><tr><td>U6</td><td>USB31_5_RX_RE_CN_DP</td><td>G8</td><td>GND</td></tr></table>

# USB3.2 Gen2 Type-A

USB2

![Technical line drawing of a mechanical component with no visible text or symbols](.axe-7420gwa-50m-22811-1000-02/6596df7f9ae170b424a251cdc731f3ce81c05a7e29c358957ac6cc86e7f24b45.jpg)

![12.50±0.10\n11.10±0.10\n①\n②\n③\n④\n9 8 7 6 5\n1 2 3 4\n12.58\n7.23\n3.27\n9-2.34\n1.84±0.05\n5.12±0.10\n9-0.40±0.1\n2.00\n4.00\n7.00\n8.00\n9.18](.axe-7420gwa-50m-22811-1000-02/8f8b6ae9791c9ada49f2d1c7ca835c7beefa9128213c45ecf29469797587c055.jpg)

<table><tr><td rowspan="8">&lt;img src="images/65e36a8166f37517ac1ee2d232c837a2af29b896f51e517fb9d9e40c354cbb4d.jpg"/&gt;</td><td>PIN#</td><td>Signal Name</td><td>PIN#</td><td>Signal Name</td></tr><tr><td>1</td><td>HUB_VBUS_USB1</td><td>8</td><td>USB31_2_TX_RE_CN_DN</td></tr><tr><td>2</td><td>USB2_P2_CMC_DN</td><td>9</td><td>USB31_2_TX_RE_CN_DP</td></tr><tr><td>3</td><td>USB2_P2_CMC_DP</td><td>G1</td><td>GND</td></tr><tr><td>4</td><td>GND</td><td>G2</td><td>GND</td></tr><tr><td>5</td><td>USB31_2_RX_RE_CN_DN</td><td>G3</td><td>GND</td></tr><tr><td>6</td><td>USB31_2_RX_RE_CN_DP</td><td>G4</td><td>GND</td></tr><tr><td>7</td><td>GND</td><td></td><td></td></tr></table>

# USB3.2 Gen2 Type-C

USB1

![Technical line drawing of a mechanical housing or enclosure component (no text or symbols)](.axe-7420gwa-50m-22811-1000-02/9e4d272651939beb76b4e5341e1041419a5b5663a6fa790c58c7845fcbdab6a3.jpg)

![(8.34)\nA1\nY\n0.25(2X)\n(2.54)\nB12\nH\nB1](.axe-7420gwa-50m-22811-1000-02/4b4161788fcc869a91341b2f59547440fc54dfdaea5f54167c70f4384e5e0760.jpg)

<table><tr><td rowspan="16">USB1A2TX1_P RX1_P B11B10TX1_N RX1_NA11B3TX2_P RX2_P A11B10TX2_N RX2_NA10A6USB2_P_T VBUS_A4 A4B7USB2_P_T USB2_N_T VBUS_A9 A9B4B6USB2_P_B VBUS_B4 B9VBUS_B9A1A5CC1 GND_A1 A12B5CC2 GND_A12 B1GND_B1 B12SBU1 GND_B12A12G3CGND_G3 1 pin CGND_G1 G1G5CGND_G5 1 pin CGND_G2G6CGND_G4 1 pinCGND_G6 N1 N2N1N261_USB_24P_G6PT_2NP_Type-C_0_B</td><td>PIN#</td><td>Signal Name</td><td>PIN#</td><td>Signal Name</td></tr><tr><td>A1</td><td>GND</td><td>B4</td><td>P_5V_VBUS_C2</td></tr><tr><td>A2</td><td>USB31_1_TX1_CN_DP</td><td>B5</td><td>TYPE_C2_CC2</td></tr><tr><td>A3</td><td>USB31_1_TX1_CN_DN</td><td>B6</td><td>USB2_P1_CMC_DP</td></tr><tr><td>A4</td><td>P_5V_VBUS_C2</td><td>B7</td><td>USB2_P1_CMC_DN</td></tr><tr><td>A5</td><td>TYPE_C2_CC1</td><td>B8</td><td>NC</td></tr><tr><td>A6</td><td>USB2_P1_CMC_DP</td><td>B9</td><td>P_5V_VBUS_C2</td></tr><tr><td>A7</td><td>USB2_P1_CMC_DN</td><td>B10</td><td>USB31_1_RX1_CN_DN</td></tr><tr><td>A8</td><td>NC</td><td>B11</td><td>USB31_1_RX1_CN_DP</td></tr><tr><td>A9</td><td>P_5V_VBUS_C2</td><td>B12</td><td>GND</td></tr><tr><td>A10</td><td>USB31_1_RX2_CN_DN</td><td>G1</td><td>GND</td></tr><tr><td>A11</td><td>USB31_1_RX2_CN_DP</td><td>G2</td><td>GND</td></tr><tr><td>A12</td><td>GND</td><td>G3</td><td>GND</td></tr><tr><td>B1</td><td>GND</td><td>G4</td><td>GND</td></tr><tr><td>B2</td><td>USB31_1_TX2_CN_DP</td><td>G5</td><td>GND</td></tr><tr><td>B3</td><td>USB31_1_TX2_CN_DN</td><td>G6</td><td>GND</td></tr></table>

# Audio Jack $3 ^ { \star } 1$ Φ3.5

AUDIO1
![This image is a technical engineering drawing of a multi-port electronic connector, featuring three distinct sections: a 3D view, a dimensioned 2D view, and a circuit schematic.\n\n**Left Section:**\nAn isometric view of a rectangular component. It features three large circular ports stacked vertically on the front face and a row of pins extending from the bottom edge.\n\n**Center Section:**\nA 2D front view with dimensional callouts.\n*   **Labels:** 'PORT 3', 'PORT 2', and 'PORT 1' identify the three circular ports.\n*   **Dimensions:**\n    *   Top width: '12.66 (0.498)'\n    *   Hole sizes: '3-Ø3.60 (Ø0.142)' and '3-Ø7.00 (Ø0.276)'\n    *   Vertical spacing: '3.73 (.147)', '2.50±0.25 (.099±0.1)', '6.50 (0.256)', '3.00 (0.118)', '17.50 (0.689)', '28.50 (1.122)'\n    *   Bottom pin details: '13-0.70±0.10 (.028±0.004)', '2.00 (.079)', and spacing '13.9 (.547)'\n\n**Right Section:**\nA diagram labeled 'CIRCUIT SCHEMATIC' at the bottom. It displays three groups of electrical connections corresponding to the ports.\n*   **PORT 3:** Lists pins '32', '34', '33', '35', and '1'. An arrow points from the top group to the text 'INSULATOR'. Pins 33 and 35 have switch symbols.\n*   **PORT 2:** Lists pins '22', '24', '23', '25', and '1'. Pins 24 and 25 have switch symbols.\n*   **PORT 1:** Lists pins '2', '4', '3', '5', and '1'. Pins 4 and 5 have switch symbols.\n*   Resistor symbols are connected to the switch terminals on the right side for all three port groups.](.axe-7420gwa-50m-22811-1000-02/7b91c94f6539ab7eb37547e1c61842c9c89bd8beb8edd85b0758ce2ce7a2c231.jpg)
PORT3
CIRCUIT SCHEMATIC

![AUDIO1\nINSULATOR\nblue\nG1\n32\n34\n33\n35\nG2\n34\nG3\n33\nG4\nN1\n22\n24\n23\n25\n1\n2\n4\n3\n5\nline\npink\nAJ_P3_3.5mm](.axe-7420gwa-50m-22811-1000-02/e7b47af84ecbbc3496c8fd449b9b43b05ed69bf9f1ff14932d2895e727a6ce64.jpg)

![Line-In\nFront\nSpeaker\nOut\nMIC-In](.axe-7420gwa-50m-22811-1000-02/c328a0d559b780ce763f0c404479288bb2c6d682d143fa61ac119de0058e9867.jpg)

<table><tr><td>PIN#</td><td>Signal Name</td><td>PIN#</td><td>Signal Name</td></tr><tr><td>1</td><td>AGND_AU</td><td>32</td><td>CN_LINE1_L</td></tr><tr><td>2</td><td>CN_MIC1_L</td><td>33</td><td>LINE1_JD</td></tr><tr><td>3</td><td>MIC1_JD</td><td>34</td><td>AGND_AU</td></tr><tr><td>4</td><td>AGND_AU</td><td>35</td><td>CN_LINE1_R</td></tr><tr><td>5</td><td>CN_MIC1_R</td><td>G1</td><td>AU_CHGND</td></tr><tr><td>22</td><td>CN_FRONT_L</td><td>G2</td><td>AU_CHGND</td></tr><tr><td>23</td><td>FRONT_JD</td><td>G3</td><td>AU_CHGND</td></tr><tr><td>24</td><td>AGND_AU</td><td>G4</td><td>AU_CHGND</td></tr><tr><td>25</td><td>CN_FRONT_R</td><td></td><td></td></tr></table>

# 5.2 Onboard Headers and Connectors

# Chassis Intrusion Pin Header/Cable Definition

![The image is a diagram titled '**Front panel extension cable**'. It depicts a cable assembly connecting a large multi-pin connector on the left to five distinct 4-pin blocks on the right.\n\n**Labeled Blocks (Right Side):**\nFrom top to bottom, the text labels on the five terminal blocks are:\n1.  **PWR SW+**, **PWR SW-**, **RST SW+**, **RST SW-**\n2.  **PLED+**, **PLED-**, **HDD LED+**, **HDD LED-**\n3.  **LAN1 LED+**, **LAN1 LED-**, **LAN2 LED+**, **LAN2 LED-**\n4.  **SYSLF1+**, **SYSLF1-**, **SYSALARM+**, **SYSALARM-**\n5.  **UID SW+**, **UID SW-**, **UID LED+**, **UID LED-**\n\n**Connections:**\n*   A bundle of wires originates from the large connector block on the left.\n*   These wires run through the central cable (represented by a hatched rectangle).\n*   The cable splits into five separate groups of wires, each connecting the central cable to one of the four labeled blocks listed above.](.axe-7420gwa-50m-22811-1000-02/a84352d530ebeae1ef8f8e90dc3556bf8fb32d11b5a21118cdd228dd9dfd6415.jpg)

![20\n19\n2\n1](.axe-7420gwa-50m-22811-1000-02/cc6bc88f342e3751f240406b57e929a95add7abe8e018e663f7b1adb644abb6f.jpg)

<table><tr><td>Pin</td><td>Signal</td><td>Pin</td><td>Signal</td></tr><tr><td>1</td><td>PWR SW-</td><td>2</td><td>SYS_FLT-</td></tr><tr><td>3</td><td>PWR SW+</td><td>4</td><td>SYS_FLT+</td></tr><tr><td>5</td><td>PLED+</td><td>6</td><td>UID SW+</td></tr><tr><td>7</td><td>PLED-</td><td>8</td><td>UID SW-</td></tr><tr><td>9</td><td>LAN1_LED+</td><td>10</td><td>LAN2_LED-</td></tr><tr><td>11</td><td>LAN1_LED-</td><td>12</td><td>LAN2_LED+</td></tr><tr><td>13</td><td>HDD_LED_+</td><td>14</td><td>UID_LED-</td></tr><tr><td>15</td><td>HDD_LED_-</td><td>16</td><td>UID_LED+)</td></tr><tr><td>17</td><td>THRM_ALRM+</td><td>18</td><td>RST_SW+</td></tr><tr><td>19</td><td>THRM_ALRM-</td><td>20</td><td>RST_SW-</td></tr></table>

# Common Redundant Power Supply

CRPS1

<table><tr><td>Pin</td><td>Signal</td><td>Pin</td><td>Signal</td></tr><tr><td>P1</td><td>GND</td><td>P2</td><td>PSU2_ALARM-L</td></tr><tr><td>P3</td><td>PMBUS_CLK_O</td><td>P4</td><td>PSU2_PSON-L</td></tr><tr><td>P5</td><td>PMBUS_DAT_O</td><td>P6</td><td>P_+3V3_DUAL</td></tr><tr><td>P7</td><td>PWROK_PSU1_N</td><td>P8</td><td>NC</td></tr><tr><td>P9</td><td>PWROK_PSU2_N</td><td>P10</td><td>GND</td></tr><tr><td>P11</td><td>GND</td><td>P12</td><td>CRPS_PSU1_DET#</td></tr><tr><td>P13</td><td>NC</td><td>P14</td><td>CRPS_PSU2_DET#</td></tr><tr><td>P15</td><td>EXT_SMBUS_ALERT-L</td><td>P16</td><td>EXT_SMBUS_SDA</td></tr><tr><td>P17</td><td>PSU1_PSON-L</td><td>P18</td><td>EXT_SMBUS_SCL</td></tr><tr><td>P19</td><td>PSU1_ALARM-L</td><td>P20</td><td>GND</td></tr></table>

![Pin1\nPin1\nPin1\nPin1\nPin1\nPin1\nPin1\nPin1\nPin1\nPin1\nPin1\nPin1\nPin1\nPin1\nPin1\nPin1\nPin1\nPin1\nPin1\nPin1\nPin1\nPin1\nPin1\nPin1\nPin1\nPin1\nPin1\nPin1\nPin1\nPin1\nPin1\nPin1\nPin1\nPin1\n20\n2\n3\n4\n5\n6\n7\n8\n9\n10\n11\n12\n13\n14\n15\n16\n17\n18\n19\n20](.axe-7420gwa-50m-22811-1000-02/8745aa54eeaac9f85850814c750a44f6a7274639e21a43030a33be92e6bfaa49.jpg)

# DI and DO

CN21

<table><tr><td>Pin</td><td>Signal</td></tr><tr><td>P1</td><td>GND</td></tr><tr><td>P2</td><td>DO0_CN</td></tr><tr><td>P3</td><td>DO1_CN</td></tr><tr><td>P4</td><td>DO2_CN</td></tr><tr><td>P5</td><td>DO3_CN</td></tr><tr><td>P6</td><td>DI0_CN</td></tr><tr><td>P7</td><td>DI1_CN</td></tr><tr><td>P8</td><td>DI2_CN</td></tr><tr><td>P9</td><td>DI3_CN</td></tr><tr><td>P10</td><td>DIDO_PWR</td></tr></table>

![Pin1](.axe-7420gwa-50m-22811-1000-02/5b67a5951ce90b1544705a49dd4f270551cbb88a8942ea696b49d6a6ab90a3f1.jpg)

# SMBus

SMBus2

<table><tr><td>Pin</td><td>Signal</td></tr><tr><td>P1</td><td>PMBUS_CLK_O</td></tr><tr><td>P2</td><td>PMBUS_DAT_O</td></tr><tr><td>P3</td><td>SMBUS1_ALERT</td></tr><tr><td>P4</td><td>GND</td></tr><tr><td>P5</td><td>P_+3V3_DUAL</td></tr></table>

![GND\nPin1](.axe-7420gwa-50m-22811-1000-02/d362759c0fa8f7adcd52068f0b7e6f6f088cab9f83a1aa5a206e0f3cdbeec0f1.jpg)

# USB

USB 3 and USB 4
![P1\n11 10\n20 1\nP2\n11 10\n20 1\n*8mm Max\n(32.5)\n+450 ± 30\n(35)\n①\n②⑦③④](.axe-7420gwa-50m-22811-1000-02/018ff221bc2fdacd8223a9c0f54bb3e6eab2d32962fed447004d4cd3d99285ab.jpg)

<table><tr><td>Pin</td><td>Signal</td><td>Pin</td><td>Signal</td></tr><tr><td>P1</td><td>P_+5V_USB_VBUS_A3</td><td></td><td></td></tr><tr><td>P2</td><td>USB31_9_RX_CN_DN</td><td>P19</td><td>P_+5V_USB_VBUS_A4</td></tr><tr><td>P3</td><td>USB31_9_RX_CN_DP</td><td>P18</td><td>USB31_10_RX_CN_DN</td></tr><tr><td>P4</td><td>GND</td><td>P17</td><td>USB31_10_RX_CN_DP</td></tr><tr><td>P5</td><td>USB31_9_TX_CN_DN</td><td>P16</td><td>GND</td></tr><tr><td>P6</td><td>USB31_9_TX_CN_DP</td><td>P15</td><td>USB31_10_TX_CN_DN</td></tr><tr><td>P7</td><td>GND</td><td>P14</td><td>USB31_10_TX_CN_DP</td></tr><tr><td>P8</td><td>USB2_P9_CMC_DN</td><td>P13</td><td>GND</td></tr><tr><td>P9</td><td>USB2_P9_CMC_DP</td><td>P12</td><td>USB2_P10_CMC_DN</td></tr><tr><td>P10</td><td>USB_OC5-L</td><td>P11</td><td>USB2_P10_CMC_DP</td></tr></table>

![Pin1](.axe-7420gwa-50m-22811-1000-02/c1708b95e6ac92ff033773c8647092dd8e32f8f0a4b4fb375ab9d4a846dd7ed5.jpg)

# VROC

CN15

<table><tr><td>Pin</td><td>Signal</td></tr><tr><td>P1</td><td>GND</td></tr><tr><td>P2</td><td>P_+3V3_S1</td></tr><tr><td>P3</td><td>GND</td></tr><tr><td>P4</td><td>PCH_SATA_RAID_KEY</td></tr></table>

![Pin1](.axe-7420gwa-50m-22811-1000-02/86f49ebccfbfffa8759bc6402384358b668f4f5f5c116abd3a240b8af84aa521.jpg)

# COM

SER 1, SER 2, SER 3, SER 4

<table><tr><td>Pin</td><td>Signal</td><td>Pin</td><td>Signal</td></tr><tr><td>P1</td><td>COM5_RS232_DCD-L</td><td>P2</td><td>COM5_RS232_DSR-L</td></tr><tr><td>P3</td><td>COM5_RS232_RXD</td><td>P4</td><td>COM5_RS232_RTS-L</td></tr><tr><td>P5</td><td>COM5_RS232_TXD</td><td>P6</td><td>COM5_RS232_CTS-L</td></tr><tr><td>P7</td><td>COM5_RS232_DTR-L</td><td>P8</td><td>COM5_RS232_RI</td></tr><tr><td>P9</td><td>GND</td><td>P10</td><td>N.C</td></tr></table>

![Diagram of a control panel with labeled buttons and indicators, including a red square button and yellow circles.](.axe-7420gwa-50m-22811-1000-02/a92fbaf80749c8deee54e028d2b388886942b34e6efdfc0d9055f7bc598b7a00.jpg)

# SPGIO

CN7

<table><tr><td>Pin</td><td>Signal</td><td>Pin</td><td>Signal</td></tr><tr><td>P1</td><td>SATA_SDATAOUT1</td><td>P2</td><td>N.C</td></tr><tr><td>P3</td><td>SATA_SLOAD</td><td>P4</td><td>GND</td></tr><tr><td>P5</td><td>SATA_SCLOCK</td><td>P6</td><td>SATA_SCLOCK</td></tr><tr><td>P7</td><td>GND</td><td>P8</td><td>SATA_SLOAD</td></tr><tr><td>P9</td><td>N.C</td><td>P10</td><td>SATA_SDATAOUT0</td></tr></table>

![Pin1](.axe-7420gwa-50m-22811-1000-02/ad1ef7801148a8e0fd9d89c77e519d5d4da6509b738e6817859dd94a67388797.jpg)

# Misc

F\_MISC1

<table><tr><td>Pin</td><td>Signal</td><td>Pin</td><td>Signal</td></tr><tr><td>P1</td><td>GND</td><td>P2</td><td>CUSTOM_LED2-L</td></tr><tr><td>P3</td><td>PWRBTN-L</td><td>P4</td><td>CUSTOM_LED2_PWR(3V3)</td></tr><tr><td>P5</td><td>S0_LED_PWR(3V3)</td><td>P6</td><td>FP_ID_BTN_R_N</td></tr><tr><td>P7</td><td>S0_LED-L</td><td>P8</td><td>GND</td></tr><tr><td>P9</td><td>LAN1_LED_PWR(3V3)</td><td>P10</td><td>LAN2_LED_ACT-L</td></tr><tr><td>P11</td><td>LAN1_LED_ACT-L</td><td>P12</td><td>LAN2_LED_PWR(3V3)</td></tr><tr><td>P13</td><td>HDD_LED_PWR (5V)</td><td>P14</td><td>FP_ID_LED-U</td></tr><tr><td>P15</td><td>HDD_LED_N</td><td>P16</td><td>UID_LED_PWR(3V3)</td></tr><tr><td>P17</td><td>CUSTOM_LED1_PWR(3V3)</td><td>P18</td><td>RSTBTN_3V3-L</td></tr><tr><td>P19</td><td>CUSTOM_LED1-L</td><td>P20</td><td>GND</td></tr></table>

![Pin1](.axe-7420gwa-50m-22811-1000-02/15575bfdf3b2d51eb8ad71d748585321a0b8787d8fa5ab3b0fa54a2ca4e1843c.jpg)

# SATA

SATA\_CN1, SATA\_CN2, SATA\_CN3, SATA\_CN4

<table><tr><td>Pin</td><td>Signal</td><td>Pin</td><td>Signal</td></tr><tr><td>AS1</td><td>GND</td><td>BS1</td><td>GND</td></tr><tr><td>AS2</td><td>SATA_0_TX_DP</td><td>BS2</td><td>SATA_1_TX_DP</td></tr><tr><td>AS3</td><td>SATA_0_TX_DN</td><td>BS3</td><td>SATA_1_TX_DN</td></tr><tr><td>AS4</td><td>GND</td><td>BS4</td><td>GND</td></tr><tr><td>AS5</td><td>SATA_0_RX_DN</td><td>BS5</td><td>SATA_1_RX_DN</td></tr><tr><td>AS6</td><td>SATA_0_RX_DP</td><td>BS6</td><td>SATA_1_RX_DP</td></tr><tr><td>AS7</td><td>GND</td><td>BS7</td><td>GND</td></tr></table>

![Pin1](.axe-7420gwa-50m-22811-1000-02/b405f0aac087c08128561bbdb4bc94800070c6ff974982b0f1a28b91f95dd7f3.jpg)

# USB2 PH

CN6

<table><tr><td>Pin</td><td>Signal</td><td>Pin</td><td>Signal</td></tr><tr><td>P1</td><td>P5VA_U2RT3_4</td><td>P2</td><td>P5VA_U2RT3_4</td></tr><tr><td>P3</td><td>USB2_P12_CMC_DN</td><td>P4</td><td>USB2_P11_CMC_DN</td></tr><tr><td>P5</td><td>USB2_P12_CMC_DP</td><td>P6</td><td>USB2_P11_CMC_DP</td></tr><tr><td>P7</td><td>GND</td><td>P8</td><td>GND</td></tr><tr><td>P9</td><td>N.C</td><td>P10</td><td></td></tr></table>

![8\n9\nPin1](.axe-7420gwa-50m-22811-1000-02/06fb57a4da90bbd539267263c70f9035b368af9fe86e9f6c1eed360e8f5c67a4.jpg)

# eSPI PH

ESPDB1

<table><tr><td>Pin</td><td>Signal</td><td>Pin</td><td>Signal</td></tr><tr><td>P1</td><td>P_+DBPWR (1V8/3V3)</td><td>P2</td><td>GND</td></tr><tr><td>P3</td><td>ESPI_DB_DAT1</td><td>P4</td><td>ESPI_DB_DAT2</td></tr><tr><td>P5</td><td>ESPI_DB_CLK</td><td>P6</td><td>ESPI_DB_DAT0</td></tr><tr><td>P7</td><td>ESPI_DB_RST-L</td><td>P8</td><td>ESPI_DB_CS-L</td></tr><tr><td>P9</td><td>ESPI_DB_DAT3</td><td>P10</td><td>P_+DBPWR (1V8/3V3)</td></tr></table>

![Pin1](.axe-7420gwa-50m-22811-1000-02/23f714f8347257068267fa9bc994580901c1aa5b793301a6a0c687d228df85e0.jpg)

SlimSAS

<table><tr><td>Pin</td><td>Signal</td><td>Pin</td><td>Signal</td></tr><tr><td>A1</td><td>GND</td><td>B1</td><td>GND</td></tr><tr><td>A2</td><td>PCIE_21_RX_DP</td><td>B2</td><td>PCIE_21_TX_DP</td></tr><tr><td>A3</td><td>PCIE_21_RX_DN</td><td>B3</td><td>PCIE_21_TX_DN</td></tr><tr><td>A4</td><td>GND</td><td>B4</td><td>GND</td></tr><tr><td>A5</td><td>PCIE_22_RX_DP</td><td>B5</td><td>PCIE_22_TX_DP</td></tr><tr><td>A6</td><td>PCIE_22_RX_DN</td><td>B6</td><td>PCIE_22_TX_DN</td></tr><tr><td>A7</td><td>GND</td><td>B7</td><td>GND</td></tr><tr><td>A8</td><td>N.C</td><td>B8</td><td>N.C</td></tr><tr><td>A9</td><td>N.C</td><td>B9</td><td>N.C</td></tr><tr><td>A10</td><td>GND</td><td>B10</td><td>N.C</td></tr><tr><td>A11</td><td>CLK_SRC6_DP</td><td>B11</td><td>SAS_RST-L</td></tr><tr><td>A12</td><td>CLK_SRC6_DN</td><td>B12</td><td>N.C</td></tr><tr><td>A13</td><td>GND</td><td>B13</td><td>GND</td></tr><tr><td>A14</td><td>PCIE_23_RX_DP</td><td>B14</td><td>PCIE_23_TX_DP</td></tr><tr><td>A15</td><td>PCIE_23_RX_DN</td><td>B15</td><td>PCIE_23_TX_DN</td></tr><tr><td>A16</td><td>GND</td><td>B16</td><td>GND</td></tr><tr><td>A17</td><td>PCIE_24_RX_DP</td><td>B17</td><td>PCIE_24_TX_DP</td></tr><tr><td>A18</td><td>PCIE_24_RX_DN</td><td>B18</td><td>PCIE_24_TX_DN</td></tr><tr><td>A19</td><td>GND</td><td>B19</td><td>GND</td></tr></table>

![A1\nB1](.axe-7420gwa-50m-22811-1000-02/53fd3f85e316ea39808d3084d573cbd3eec90ff41c2fe9d28aebf72b241a7f17.jpg)

# ATX\_PCIe

CN11, CN12

<table><tr><td>Pin</td><td>Signal</td><td>Pin</td><td>Signal</td></tr><tr><td>P1</td><td>P_+12V_PSU</td><td>P5</td><td>GND</td></tr><tr><td>P2</td><td>P_+12V_PSU</td><td>P6</td><td>SENSEO</td></tr><tr><td>P3</td><td>P_+12V_PSU</td><td>P7</td><td>GND</td></tr><tr><td>P4</td><td>SENSE1</td><td>P8</td><td>GND</td></tr></table>

![B51A51\n8\n7\n6\n5\n4\n3\n2\n1\nN2\nN1](.axe-7420gwa-50m-22811-1000-02/048e29de19de76223bbe8ed75fed5937be16e6314ec0b1609fbbbbd06d91cb12.jpg)

# ATX\_CPU

CN9, CN10

<table><tr><td>Pin</td><td>Signal</td><td>Pin</td><td>Signal</td></tr><tr><td>P1</td><td>GND</td><td>P5</td><td>P_+12V_PSU</td></tr><tr><td>P2</td><td>GND</td><td>P6</td><td>P_+12V_PSU</td></tr><tr><td>P3</td><td>GND</td><td>P7</td><td>P_+12V_PSU</td></tr><tr><td>P4</td><td>GND</td><td>P8</td><td>P_+12V_PSU</td></tr></table>

![Circuit board layout diagram with labeled components and connection points](.axe-7420gwa-50m-22811-1000-02/2669e60f526ae8ea3bff893c70df2f9c48a69c92ae1f38b2eb470af8e9d01b55.jpg)

# ATX\_24P

PCN4

<table><tr><td>Pin</td><td>Signal</td><td>Pin</td><td>Signal</td></tr><tr><td>P1</td><td>P_+3V3_PSU</td><td>P13</td><td>P_+3V3_PSU</td></tr><tr><td>P2</td><td>P_+3V3_PSU</td><td>P14</td><td>-V12</td></tr><tr><td>P3</td><td>GND</td><td>P15</td><td>GND</td></tr><tr><td>P4</td><td>P_+5V_PSU</td><td>P16</td><td>PSON-L</td></tr><tr><td>P5</td><td>GND</td><td>P17</td><td>GND</td></tr><tr><td>P6</td><td>P_+5V_PSU</td><td>P18</td><td>GND</td></tr><tr><td>P7</td><td>GND</td><td>P19</td><td>GND</td></tr><tr><td>P8</td><td>PSU_PWROK</td><td>P20</td><td>-V5</td></tr><tr><td>P9</td><td>P_+5VSB_PSU</td><td>P21</td><td>P_+5V_PSU</td></tr><tr><td>P10</td><td>P_+12V_PSU</td><td>P22</td><td>P_+5V_PSU</td></tr><tr><td>P11</td><td>P_+12V_PSU</td><td>P23</td><td>P_+5V_PSU</td></tr><tr><td>P12</td><td>P_+3V3_PSU</td><td>P24</td><td>GND</td></tr></table>

![Technical diagram of a circuit board layout with numbered components and labeled terminals](.axe-7420gwa-50m-22811-1000-02/c2baf70fb4f69157d128215b40abad6daf04b1e7575e98b1cf85c964833f10ce.jpg)

# MCIO

MCIO\_CN1, MCIO\_CN2, MCIO\_CN3,MCIO\_CN4

<table><tr><td>Pin</td><td>Signal</td><td>Pin</td><td>Signal</td></tr><tr><td>A1</td><td>GND</td><td>B1</td><td>GND</td></tr><tr><td>A2</td><td>CPU_PCIE5_PE3_RX_0_DP</td><td>B2</td><td>CPU_PCIE5_PE3_TX_0_C_DP</td></tr><tr><td>A3</td><td>CPU_PCIE5_PE3_RX_0_DN</td><td>B3</td><td>CPU_PCIE5_PE3_TX_0_C_DN</td></tr><tr><td>A4</td><td>GND</td><td>B4</td><td>GND</td></tr><tr><td>A5</td><td>CPU_PCIE5_PE3_RX_1_DP</td><td>B5</td><td>CPU_PCIE5_PE3_TX_1_C_DP</td></tr><tr><td>A6</td><td>CPU_PCIE5_PE3_RX_1_DN</td><td>B6</td><td>CPU_PCIE5_PE3_TX_1_C_DN</td></tr><tr><td>A7</td><td>GND</td><td>B7</td><td>GND</td></tr><tr><td>A8</td><td>MCIO_1A_PWRBRK_CLKREQ_N</td><td>B8</td><td>SMB_MCIO1A_SCL</td></tr><tr><td>A9</td><td>MCIO_1A_SMB_ALERT_WAKE_N</td><td>B9</td><td>SMB_MCIO1A_SDA</td></tr><tr><td>A10</td><td>GND</td><td>B10</td><td>GND</td></tr><tr><td>A11</td><td>CLK_100M_DB2000_MCIO_1A_DP</td><td>B11</td><td>MCIO1_RST0_N</td></tr><tr><td>A12</td><td>CLK_100M_DB2000_MCIO_1A_DN</td><td>B12</td><td>MCIO1_PRSNT0_N</td></tr><tr><td>A13</td><td>GND</td><td>B13</td><td>GND</td></tr><tr><td>A14</td><td>CPU_PCIE5_PE3_RX_2_DP</td><td>B14</td><td>CPU_PCIE5_PE3_TX_2_C_DP</td></tr><tr><td>A15</td><td>CPU_PCIE5_PE3_RX_2_DN</td><td>B15</td><td>CPU_PCIE5_PE3_TX_2_C_DN</td></tr><tr><td>A16</td><td>GND</td><td>B16</td><td>GND</td></tr><tr><td>A17</td><td>CPU_PCIE5_PE3_RX_3_DP</td><td>B17</td><td>CPU_PCIE5_PE3_TX_3_C_DP</td></tr><tr><td>A18</td><td>CPU_PCIE5_PE3_RX_3_DN</td><td>B18</td><td>CPU_PCIE5_PE3_TX_3_C_DN</td></tr><tr><td>A19</td><td>GND</td><td>B19</td><td>GND</td></tr><tr><td>A20</td><td>CPU_PCIE5_PE3_RX_4_DP</td><td>B20</td><td>CPU_PCIE5_PE3_TX_4_C_DP</td></tr><tr><td>A21</td><td>CPU_PCIE5_PE3_RX_4_DN</td><td>B21</td><td>CPU_PCIE5_PE3_TX_4_C_DN</td></tr><tr><td>A22</td><td>GND</td><td>B22</td><td>GND</td></tr><tr><td>A23</td><td>CPU_PCIE5_PE3_RX_5_DP</td><td>B23</td><td>CPU_PCIE5_PE3_TX_5_C_DP</td></tr><tr><td>A24</td><td>CPU_PCIE5_PE3_RX_5_DN</td><td>B24</td><td>CPU_PCIE5_PE3_TX_5_C_DN</td></tr><tr><td>A25</td><td>GND</td><td>B25</td><td>GND</td></tr><tr><td>A26</td><td>MCIO_1A_PWRBRK_CLKREQ_N</td><td>B26</td><td>SMB_MCIO1B_SCL</td></tr><tr><td>A27</td><td>MCIO_1A_SMB_ALERT_WAKE_N</td><td>B27</td><td>SMB_MCIO1B_SDA</td></tr><tr><td>A28</td><td>GND</td><td>B28</td><td>GND</td></tr><tr><td>A29</td><td>CLK_100M_DB2000_MCIO_1B_DP</td><td>B29</td><td>MCIO1_RST0_N</td></tr><tr><td>A30</td><td>CLK_100M_DB2000_MCIO_1B_DN</td><td>B30</td><td>MCIO1_PRSNT0_N</td></tr><tr><td>A31</td><td>GND</td><td>B31</td><td>GND</td></tr><tr><td>A32</td><td>CPU_PCIE5_PE3_RX_6_DP</td><td>B32</td><td>CPU_PCIE5_PE3_TX_6_C_DP</td></tr><tr><td>A33</td><td>CPU_PCIE5_PE3_RX_6_DN</td><td>B33</td><td>CPU_PCIE5_PE3_TX_6_C_DN</td></tr><tr><td>A34</td><td>GND</td><td>B34</td><td>GND</td></tr><tr><td>A35</td><td>CPU_PCIE5_PE3_RX_7_DP</td><td>B35</td><td>CPU_PCIE5_PE3_TX_7_C_DP</td></tr><tr><td>A36</td><td>CPU_PCIE5_PE3_RX_7_DN</td><td>B36</td><td>CPU_PCIE5_PE3_TX_7_C_DN</td></tr><tr><td>A37</td><td>GND</td><td>B37</td><td>GND</td></tr></table>

![H-3\n1.5 mm\nH-2\n4 mm FOR RA CABLE APPLICATION ON WAITING HEIGHT\nH-1\nFOR RA CABLE APPLICATION ON WAITING HEIGHT\nA37\n1.5 mm\nABOVE L2.\nABOVE L1.](.axe-7420gwa-50m-22811-1000-02/09a83af73baa312fdf30c669c7ba816150d792a0d6fad4972c0c7150587a135c.jpg)

# Door Open Connector

CN19, CN20

<table><tr><td>Pin</td><td>Signal</td></tr><tr><td>P1</td><td>FRONT_CHASSIS</td></tr><tr><td>P2</td><td>GND</td></tr></table>

![Pin1](.axe-7420gwa-50m-22811-1000-02/4207cec92c708360b19393f0ace91803bed8dbb5b6aec252ce09210d91baaae8.jpg)

# IPMB

IPMB1

<table><tr><td>Pin</td><td>Signal</td></tr><tr><td>P1</td><td>IPMB_SDA</td></tr><tr><td>P2</td><td>IPMB_SCL</td></tr><tr><td>P3</td><td>NC</td></tr><tr><td>P4</td><td>GND</td></tr><tr><td>P5</td><td>P_+3V3_DUAL</td></tr></table>

![GND\nPin1\nGND](.axe-7420gwa-50m-22811-1000-02/09f5059718f57e5cb7879064efd00180c27e99ac1e1309e166432fbbde465a7c.jpg)

# CPLD\_JTAG

CN28

<table><tr><td>Pin</td><td>Signal</td><td>Pin</td><td>Signal</td></tr><tr><td>P1</td><td>GND</td><td>P2</td><td>P_+3V3SB</td></tr><tr><td>P3</td><td>GND</td><td>P4</td><td>FPGA_TMS</td></tr><tr><td>P5</td><td>GND</td><td>P6</td><td>FPGA_TCK</td></tr><tr><td>P7</td><td>GND</td><td>P8</td><td>FPGA_TDO</td></tr><tr><td>P9</td><td>GND</td><td>P10</td><td>FPGA_TDI</td></tr></table>

![2\n1\n1\n2\n4\n6\n3\n10\n1\n3\n5\n7\n9\n9\nG2\nA\n1](.axe-7420gwa-50m-22811-1000-02/d92403d9459a2fe70cb9318e8e73f07f9ab3a9c0b1b1ba12b4f39a51445dde8a.jpg)

# Backplane PCIe Header

CN24

<table><tr><td>Pin</td><td>Signal</td></tr><tr><td>P1</td><td>P_3V3_DUAL</td></tr><tr><td>P2</td><td>PCIE_HP_SCL</td></tr><tr><td>P3</td><td>PCIE_HP_SDA</td></tr><tr><td>P4</td><td>PCIE_HP_ALERT-L</td></tr><tr><td>P5</td><td>GND</td></tr></table>

![Pin1\nGND\nGND](.axe-7420gwa-50m-22811-1000-02/2406aa241af12601cf7a6fd3f66ae5b9d638daa14a897e66f45fa4f048172ed1.jpg)

# MIPI60

![2\n60\nN1\n61\n52\n63\n54\n1\n59\nN2\n60\n1](.axe-7420gwa-50m-22811-1000-02/6e3be436e7d12e681765491b22759c6ffd29a75491617f262c9422beb4e1a932.jpg)

# Debug UART

CN27

<table><tr><td>Pin</td><td>Signal</td><td>Pin</td><td>Signal</td></tr><tr><td>P1</td><td>P_+1V8_TPM</td><td>P2</td><td>GND</td></tr><tr><td>P3</td><td>CN_UART_RTS</td><td>P4</td><td>CN_UART_TXD</td></tr><tr><td>P5</td><td>CN_UART_CTS</td><td>P6</td><td>CN_UART_RXD</td></tr></table>

![Flowchart](.axe-7420gwa-50m-22811-1000-02/33ff6cac9660c48a62018733398b618df3b4e159b62205df13c9b1b7ef22eee4.jpg)

# FAN Connector

FAN\_\*

<table><tr><td>Pin</td><td>Signal</td></tr><tr><td>P1</td><td>GND</td></tr><tr><td>P2</td><td>P_12V_FAN_*</td></tr><tr><td>P3</td><td>*_FAN_TACH</td></tr><tr><td>P4</td><td>*U_PWMOUT</td></tr></table>

![Pure electrical circuit lines without any symbols](.axe-7420gwa-50m-22811-1000-02/ec1bb103be512ef8c898ead98ea9ab09737fdefc2946030e1af982057f827753.jpg)

# TPM Connector

TPM\_CN1

<table><tr><td>Pin</td><td>Signal</td><td>Remark</td><td>Pin</td><td>Signal</td></tr><tr><td>P1</td><td>GND</td><td></td><td>P2</td><td>SPI_CPU0_TPM_CS-L</td></tr><tr><td>P3</td><td>TPM_IRQ-L</td><td></td><td>P4</td><td>SPI_CPU0_TPM_MISO</td></tr><tr><td>P5</td><td>TPM_PRESNT-L</td><td></td><td>P6</td><td>SPI_CPU0_TPM_MOSI</td></tr><tr><td>P7</td><td>LPC_RST-L</td><td></td><td>P8</td><td>SPI_CPU0_TPM_CLK</td></tr><tr><td>P9</td><td>P_+1V8_TPM</td><td>PWR</td><td>P10</td><td>GND</td></tr></table>

![GND\nTM_WT_C1K\nTM_WT_M2K\nTM_WT_M3K\nTM_WT_PCA\nPin1\nGND](.axe-7420gwa-50m-22811-1000-02/302dd0c1fa5517de516553ed7a39e09fd7833dec922d997cc6838980042287c8.jpg)

# 5.3 Jumper and Switch Settings

# Jumper and Switch Locations

![CN26\nCN8\nCN1\nSW3\nCN22\nCN17\nCN18\nCN16\nCN25\nCN23](.axe-7420gwa-50m-22811-1000-02/afeb7a5304d229e16e20b81137ea83195c2077860e30b0d55aa6affcc5251e45.jpg)

Figure 6: Jumper and switch locations

# Clear CMOS Header

<table><tr><td>CN1</td><td>Settings</td></tr><tr><td>1-2</td><td>N/A (Default)</td></tr><tr><td>2-3</td><td>Clear CMOS</td></tr></table>

<table><tr><td rowspan="4">&lt;img src="images/f69ca36dc6a21e736a4eb09fe2b1672460dbbbca5bd33e117f7f8c3824097f6d.jpg"/&gt;</td><td>PIN#</td><td>Signal Name</td></tr><tr><td>1</td><td>NC</td></tr><tr><td>2</td><td>PCH_RTCRST-L</td></tr><tr><td>3</td><td>CLR_CMOS (1K ohm to GND)</td></tr></table>

# ME Reset Header

<table><tr><td>CN8</td><td>Settings</td></tr><tr><td>1-2</td><td>N/A (Default)</td></tr><tr><td>2-3</td><td>Reset ME (Please do not use except special situation)</td></tr></table>

<table><tr><td rowspan="4"></td><td>PIN#</td><td>Signal Name</td></tr><tr><td>1</td><td>NC</td></tr><tr><td>2</td><td>PCH_SRTCRST-L</td></tr><tr><td>3</td><td>1K ohm to GND</td></tr></table>

# COM3 Power Supply Selection Header

<table><tr><td>CN16</td><td>Settings</td></tr><tr><td>NC</td><td>No Power Supply (Default)</td></tr><tr><td>1-2</td><td>5V Power Supply</td></tr><tr><td>2-3</td><td>12V Power Supply</td></tr></table>

<table><tr><td rowspan="4">&lt;img src="images/e8b8b494c8bbba11aefd77eaff2abf2daa6ea129834f8b504e5edeba65cdd23f.jpg"/&gt;</td><td>PIN#</td><td>Signal Name</td></tr><tr><td>1</td><td>P_+5V_PSU</td></tr><tr><td>2</td><td>COM3 Power Supply</td></tr><tr><td>3</td><td>P_+12V_PSU</td></tr></table>

# COM4 Power Supply Selection Header

<table><tr><td>CN17</td><td>Settings</td></tr><tr><td>NC</td><td>No Power Supply (Default)</td></tr><tr><td>1-2</td><td>5V Power Supply</td></tr><tr><td>2-3</td><td>12V Power Supply</td></tr></table>

<table><tr><td rowspan="4">&lt;img src="images/2d30fc252614f6d488a17041d8940de0668238d5662fb6459105206f5c92c79a.jpg"/&gt;</td><td>PIN#</td><td>Signal Name</td></tr><tr><td>1</td><td>P_+5V_PSU</td></tr><tr><td>2</td><td>COM4 Power Supply</td></tr><tr><td>3</td><td>P_+12V_PSU</td></tr></table>

# Flash Descriptor Security Override (FDSO)

CN18

<table><tr><td>CN18</td><td>Settings</td></tr><tr><td>1-2</td><td>Enable FDSO</td></tr><tr><td>2-3</td><td>Disable FDSO (ME Lock) (Default)</td></tr></table>

![Based on the visual evidence, here is an accurate and concise description of the flowchart:\n\n**Labeled Blocks and Shapes:**\n\n*   **Left Column:** There are three blue rectangular blocks arranged vertically on the left side (two near the top, one below the main central block). Each blue block contains two purple squares side-by-side. Inside each purple square is a white vertical bar resembling the number '1'.\n*   **Central Structure:** A large yellow rectangular frame dominates the center. Inside this frame:\n    *   **Left Section:** A nested shape consisting of a yellow square border, a green square border inside it, and a central yellow circle containing a '1'.\n    *   **Right Section:** Two yellow circles side-by-side, each containing a '1'.\n*   **Right Column:** On the far right, there is a blue rectangular block containing two purple squares stacked vertically.\n*   **Bottom Row:** Below the central area, there is a row of three items:\n    *   A purple rectangle.\n    *   A blue square outline.\n    *   A purple rectangle labeled with the text 'GRID'.\n\n**Connections:**\n\n*   **Arrow:** A yellow arrow points from the left side (positioned between the top-left blocks) towards the large yellow central frame, indicating flow into the system. There are no other explicit connecting lines between the blocks.](.axe-7420gwa-50m-22811-1000-02/cb74742f2f94fe396385640ec329c1b973d2e39df1cc235260091a48d0fc9f95.jpg)

<table><tr><td>PIN#</td><td>Signal Name</td></tr><tr><td>1</td><td>+VCCPGPPDR_3P3_1P8</td></tr><tr><td>2</td><td>FLASH_DES_STRAP</td></tr><tr><td>3</td><td>20K ohm to GND</td></tr></table>

# COM5 Power Supply Selection Header

<table><tr><td>CN22</td><td>Settings</td></tr><tr><td>NC</td><td>No Power Supply (Default)</td></tr><tr><td>1-2</td><td>5V Power Supply</td></tr><tr><td>2-3</td><td>12V Power Supply</td></tr></table>

<table><tr><td rowspan="4">&lt;img src="images/f942b500e09f506815bfcdd3e1d7f0556eea4db9d4eb3f63acb39986c0a08c9e.jpg"/&gt;</td><td>PIN#</td><td>Signal Name</td></tr><tr><td>1</td><td>P_+5V_PSU</td></tr><tr><td>2</td><td>COM5 Power Supply</td></tr><tr><td>3</td><td>P_+12V_PSU</td></tr></table>

# Force Enable S0 Power

CN23 (Debug only, do not use)

<table><tr><td>CN23</td><td>Settings</td></tr><tr><td>1-2</td><td>N/A (Default)</td></tr><tr><td>2-3</td><td>Force Enable S0 Power (Debug only, do not use)</td></tr></table>

![Based on the provided image, here is the description of the flowchart/block diagram:\n\n**Labeled Blocks:**\n*   **Top Left:** A vertical stack of three purple rectangles. The top rectangle is labeled **'TOP'**. The middle and bottom rectangles are unlabeled.\n*   **Top Right:** A single purple rectangle labeled **'REMAIN'**.\n*   **Center Top:** A large yellow rectangle containing three internal elements:\n    *   A circle labeled **'00'**.\n    *   An unlabeled circle.\n    *   An unlabeled square inside a square.\n*   **Bottom Row:** Four purple squares arranged horizontally on a blue line. The first three squares are labeled **'01'**. The fourth square (far right) is unlabeled.\n\n**Connections:**\n*   **Downward Arrows:** Two blue, downward-pointing arrows originate from the bottom edge of the central yellow rectangle. One points from the center towards the first **'01'** block, and the other points from the right side towards the third **'01'** block.\n*   **Bus/Line Structure:** A blue wire-like structure connects the components.\n    *   A vertical blue line connects the left stack (starting from the **'TOP'** block).\n    *   A horizontal blue line connects the bottom row of squares.\n    *   A vertical blue line connects the **'REMAIN'** block to the bottom right area (above the unlabeled square).\n*   **Side Arrow:** A yellow triangle pointing to the right is positioned between the central yellow rectangle and the **'REMAIN'** block.](.axe-7420gwa-50m-22811-1000-02/15871e697bafdbb2e3cad24a48db332717531b2e0a69b10a1c0370e13f3e82ec.jpg)

<table><tr><td>PIN#</td><td>Signal Name</td></tr><tr><td>1</td><td>NC</td></tr><tr><td>2</td><td>PSON-L</td></tr><tr><td>3</td><td>GND</td></tr></table>

# COM2 Power Supply Selection Header

<table><tr><td>CN25</td><td>Settings</td></tr><tr><td>NC</td><td>No Power Supply (Default)</td></tr><tr><td>1-2</td><td>5V Power Supply</td></tr><tr><td>2-3</td><td>12V Power Supply</td></tr></table>

![Pure electrical circuit lines without any symbols](.axe-7420gwa-50m-22811-1000-02/552fd9bd2a08d2e8de5b2b4917cfba13282c4204b3f16bf9eb574c2b170322e5.jpg)

<table><tr><td>PIN#</td><td>Signal Name</td></tr><tr><td>1</td><td>P_+5V_PSU</td></tr><tr><td>2</td><td>COM2 Power Supply</td></tr><tr><td>3</td><td>P_+12V_PSU</td></tr></table>

# COM1 Power Supply Selection Header

<table><tr><td>CN26</td><td>Setting</td></tr><tr><td>NC</td><td>No Power Supply (Default)</td></tr><tr><td>1-2</td><td>5V Power Supply</td></tr><tr><td>2-3</td><td>12V Power Supply</td></tr></table>

![Diagram of a traffic light system with labeled components and colored indicators](.axe-7420gwa-50m-22811-1000-02/96c6dc22cade6314f49f66e4de7963a7427493655fb756d8025b2bcbf6fb8972.jpg)

<table><tr><td>PIN#</td><td>Signal Name</td></tr><tr><td>1</td><td>P_+5V_PSU</td></tr><tr><td>2</td><td>COM1 Power Supply</td></tr><tr><td>3</td><td>P_+12V_PSU</td></tr></table>

RS-485 Fail-Safe (Switch)

<table><tr><td>SW3</td><td>Setting OFF</td><td>Setting ON (Default)</td></tr><tr><td>1-8</td><td rowspan="2">COM1 RS-485 Fail-Safe Disable</td><td rowspan="2">COM1 RS-485 Fail-Safe Enable</td></tr><tr><td>2-7</td></tr><tr><td>3-6</td><td rowspan="2">COM2 RS-485 Fail-Safe Disable</td><td rowspan="2">COM2 RS-485 Fail-Safe Enable</td></tr><tr><td>4-5</td></tr></table>

![M1908F14\nM1908F24\nM1908F35\nM1908F47](.axe-7420gwa-50m-22811-1000-02/79fc7f7e38b377e49f3cd55b8359d1ab2252f0e89475e150578f9cce05c92263.jpg)

<table><tr><td>PIN#</td><td>Signal Name</td><td>PIN#</td><td>Signal Name</td></tr><tr><td>1</td><td>COM1_RXD_B</td><td>5</td><td>1K ohm to GND</td></tr><tr><td>2</td><td>COM1_DCD-L_B</td><td>6</td><td>1K ohm to P_+5V_PSU</td></tr><tr><td>3</td><td>COM2_RXD_B</td><td>7</td><td>1K ohm to GND</td></tr><tr><td>4</td><td>COM2_DCD-L_B</td><td>8</td><td>1K ohm to P_+5V_PSU</td></tr></table>

# 5.4 Expansion Slots

# Expansion Slot Block Diagram

Project Name: AXE-7400 PC BoardName:37233 Rev.A1

![The diagram depicts a block labeled 'Cle extension board_1' containing several internal components and external connections.\n\n**Internal Blocks:**\n*   **Top Row:** Four dashed rectangular blocks arranged horizontally:\n    *   'PCle_CN1' (subtext: 'PCle Gen5 X8')\n    *   'PCle_CN2' (subtext: 'PCle Gen5X8')\n    *   'PCle_CN3' (subtext: 'PCle Gen5X4')\n    *   'PCle_CN4' (subtext: 'PCle Gen5 X4')\n*   **Middle Row:** Three solid rectangular blocks: 'MCIO_1', 'MCIO_2', and 'MCIO_3'.\n*   **Bottom Left:** A block containing 'FAN_CN1' and 'FAN_CN2'. To its right is a block labeled 'U15 NCT7363Y FAN CTRL IC' with an arrow pointing towards the fan connector block.\n*   **Bottom Center:** Two blocks labeled 'PCle PWR_1' and 'PCle PWR_2'.\n*   **Bottom Right:** A single block labeled 'SMBUS1'.\n\n**Connections:**\n*   **Fan Outputs:** Two arrows point left from 'FAN_CN1' and 'FAN_CN2' towards the text 'SYSTEM_FAN' (which appears twice on the left side).\n*   **Power Input:** An arrow originates from the text 'P_+V12_PSU' at the bottom and splits to point upwards into both 'PCle PWR_1' and 'PCle PWR_2'.\n*   **MB Connection:** Four lines connect 'SMBUS1' to an external block labeled 'MB' on the right:\n    *   'P_+3V3_BMC' (arrow points right towards MB)\n    *   'PMBus_ALERT#_R_PSU' (arrow points right towards MB)\n    *   'BMC_SMBUS_DAT' (arrow points left towards SMBUS1)\n    *   'BMC_SMBUS_CLK' (arrow points left towards SMBUS1)](.axe-7420gwa-50m-22811-1000-02/32a8cb8617e7bd9e02bca6806334970ec0ac9c9b492cae6b4163f61544a9ec5c.jpg)

Figure 7: Expansion slot block diagram

# MCIO Connectors

Location: MCIO\_CN1; MCIO\_CN2; MCIO\_CN3

Description: MCIO x8, FML 74P RT

![Technical line drawing of a mechanical component with internal channels and mounting brackets (no text or symbols)](.axe-7420gwa-50m-22811-1000-02/db33addc273d29147eaf4e22433ab3954fc5d8b674bca4b3dc00ef4735c23cc9.jpg)

![22.48\n21.60\n1.00±0.20\nB1\nA1\n0.22\n0.15\n0.60\n24.445\n(2X)25.50\n3.05±0.88\nCENTER HEIGHT\nA37\n0.10\nALL SMT TAIL](.axe-7420gwa-50m-22811-1000-02/c40cd5f9b9e387b73da2c47e60e3a07f93c6922a141e0eb7ec31cd8da97aecbb.jpg)

MCIO\_CN1

<table><tr><td>Signal</td><td>Pin</td><td>Pin</td><td>Signal</td></tr><tr><td>GND</td><td>A1</td><td>B1</td><td>GND</td></tr><tr><td>MCIO_PCIE5_PE1_RX_0_DP</td><td>A2</td><td>B2</td><td>MCIO_PCIE5_PE1_TX_0_DP</td></tr><tr><td>MCIO_PCIE5_PE1_RX_0_DN</td><td>A3</td><td>B3</td><td>MCIO_PCIE5_PE1_TX_0_DN</td></tr><tr><td>GND</td><td>A4</td><td>B4</td><td>GND</td></tr><tr><td>MCIO_PCIE5_PE1_RX_1_DP</td><td>A5</td><td>B5</td><td>MCIO_PCIE5_PE1_TX_1_DP</td></tr><tr><td>MCIO_PCIE5_PE1_RX_1_DN</td><td>A6</td><td>B6</td><td>MCIO_PCIE5_PE1_TX_1_DN</td></tr><tr><td>GND</td><td>A7</td><td>B7</td><td>GND</td></tr><tr><td>MCIO_1A_PWRBRK_CLKREQ_N</td><td>A8</td><td>B8</td><td>SMB_MCIO1A_SCL</td></tr><tr><td>MCIO_1A_SMB_ALERT_WAKE_N</td><td>A9</td><td>B9</td><td>SMB_MCIO1A_SDA</td></tr><tr><td>GND</td><td>A10</td><td>B10</td><td>GND</td></tr><tr><td>CLK0_100M_MCIO_1_DP</td><td>A11</td><td>B11</td><td>MCIO_1A_RST_N</td></tr><tr><td>CLK0_100M_MCIO_1_DN</td><td>A12</td><td>B12</td><td>MCIO_1A_PRSNT_N</td></tr><tr><td>GND</td><td>A13</td><td>B13</td><td>GND</td></tr><tr><td>MCIO_PCIE5_PE1_RX_2_DP</td><td>A14</td><td>B14</td><td>MCIO_PCIE5_PE1_TX_2_DP</td></tr><tr><td>MCIO_PCIE5_PE1_RX_2_DN</td><td>A15</td><td>B15</td><td>MCIO_PCIE5_PE1_TX_2_DN</td></tr><tr><td>GND</td><td>A16</td><td>B16</td><td>GND</td></tr><tr><td>MCIO_PCIE5_PE1_RX_3_DP</td><td>A17</td><td>B17</td><td>MCIO_PCIE5_PE1_TX_3_DP</td></tr><tr><td>MCIO_PCIE5_PE1_RX_3_DN</td><td>A18</td><td>B18</td><td>MCIO_PCIE5_PE1_TX_3_DN</td></tr><tr><td>GND</td><td>A19</td><td>B19</td><td>GND</td></tr><tr><td>MCIO_PCIE5_PE1_RX_4_DP</td><td>A20</td><td>B20</td><td>MCIO_PCIE5_PE1_TX_4_DP</td></tr><tr><td>MCIO_PCIE5_PE1_RX_4_DN</td><td>A21</td><td>B21</td><td>MCIO_PCIE5_PE1_TX_4_DN</td></tr><tr><td>GND</td><td>A22</td><td>B22</td><td>GND</td></tr><tr><td>MCIO_PCIE5_PE1_RX_5_DP</td><td>A23</td><td>B23</td><td>MCIO_PCIE5_PE1_TX_5_DP</td></tr><tr><td>MCIO_PCIE5_PE1_RX_5_DN</td><td>A24</td><td>B24</td><td>MCIO_PCIE5_PE1_TX_5_DN</td></tr><tr><td>GND</td><td>A25</td><td>B25</td><td>GND</td></tr><tr><td>NC</td><td>A26</td><td>B26</td><td>NC</td></tr><tr><td>NC</td><td>A27</td><td>B27</td><td>NC</td></tr><tr><td>GND</td><td>A28</td><td>B28</td><td>GND</td></tr><tr><td>NC</td><td>A29</td><td>B29</td><td>NC</td></tr><tr><td>NC</td><td>A30</td><td>B30</td><td>NC</td></tr><tr><td>GND</td><td>A31</td><td>B31</td><td>GND</td></tr><tr><td>MCIO_PCIE5_PE1_RX_6_DP</td><td>A32</td><td>B32</td><td>MCIO_PCIE5_PE1_TX_6_DP</td></tr><tr><td>MCIO_PCIE5_PE1_RX_6_DN</td><td>A33</td><td>B33</td><td>MCIO_PCIE5_PE1_TX_6_DN</td></tr><tr><td>GND</td><td>A34</td><td>B34</td><td>GND</td></tr><tr><td>MCIO_PCIE5_PE1_RX_7_DP</td><td>A35</td><td>B35</td><td>MCIO_PCIE5_PE1_TX_7_DP</td></tr><tr><td>MCIO_PCIE5_PE1_RX_7_DN</td><td>A36</td><td>B36</td><td>MCIO_PCIE5_PE1_TX_7_DN</td></tr><tr><td>GND</td><td>A37</td><td>B37</td><td>GND</td></tr><tr><td>GND</td><td>G1</td><td>N1</td><td>NC</td></tr><tr><td>GND</td><td>G2</td><td>N2</td><td>NC</td></tr><tr><td>GND</td><td>G3</td><td></td><td></td></tr><tr><td>GND</td><td>G4</td><td></td><td></td></tr></table>

MCIO\_CN2

<table><tr><td>Signal</td><td>Pin</td><td>Pin</td><td>Signal</td></tr><tr><td>GND</td><td>A1</td><td>B1</td><td>GND</td></tr><tr><td>MCIO_PCIE5_PE2_RX_0_DP</td><td>A2</td><td>B2</td><td>MCIO_PCIE5_PE2_TX_0_DP</td></tr><tr><td>MCIO_PCIE5_PE2_RX_0_DN</td><td>A3</td><td>B3</td><td>MCIO_PCIE5_PE2_TX_0_DN</td></tr><tr><td>GND</td><td>A4</td><td>B4</td><td>GND</td></tr><tr><td>MCIO_PCIE5_PE2_RX_1_DP</td><td>A5</td><td>B5</td><td>MCIO_PCIE5_PE2_TX_1_DP</td></tr><tr><td>MCIO_PCIE5_PE2_RX_1_DN</td><td>A6</td><td>B6</td><td>MCIO_PCIE5_PE2_TX_1_DN</td></tr><tr><td>GND</td><td>A7</td><td>B7</td><td>GND</td></tr><tr><td>MCIO_2A_PWRBRK_CLKREQ_N</td><td>A8</td><td>B8</td><td>SMB_MCIO2A_SCL</td></tr><tr><td>MCIO_2A_SMB_ALERT_WAKE_N</td><td>A9</td><td>B9</td><td>SMB_MCIO2A_SDA</td></tr><tr><td>GND</td><td>A10</td><td>B10</td><td>GND</td></tr><tr><td>CLK0_100M_MCIO_2_DP</td><td>A11</td><td>B11</td><td>MCIO_2A_RST_N</td></tr><tr><td>CLK0_100M_MCIO_2_DN</td><td>A12</td><td>B12</td><td>MCIO_2A_PRSNT_N</td></tr><tr><td>GND</td><td>A13</td><td>B13</td><td>GND</td></tr><tr><td>MCIO_PCIE5_PE2_RX_2_DP</td><td>A14</td><td>B14</td><td>MCIO_PCIE5_PE2_TX_2_DP</td></tr><tr><td>MCIO_PCIE5_PE2_RX_2_DN</td><td>A15</td><td>B15</td><td>MCIO_PCIE5_PE2_TX_2_DN</td></tr><tr><td>GND</td><td>A16</td><td>B16</td><td>GND</td></tr><tr><td>MCIO_PCIE5_PE2_RX_3_DP</td><td>A17</td><td>B17</td><td>MCIO_PCIE5_PE2_TX_3_DP</td></tr><tr><td>MCIO_PCIE5_PE2_RX_3_DN</td><td>A18</td><td>B18</td><td>MCIO_PCIE5_PE2_TX_3_DN</td></tr><tr><td>GND</td><td>A19</td><td>B19</td><td>GND</td></tr><tr><td>MCIO_PCIE5_PE2_RX_4_DP</td><td>A20</td><td>B20</td><td>MCIO_PCIE5_PE2_TX_4_DP</td></tr><tr><td>MCIO_PCIE5_PE2_RX_4_DN</td><td>A21</td><td>B21</td><td>MCIO_PCIE5_PE2_TX_4_DN</td></tr><tr><td>GND</td><td>A22</td><td>B22</td><td>GND</td></tr><tr><td>MCIO_PCIE5_PE2_RX_5_DP</td><td>A23</td><td>B23</td><td>MCIO_PCIE5_PE2_TX_5_DP</td></tr><tr><td>MCIO_PCIE5_PE2_RX_5_DN</td><td>A24</td><td>B24</td><td>MCIO_PCIE5_PE2_TX_5_DN</td></tr><tr><td>GND</td><td>A25</td><td>B25</td><td>GND</td></tr><tr><td>NC</td><td>A26</td><td>B26</td><td>NC</td></tr><tr><td>NC</td><td>A27</td><td>B27</td><td>NC</td></tr><tr><td>GND</td><td>A28</td><td>B28</td><td>GND</td></tr><tr><td>NC</td><td>A29</td><td>B29</td><td>NC</td></tr><tr><td>NC</td><td>A30</td><td>B30</td><td>NC</td></tr><tr><td>GND</td><td>A31</td><td>B31</td><td>GND</td></tr><tr><td>MCIO_PCIE5_PE2_RX_6_DP</td><td>A32</td><td>B32</td><td>MCIO_PCIE5_PE2_TX_6_DP</td></tr><tr><td>MCIO_PCIE5_PE2_RX_6_DN</td><td>A33</td><td>B33</td><td>MCIO_PCIE5_PE2_TX_6_DN</td></tr><tr><td>GND</td><td>A34</td><td>B34</td><td>GND</td></tr><tr><td>MCIO_PCIE5_PE2_RX_7_DP</td><td>A35</td><td>B35</td><td>MCIO_PCIE5_PE2_TX_7_DP</td></tr><tr><td>MCIO_PCIE5_PE2_RX_7_DN</td><td>A36</td><td>B36</td><td>MCIO_PCIE5_PE2_TX_7_DN</td></tr><tr><td>GND</td><td>A37</td><td>B37</td><td>GND</td></tr><tr><td>GND</td><td>G1</td><td>N1</td><td>NC</td></tr><tr><td>GND</td><td>G2</td><td>N2</td><td>NC</td></tr><tr><td>GND</td><td>G3</td><td></td><td></td></tr><tr><td>GND</td><td>G4</td><td></td><td></td></tr></table>

MCIO\_CN3

<table><tr><td>Signal</td><td>Pin</td><td>Pin</td><td>Signal</td></tr><tr><td>GND</td><td>A1</td><td>B1</td><td>GND</td></tr><tr><td>MCIO_PCIE5_PE3_RX_0_DP</td><td>A2</td><td>B2</td><td>MCIO_PCIE5_PE3_TX_0_DP</td></tr><tr><td>MCIO_PCIE5_PE3_RX_0_DN</td><td>A3</td><td>B3</td><td>MCIO_PCIE5_PE3_TX_0_DN</td></tr><tr><td>GND</td><td>A4</td><td>B4</td><td>GND</td></tr><tr><td>MCIO_PCIE5_PE3_RX_1_DP</td><td>A5</td><td>B5</td><td>MCIO_PCIE5_PE3_TX_1_DP</td></tr><tr><td>MCIO_PCIE5_PE3_RX_1_DN</td><td>A6</td><td>B6</td><td>MCIO_PCIE5_PE3_TX_1_DN</td></tr><tr><td>GND</td><td>A7</td><td>B7</td><td>GND</td></tr><tr><td>MCIO_3A_PWRBRK_CLKREQ_N</td><td>A8</td><td>B8</td><td>SMB_MCIO3A_SCL</td></tr><tr><td>MCIO_3A_SMB_ALERT_WAKE_N</td><td>A9</td><td>B9</td><td>SMB_MCIO3A_SDA</td></tr><tr><td>GND</td><td>A10</td><td>B10</td><td>GND</td></tr><tr><td>CLK0_100M_MCIO_3_DP</td><td>A11</td><td>B11</td><td>MCIO_3A_RST_N</td></tr><tr><td>CLK0_100M_MCIO_3_DN</td><td>A12</td><td>B12</td><td>MCIO_3A_PRSNT_N</td></tr><tr><td>GND</td><td>A13</td><td>B13</td><td>GND</td></tr><tr><td>MCIO_PCIE5_PE3_RX_2_DP</td><td>A14</td><td>B14</td><td>MCIO_PCIE5_PE3_TX_2_DP</td></tr><tr><td>MCIO_PCIE5_PE3_RX_2_DN</td><td>A15</td><td>B15</td><td>MCIO_PCIE5_PE3_TX_2_DN</td></tr><tr><td>GND</td><td>A16</td><td>B16</td><td>GND</td></tr><tr><td>MCIO_PCIE5_PE3_RX_3_DP</td><td>A17</td><td>B17</td><td>MCIO_PCIE5_PE3_TX_3_DP</td></tr><tr><td>MCIO_PCIE5_PE3_RX_3_DN</td><td>A18</td><td>B18</td><td>MCIO_PCIE5_PE3_TX_3_DN</td></tr><tr><td>GND</td><td>A19</td><td>B19</td><td>GND</td></tr><tr><td>MCIO_PCIE5_PE3_RX_4_DP</td><td>A20</td><td>B20</td><td>MCIO_PCIE5_PE3_TX_4_DP</td></tr><tr><td>MCIO_PCIE5_PE3_RX_4_DN</td><td>A21</td><td>B21</td><td>MCIO_PCIE5_PE3_TX_4_DN</td></tr><tr><td>GND</td><td>A22</td><td>B22</td><td>GND</td></tr><tr><td>MCIO_PCIE5_PE3_RX_5_DP</td><td>A23</td><td>B23</td><td>MCIO_PCIE5_PE3_TX_5_DP</td></tr><tr><td>MCIO_PCIE5_PE3_RX_5_DN</td><td>A24</td><td>B24</td><td>MCIO_PCIE5_PE3_TX_5_DN</td></tr><tr><td>GND</td><td>A25</td><td>B25</td><td>GND</td></tr><tr><td>MCIO_3B_PWRBRK_CLKREQ_N</td><td>A26</td><td>B26</td><td>SMB_MCIO3B_SCL</td></tr><tr><td>MCIO_3B_SMB_ALERT_WAKE_N</td><td>A27</td><td>B27</td><td>SMB_MCIO3B_SDA</td></tr><tr><td>GND</td><td>A28</td><td>B28</td><td>GND</td></tr><tr><td>CLK1_100M_MCIO_3_DP</td><td>A29</td><td>B29</td><td>MCIO_3B_RST_N</td></tr><tr><td>CLK1_100M_MCIO_3_DN</td><td>A30</td><td>B30</td><td>MCIO_3B_PRSNT_N</td></tr><tr><td>GND</td><td>A31</td><td>B31</td><td>GND</td></tr><tr><td>MCIO_PCIE5_PE3_RX_6_DP</td><td>A32</td><td>B32</td><td>MCIO_PCIE5_PE3_TX_6_DP</td></tr><tr><td>MCIO_PCIE5_PE3_RX_6_DN</td><td>A33</td><td>B33</td><td>MCIO_PCIE5_PE3_TX_6_DN</td></tr><tr><td>GND</td><td>A34</td><td>B34</td><td>GND</td></tr><tr><td>MCIO_PCIE5_PE3_RX_7_DP</td><td>A35</td><td>B35</td><td>MCIO_PCIE5_PE3_TX_7_DP</td></tr><tr><td>MCIO_PCIE5_PE3_RX_7_DN</td><td>A36</td><td>B36</td><td>MCIO_PCIE5_PE3_TX_7_DN</td></tr><tr><td>GND</td><td>A37</td><td>B37</td><td>GND</td></tr><tr><td>GND</td><td>G1</td><td>N1</td><td>NC</td></tr><tr><td>GND</td><td>G2</td><td>N2</td><td>NC</td></tr><tr><td>GND</td><td>G3</td><td></td><td></td></tr><tr><td>GND</td><td>G4</td><td></td><td></td></tr></table>

# PCIe Slots (PCIe x8)

Location: PCIE\_CN1; PCIE\_CN2

Description: PCIe Slot 98P x8 ST

![Technical line drawing of a rectangular electronic component with mounting holes and a recessed slot (no text or symbols)](.axe-7420gwa-50m-22811-1000-02/6fbfc5d465eff65ad9469b597f347ade97bb972596abe4e31622c1249a62d2aa.jpg)

PCIE\_CN1

<table><tr><td>Signal</td><td>Pin</td><td>Pin</td><td>Signal</td></tr><tr><td>P_+12V_PSU</td><td>B1</td><td>A1</td><td>MCIO_1A_PWRBRK_CLKREQ_N</td></tr><tr><td>P_+12V_PSU</td><td>B2</td><td>A2</td><td>P_+12V_PSU</td></tr><tr><td>P_+12V_PSU</td><td>B3</td><td>A3</td><td>P_+12V_PSU</td></tr><tr><td>GND</td><td>B4</td><td>A4</td><td>GND</td></tr><tr><td>SMB_MCIO1A_SCL</td><td>B5</td><td>A5</td><td>NC</td></tr><tr><td>SMB_MCIO1A_SDA</td><td>B6</td><td>A6</td><td>NC</td></tr><tr><td>GND</td><td>B7</td><td>A7</td><td>NC</td></tr><tr><td>P_+3V3_S0</td><td>B8</td><td>A8</td><td>NC</td></tr><tr><td>NC</td><td>B9</td><td>A9</td><td>P_+3V3_S0</td></tr><tr><td>P_+3V3_S0</td><td>B10</td><td>A10</td><td>P_+3V3_S0</td></tr><tr><td>MCIO_1A_SMB_ALERT_WAKE_N</td><td>B11</td><td>A11</td><td>MCIO_1A_RST_N</td></tr><tr><td colspan="4">Separation Key</td></tr><tr><td>NC</td><td>B12</td><td>A12</td><td>GND</td></tr><tr><td>GND</td><td>B13</td><td>A13</td><td>CLK_100M_MCIO_1A_DP</td></tr><tr><td>MCIO_PCIE5_PE1_TX_0_DP</td><td>B14</td><td>A14</td><td>CLK_100M_MCIO_1A_DN</td></tr><tr><td>MCIO_PCIE5_PE1_TX_0_DN</td><td>B15</td><td>A15</td><td>GND</td></tr><tr><td>GND</td><td>B16</td><td>A16</td><td>MCIO_PCIE5_PE1_RX_0_DP</td></tr><tr><td>MCIO_1A_PRSNT_N</td><td>B17</td><td>A17</td><td>MCIO_PCIE5_PE1_RX_0_DN</td></tr><tr><td>GND</td><td>B18</td><td>A18</td><td>GND</td></tr><tr><td>MCIO_PCIE5_PE1_TX_1_DP</td><td>B19</td><td>A19</td><td>NC</td></tr><tr><td>MCIO_PCIE5_PE1_TX_1_DN</td><td>B20</td><td>A20</td><td>GND</td></tr><tr><td>GND</td><td>B21</td><td>A21</td><td>MCIO_PCIE5_PE1_RX_1_DP</td></tr><tr><td>GND</td><td>B22</td><td>A22</td><td>MCIO_PCIE5_PE1_RX_1_DN</td></tr><tr><td>MCIO_PCIE5_PE1_TX_2_DP</td><td>B23</td><td>A23</td><td>GND</td></tr><tr><td>MCIO_PCIE5_PE1_TX_2_DN</td><td>B24</td><td>A24</td><td>GND</td></tr><tr><td>GND</td><td>B25</td><td>A25</td><td>MCIO_PCIE5_PE1_RX_2_DP</td></tr><tr><td>GND</td><td>B26</td><td>A26</td><td>MCIO_PCIE5_PE1_RX_2_DN</td></tr><tr><td>MCIO_PCIE5_PE1_TX_3_DP</td><td>B27</td><td>A27</td><td>GND</td></tr><tr><td>MCIO_PCIE5_PE1_TX_3_DN</td><td>B28</td><td>A28</td><td>GND</td></tr><tr><td>GND</td><td>B29</td><td>A29</td><td>MCIO_PCIE5_PE1_RX_3_DP</td></tr><tr><td>NC</td><td>B30</td><td>A30</td><td>MCIO_PCIE5_PE1_RX_3_DN</td></tr><tr><td>MCIO_1A_PRSNT_N</td><td>B31</td><td>A31</td><td>GND</td></tr><tr><td>GND</td><td>B32</td><td>A32</td><td>NC</td></tr><tr><td>MCIO_PCIE5_PE1_TX_4_DP</td><td>B33</td><td>A33</td><td>NC</td></tr><tr><td>MCIO_PCIE5_PE1_TX_4_DN</td><td>B34</td><td>A34</td><td>GND</td></tr><tr><td>GND</td><td>B35</td><td>A35</td><td>MCIO_PCIE5_PE1_RX_4_DP</td></tr><tr><td>GND</td><td>B36</td><td>A36</td><td>MCIO_PCIE5_PE1_RX_4_DN</td></tr><tr><td>MCIO_PCIE5_PE1_TX_5_DP</td><td>B37</td><td>A37</td><td>GND</td></tr><tr><td>MCIO_PCIE5_PE1_TX_5_DN</td><td>B38</td><td>A38</td><td>GND</td></tr><tr><td>GND</td><td>B39</td><td>A39</td><td>MCIO_PCIE5_PE1_RX_5_DP</td></tr><tr><td>GND</td><td>B40</td><td>A40</td><td>MCIO_PCIE5_PE1_RX_5_DN</td></tr><tr><td>MCIO_PCIE5_PE1_TX_6_DP</td><td>B41</td><td>A41</td><td>GND</td></tr><tr><td>MCIO_PCIE5_PE1_TX_6_DN</td><td>B42</td><td>A42</td><td>GND</td></tr><tr><td>GND</td><td>B43</td><td>A43</td><td>MCIO_PCIE5_PE1_RX_6_DP</td></tr><tr><td>GND</td><td>B44</td><td>A44</td><td>MCIO_PCIE5_PE1_RX_6_DN</td></tr><tr><td>MCIO_PCIE5_PE1_TX_7_DP</td><td>B45</td><td>A45</td><td>GND</td></tr><tr><td>MCIO_PCIE5_PE1_TX_7_DN</td><td>B46</td><td>A46</td><td>GND</td></tr><tr><td>GND</td><td>B47</td><td>A47</td><td>MCIO_PCIE5_PE1_RX_7_DP</td></tr><tr><td>MCIO_1A_PRSNT_N</td><td>B48</td><td>A48</td><td>MCIO_PCIE5_PE1_RX_7_DN</td></tr><tr><td>GND</td><td>B49</td><td>A49</td><td>GND</td></tr><tr><td>NC</td><td>N1</td><td>N2</td><td>NC</td></tr><tr><td>GND</td><td>G1</td><td>G2</td><td>GND</td></tr></table>

PCIE\_CN2

<table><tr><td>Signal</td><td>Pin</td><td>Pin</td><td>Signal</td></tr><tr><td>P_+12V_PSU</td><td>B1</td><td>A1</td><td>MCIO_2A_PWRBRK_CLKREQ_N</td></tr><tr><td>P_+12V_PSU</td><td>B2</td><td>A2</td><td>P_+12V_PSU</td></tr><tr><td>P_+12V_PSU</td><td>B3</td><td>A3</td><td>P_+12V_PSU</td></tr><tr><td>GND</td><td>B4</td><td>A4</td><td>GND</td></tr><tr><td>SMB_MCIO2A_SCL</td><td>B5</td><td>A5</td><td>NC</td></tr><tr><td>SMB_MCIO2A_SDA</td><td>B6</td><td>A6</td><td>NC</td></tr><tr><td>GND</td><td>B7</td><td>A7</td><td>NC</td></tr><tr><td>P_+3V3_S0</td><td>B8</td><td>A8</td><td>NC</td></tr><tr><td>NC</td><td>B9</td><td>A9</td><td>P_+3V3_S0</td></tr><tr><td>P_+3V3_S0</td><td>B10</td><td>A10</td><td>P_+3V3_S0</td></tr><tr><td>MCIO_2A_SMB_ALERT_WAKE_N</td><td>B11</td><td>A11</td><td>MCIO_2A_RST_N</td></tr><tr><td colspan="4">Separation Key</td></tr><tr><td>NC</td><td>B12</td><td>A12</td><td>GND</td></tr><tr><td>GND</td><td>B13</td><td>A13</td><td>CLK_100M_MCIO_2A_DP</td></tr><tr><td>MCIO_PCIE5_PE2_TX_0_DP</td><td>B14</td><td>A14</td><td>CLK_100M_MCIO_2A_DN</td></tr><tr><td>MCIO_PCIE5_PE2_TX_0_DN</td><td>B15</td><td>A15</td><td>GND</td></tr><tr><td>GND</td><td>B16</td><td>A16</td><td>MCIO_PCIE5_PE2_RX_0_DP</td></tr><tr><td>MCIO_2A_PRSNT_N</td><td>B17</td><td>A17</td><td>MCIO_PCIE5_PE2_RX_0_DN</td></tr><tr><td>GND</td><td>B18</td><td>A18</td><td>GND</td></tr><tr><td>MCIO_PCIE5_PE2_TX_1_DP</td><td>B19</td><td>A19</td><td>NC</td></tr><tr><td>MCIO_PCIE5_PE2_TX_1_DN</td><td>B20</td><td>A20</td><td>GND</td></tr><tr><td>GND</td><td>B21</td><td>A21</td><td>MCIO_PCIE5_PE2_RX_1_DP</td></tr><tr><td>GND</td><td>B22</td><td>A22</td><td>MCIO_PCIE5_PE2_RX_1_DN</td></tr><tr><td>MCIO_PCIE5_PE2_TX_2_DP</td><td>B23</td><td>A23</td><td>GND</td></tr><tr><td>MCIO_PCIE5_PE2_TX_2_DN</td><td>B24</td><td>A24</td><td>GND</td></tr><tr><td>GND</td><td>B25</td><td>A25</td><td>MCIO_PCIE5_PE2_RX_2_DP</td></tr><tr><td>GND</td><td>B26</td><td>A26</td><td>MCIO_PCIE5_PE2_RX_2_DN</td></tr><tr><td>MCIO_PCIE5_PE2_TX_3_DP</td><td>B27</td><td>A27</td><td>GND</td></tr><tr><td>MCIO_PCIE5_PE2_TX_3_DN</td><td>B28</td><td>A28</td><td>GND</td></tr><tr><td>GND</td><td>B29</td><td>A29</td><td>MCIO_PCIE5_PE2_RX_3_DP</td></tr><tr><td>NC</td><td>B30</td><td>A30</td><td>MCIO_PCIE5_PE2_RX_3_DN</td></tr><tr><td>MCIO_2A_PRSNT_N</td><td>B31</td><td>A31</td><td>GND</td></tr><tr><td>GND</td><td>B32</td><td>A32</td><td>NC</td></tr><tr><td>MCIO_PCIE5_PE2_TX_4_DP</td><td>B33</td><td>A33</td><td>NC</td></tr><tr><td>MCIO_PCIE5_PE2_TX_4_DN</td><td>B34</td><td>A34</td><td>GND</td></tr><tr><td>GND</td><td>B35</td><td>A35</td><td>MCIO_PCIE5_PE2_RX_4_DP</td></tr><tr><td>GND</td><td>B36</td><td>A36</td><td>MCIO_PCIE5_PE2_RX_4_DN</td></tr><tr><td>MCIO_PCIE5_PE2_TX_5_DP</td><td>B37</td><td>A37</td><td>GND</td></tr><tr><td>MCIO_PCIE5_PE2_TX_5_DN</td><td>B38</td><td>A38</td><td>GND</td></tr><tr><td>GND</td><td>B39</td><td>A39</td><td>MCIO_PCIE5_PE2_RX_5_DP</td></tr><tr><td>GND</td><td>B40</td><td>A40</td><td>MCIO_PCIE5_PE2_RX_5_DN</td></tr><tr><td>MCIO_PCIE5_PE2_TX_6_DP</td><td>B41</td><td>A41</td><td>GND</td></tr><tr><td>MCIO_PCIE5_PE2_TX_6_DN</td><td>B42</td><td>A42</td><td>GND</td></tr><tr><td>GND</td><td>B43</td><td>A43</td><td>MCIO_PCIE5_PE2_RX_6_DP</td></tr><tr><td>GND</td><td>B44</td><td>A44</td><td>MCIO_PCIE5_PE2_RX_6_DN</td></tr><tr><td>MCIO_PCIE5_PE2_TX_7_DP</td><td>B45</td><td>A45</td><td>GND</td></tr><tr><td>MCIO_PCIE5_PE2_TX_7_DN</td><td>B46</td><td>A46</td><td>GND</td></tr><tr><td>GND</td><td>B47</td><td>A47</td><td>MCIO_PCIE5_PE2_RX_7_DP</td></tr><tr><td>MCIO_2A_PRSNT_N</td><td>B48</td><td>A48</td><td>MCIO_PCIE5_PE2_RX_7_DN</td></tr><tr><td>GND</td><td>B49</td><td>A49</td><td>GND</td></tr><tr><td>NC</td><td>N1</td><td>N2</td><td>NC</td></tr><tr><td>GND</td><td>G1</td><td>G2</td><td>GND</td></tr></table>

# PCIe Slots (PCIe x4)

Location: PCIE\_CN3; PCIE\_CN4

Description: PCIe Slot 64P x4 ST

![PCI-E 5.0](.axe-7420gwa-50m-22811-1000-02/6ad9a35321354f29f9137071dc35781e2908c3ae70f10bd94a6f8c3b9f872570.jpg)

PCIE\_CN3

<table><tr><td>Signal</td><td>Pin</td><td>Pin</td><td>Signal</td></tr><tr><td>P_+12V_PSU</td><td>B1</td><td>A1</td><td>MCIO_3A_PWRBRK_CLKREQ_N</td></tr><tr><td>P_+12V_PSU</td><td>B2</td><td>A2</td><td>P_+12V_PSU</td></tr><tr><td>P_+12V_PSU</td><td>B3</td><td>A3</td><td>P_+12V_PSU</td></tr><tr><td>GND</td><td>B4</td><td>A4</td><td>GND</td></tr><tr><td>SMB_MCIO3A_SCL</td><td>B5</td><td>A5</td><td>NC</td></tr><tr><td>SMB_MCIO3A_SDA</td><td>B6</td><td>A6</td><td>NC</td></tr><tr><td>GND</td><td>B7</td><td>A7</td><td>NC</td></tr><tr><td>P_+3V3_S0</td><td>B8</td><td>A8</td><td>NC</td></tr><tr><td>NC</td><td>B9</td><td>A9</td><td>P_+3V3_S0</td></tr><tr><td>P_+3V3_S0</td><td>B10</td><td>A10</td><td>P_+3V3_S0</td></tr><tr><td>MCIO_3A_SMB_ALERT_WAKE_N</td><td>B11</td><td>A11</td><td>MCIO_3A_RST_N</td></tr><tr><td colspan="4">Separation Key</td></tr><tr><td>NC</td><td>B12</td><td>A12</td><td>GND</td></tr><tr><td>GND</td><td>B13</td><td>A13</td><td>CLK_100M_MCIO_3A_DP</td></tr><tr><td>MCIO_PCIE5_PE3_TX_0_DP</td><td>B14</td><td>A14</td><td>CLK_100M_MCIO_3A_DN</td></tr><tr><td>MCIO_PCIE5_PE3_TX_0_DN</td><td>B15</td><td>A15</td><td>GND</td></tr><tr><td>GND</td><td>B16</td><td>A16</td><td>MCIO_PCIE5_PE3_RX_0_DP</td></tr><tr><td>MCIO_3A_PRSNT_N</td><td>B17</td><td>A17</td><td>MCIO_PCIE5_PE3_RX_0_DN</td></tr><tr><td>GND</td><td>B18</td><td>A18</td><td>GND</td></tr><tr><td>MCIO_PCIE5_PE3_TX_1_DP</td><td>B19</td><td>A19</td><td>NC</td></tr><tr><td>MCIO_PCIE5_PE3_TX_1_DN</td><td>B20</td><td>A20</td><td>GND</td></tr><tr><td>GND</td><td>B21</td><td>A21</td><td>MCIO_PCIE5_PE3_RX_1_DP</td></tr><tr><td>GND</td><td>B22</td><td>A22</td><td>MCIO_PCIE5_PE3_RX_1_DN</td></tr><tr><td>MCIO_PCIE5_PE3_TX_2_DP</td><td>B23</td><td>A23</td><td>GND</td></tr><tr><td>MCIO_PCIE5_PE3_TX_2_DN</td><td>B24</td><td>A24</td><td>GND</td></tr><tr><td>GND</td><td>B25</td><td>A25</td><td>MCIO_PCIE5_PE3_RX_2_DP</td></tr><tr><td>GND</td><td>B26</td><td>A26</td><td>MCIO_PCIE5_PE3_RX_2_DN</td></tr><tr><td>MCIO_PCIE5_PE3_TX_3_DP</td><td>B27</td><td>A27</td><td>GND</td></tr><tr><td>MCIO_PCIE5_PE3_TX_3_DN</td><td>B28</td><td>A28</td><td>GND</td></tr><tr><td>GND</td><td>B29</td><td>A29</td><td>MCIO_PCIE5_PE3_RX_3_DP</td></tr><tr><td>NC</td><td>B30</td><td>A30</td><td>MCIO_PCIE5_PE3_RX_3_DN</td></tr><tr><td>MCIO_3A_PRSNT_N</td><td>B31</td><td>A31</td><td>GND</td></tr><tr><td>GND</td><td>B32</td><td>A32</td><td>NC</td></tr><tr><td>NC</td><td>N1</td><td>N2</td><td>NC</td></tr><tr><td>GND</td><td>G1</td><td>G2</td><td>GND</td></tr></table>

PCIE\_CN4

<table><tr><td>Signal</td><td>Pin</td><td>Pin</td><td>Signal</td></tr><tr><td>P_+12V_PSU</td><td>B1</td><td>A1</td><td>MCIO_3B_PWRBRK_CLKREQ_N</td></tr><tr><td>P_+12V_PSU</td><td>B2</td><td>A2</td><td>P_+12V_PSU</td></tr><tr><td>P_+12V_PSU</td><td>B3</td><td>A3</td><td>P_+12V_PSU</td></tr><tr><td>GND</td><td>B4</td><td>A4</td><td>GND</td></tr><tr><td>SMB_MCIO3B_SCL</td><td>B5</td><td>A5</td><td>NC</td></tr><tr><td>SMB_MCIO3B_SDA</td><td>B6</td><td>A6</td><td>NC</td></tr><tr><td>GND</td><td>B7</td><td>A7</td><td>NC</td></tr><tr><td>P_+3V3_S0</td><td>B8</td><td>A8</td><td>NC</td></tr><tr><td>NC</td><td>B9</td><td>A9</td><td>P_+3V3_S0</td></tr><tr><td>P_+3V3_S0</td><td>B10</td><td>A10</td><td>P_+3V3_S0</td></tr><tr><td>MCIO_3B_SMB_ALERT_WAKE_N</td><td>B11</td><td>A11</td><td>MCIO_3B_RST_N</td></tr><tr><td colspan="4">Separation Key</td></tr><tr><td>NC</td><td>B12</td><td>A12</td><td>GND</td></tr><tr><td>GND</td><td>B13</td><td>A13</td><td>CLK_100M_MCIO_3B_DP</td></tr><tr><td>MCIO_PCIE5_PE3_TX_4_DP</td><td>B14</td><td>A14</td><td>CLK_100M_MCIO_3B_DN</td></tr><tr><td>MCIO_PCIE5_PE3_TX_4_DN</td><td>B15</td><td>A15</td><td>GND</td></tr><tr><td>GND</td><td>B16</td><td>A16</td><td>MCIO_PCIE5_PE3_RX_4_DP</td></tr><tr><td>MCIO_3B_PRSNT_N</td><td>B17</td><td>A17</td><td>MCIO_PCIE5_PE3_RX_4_DN</td></tr><tr><td>GND</td><td>B18</td><td>A18</td><td>GND</td></tr><tr><td>MCIO_PCIE5_PE3_TX_5_DP</td><td>B19</td><td>A19</td><td>NC</td></tr><tr><td>MCIO_PCIE5_PE3_TX_5_DN</td><td>B20</td><td>A20</td><td>GND</td></tr><tr><td>GND</td><td>B21</td><td>A21</td><td>MCIO_PCIE5_PE3_RX_5_DP</td></tr><tr><td>GND</td><td>B22</td><td>A22</td><td>MCIO_PCIE5_PE3_RX_5_DN</td></tr><tr><td>MCIO_PCIE5_PE3_TX_6_DP</td><td>B23</td><td>A23</td><td>GND</td></tr><tr><td>MCIO_PCIE5_PE3_TX_6_DN</td><td>B24</td><td>A24</td><td>GND</td></tr><tr><td>GND</td><td>B25</td><td>A25</td><td>MCIO_PCIE5_PE3_RX_6_DP</td></tr><tr><td>GND</td><td>B26</td><td>A26</td><td>MCIO_PCIE5_PE3_RX_6_DN</td></tr><tr><td>MCIO_PCIE5_PE3_TX_7_DP</td><td>B27</td><td>A27</td><td>GND</td></tr><tr><td>MCIO_PCIE5_PE3_TX_7_DN</td><td>B28</td><td>A28</td><td>GND</td></tr><tr><td>GND</td><td>B29</td><td>A29</td><td>MCIO_PCIE5_PE3_RX_7_DP</td></tr><tr><td>NC</td><td>B30</td><td>A30</td><td>MCIO_PCIE5_PE3_RX_7_DN</td></tr><tr><td>MCIO_3B_PRSNT_N</td><td>B31</td><td>A31</td><td>GND</td></tr><tr><td>GND</td><td>B32</td><td>A32</td><td>NC</td></tr><tr><td>NC</td><td>N1</td><td>N2</td><td>NC</td></tr><tr><td>GND</td><td>G1</td><td>G2</td><td>GND</td></tr></table>

# PCIe 12V Power Connectors

Location: CN1; CN2

Description: Power Header ML 2x4P

![VIEW A\n9.60\n1.00\n4.20\nVIEW B\nR0.30\n3.20±0.20\n4.20\n(PIN No-1)*4.2](.axe-7420gwa-50m-22811-1000-02/50116ba63b5c0c8a1ef8cf977dd1dc5ae8f195a27563feab5d421a489dcd05cd.jpg)

![3.17\n11.40\n2.90\nDIM.A\n7.30\n4.20](.axe-7420gwa-50m-22811-1000-02/a33d6b7b9190acc0f478e21924726731036af09724150580f3c072bbf3a03720.jpg)

CN1

<table><tr><td rowspan="5">&lt;img src="images/76eacc32e3029aaa29b5761cadfd9fbd9d9bef636d59fd242998baa98d59b7d8.jpg"/&gt;</td><td>PIN#</td><td>Signal Name</td><td>PIN#</td><td>Signal Name</td></tr><tr><td>1</td><td>P_+12V_PSU</td><td>5</td><td>CN1_SENSE0(10K ohm to GND)</td></tr><tr><td>2</td><td>P_+12V_PSU</td><td>6</td><td>GND</td></tr><tr><td>3</td><td>P_+12V_PSU</td><td>7</td><td>GND</td></tr><tr><td>4</td><td>CN1_SENSE1(10K ohm to GND)</td><td>8</td><td>GND</td></tr></table>

CN2

<table><tr><td rowspan="5">&lt;img src="images/1cfd44871971624c03122de21e75ba5cfe559efc168b3acfd2b5c5d151c74d29.jpg"/&gt;</td><td>PIN#</td><td>Signal Name</td><td>PIN#</td><td>Signal Name</td></tr><tr><td>1</td><td>P_+12V_PSU</td><td>5</td><td>CN2_SENSE0(10K ohm to GND)</td></tr><tr><td>2</td><td>P_+12V_PSU</td><td>6</td><td>GND</td></tr><tr><td>3</td><td>P_+12V_PSU</td><td>7</td><td>GND</td></tr><tr><td>4</td><td>CN2_SENSE1(10K ohm to GND)</td><td>8</td><td>GND</td></tr></table>

# System Fan Connectors

Location: FAN\_CN1; FAN\_CN2

Description: WAFER ML 1x4P ST D2.54

![Circuit 1\n2.54±0.10\n7.62±0.20](.axe-7420gwa-50m-22811-1000-02/9a584e248f8ac325af1bbfa7cbf4bf4c1fcc2a66cf694bb0c1f2ee2b6aa8f761.jpg)

![Isometric line drawing of a mechanical component with multiple pins (no text or symbols)](.axe-7420gwa-50m-22811-1000-02/f1739d8175303eada27c3478c4cf700f8be618dafd4e263855f000ad848ed36c.jpg)

# FAN\_CN1

![FAN_CN1](.axe-7420gwa-50m-22811-1000-02/7325f7ce1e4b70a1325ae5ca0f8020f252a52f8232f39ff649a81bb5802934da.jpg)

<table><tr><td>PIN#</td><td>Signal Name</td></tr><tr><td>1</td><td>GND</td></tr><tr><td>2</td><td>P_+12V_FAN1</td></tr><tr><td>3</td><td>FAN1_PWM_IN</td></tr><tr><td>4</td><td>FAN1_PWM_OUT</td></tr></table>

# FAN\_CN2

![FAN_CN2](.axe-7420gwa-50m-22811-1000-02/af673d61f4e9940824a2dd6436ec1db436cbbdc3ab1ba69b1d29b1ab2f38ca7a.jpg)

<table><tr><td>PIN#</td><td>Signal Name</td></tr><tr><td>1</td><td>GND</td></tr><tr><td>2</td><td>P_+12V_FAN2</td></tr><tr><td>3</td><td>FAN2_PWM_IN</td></tr><tr><td>4</td><td>FAN2_PWM_OUT</td></tr></table>

# SMBus Connector

Location: SMBUS1

Description: WAFER ML 1x5P ST D1.0

![Isometric line drawing of a rectangular electronic component with internal slots and mounting holes (no text or symbols)](.axe-7420gwa-50m-22811-1000-02/e88ca130f3ad6e733269e0b4c086322148774f0e3029420c5da5cba005b2bbb5.jpg)

# SMBUS1

<table><tr><td rowspan="8">SMBUS1
GND
BMC_SMBCCLK
BNC_SMBCCLK
BNC_SMBCCLK
GND
PART BNC
GND</td><td>PIN#</td><td>Signal Name</td></tr><tr><td>1</td><td>BMC_SMBCLK</td></tr><tr><td>2</td><td>BMC_SMBDAT</td></tr><tr><td>3</td><td>BMC_ALERT</td></tr><tr><td>4</td><td>GND</td></tr><tr><td>5</td><td>P_+3V3_BMC</td></tr><tr><td>G1</td><td>GND</td></tr><tr><td>G2</td><td>GND</td></tr></table>

This page intentionally left blank.

# Getting Started

# 6.1 Installing Memory Modules

Memory modules must be populated as shown (slots $1 > 2 > 3 > 4 > 5 > 6 )$ .

![Technical diagram of a computer motherboard with labeled components and numbered parts](.axe-7420gwa-50m-22811-1000-02/6163ea94bad021a42ad06ac3aed71a6a264445248dd971e8a6bac86a78d787ea.jpg)

Granite Rapids DDR5 only DIMM configurations diagram

<table><tr><td rowspan="2">DIMM Quantity</td><td colspan="8">AXE-7420GWA DIMM</td></tr><tr><td>DIMM3</td><td>DIMM4</td><td>DIMM1</td><td>DIMM2</td><td>DIMM6</td><td>DIMM5</td><td>DIMM8</td><td>DIMM7</td></tr><tr><td>1DIMM</td><td></td><td></td><td>V</td><td></td><td></td><td></td><td></td><td></td></tr><tr><td>1DIMM</td><td></td><td></td><td></td><td></td><td></td><td>V</td><td></td><td></td></tr><tr><td>2DIMM</td><td></td><td></td><td>V</td><td></td><td></td><td></td><td></td><td>V</td></tr><tr><td>2DIMM</td><td>V</td><td></td><td></td><td></td><td></td><td>V</td><td></td><td></td></tr><tr><td>4DIMM</td><td>V</td><td></td><td>V</td><td></td><td></td><td>V</td><td></td><td>V</td></tr><tr><td>8DIMM</td><td>V</td><td>V</td><td>V</td><td>V</td><td>V</td><td>V</td><td>V</td><td>V</td></tr></table>

# 6.2 PCIe Slot Secondary Power Supply

The AXE-7420GWA is equipped with two 8-pin ATX-type 12V power connectors on the mainboard (see section 4.2 Connector Locations) The pin definitions of the connectors and cables are described below.

![A yellow triangle with a black border containing a large black exclamation point in the center.](.axe-7420gwa-50m-22811-1000-02/00a86f0b51eed6448b8c176cefe6d780499227931a45d91342c61cdf413f61e6.jpg)
CAUTION:
mise en garde

All installation procedures are restricted to skilled personnel.

Toutes les procédures d'installation sont réservées au personnel qualifié.

# 8-Pin ATX-Type 12V Power Connector Pinout

<table><tr><td>Pin #</td><td>Signal</td></tr><tr><td>1</td><td>P12V</td></tr><tr><td>2</td><td>P12V</td></tr><tr><td>3</td><td>P12V</td></tr><tr><td>4</td><td>SENSE1</td></tr><tr><td>5</td><td>GND</td></tr><tr><td>6</td><td>SENSE0</td></tr><tr><td>7</td><td>GND</td></tr><tr><td>8</td><td>GND</td></tr></table>

![Pure architectural floor plan lines without any text, numbers, or symbols](.axe-7420gwa-50m-22811-1000-02/b7587f81a2002b0d6245455e3db0688dce7da6dd88a2116b226c8fbce914cc8a.jpg)

# 6.3 BMC LAN Configuration

Users can modify the BMC IP via ipmitool commands.

Show the current LAN setting

ipmitool lan print 1

# [Static IP]

Set the IP source to static

ipmitool lan set 1 ipsrc static

Set the IP address

ipmitool lan set 1 ipaddr xxx.xxx.xxx.xxx

Set the netmask address

ipmitool lan set 1 netmask xxx.xxx.xxx.xxx

Set the gateway address

ipmitool lan set 1 defgw ipaddr xxx.xxx.xxx.xxx

# [DHCP IP]

Set IP source to DHCP

ipmitool lan set 1 ipsrc dhcp

![The image displays a standard icon representing a document. It features a white sheet of paper with a folded top-right corner. Faint, horizontal gray lines run across the document, simulating text lines. A large, thick red checkmark is superimposed on the left side of the paper, indicating approval or completion.](.axe-7420gwa-50m-22811-1000-02/dedad9af9b8feddaae9f075ea1b7557f482272a958ce26ba4c23526e85e121bc.jpg)
NOTE:

BMC IP can be set in the BIOS.

# 6.4 BIOS Update

Users can update the AXE-7420GWA system BIOS via various interfaces (Gigabit LAN, KCS, and the console port).

# Updating BIOS via Host with BIOS Tool

1. Boot/Login to the Shell

2. Update the BIOS from the host using the following commands:

Example:

AfuEfix64 BIOS.ROM /p /b /n /x (to update BIOS without ME)

![FS0:\) cd AXE-7400GRW_00510_FullImage\nFS0:\AXE-7400GRW_00510_FullImage\) 1s\nDirectory of: FS0:\AXE-7400GRW_00510_FullImage\\n12/03/2025 14:54 (DIR)    16,384 .\n12/03/2025 14:54 (DIR)    0 ..\n12/03/2025 01:27    684,048    AfuEfix64.efi\n12/03/2025 01:27    50,331,648    AXE-7400GRW_00510.ROM\n12/03/2025 01:27    67,108,864    AXE-7400GRW_00510_Corporate.BIN\n12/03/2025 01:27    6,202    HISTORY.txt\n12/03/2025 01:27    405    pBIOS.nsh\n5 File(s) 118,131,167 bytes\n2 Dir(s)\nFSO:\AXE-7400GRW_00510_FullImage\)](.axe-7420gwa-50m-22811-1000-02/ea48136962cb2ac3790db972529f3622fee690d1a479a72b8bded8f58c082514.jpg)

![The image displays a simple line-art icon of a document. It features a white sheet of paper with a folded top-left corner and several horizontal black lines running across it, suggesting text. A large, thick red checkmark is superimposed over the center of the document.](.axe-7420gwa-50m-22811-1000-02/88290425aa3806753eb4eaafdbfd8161cb175557824f86a75f4062a5add83b7c.jpg)
NOTE:

Updating BIOS via BMC, please refer to Chapter 9 BMC.

# 6.5 BMC Firmware Update via Network

This section outlines the various methods available for updating the BMC firmware.

BMC firmware updates can be performed through four primary methods:

# 1. Web interface update

For detailed steps and guidelines, please refer to Section 8.2.8.1.1 BMC Update.

# 2. Redfish update

For detailed steps and guidelines, please refer to Section 8.4.4 BMC Update.

# 6.6 CPLD Update

This section outlines the various methods available for updating the BMC firmware.

BMC firmware updates can be performed through four primary methods:

# 1. Web interface update

For detailed steps and guidelines, please refer to Section 8.2.8.2.1 HPM Firmware Update-CPLD/BIOS.

# 2. Redfish update

For detailed steps and guidelines, please refer to Section 8.4.6 CPLD Update.

# 3. ipmitool update

For detailed steps and guidelines, please refer to Section 8.3.2.6 CPLD Update.

# 6.7 Create a RAID Volume

To create a RAID volume, the RAID option must be enabled in the BIOS so that the system loads the RAID option ROM code (see section 8.4.2.1 SATA Configuration)

1. Go to Chipset > PCH Configurations > SATA Configuration.
2. Set SATA Mode Selection to RAID, save changes, and reboot the system.

![Aptio Setup - AMI\nChipset\nSATA Configuration\nSATA Controller(s)	(Enabled)\nSATA Mode Selection	(AHCI)\nForce SATA Gen Speed	(Gen3)\nPort 0	(Not Installed)\nPort 0	(Enabled)\nPort 1	(Not Installed)\nPort 1	(Enabled)\nPort 2	(Not Installed)\nPort 2	(Enabled)\nPort 3	(Not Installed)\nPort 3	(Enabled)\nPort 4	(Not Installed)\nPort 4	(Enabled)\nPort 5	(Not Installed)\nPort 0	(Enabled)\nPort 6	(Not Installed)\nEnable/Disable SATA Device.\n+: Select Screen\n↑↓: Select Item\nEnter: Select\n+/-: Change Opt.\nF1: General Help\nF8: Previous Values\nF9: Optimized Defaults\nF10: Save & Exit\nESC: Exit\nVersion 2.22.1294 Copyright (C) 2025 AMI](.axe-7420gwa-50m-22811-1000-02/6c0e15217feafd34ab322735e8af21701993c48d5c294f965c85a7b713ff6292.jpg)

To create a RAID volume, go to the Advanced menu

![Aptio Setup - AMI\nMain Advanced Chipset Security Boot Save & Exit Server Mgmt\nCPU Configuration\nPower Management\nBIOS Watchdog Timer\nSuper IO Configuration\nSerial Port Console Redirection\nHardware Monitor\nTrusted Computing\nNVMe Configuration\nLAN Configuration\nUSB Configuration\nNetwork Stack Configuration\nAll Cpu Information\niSCSI Configuration\nIntel(R) EVROC SATA Controller\nIntel(R) Ethernet Controller I226-V -\n00:30:64:76:38:F8\nCoCPU Configuration\nce\ns.\n#\n#\n#\n#:\n#:\n#:(: Select Screen\n#: Select Item\n#Enter: Select\n#+/-: Change Opt.\n#F1: General Help\n#F8: Previous Values\n#F9: Optimized Defaults\n#F10: Save & Exit\nESC: Exit\nVersion 2.22.1294 Copyright (C) 2026 AMI\nAB](.axe-7420gwa-50m-22811-1000-02/85e8ece16e01318bbe2d8f50b6d75d631d3e282a82c36501b8a1eab76963ffae.jpg)

Enter the Intel(R) VROC sSATA Controller submenu and click on Create RAID Volume.

# BIOS Settings

To enter the BIOS setup screen, follow these steps:

1. Power on the AXE-7420GWA.
2. Press the &lt;Delete&gt; or &lt;ESC&gt; key on your keyboard when you see the following text prompt: “Press DEL or ESC to enter Setup”.
(Note: If Quick Boot is enabled, the screen below will not display, but pressing the &lt;Delete&gt; or &lt;ESC&gt; key will still allow you to enter the BIOS setup screen.)

![ami™\nVersion 2.22.1294. Copyright (C) 2025 AMI\nAXE-7400RGW REV:0.05.10\nPress (DEL) or (ESC) to enter setup.](.axe-7420gwa-50m-22811-1000-02/b6ea19ebd1c58a796e9745325cd0b1850fdcf6d6b57eba1873ae1c160a9b512b.jpg)

3. After pressing the &lt;Delete&gt; or &lt;ESC&gt; key, the main BIOS setup menu will display. You can access the other setup screens from the main BIOS setup menu, such as Chipset and Power menus.

# 7.1 BIOS Setup Menu

The BIOS setup utility is invoked by pressing &lt;ESC&gt; or &lt;DEL&gt; keys. User can change BIOS settings during setup utility runs. A system reset is required for new settings to take effect.

In the BIOS setup utility, there are several hot keys are designed for specific purposes, as listed below.

&lt;F1&gt;: General help in setup menu
&lt;F8&gt;: Load previous BIOS values
&lt;F9&gt;: Load BIOS default in setup utility
&lt;F10&gt;: Save & Exit setup utility

To navigate through the BIOS setup menu, use the following.

<table><tr><td>→←</td><td>Left/Right. The Left and Right &lt; Arrow &gt; keys allow you to select a setup screen.For example: Main screen, Advanced screen, Chipset screen, and so on.</td></tr><tr><td>↑↓</td><td>Up/Down The Up and Down &lt; Arrow &gt; keys allow you to select a setup item or sub-screen.</td></tr><tr><td>+-</td><td>Plus/Minus The Plus and Minus &lt; Arrow &gt; keys allow you to change the field value of a particular setup item.For example: Date and Time.</td></tr><tr><td>Tab</td><td>The &lt; Tab &gt; key allows you to select setup fields.</td></tr></table>

# Menu Selection Bar

The Menu Selection Bar is located at the top of the screen. It displays the top-level available menus to the user:

• Main Menu
• Advanced Menu
Chipset Menu
Security Menu
Boot Menu
Save & Exit Menu
Server Mgmt

# Menu Conventions

The appearance of the setup menu listed in this chapter is a sample to describe the item list. It is shown on a VT100 terminal via serial console. The menu conventions are as follows.

# Using color

The mandatory BIOS setup fields are in black. The BIOS setup fields currently not used are in grey. The display only strings are in black.

# Using brackets

Editable menu options are marketed with squares ‘[‘ and ‘]’ to distinguish them from display only fields that can’t be modified.

# 7.2 Main Menu

The Main Menu provides read-only information about the system and also allows you to set the system date and time. The tables below show screen shots of the Main menu details, submenus and settings.

<table><tr><td colspan="2">Main Advanced Chipset Security Boot Save &amp; Exit Server Mgmt</td></tr><tr><td>BIOS Information
BIOS Vendor American Megatrends Inc.
BIOS Version 0.05.10
Build Date 12/05/2025
ME FW Version 19.10.0.1267
System Information
Project Name AXE-7400GRW
CPU Board Version A1
CPU Brand String Intel(R) Xeon(R) 696X
CPU Frequency 2.40GHz
Total Memory 32768 MB (DDR5)
Memory Frequency 6400 MHz
PCH SKU W890
System Date [Thu 12/04/2025]
System Time [13:12:30]
Access Level Administrator</td><td>Set the Date. Use Tab to switch between Date elements.
Default Ranges:
Year: 1998-9999
Months: 1-12
Days: Dependent on month
Range of Years may vary.
+: Select Screen
↑↓: Select Item
Enter: Select
+/-: Change Opt.
F1: General Help
F8: Previous Values
F9: Optimized Defaults
F10: Save &amp; Exit
ESC: Exit</td></tr><tr><td colspan="2">Version 2.22.1294 Copyright (C) 2025 AMI</td></tr></table>

BIOS Information

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>BIOS Vendor</td><td>Info-only.American Megatrends</td><td>Display vendor name of system BIOS.</td></tr><tr><td>BIOS Version</td><td>Info-only.x.yy.zz</td><td>Display version of booting BIOS.</td></tr><tr><td>Build Date</td><td>Info-only.MM/DD/YYYY</td><td>It shows the date that BIOS was built.</td></tr><tr><td>MRC Version</td><td>Info-only.xxx.Ryy</td><td>Display the revision of MRC code which is implemented in BIOS.</td></tr><tr><td>ME FW Version</td><td>Info-only.ww:x.y.z.aaa</td><td>Display the version of Intel manageability firmware which is implemented in BIOS.</td></tr></table>

System Information

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>Project Name</td><td>Info-only.</td><td>Shows Project Name</td></tr><tr><td>CPU Board Version</td><td>Info-only.</td><td>Shows Main Board Version</td></tr><tr><td>CPU Brand String</td><td>Info-only.Intel(R) Core, ...</td><td>Shows what CPU is booting the system.</td></tr><tr><td>CPU Frequency</td><td>Info-only.XXXX MHz</td><td>Shows CPU frequency.</td></tr><tr><td>Total Memory</td><td>Info-only.XXXX MB (DDR4)</td><td>Shows total memory size used on the motherboard and memory type.</td></tr><tr><td>Memory Frequency</td><td>Info-only.XXXX MHz</td><td>Shows memory frequency.</td></tr><tr><td>System Date</td><td>MM/DD/YYYY</td><td>For configuring/showing system date. When setting the Date, usekey to switch between Date elements.</td></tr><tr><td>System Time</td><td>HH:MM:SS</td><td>For configuring/showing system time. When setting the Time, usekey to switch between Time elements.</td></tr><tr><td>Access Level</td><td>Info-only.Administrator/User</td><td>It shows what access level is used to enter BIOS setup menu.</td></tr></table>

# 7.3 Advanced Menu

This menu contains the Advance settings.

<table><tr><td colspan="2">Aptio Setup - AMI</td></tr><tr><td colspan="2">Main Advanced Chipset Security Boot Save &amp; Exit Server Mgmt</td></tr><tr><td rowspan="2">CPU ConfigurationPower ManagementBIOS Watchdog TimerSuper IO ConfigurationSerial Port Console RedirectionHardware MonitorTrusted ComputingNVMe ConfigurationLAN ConfigurationUSB ConfigurationNetwork Stack ConfigurationAll Cpu InformationIntel(R) Ethernet Controller I226-V -00:30:64:76:38:FAIntel(R) I210 Gigabit Network Connection -00:30:64:76:38:FB</td><td>CPU Configuration</td></tr><tr><td>+: Select Screen↑↓: Select ItemEnter: Select+/-: Change Opt.F1: General HelpF8: Previous ValuesF9: Optimized DefaultsF10: Save &amp; ExitESC: Exit</td></tr><tr><td colspan="2">Version 2.22.1294 Copyright (C) 2025 AMI</td></tr></table>

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>1CPU Configuration</td><td>Sub-Menu</td><td>For Cpu setting</td></tr><tr><td>2Power Management</td><td>Sub-Menu</td><td>For Power Management</td></tr><tr><td>3BIOS Watchdog Time</td><td>Sub-Menu</td><td>For BIOS Watchdog Time setting</td></tr><tr><td>4Super IO Configuration</td><td>Sub-Menu</td><td>For Super IO Configuration</td></tr><tr><td>5Serial Port Console Redirection</td><td>Sub-Menu</td><td>For configuring serial console</td></tr><tr><td>6Hardware Monitor</td><td>Sub-Menu</td><td>For Hardware Monitor</td></tr><tr><td>7Trusted Computing</td><td>Sub-Menu</td><td>For TPM settings</td></tr><tr><td>8NVMe Configuration</td><td>Sub-Menu</td><td>For NVMe Device Information</td></tr><tr><td>9Lan Configuration</td><td>Sub-Menu</td><td>For Lan settings</td></tr><tr><td>10USB Configuration</td><td>Sub-Menu</td><td>For USB settings</td></tr><tr><td>11Network Stack Configuration</td><td>Sub-Menu</td><td>For configuring Network Stack.</td></tr><tr><td></td><td></td><td></td></tr><tr><td>12All Cpu Information</td><td>Sub-Menu</td><td></td></tr><tr><td>13Intel(R) Ethernet Controller I226-V</td><td>Sub-Menu</td><td>Onboard Ethernet controller configuration loaded by EFI driver. The setup page is designed by Intel and is shown when running the Ethernet EFI driver. It is related to the “Network” settings on the Boot setup page.</td></tr><tr><td>14Intel(R) I210 Gigabit Network Connect</td><td>Sub-Menu</td><td>Onboard Ethernet controller configuration loaded by EFI driver. The setup page is designed by Intel and is shown when running the Ethernet EFI driver. It is related to the “Network” settings on the Boot setup page.</td></tr></table>

# CPU Configuration

<table><tr><td>Advanced</td><td>Aptio Setup - AMI</td></tr><tr><td>CPU ConfigurationEnable Intel(R) TXT Enable SMX VMX Hyper-threading Enable (LP) X2APIC is enabled ASPM Support (Global) Native ASPM SpeedStep (Pstates) Turbo Mode Energy Efficient Turbo Monitor MWAIT C1 to C1e Promotion</td><td>[Disabled][Disabled][Enabled][ALL LPs][Disabled][Disabled][Enabled][Enabled][Enabled][Enabled][Enabled]Enables Intel(R) TXT.+: Select Screen↑↓: Select ItemEnter: Select+/-: Change Opt.F1: General HelpF8: Previous ValuesF9: Optimized DefaultsF10: Save &amp; ExitESC: Exit</td></tr></table>

Version 2.22.1294 Copyright (C) 2026 AMI

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>Enable Intel(R) TXT</td><td>DisabledEnabled</td><td>Enables Intel(R) TXT.</td></tr><tr><td>Enable SMX</td><td>DisabledEnabled</td><td>Enables Safer Mode Extensions.</td></tr><tr><td>VMX</td><td>DisabledEnabled</td><td>Enables theVanderpoolTechnology, takes effect after reboot.</td></tr><tr><td>Hyper-Threading Enable (LP)</td><td>All LPsSingle LP</td><td>Enable Logical processor (software Method to Enable/Disable Logical Processor threads)</td></tr><tr><td></td><td></td><td></td></tr><tr><td>X2APIC is enable</td><td>Info</td><td></td></tr><tr><td>ASPM Support (Global)</td><td>DisabledEnabled</td><td>This option can disable ASPM support for all PCIe root ports.</td></tr><tr><td>Native ASPM</td><td>DisabledEnabled</td><td>Enabled - OS Controlled ASPM, Disabled - ASPM Off, AUTO - BIOS Controlled ASPM</td></tr><tr><td></td><td></td><td></td></tr><tr><td>SpeedStep (PStates)</td><td>DisabledEnabled</td><td>Enable/Disable EIST (P-States)</td></tr><tr><td>Turbo mode</td><td>DisabledEnabled</td><td>Enable/Disable processorTurboMode</td></tr><tr><td>Energy Efficient Turbo</td><td>DisabledEnabled</td><td>Enable/Disable Energy EfficientTurbo.Enable: MSR 0x1FC Bit[19] = 0, Disable: MSR 0x1FC Bit[19] =1.</td></tr><tr><td>Monitor MWAIT</td><td>DisabledEnabled</td><td>Allows Monitor and MWAIT instructions.</td></tr><tr><td>C1 to C1e Promotion</td><td>DisabledEnabled</td><td>CPU will promote C1 request to C1e state.</td></tr></table>

# Power Management

<table><tr><td colspan="2">Advanced Aptio Setup - AMI</td></tr><tr><td>Power Management
State After G3 [S0 State]
RTC Wake system from S5 [Disabled]</td><td>Specify what state to go to when power is re-applied after a power failure (G3 state).</td></tr><tr><td></td><td>+: Select Screen
↑↓: Select Item
Enter: Select
+/-: Change Opt.
F1: General Help
F8: Previous Values
F9: Optimized Defaults
F10: Save &amp; Exit
ESC: Exit</td></tr><tr><td colspan="2">Version 2.22.1294 Copyright (C) 2026 AMI</td></tr></table>

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>State After G3</td><td>S0 StateDisabledS5 StateLast State</td><td>To enable or disable WOL</td></tr><tr><td>RTC Wake system from S5</td><td>DisabledEnabledEnable and Set wake on time</td><td>Enable: Enable Wake on RTC feature but not set RTC wake up value(used for set RTC value by OS tool). Disable: Disable Wake on RTC feature. Enabled and set wake time: Enable System wake on alarm event and set wake on the day::hr::min::sec specified.</td></tr><tr><td>Wake Up hour</td><td>0</td><td></td></tr><tr><td>Wake Up minute</td><td>0</td><td></td></tr><tr><td>Wake Up second</td><td>0</td><td></td></tr></table>

# Super IO Configuration

<table><tr><td colspan="2">Aptio Setup - AMI</td></tr><tr><td>Advanced</td><td></td></tr><tr><td>Super IO Configuration
COM1 Mode Control [RS232]
COM2 Mode Control [RS232]
COM1 TX termination [Disable]
COM2 TX termination [Disable]</td><td>Select COM1 mode. RS232, RS422, RS485</td></tr><tr><td></td><td>+: Select Screen
↑↓: Select Item
Enter: Select
+/-: Change Opt.
F1: General Help
F8: Previous Values
F9: Optimized Defaults
F10: Save &amp; Exit
ESC: Exit</td></tr><tr><td colspan="2">Version 2.22.1294 Copyright (C) 2026 AMI</td></tr></table>

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>COM1 Mode Control</td><td>RS232RS422RS485</td><td>Select COM1 mode. RS232, RS422, RS485</td></tr><tr><td>COM2 Mode Control</td><td>RS232RS422RS485</td><td>Select COM2 mode. RS232, RS422, RS485</td></tr><tr><td></td><td></td><td></td></tr><tr><td>Com1 TX termination</td><td>DisabledEnabled</td><td>COM1 TX termination Enable/Disable</td></tr><tr><td>Com2 TX termination</td><td>DisabledEnabled</td><td>COM2 TX termination Enable/Disable</td></tr></table>

# Serial Port Console Redirection

<table><tr><td colspan="2">Aptio Setup - AMI Advanced</td></tr><tr><td>Super IO Configuration
COM1 Mode Control [RS232]
COM2 Mode Control [RS232]
COM1 TX termination [Disable]
COM2 TX termination [Disable]</td><td>Select COM1 mode. RS232, RS422, RS485</td></tr><tr><td></td><td>+: Select Screen
↑↓: Select Item
Enter: Select
+/-: Change Opt.
F1: General Help
F8: Previous Values
F9: Optimized Defaults
F10: Save &amp; Exit
ESC: Exit</td></tr><tr><td colspan="2">Version 2.22.1294 Copyright (C) 2026 AMI</td></tr></table>

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>Console Redirection</td><td>EnabledDisabled</td><td>Enable or disable serial port console redirection function.</td></tr><tr><td>Console Redirection Settings</td><td>Sub-Menu</td><td>For configuring serial port settings when console redirection function is enabled.</td></tr></table>

# Console Redirection Settings

<table><tr><td colspan="2">Aptio Setup - AMI Advanced</td></tr><tr><td>COM1
Console Redirection Settings</td><td rowspan="2">Emulation: ANSI:
Extended ASCII char set. VT100: ASCII char set. VT100Plus: Extends VT100 to support color, function keys, etc.
VT-UTF8: Uses UTF8 encoding to map Unicode</td></tr><tr><td>Terminal Type [ANSI]
Bits per second [115200]
Data Bits [8]
Parity [None]
Stop Bits [1]
Flow Control [None]
VT-UTF8 Combo Key [Enabled]</td></tr><tr><td>Support
Recorder Mode [Disabled]
Resolution 100x31 [Disabled]
Putty KeyPad [VT100]</td><td>+: Select Screen
↑↓: Select Item
Enter: Select
+/-: Change Opt.
F1: General Help
F8: Previous Values
F9: Optimized Defaults
F10: Save &amp; Exit
ESC: Exit</td></tr><tr><td colspan="2">Version 2.22.1294 Copyright (C) 2025 AMI</td></tr></table>

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>Terminal Type</td><td>VT100VT100+VT-UTF8ANSI</td><td>Configure type of console emulation.Emulation:ANSI: Extended ASCII char set.VT100: ASCII char set.VT100+: Extends VT100 to support color, function keys, etc.VT-UTF8: Uses UTF8 encoding to map Unicode chars onto 1 or more bytes.</td></tr><tr><td>Bits per second</td><td>9600192003840057600115200</td><td>Selects serial port transmission speed. The speed must be matched on the other side. Long or noisy lines may require lower speed.</td></tr><tr><td>Data Bits</td><td>78</td><td>Configure the number of data bits in each transmitted or received serial character for both serial ports.</td></tr><tr><td>Parity</td><td>NoneEvenOddMarkSpace</td><td>Configures if parity bit is generated (transmit data) or checked.A parity bit can be sent with the data bits to detect some transmission errors. Even: parity bit is 0 if the num of 1&#x27;s in the data bits is even. Odd: parity bit is 0 if num of 1&#x27;s in the data bits is odd. Mark: parity bit is always 1. Space: Parity bit is always 0. Mark and Space Parity do not allow for error detection. They can be used as an additional data bit.</td></tr><tr><td>Stop Bits</td><td>12</td><td>Configures the number of stop bits transmitted and received in each serial character for both serial ports.Stop bits indicate the end of a serial data packet. (A start bit indicates the beginning). The standard setting is 1 stop bit. Communication with slow devices may require more than 1 stop bit.</td></tr><tr><td>Flow Control</td><td>NoneHardware RTS/CTS</td><td>Configures flow control for console redirection. Hardware flow control uses RTC/CTS.</td></tr><tr><td>VT-UTF8 Combo Key Support</td><td>DisabledEnabled</td><td>Enable VT-UTF8 Combination Key Support for ANSI/VT100 terminals</td></tr><tr><td>Recorder Mode</td><td>DisabledEnabled</td><td>This mode only text wil be sent</td></tr><tr><td>Resolution 100x31</td><td>DisabledEnabled</td><td>To enable or disable extended terminal resolution</td></tr><tr><td>Putty Keypad</td><td>VT100</td><td>Select Function Key and keypad on Putty</td></tr></table>

# Trusted Computing

<table><tr><td colspan="2">Aptio Setup - AMI Advanced</td></tr><tr><td rowspan="2">Configuration Security Device [Enabled] Support</td><td>Enables or Disables BIOS support for security device. 0.S. will not show Security Device. TCG EFI protocol and INT1A interface will not be available.</td></tr><tr><td>+:-: Select Screen ↑↓: Select Item Enter: Select +/-: Change Opt. F1: General Help F8: Previous Values F9: Optimized Defaults F10: Save &amp; Exit ESC: Exit</td></tr><tr><td colspan="2">Version 2.22.1294 Copyright (C) 2025 AMI</td></tr></table>

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>Security Device Support</td><td>EnabledDisabled</td><td>Security Device Support</td></tr></table>

# NVMe Configuration

![Aptio Setup - AMI\nAdvanced\nNVMe Configuration\n► TS500GMTE110Q\n++\n: Select Screen\n↑↓: Select Item\nEnter: Select\n+/-: Change Opt.\nF1: General Help\nF8: Previous Values\nF9: Optimized Defaults\nF10: Save & Exit\nESC: Exit\nVersion 2.22.1294 Copyright (C) 2025 AMI](.axe-7420gwa-50m-22811-1000-02/59267248a722dc1336efc82a20ec31e0b3326f7f821873ec90af28c4a3782422.jpg)

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>NVME Info</td><td>Sub-Menu</td><td>Dynamically generated information for NVME</td></tr></table>

<table><tr><td colspan="3">Aptio Setup - AMI</td></tr><tr><td colspan="3">Advanced</td></tr><tr><td>Seg:Bus:Dev:Func</td><td>00:0B:00:00</td><td rowspan="9">Select either Short or Extended Self Test. Short option will take couple of minutes and extended option will take several minutes to complete.</td></tr><tr><td>Model Number</td><td>TS500GMTE110Q</td></tr><tr><td>Total Size</td><td>500.1 GB</td></tr><tr><td>Vendor ID</td><td>1D79</td></tr><tr><td>Device ID</td><td>5766</td></tr><tr><td>Namespace: 1</td><td>Size: 500.1 GB</td></tr><tr><td>Device Self Test:Self Test Option</td><td>[Short]</td></tr><tr><td>Self Test Action</td><td>[Controller Only Test]</td></tr><tr><td>Run Device Self Test</td><td></td></tr><tr><td>Short Device Selftest Result</td><td>[Not Available]</td><td rowspan="2">+: Select Screen↑↓: Select ItemEnter: Select+/-: Change Opt.F1: General HelpF8: Previous ValuesF9: Optimized DefaultsF10: Save &amp; ExitESC: Exit</td></tr><tr><td>Extended Device Selftest Result</td><td>[Not Available]</td></tr></table>

# VGA Configuration

<table><tr><td>Advanced</td><td colspan="2">Aptio Setup - AMI</td></tr><tr><td rowspan="2" colspan="2">VGA ConfigurationOnboard VGA Enable [Enabled]</td><td>Enable or Disable Onboard VGA</td></tr><tr><td>+: Select Screen↑↓: Select ItemEnter: Select+/-: Change Opt.F1: General HelpF8: Previous ValuesF9: Optimized DefaultsF10: Save &amp; ExitESC: Exit</td></tr><tr><td colspan="3">Version 2.22.1294 Copyright (C) 2026 AMI</td></tr></table>

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>Onboard VGA Enable</td><td>DisabledEnabled</td><td>Enable or Disable onboard VGA</td></tr></table>

# LAN Configuration

![Advanced\nLAN Configuration\nOnboard LAN1 Control (i226) (Enabled)\nOnboard LAN2 Control (i210) (Enabled)\nEnable/Disable LAN 1 Controller\n+: Select Screen\n↑↓: Select Item\nEnter: Select\n+/-: Change Opt.\nF1: General Help\nF8: Previous Values\nF9: Optimized Defaults\nF10: Save & Exit\nESC: Exit\nVersion 2.22.1294 Copyright (C) 2026 AMI](.axe-7420gwa-50m-22811-1000-02/d054af3a0bb02ad7f551af91ee8ac779c6cbac81cbb326bfb1d73b64628409d2.jpg)

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>Onboard LAN1 control (i226)</td><td>EnabledDisabled</td><td>Enable/Disable Lan 1 Controller</td></tr><tr><td>Onboard LAN2 control (i210)</td><td>EnabledDisabled</td><td>Enable/Disable Lan 2 Controller</td></tr></table>

# USB Configuration

![Aptio Setup - AMI\nAdvanced\nUSB Configuration\nUSB Module Version 40\nUSB Controllers:\n1 XHCI\nUSB Devices:\n9 Drives, 2 Keyboards, 1 Mouse, 1 Hub\nXHCI Hand-off (Enabled)\nUSB Mass Storage Driver Support (Enabled)\nUSB hardware delays and time-outs:\nUSB transfer time-out (20 sec)\nDevice reset time-out (20 sec)\nDevice power-up delay (Auto)\nMass Storage Devices:\nADLINK Virtual CDROM0 1.00 (Auto)\nADLINK Virtual HDisk0 1.00 (Auto)\nKingstonDT microDuo 3C PMAP (Auto)\nADLINK Virtual CDROM1 1.00 (Auto)\nADLINK Virtual CDROM2 1.00 (Auto)\nADLINK Virtual CDROM3 1.00 (Auto)\nADLINK Virtual HDisk1 1.00 (Auto)\nThis is a workaround for OSes without XHCI hand-off support.\nThe XHCI ownership change should be claimed by XHCI driver.\n+: Select Screen\n↑↓: Select Item\nEnter: Select\n+/-: Change Opt.\nF1: General Help\nF8: Previous Values\nF9: Optimized Defaults\nF10: Save & Exit\nESC: Exit\nVersion 2.22.1294 Copyright (C) 2026 AMI](.axe-7420gwa-50m-22811-1000-02/80d48536bac2d025ff56d8b18f483619b8f07d4989fa7a10648bf06d388ef47f.jpg)

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>XHCI Hand-off</td><td>EnabledDisabled</td><td>This is a workaround for OSes without XHCI hand-off support. The XHCI ownership change should be claimed by XHCI driver.</td></tr><tr><td>USB Mass Storage Driver Support</td><td>EnabledDisabled</td><td>Configure the USB Mass Storage Devices.</td></tr><tr><td></td><td></td><td></td></tr><tr><td>USB transfer time-out</td><td>1 Sec5Sec10 Sec20 Sec</td><td>The time-out value for Control, Bulk, and Interrupt transfers</td></tr><tr><td>Device reset time-out</td><td>10 Sec20 Sec30 Sec40 Sec</td><td>USB mass storage device Start Unit command time-out.</td></tr><tr><td>Device power-up delay</td><td>AutoManual</td><td>Maximum time the device will take before it properly reports itself to the Host Controller. &#x27;Auto&#x27; uses default value: for a Root port it is 100 ms, for a Hub port the delay is taken from Hub descriptor.</td></tr></table>

# Miscellaneous

<table><tr><td colspan="2">Aptio Setup - AMI Advanced</td></tr><tr><td>Miscellaneous
PCIE Resizable BAR Support [Enabled]
Resizable BAR Max Size 26</td><td>Enable/Disable PCIE Resizable BAR Support</td></tr><tr><td></td><td>+: Select Screen
↑↓: Select Item
Enter: Select
+/-: Change Opt.
F1: General Help
F8: Previous Values
F9: Optimized Defaults
F10: Save &amp; Exit
ESC: Exit</td></tr><tr><td colspan="2">Version 2.22.1294 Copyright (C) 2026 AMI</td></tr></table>

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>PCIE Resizable BAR Support</td><td>DisabledEnabled</td><td>Enable/Disable PCIE Resizable BAR Support</td></tr><tr><td>Resizable BAR Max size</td><td>numeric</td><td>Set platform limit for max size to pick from Resizable BAR Capability register.Decimal value 'n' is interpreted as 2^(n+20), which means 0=&gt;1MB, 1=&gt;2MB, 2=&gt;4MB, 3=&gt;8MB, etc.Maximum possible to set is half of processor address width, i.e. address width - 1.</td></tr></table>

# Network Stack Configuration

<table><tr><td colspan="2">Aptio Setup - AMI Advanced</td></tr><tr><td rowspan="2">Network Stack Configuration
Network Stack [Enabled]
IPv4 PXE Support [Disabled]
IPv4 HTTP Support [Disabled]
IPv6 PXE Support [Disabled]
IPv6 HTTP Support [Disabled]
PXE boot wait time 0
Media detect count 1</td><td>Enable/Disable UEFI Network Stack</td></tr><tr><td>+: Select Screen
↑↓: Select Item
Enter: Select
+/-: Change Opt.
F1: General Help
F8: Previous Values
F9: Optimized Defaults
F10: Save &amp; Exit
ESC: Exit</td></tr><tr><td colspan="2">Version 2.22.1294 Copyright (C) 2025 AMI</td></tr></table>

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>Network stack</td><td>EnabledDisabled</td><td>Enable/Disable UEFI Network Stack</td></tr><tr><td>IPv4 PXESupport</td><td>EnabledDisabled</td><td>Enable/Disable IPv4 PXE boot support. If disabled, IPv4 PXE boot support will not be available.</td></tr><tr><td>IPv4 HTTP Support</td><td>EnabledDisabled</td><td>Enable/Disable IPv4 HTTP boot support. If disabled, IPv4 HTTP boot support will not be available.</td></tr><tr><td>IPv6 PXESupport</td><td>EnabledDisabled</td><td>Enable/Disable IPv6 PXE boot support. If disabled, IPv6 PXE boot support will not be available.</td></tr><tr><td>IPv4 HTTP Support</td><td>EnabledDisabled</td><td>Enable/Disable IPv6 HTTP boot support. If disabled, IPv4 HTTP boot support will not be available.</td></tr><tr><td>PXE Boot wait time</td><td>0</td><td>Wait time in seconds to press ESC key to abort the PXE boot. Use either +/- or numeric keys to set the value</td></tr><tr><td>Media detect count</td><td>1</td><td>Number of times the presence of media will be checked. Use either +/- or numeric keys to set the value.</td></tr></table>

# All CPU Information

![Aptio Setup - AMI\nAdvanced\nTotal CPU Number: 128\nCPU0\nCPUID: 000A06D1\nStepping: 1\nMicroCodeRev: 01000140\nPlatformID: 0004000000000000\nCoreFreq(MHz): 2400\nActCpuFreq(MHz): 2376\nCPU1\nCPUID: 000A06D1\nStepping: 1\nMicroCodeRev: 01000140\nPlatformID: 0004000000000000\nCoreFreq(MHz): 2400\nActCpuFreq(MHz): 2376\nCPU2\nCPUID: 000A06D1\nStepping: 1\nMicroCodeRev: 01000140\nPlatformID: 0004000000000000\nCoreFreq(MHz): 2400\nActCpuFreq(MHz): 2376\nCPU3\nCPUID: 000A06D1\nStepping: 1\n++: Select Screen\n↑↓: Select Item\nEnter: Select\n+/-: Change Opt.\nF1: General Help\nF8: Previous Values\nF9: Optimized Defaults\nF10: Save & Exit\nESC: Exit\nVersion 2.22.1294 Copyright (C) 2025 AMI](.axe-7420gwa-50m-22811-1000-02/aee76b3e2943ab84b43e1b4650abc5bf3205f71daad46b2f44aeeefc8383144d.jpg)

# Intel(R) Ethernet Controller I226-V

<table><tr><td colspan="3">Aptio Setup - AMI Advanced</td></tr><tr><td></td><td></td><td rowspan="6">How long the UEFI PXE driver should wait for link</td></tr><tr><td>UEFI Driver:</td><td>Intel(R) Ethernet Controller 2.5G 1.0.5</td></tr><tr><td>PCI Device ID</td><td>125C</td></tr><tr><td>PCI Address</td><td>2D:00:00</td></tr><tr><td>MAC Address</td><td>00:30:64:76:38:FA</td></tr><tr><td>Link Status</td><td>Disconnected</td></tr><tr><td>Link auto-negotiation Timeout</td><td>8</td><td>+: Select Screen ↑↓: Select Item Enter: Select +/-: Change Opt. F1: General Help F8: Previous Values F9: Optimized Defaults F10: Save &amp; Exit ESC: Exit</td></tr><tr><td colspan="3">Version 2.22.1294 Copyright (C) 2025 AMI</td></tr></table>

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>Link auto-negotiationTimeout</td><td>8</td><td>How long the UEFI PXE driver should wait for link</td></tr></table>

# Intel(R) I210 Gigabit Network Connect

<table><tr><td colspan="2">Aptio Setup - AMI Advanced</td></tr><tr><td>Firmware Image Properties
NIC Configuration</td><td>View device firmware version information.</td></tr><tr><td>Blink LEDs 0</td><td></td></tr><tr><td>UEFI Driver Intel(R) PRO/1000
9.8.33 PCI-E</td><td></td></tr><tr><td>Adapter PBA 000300-000</td><td></td></tr><tr><td>Device Name Intel(R) I210 Gigabit Network Connection</td><td></td></tr><tr><td>Chip Type Intel i210</td><td rowspan="6">+: Select Screen
↑↓: Select Item
Enter: Select
+/-: Change Opt.
F1: General Help
F8: Previous Values
F9: Optimized Defaults
F10: Save &amp; Exit
ESC: Exit</td></tr><tr><td>PCI Device ID 1533</td></tr><tr><td>PCI Address 30:00:00</td></tr><tr><td>Link Status [Disconnected]</td></tr><tr><td>MAC Address 00:30:64:76:38:FB</td></tr><tr><td>Virtual MAC Address 00:00:00:00:00:00</td></tr><tr><td colspan="2">Version 2.22.1294 Copyright (C) 2025 AMI</td></tr></table>

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>Firmware Image Properties</td><td>Sub-Menu</td><td>View device firmware version information</td></tr><tr><td>NIC Configuration</td><td>Sub-Menu</td><td></td></tr><tr><td>Blink LEDs</td><td>0</td><td></td></tr></table>

# 7.4 Chipset Menu

This menu contains the Chipset settings.

![Aptio Setup - AMI\nMain Advanced Chipset Security Boot Save & Exit Server Mgmt\nSocket Configurations\nPCH Configuration\nChipset Security Configuration\nSocket Configurations\n+: Select Screen\n↑↓: Select Item\nEnter: Select\n+/-: Change Opt.\nF1: General Help\nF8: Previous Values\nF9: Optimized Defaults\nF10: Save & Exit\nESC: Exit\nVersion 2.22.1294 Copyright (C) 2025 AMI](.axe-7420gwa-50m-22811-1000-02/604d339ccb2af4d98b53f4cd7230141c4d3264a122642b5a95040f8d605a8867.jpg)

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>Socket Configurations</td><td>Sub-Menu</td><td>For Socket Configurations.</td></tr><tr><td>PCH Configurations</td><td>Sub-Menu</td><td>For PCH Configurations.</td></tr><tr><td>Chipset Security Configurations</td><td>Sub-Menu</td><td>For Chipset Security Configurations</td></tr></table>

# Socket Configuration

![Aptio Setup - AMI\nChipset\nSocket Configurations\n► IIO Configurations\n► Memory Configurations\nIIO Configurations\n+: Select Screen\n↑↓: Select Item\nEnter: Select\n+/-: Change Opt.\nF1: General Help\nF8: Previous Values\nF9: Optimized Defaults\nF10: Save & Exit\nESC: Exit\nVersion 2.22.1294 Copyright (C) 2025 AMI](.axe-7420gwa-50m-22811-1000-02/8a09bc7a063497b07a3948e0670e7448ffe1d8c6be0848e55ed030851cf09407.jpg)

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>IIO Configurations</td><td>Sub-Menu</td><td>For IIO Configurations</td></tr><tr><td>Memory Configurations</td><td>Sub-Menu</td><td>For Memory Configurations</td></tr></table>

# IIO Configurations

<table><tr><td colspan="2">Aptio Setup - AMI</td></tr><tr><td>Chipset</td><td></td></tr><tr><td rowspan="2">IIO Configurations
►PCIE_CN3/PCIE_CN6/M.2_CN2/M.2_CN3
►PCIE_CN2/PCIE_CN5
►MCIO_CN1/MCIO_CN2
►PCIE_CN7
►PCIE_CN4
►MCIO_CN3/MCIO_CN4
►PCIE_CN1</td><td>PCIE_CN3/PCIE_CN6/M.2_CN2/M.2_CN3</td></tr><tr><td>+: Select Screen
↑↓: Select Item
Enter: Select
+/-: Change Opt.
F1: General Help
F8: Previous Values
F9: Optimized Defaults
F10: Save &amp; Exit
ESC: Exit</td></tr><tr><td colspan="2">Version 2.22.1294 Copyright (C) 2025 AMI</td></tr></table>

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>PCIE_CN3/PCIE_CN6/M.2_CN2/M.2_CN3</td><td>Sub-Menu</td><td>For PCIE_CN3/PCIE_CN6/M.2_CN2/M.2_CN3</td></tr><tr><td>PCIE_CN2/PCIE_CN5</td><td>Sub-Menu</td><td>For PCIE_CN2/PCIE_CN5</td></tr><tr><td>MCIO_CN1/MCIO_CN2</td><td>Sub-Menu</td><td>For MCIO_CN1/MCIO_CN2</td></tr><tr><td>PCIE_CN7</td><td>Sub-Menu</td><td>For PCIE_CN7</td></tr><tr><td>PCIE_CN4</td><td>Sub-Menu</td><td>For PCIE_CN4</td></tr><tr><td>MCIO_CN1/MCIO_CN2</td><td>Sub-Menu</td><td>For MCIO_CN1/MCIO_CN2</td></tr><tr><td>PCIE_CN1</td><td>Sub-Menu</td><td>For PCIE_CN1</td></tr></table>

# 7.4.1.1.1 PCIE\_CN3/PCIE\_CN6/M.2\_CN2/M.2\_CN3

<table><tr><td colspan="2">Aptio Setup - AMI Chipset</td></tr><tr><td>PCIE_CN3/PCIE_CN6/M.2_CN2/M.2_CN3
--------[---]</td><td rowspan="10">Press &lt;Enter&gt; to bring up the Intel VMD for Volume Management Device Configuration menu.</td></tr><tr><td>Intel VMD technology
Bifurcation [x4x4x4x4]</td></tr><tr><td>Port A</td></tr><tr><td>Port B</td></tr><tr><td>Port C</td></tr><tr><td>Port D</td></tr><tr><td>Port E</td></tr><tr><td>Port F</td></tr><tr><td>Port G</td></tr><tr><td>Port H</td></tr><tr><td></td><td>+: Select Screen
↑↓: Select Item
Enter: Select
+/-: Change Opt.
F1: General Help
F8: Previous Values
F9: Optimized Defaults
F10: Save &amp; Exit
ESC: Exit</td></tr><tr><td colspan="2">Version 2.22.1294 Copyright (C) 2025 AMI</td></tr></table>

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>Intel VMD technology</td><td>Sub-Menu</td><td>Pressto bring up the Intel VMD for Volume Management Device Configuration menu.</td></tr><tr><td>Bifurcation</td><td>Autox4x4x4x4x4x4x_x8x_x8x4x4x_x8x_x_x16x2x2x4x_x8x4x2x2x_x8x_x8x2x2x4x2x2x4x4x4x2x2x4x4x4x4x2x2x4x2x2x2x2x_x8x2x2x2x4x4x2x2x4x2x2x2x2x4x2x2x2x2x2x4x_x8x4x2x2x4x4x4x4x2x2x2x8x2x2x4x4x2x2x4x4x2x2x4x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x</td><td>Selects PCIe port Bifurcation for selected slot(s)Port Format: xGxExCxAThe port can further be x2x2</td></tr><tr><td>Port A</td><td>Sub-Menu</td><td></td></tr><tr><td>Port B</td><td>Sub-Menu</td><td></td></tr><tr><td>Port C</td><td>Sub-Menu</td><td></td></tr><tr><td>Port D</td><td>Sub-Menu</td><td></td></tr><tr><td>Port E</td><td>Sub-Menu</td><td></td></tr><tr><td>Port F</td><td>Sub-Menu</td><td></td></tr><tr><td>Port G</td><td>Sub-Menu</td><td></td></tr><tr><td>Port H</td><td>Sub-Menu</td><td></td></tr></table>

# 7.4.1.1.2 PCIE\_CN2/PCIE\_CN5

<table><tr><td colspan="2">Aptio Setup - AMI
Chipset</td></tr><tr><td>PCIE_CN2/PCIE_CN5
--------[x_x8x_x8]</td><td rowspan="10">Press &lt;Enter&gt; to bring up the Intel VMD for Volume Management Device Configuration menu.</td></tr><tr><td>▶Intel VMD technology
Bifurcation</td></tr><tr><td>▶Port A</td></tr><tr><td>▶Port B</td></tr><tr><td>▶Port C</td></tr><tr><td>▶Port D</td></tr><tr><td>▶Port E</td></tr><tr><td>▶Port F</td></tr><tr><td>▶Port G</td></tr><tr><td>▶Port H</td></tr><tr><td></td><td>+: Select Screen
↑↓: Select Item
Enter: Select
+/-: Change Opt.
F1: General Help
F8: Previous Values
F9: Optimized Defaults
F10: Save &amp; Exit
ESC: Exit</td></tr><tr><td colspan="2">Version 2.22.1294 Copyright (C) 2025 AMI</td></tr></table>

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>Intel VMD technology</td><td>Sub-Menu</td><td>Pressto bring up the Intel VMD for Volume Management Device Configuration menu.</td></tr><tr><td>Bifurcation</td><td>Autox4x4x4x4x4x4x_x8x_x8x4x4x_x8x_x_x16x2x2x4x_x8x4x2x2x_x8x_x8x2x2x4x2x2x4x4x4x4x4x4x4x4x4x4x2x2x2x4x2x2x2x2x_x8x2x2x2x2x4x4x2x2x2x2x4x2x2x2x2x2x4x2x2x2x2x2x2x4x_x8x4x2x2x4x4x4x4x2x2x2x_x8x2x2x2x2x2x2x2x4x4x2x2x2x2x4x4x2x2x2x2x4x4x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x</td><td>Selects PCIe port Bifurcation for selected slot(s)Port Format: xGxExCxAThe port can further be x2x2</td></tr><tr><td>Port A</td><td>Sub-Menu</td><td></td></tr><tr><td>Port B</td><td>Sub-Menu</td><td></td></tr><tr><td>Port C</td><td>Sub-Menu</td><td></td></tr><tr><td>Port D</td><td>Sub-Menu</td><td></td></tr><tr><td>Port E</td><td>Sub-Menu</td><td></td></tr><tr><td>Port F</td><td>Sub-Menu</td><td></td></tr><tr><td>Port G</td><td>Sub-Menu</td><td></td></tr><tr><td>Port H</td><td>Sub-Menu</td><td></td></tr></table>

# 7.4.1.1.3 MCIO\_CN1/MCIO\_CN2

![Aptio Setup - AMI\nChipset\nMCIO_CN1/MCIO_CN2\n--------)\nIntel VMD technology\nBifurcation (x_x8x_x8)\nPort A\nPort B\nPort C\nPort D\nPort E\nPort F\nPort G\nPort H\nPress (Enter) to bring up the Intel VMD for Volume Management Device Configuration menu.\n+: Select Screen\n↑↓: Select Item\nEnter: Select\n+/-: Change Opt.\nF1: General Help\nF8: Previous Values\nF9: Optimized Defaults\nF10: Save & Exit\nESC: Exit\nVersion 2.22.1294 Copyright (C) 2025 AMI](.axe-7420gwa-50m-22811-1000-02/dadd406f4926a0e091626e5c28e5922b330b5d9c32100053e6b1bb8793591817.jpg)

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>Intel VMD technology</td><td>Sub-Menu</td><td>Pressto bring up the Intel VMD for Volume Management Device Configuration menu.</td></tr><tr><td>Bifurcation</td><td>Autox4x4x4x4x4x4x_x8x_x8x4x4x_x8x_x_x_x16x2x2x4x_x8x4x2x2x_x8x_x8x2x2x4x4x4x2x2x4x4x4x4x2x2x4x2x2x2x2x_x8x2x2x2x2x4x4x2x4x2x2x4x4x2x2x2x2x4x2x2x2x2x2x2x4x_x8x4x2x2x4x4x4x4x2x2x2x8x8x2x2x2x2x2x2x2x4x4x2x2x2x2x2x4x4x2x2x2x2x2x2x4x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2xx4x2x2x2x2x2x2</td><td>Selects PCIe port Bifurcation for selected slot(s)Port Format: xGxExCxAThe port can further be x2x2</td></tr><tr><td>Port A</td><td>Sub-Menu</td><td></td></tr><tr><td>Port B</td><td>Sub-Menu</td><td></td></tr><tr><td>Port C</td><td>Sub-Menu</td><td></td></tr><tr><td>Port D</td><td>Sub-Menu</td><td></td></tr><tr><td>Port E</td><td>Sub-Menu</td><td></td></tr><tr><td>Port F</td><td>Sub-Menu</td><td></td></tr><tr><td>Port G</td><td>Sub-Menu</td><td></td></tr><tr><td>Port H</td><td>Sub-Menu</td><td></td></tr></table>

# 7.4.1.1.4 PCIE\_CN7

![Aptio Setup - AMI\nChipset\nPCIE_CN7\n--------)\n▶ Intel VMD technology\nBifurcation (Auto)\n▶ Port A\n▶ Port B\n▶ Port C\n▶ Port D\n▶ Port E\n▶ Port F\n▶ Port G\n▶ Port H\nPress (Enter) to bring up the Intel VMD for Volume Management Device Configuration menu.\n+:-: Select Screen\n↑↓: Select Item\nEnter: Select\n+/-: Change Opt.\nF1: General Help\nF8: Previous Values\nF9: Optimized Defaults\nF10: Save & Exit\nESC: Exit\nVersion 2.22.1294 Copyright (C) 2025 AMI](.axe-7420gwa-50m-22811-1000-02/c40b0f6111f274a925a617350c2ee55848dbf30f71706eb5d4d1268eb9ac0e39.jpg)

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>Intel VMD technology</td><td>Sub-Menu</td><td>Pressto bring up the Intel VMD for Volume Management Device Configuration menu.</td></tr><tr><td>Bifurcation</td><td>Autox4x4x4x4x4x4x_x8x_x8x4x4x_x8x_x_x16x2x2x4x_x8x4x2x2x_x8x_x8x2x2x4x4x4x2x2x4x4x4x4x2x2x4x2x2x2x2x_x8x2x2x2x2x4x4x2x2x4x2x2x4x4x2x2x2x2x2x4</td><td>Selects PCIe port Bifurcation for selected slot(s)Port Format: xGxExCxAThe port can further be x2x2</td></tr><tr><td></td><td>x_x8x4x2x2x4x4x4x2x2x_x8x2x2x2x2x2x2x4x4x2x2x4x2x2x4x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x</td><td></td></tr><tr><td>Port A</td><td>Sub-Menu</td><td></td></tr><tr><td>Port B</td><td>Sub-Menu</td><td></td></tr><tr><td>Port C</td><td>Sub-Menu</td><td></td></tr><tr><td>Port D</td><td>Sub-Menu</td><td></td></tr><tr><td>Port E</td><td>Sub-Menu</td><td></td></tr><tr><td>Port F</td><td>Sub-Menu</td><td></td></tr><tr><td>Port G</td><td>Sub-Menu</td><td></td></tr><tr><td>Port H</td><td>Sub-Menu</td><td></td></tr></table>

# 7.4.1.1.5 PCIE\_CN4

![Aptio Setup - AMI\nChipset\nPCIE_CN4\n--------)\n---------- Intel VMD technology\nBifurcation (Auto)\n▶ Port A\n▶ Port B\n▶ Port C\n▶ Port D\n▶ Port E\n▶ Port F\n▶ Port G\n▶ Port H\nPress (Enter) to bring up the Intel VMD for Volume Management Device Configuration menu.\n+:-: Select Screen\n↑↓: Select Item\nEnter: Select\n+/-: Change Opt.\nF1: General Help\nF8: Previous Values\nF9: Optimized Defaults\nF10: Save & Exit\nESC: Exit\nVersion 2.22.1294 Copyright (C) 2025 AMI](.axe-7420gwa-50m-22811-1000-02/2697bb92ef7846eed3a3df41868ea2d60f417da28ebe359781409154d5850f20.jpg)

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>Intel VMD technology</td><td>Sub-Menu</td><td>Pressto bring up the Intel VMD for Volume Management Device Configuration menu.</td></tr><tr><td>Bifurcation</td><td>Autox4x4x4x4x4x4x_x8x_x8x4x4x_x8x_x_x16x2x2x4x_x8x4x2x2x_x8x_x8x2x2x4x2x2x4x4x4x2x2x4x4x4x4x2x2x4x2x2x2x2x_x8x2x2x2x4x4x2x4x2x2x4x4x2x2x2x2x4x2x2x2x2x2x2x4x_x8x4x2x2x4x4x4x4x2x2x2x_x8x2x2x2x2x2x2x2x4x4x2x2x4x2x2x4x4x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x</td><td>Selects PCIe port Bifurcation for selected slot(s)Port Format: xGxExCxAThe port can further be x2x2</td></tr><tr><td>Port A</td><td>Sub-Menu</td><td></td></tr><tr><td>Port B</td><td>Sub-Menu</td><td></td></tr><tr><td>Port C</td><td>Sub-Menu</td><td></td></tr><tr><td>Port D</td><td>Sub-Menu</td><td></td></tr><tr><td>Port E</td><td>Sub-Menu</td><td></td></tr><tr><td>Port F</td><td>Sub-Menu</td><td></td></tr><tr><td>Port G</td><td>Sub-Menu</td><td></td></tr><tr><td>Port H</td><td>Sub-Menu</td><td></td></tr></table>

# 7.4.1.1.6 MCIO\_CN3/MCIO\_CN4

<table><tr><td colspan="2">Aptio Setup - AMI
Chipset</td></tr><tr><td rowspan="2">MCIO_CN3/MCIO_CN4
--------&gt;
► Intel VMD technology
Bifurcation [x_x8x_x8]
► Port A
► Port B
► Port C
► Port D
► Port E
► Port F
► Port G
► Port H</td><td>Press &lt;Enter&gt; to bring up the Intel VMD for Volume Management Device Configuration menu.</td></tr><tr><td>+: Select Screen
↑↓: Select Item
Enter: Select
+/-: Change Opt.
F1: General Help
F8: Previous Values
F9: Optimized Defaults
F10: Save &amp; Exit
ESC: Exit</td></tr></table>

Version 2.22.1294 Copyright (C) 2025 AMI

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>Intel VMD technology</td><td>Sub-Menu</td><td>Pressto bring up the Intel VMD for Volume Management Device Configuration menu.</td></tr><tr><td>Bifurcation</td><td>Autox4x4x4x4x4x4x_x8x_x8x4x4x_x8x_x_x16x2x2x4x_x8x4x2x2x_x8x_x8x2x2x4x2x2x4x4x4x2x2x4x4x4x4x2x2x4x2x2x2x2x_x8x2x2x2x4x4x2x2x4x2x2x2x4x2x2x2x2x4x2x2x2x2x2x4x_x8x4x2x2x4x4x4x4x2x2x2x8x8x2x2x2x2x2x2x2x4x4x2x2x2x2x4x4x2x2x2x2x2x4x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x</td><td>Selects PCIe port Bifurcation for selected slot(s)Port Format: xGxExCxAThe port can further be x2x2</td></tr><tr><td>Port A</td><td>Sub-Menu</td><td></td></tr><tr><td>Port B</td><td>Sub-Menu</td><td></td></tr><tr><td>Port C</td><td>Sub-Menu</td><td></td></tr><tr><td>Port D</td><td>Sub-Menu</td><td></td></tr><tr><td>Port E</td><td>Sub-Menu</td><td></td></tr><tr><td>Port F</td><td>Sub-Menu</td><td></td></tr><tr><td>Port G</td><td>Sub-Menu</td><td></td></tr><tr><td>Port H</td><td>Sub-Menu</td><td></td></tr></table>

# 7.4.1.1.7 PCIE\_CN1

![Aptio Setup - AMI\nChipset\nPCIE_CN1\n--------)\n▶ Intel VMD technology\nBifurcation (Auto)\n▶ Port A\n▶ Port B\n▶ Port C\n▶ Port D\n▶ Port E\n▶ Port F\n▶ Port G\n▶ Port H\nPress (Enter) to bring up the Intel VMD for Volume Management Device Configuration menu.\n+:-: Select Screen\n↑↓: Select Item\nEnter: Select\n+/-: Change Opt.\nF1: General Help\nF8: Previous Values\nF9: Optimized Defaults\nF10: Save & Exit\nESC: Exit\nVersion 2.22.1294 Copyright (C) 2025 AMI](.axe-7420gwa-50m-22811-1000-02/644b7ed3f57c83572f42cf94a9955348f2e966ad73fb675c4452121fce69b679.jpg)

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>Intel VMD technology</td><td>Sub-Menu</td><td>Pressto bring up the Intel VMD for Volume Management Device Configuration menu.</td></tr><tr><td>Bifurcation</td><td>Autox4x4x4x4x4x4x_x8x_x8x4x4x_x8x_x_x16x2x2x4x_x8x4x2x2x_x8x_x8x2x2x4x4x2x2x4x4x4x2x2x4x4x4x4x2x2x4x2x2x2x2x_x8x2x2x2x4x4x2x2x4x2x2x4x4x2x2x2x2x4x2x2x2x2x2x2x4x_x8x4x2x2x4x4x4x4x2x2x2x8x8x2x2x2x2x2x2x2x4x4x2x2x2x2x2x4x4x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x2x</td><td>Selects PCIe port Bifurcation for selected slot(s)Port Format: xGxExCxAThe port can further be x2x2</td></tr><tr><td>Port A</td><td>Sub-Menu</td><td></td></tr><tr><td>Port B</td><td>Sub-Menu</td><td></td></tr><tr><td>Port C</td><td>Sub-Menu</td><td></td></tr><tr><td>Port D</td><td>Sub-Menu</td><td></td></tr><tr><td>Port E</td><td>Sub-Menu</td><td></td></tr><tr><td>Port F</td><td>Sub-Menu</td><td></td></tr><tr><td>Port G</td><td>Sub-Menu</td><td></td></tr><tr><td>Port H</td><td>Sub-Menu</td><td></td></tr></table>

# Memory Configurations

<table><tr><td colspan="2">Chipset Aptio Setup - AMI</td></tr><tr><td>Memory Configurations
Host Memory Frequency [Auto]
► Memory Topology</td><td>Maximum Host DDR Memory
Frequency Selections in MT/s.
If the &quot;AUTO&quot; option has been selected, a frequency is chosen automatically based on the minimum tCK given by the SPD. If Enforce POR is disabled, user will be able to run at higher frequencies than the memory support (limited by processor support). Note: For</td></tr><tr><td></td><td>+: Select Screen
↑↓: Select Item
Enter: Select
+/-: Change Opt.
F1: General Help
F8: Previous Values
F9: Optimized Defaults
F10: Save &amp; Exit
ESC: Exit</td></tr><tr><td colspan="2">Version 2.22.1294 Copyright (C) 2026 AMI</td></tr></table>

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>Host Memory Frequency</td><td>Auto48005200560060006400</td><td>Maximum Host DDR Memory FrequencySelections in MT/s. If the &quot;AUTO&quot; optionhas been selected, a frequency is chosenautomatically based on the minimum tCKgiven by the SPD. If Enforce POR isdisabled, user will be able to run at higherfrequencies than the memory support(limited by processor support). Note: ForMRDIMM, DDR DRAM frequency is half ofHost frequency</td></tr><tr><td>Memory Topology</td><td>Sub-Menu</td><td>Displays memory topology with Dimmpopulation information</td></tr></table>

# 7.4.1.2.1 Memory Topology

![Aptio Setup - AMI\nChipset\n\nSocket0.ChC.Dimm0: 6400MT/s Actica DRx8 32GB RDIMM\n\n++: Select Screen\n↑↓: Select Item\nEnter: Select\n+/-: Change Opt.\nF1: General Help\nF8: Previous Values\nF9: Optimized Defaults\nF10: Save & Exit\nESC: Exit\n\nVersion 2.22.1294 Copyright (C) 2025 AMI](.axe-7420gwa-50m-22811-1000-02/465604a6403cf80f80f6b8e3813fea208d5d957ec0a63abce2117aacea35e4ca.jpg)

# PCH Configurations

![Aptio Setup - AMI\nChipset\nPCH Configuration\n▶ SATA Configuration\nSATA Device Options Settings\n+: Select Screen\n↑↓: Select Item\nEnter: Select\n+/-: Change Opt.\nF1: General Help\nF8: Previous Values\nF9: Optimized Defaults\nF10: Save & Exit\nESC: Exit\nVersion 2.22.1294 Copyright (C) 2025 AMI](.axe-7420gwa-50m-22811-1000-02/5296b7b6de3018f573e28dba0b6731ba98d2555ab85c866d0c997fac4d350cc8.jpg)

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>SATA Configuration</td><td>Sub-Menu</td><td>SATA Device options Settings</td></tr></table>

# SATA Configuration

![Chipset\nAptio Setup - AMI\nSATA Configuration\nSATA Controller(s)	(Enabled)\nSATA Mode Selection	(AHCI)\nForce SATA Gen Speed	(Gen3)\nPort 0	(Not Installed)\nPort 0	(Enabled)\nHot Plug	(Disabled)\nPort 1	(Not Installed)\nPort 1	(Enabled)\nHot Plug	(Disabled)\nPort 2	(Not Installed)\nPort 2	(Enabled)\nHot Plug	(Disabled)\nPort 3	(Not Installed)\nPort 3	(Enabled)\nHot Plug	(Disabled)\nPort 4	(Not Installed)\nPort 4	(Enabled)\nHot Plug	(Disabled)\nEnable/Disable SATA Device.\n++: Select Screen\n↑↓: Select Item\nEnter: Select\n+/-: Change Opt.\nF1: General Help\nF8: Previous Values\nF9: Optimized Defaults\nF10: Save & Exit\nESC: Exit\nVersion 2.22.1294 Copyright (C) 2026 AMI](.axe-7420gwa-50m-22811-1000-02/30d3453b9b585e4d3ac868edd47f10a68d73bd2d916ce542dd1a0e89a0f5300c.jpg)

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>SATA Controller(s)</td><td>EnabledDisabled</td><td>Enable/Disable SATA Device.</td></tr><tr><td>SATA Mode Selection</td><td>AHCIRAID</td><td>Determines how SATA controller(s) operate.</td></tr><tr><td>Force SATA Gen Speed</td><td>Gen1Gen2Gen3</td><td>Changes SATA Gen Speed for port.</td></tr><tr><td>Port 0</td><td>Not Installed</td><td>Software Preserve</td></tr><tr><td>Port 0</td><td>EnabledDisabled</td><td>Enable or Disable SATA Port</td></tr><tr><td>Hot Plug</td><td>Enabled/Disabled</td><td>Designates this port as Hot Pluggable.</td></tr><tr><td>Port 1</td><td>Not Installed</td><td>Software Preserve</td></tr><tr><td>Port 1</td><td>EnabledDisabled</td><td>Enable or Disable SATA Port</td></tr><tr><td>Hot Plug</td><td>Enabled/Disabled</td><td>Designates this port as Hot Pluggable.</td></tr><tr><td>Port 2</td><td>Not Installed</td><td>Software Preserve</td></tr><tr><td>Port 2</td><td>EnabledDisabled</td><td>Enable or Disable SATA Port</td></tr><tr><td>Hot Plug</td><td>Enabled/Disabled</td><td>Designates this port as Hot Pluggable.</td></tr><tr><td>Port 3</td><td>Not Installed</td><td>Software Preserve</td></tr><tr><td>Port 3</td><td>EnabledDisabled</td><td>Enable or Disable SATA Port</td></tr><tr><td>Hot Plug</td><td>Enabled/Disabled</td><td>Designates this port as Hot Pluggable.</td></tr><tr><td>Port 4</td><td>Not Installed</td><td>Software Preserve</td></tr><tr><td>Port 4</td><td>EnabledDisabled</td><td>Enable or Disable SATA Port</td></tr><tr><td>Hot Plug</td><td>Enabled/Disabled</td><td>Designates this port as Hot Pluggable.</td></tr><tr><td>Port 5</td><td>Not Installed</td><td>Software Preserve</td></tr><tr><td>Port 5</td><td>EnabledDisabled</td><td>Enable or Disable SATA Port</td></tr><tr><td>Hot Plug</td><td>Enabled/Disabled</td><td>Designates this port as Hot Pluggable.</td></tr><tr><td>Port 6</td><td>Not Installed</td><td>Software Preserve</td></tr><tr><td>Port 6</td><td>EnabledDisabled</td><td>Enable or Disable SATA Port</td></tr><tr><td>Hot Plug</td><td>Enabled/Disabled</td><td>Designates this port as Hot Pluggable.</td></tr><tr><td>Port 7</td><td>Not Installed</td><td>Software Preserve</td></tr><tr><td>Port 7</td><td>EnabledDisabled</td><td>Enable or Disable SATA Port</td></tr><tr><td>Hot Plug</td><td>Enabled/Disabled</td><td>Designates this port as Hot Pluggable.</td></tr></table>

# Chipset Security Configurations

<table><tr><td colspan="2">Chipset Setup - AMI</td></tr><tr><td>Chipset Security Configuration
BIOS Lock [Disabled]
Global Reset Lock [Auto]
SPD Write Disable [True]</td><td>Enable/Disable the IBL BIOS Lock Enable feature. Required to be enabled to ensure SMM protection of flash.</td></tr><tr><td></td><td>+: Select Screen
↑↓: Select Item
Enter: Select
+/-: Change Opt.
F1: General Help
F8: Previous Values
F9: Optimized Defaults
F10: Save &amp; Exit
ESC: Exit</td></tr><tr><td colspan="2">Version 2.22.1294 Copyright (C) 2025 AMI</td></tr></table>

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>BIOS Lock</td><td>DisabledEnabled</td><td>Enable/Disable the IBL BIOS Lock Enable feature. Required to be enabled to ensure SMM protection of flash.</td></tr><tr><td>Global Reset Lock</td><td>DisableEnableAuto</td><td>Enable/Disable locking global host reset</td></tr><tr><td>SPD Write Disable</td><td>TrueFalse</td><td>Enable/Disable setting SPD Write Disable. For security recommendations, SPD write disable bit must be set.</td></tr></table>

# 7.5 Security Menu

<table><tr><td colspan="2">Aptio Setup - AMI</td></tr><tr><td colspan="2">Main Advanced Chipset Security Boot Save &amp; Exit Server Mgmt</td></tr><tr><td rowspan="2">Password Description
If ONLY the Administrator&#x27;s password is set, then this only limits access to Setup and is only asked for when entering Setup.
If ONLY the User&#x27;s password is set, then this is a power on password and must be entered to boot or enter Setup. In Setup the User will have Administrator rights.
The password length must be in the following range:
Minimum length 3
Maximum length 20
Administrator Password
User Password
Secure Boot</td><td>Set Administrator Password</td></tr><tr><td>+: Select Screen
↑↓: Select Item
Enter: Select
+/-: Change Opt.
F1: General Help
F8: Previous Values
F9: Optimized Defaults
F10: Save &amp; Exit
ESC: Exit</td></tr><tr><td colspan="2">Version 2.22.1294 Copyright (C) 2025 AMI</td></tr></table>

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>Administrator Password</td><td>Enter to set password</td><td>Configure/Clear Administrator Password.When pressing enter, a menu will be popped up for creating new password. When password installed, press enter without inputting password, it will clear password.</td></tr><tr><td>User Password</td><td>Enter to set password</td><td>Configure/Clear User Password. When pressing enter, a menu will be popped up for creating new password. When password installed, press enter without inputting password, it will clear password.</td></tr><tr><td>Secure Boot</td><td>Sub-Menu</td><td>Secure Boot Menu. Default is Disabled.</td></tr></table>

# 7.6 Boot Menu

This menu contains the settings for bootable devices in the system.

![Aptio Setup - AMI\nMain Advanced Chipset Security Boot Save & Exit Server Mgmt\nBoot Configuration\nSetup Prompt Timeout 1\nBootup NumLock State (On)\nQuiet Boot (Enabled)\nFast Boot (Disabled)\nFIXED BOOT ORDER Priorities\nBoot Option #1 (Hard Disk)\nBoot Option #2 (NVME)\nBoot Option #3 (CD/DVD)\nBoot Option #4 (SD)\nBoot Option #5 (USB Hard Disk)\nBoot Option #6 (USB CD/DVD)\nBoot Option #7 (USB Key:UEFI:\nJetFlashTranscend 32GB\n1100, Partition 1)\nBoot Option #8 (USB Floppy)\nBoot Option #9 (USB Lan)\nBoot Option #10 (Network)\n► UEFI USB Key Drive BBS Priorities\nNumber of seconds to wait for\nsetup activation key. The\nmaximum value is 8\n+: Select Screen\n↑↓: Select Item\nEnter: Select\n+/-: Change Opt.\nF1: General Help\nF8: Previous Values\nF9: Optimized Defaults\nF10: Save & Exit\nESC: Exit\nVersion 2.22.1294 Copyright (C) 2025 AMI](.axe-7420gwa-50m-22811-1000-02/853a27d83df67ed0e46ca666e680d1ecbcf7ae21085b4f7d9c18737ccf3001e7.jpg)

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>Setup Prompt Timeout</td><td>1</td><td>Number of seconds to wait for setup activation</td></tr><tr><td>Bootup NumLock State</td><td>OnOff</td><td>Select the keyboard NumLock state</td></tr><tr><td>Quiet Boot</td><td>EnabledDisabled</td><td>Enables or disables Quiet Boot option</td></tr><tr><td>Fast Boot</td><td>DisableEnable</td><td>Enables or disables boot with initialization of a minimal set of devices required to launch active boot option. Has no effect for BBS boot options.</td></tr><tr><td>Boot Option #1 ~ #9</td><td>#1: Hard Disk#2: CD/DVD#3: SD#4: USB Hard Disk#5: USB CD/DVD#6: USB Key#7: USB Floppy#8: USB LAN#9: Network</td><td>For boot priority setting.</td></tr><tr><td>XXXX Drive BBS Priorities</td><td>Sub-Menu</td><td>When the bootable device is attached to system and found by BIOS, it will be listed at boot option#. If there are many devices with the same device type found, it can set priority among these devices through this sub-menu.</td></tr></table>

# 7.7 Save & Exit Menu

<table><tr><td colspan="2">Aptio Setup - AMI</td></tr><tr><td colspan="2">Main Advanced Chipset Security Boot Save &amp; Exit Server Mgmt</td></tr><tr><td rowspan="2">Save Changes and Exit
Discard Changes and Exit
Save Changes and Reset
Discard Changes and Reset
Save Options
Save Changes
Discard Changes
Restore Defaults
Save as User Defaults
Restore User Defaults
Boot Override
UEFI: JetFlashTranscend 32GB 1100, Partition 1 (JetFlashTranscend 32GB 1100)
UEFI: Built-in EFI Shell
Launch EFI Shell from filesystem device</td><td>Exit system setup after saving the changes.</td></tr><tr><td>+: Select Screen
↑↓: Select Item
Enter: Select
+/-: Change Opt.
F1: General Help
F8: Previous Values
F9: Optimized Defaults
F10: Save &amp; Exit
ESC: Exit</td></tr><tr><td colspan="2">Version 2.22.1294 Copyright (C) 2025 AMI</td></tr></table>

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>Save Changes and Exit</td><td>Enter</td><td>Save changed settings and exit BIOS setup utility.</td></tr><tr><td>Discard Changes and Exit</td><td>Enter</td><td>Skip changed setting and exit BIOS setup utility.</td></tr><tr><td>Save Changes and Reset</td><td>Enter</td><td>Save all changed settings and let system do reset to boot system.</td></tr><tr><td>Discard Changes and Reset</td><td>Enter</td><td>Discard all changed settings and let system do reset to boot system.</td></tr><tr><td>Save Changes</td><td>Enter</td><td>Save all changed settings.</td></tr><tr><td>Discard Changes</td><td>Enter</td><td>Discard changes done so far to any of the setup options.</td></tr><tr><td>Restore Default</td><td>Enter</td><td>Load the default made when BIOS was built.</td></tr><tr><td>Save as User Default</td><td>Enter</td><td>Save all changed done so far as User Defaults.</td></tr><tr><td>Restore User Default</td><td>Enter</td><td>Load the default that user save as user defaults.</td></tr><tr><td>Boot Override</td><td>Info-only</td><td></td></tr><tr><td></td><td></td><td></td></tr></table>

# 7.8 Server Management

![Aptio Setup - AMI\nMain Advanced Chipset Security Boot Save & Exit Server Mgmt\nBMC Self Test Status PASSED\nBMC Device ID 32\nBMC Device Revision 81\nBMC Firmware Revision 0.02.2\nIPMI Version 2.0\nIPMI BMC Interface KCS\nBMC Support (Enabled)\nIPMI Interface Type (Kcs Interface)\nWait For BMC (Disabled)\nWait For Full BMC Initialization (Disabled)\nFRB-2 Timer (Enabled)\nFRB-2 Timer timeout 6\nFRB-2 Timer Policy (Do Nothing)\nOS Watchdog Timer (Disabled)\nOS Wtd Timer Timeout 10\nOS Wtd Timer Policy (Reset)\nBMC Configured Power\nControl Policy Power Restore\nPower Control Policy (Unspecified)\n► System Event Log\n► Bmc self test log\nEnable/Disable interfaces to communicate with BMC\n++: Select Screen\n↑↓: Select Item\nEnter: Select\n+/-: Change Opt.\nF1: General Help\nF8: Previous Values\nF9: Optimized Defaults\nF10: Save & Exit\nESC: Exit\nVersion 2.22.1294 Copyright (C) 2026 AMI](.axe-7420gwa-50m-22811-1000-02/af35e7fd9370f39d5362b23a64895d3d1fbeb2f9d7dea03f9968289335ff7732.jpg)

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>BMC Support</td><td>EnabledDisabled</td><td>Enable/Disable interfaces to communicate with BMC.</td></tr><tr><td>IPMI Interface Type</td><td>Kcs Interface</td><td>Type of Interface to communicate BMC from HOST.</td></tr><tr><td>Wait For BMC</td><td>EnabledDisabled</td><td>Wait for BMC response for specified time out. In PILOT II, BMC starts at the same time when BIOS starts during AC power ON. It takes around 30 seconds to initialize HOST to BMC interfaces.</td></tr><tr><td>Wait For Full BMC Initialization</td><td>EnabledDisabled</td><td>Based on above rules, additional provide user can manually increase the waiting time on different platforms if necessary.</td></tr><tr><td>FRB-2 Timer</td><td>EnabledDisabled</td><td>Enable/Disable Fault Resilient Boot level 2 timer in POST stage.</td></tr><tr><td>FRB-2 Timer timeout</td><td>6</td><td>Enter value between 1 to 30 min for FRB-2 timer expiration.</td></tr><tr><td>FRB-2 Timer Policy</td><td>Do NothingResetPower DownPower Cycle</td><td>Configure how the system should respond if the FRB-2 timer expires. Not available if FRB-2 timer is disabled.</td></tr><tr><td>OS Watchdog Timer</td><td>EnabledDisabled</td><td>If enabled, starts a BIOS timer which can only be shut off by Management Software after the OS loads. Helps determine that the OS successfully loaded or follows the OS Boot Watchdog Timer policy.</td></tr><tr><td>OS Wtd Timer Timeout</td><td>10</td><td>Enter the value between 1 to 30 min for OS Boot Watchdog Timer expiration. Not available if OS Boot Watchdog Timer is disabled.</td></tr><tr><td>OS Wtd Timer Policy</td><td>Do NothingResetPower DownPower Cycle</td><td>Configure how the system should respond if the OS Boot Watchdog Timer expires. Not available if OS Boot Watchdog Timer is disabled.</td></tr><tr><td>BMC Configured Power Control Policy</td><td>Power Restore</td><td></td></tr><tr><td>Power Control Policy</td><td>Do Not Power UpLast Power StatePower RestoreUnspecified</td><td>Configure how the system should respond if AC power is lost, reset not required as selected power policy will be set in BMC when policy is saved.</td></tr></table>

# System Event Log

<table><tr><td colspan="2">Aptio Setup - AMI
Server Mgmt</td></tr><tr><td>Enabling/Disabling Options
SEL Components [Enabled]</td><td rowspan="4">Change this to enable or
disable event logging for
error/progress codes during
boot.</td></tr><tr><td>Erasing Settings
Erase SEL [No]
When SEL is Full [Do Nothing]</td></tr><tr><td>Custom EFI Logging Options
Log EFI Status Codes [Error code]</td></tr><tr><td>NOTE: All values changed here do not take
effect until computer is restarted.</td></tr><tr><td></td><td>+: Select Screen
↑↓: Select Item
Enter: Select
+/-: Change Opt.
F1: General Help
F8: Previous Values
F9: Optimized Defaults
F10: Save &amp; Exit
ESC: Exit</td></tr><tr><td colspan="2">Version 2.22.1294 Copyright (C) 2026 AMI</td></tr></table>

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>SEL Components</td><td>EnabledDisabled</td><td>Enable/Disable event logging for error/progress codes during boot.</td></tr><tr><td>Erase SEL</td><td>NoYes, on next resetYes, on every reset</td><td>Choose options for erasing SEL.</td></tr><tr><td>When SEL is Full</td><td>Do NothingErase ImmediatelyDelete Oldest Record</td><td>Choose options for reactions to a full SEL.</td></tr><tr><td>Log EFI Status Codes</td><td>DisabledBothError code</td><td>Choose options for logging EFI Status Codes.</td></tr><tr><td></td><td>Progress code</td><td></td></tr></table>

# BMC Self Test Log

![Aptio Setup - AMI\nServer Mgmt\nLog area usage = 00 out of 20 logs\nErase Log (Yes, On every reset)\nWhen log is full (Clear Log)\nLog Empty\nErase Log Options\n+: Select Screen\n↑↓: Select Item\nEnter: Select\n+/-: Change Opt.\nF1: General Help\nF8: Previous Values\nF9: Optimized Defaults\nF10: Save & Exit\nESC: Exit\nVersion 2.22.1294 Copyright (C) 2026 AMI](.axe-7420gwa-50m-22811-1000-02/cca22020ffd0a5a8d9c3457a280fb95f84e3b9e37d0e27fb7449451e06d52563.jpg)

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>Erase Log</td><td>Yes, on every resetNo</td><td>Choose options for erasing logs.</td></tr><tr><td>When log is full</td><td>Clear LogDo not log any more</td><td>Choose options for reactions to a full log.</td></tr></table>

# BMC Network Configuration

![Aptio Setup - AMI\nServer Mgmt\n--BMC network configuration--\n*****************\nConfigure IPv4 support\n*****************\nLan channel 1\nConfiguration Address source (Unspecified)\nCurrent Configuration Address staticAddress\nsource\nStation IP address 192.168.1.1\nSubnet mask 255.255.255.0\nStation MAC address 82-E2-BB-69-71-90\nRouter IP address 0.0.0.0\nRouter MAC address 00-00-00-00-00-00\n*****************\nConfigure IPv6 support\n*****************\nLan channel 1\nIPv6 Support (Enabled)\nConfiguration Address source (Unspecified)\nSelect to configure LAN\nchannel parameters statically\nor dynamically(by BIOS or\nBMC). Unspecified option will\nnot modify any BMC network\nparameters during BIOS phase\n+: Select Screen\n↑↓: Select Item\nEnter: Select\n+/-: Change Opt.\nF1: General Help\nF8: Previous Values\nF9: Optimized Defaults\nF10: Save & Exit\nESC: Exit\nVersion 2.22.1294 Copyright (C) 2026 AMI](.axe-7420gwa-50m-22811-1000-02/5037c890bf8bdd84dd3ff6860e94d825e5ed30ecc4a06f85f019968b4490ee32.jpg)

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>IPv4Configuration Address source</td><td>UnspecifiedStaticDynamicBmcDhcpDynamicBmcNonDhcp</td><td>Select to configure LAN channel parameters statically or dynamically (by BIOS or BMC). Unspecified option will not modify any BMC network parameters during BIOS phase.</td></tr><tr><td>IPv6 Support</td><td>EnabledDisabled</td><td>Enable/Disable LAN1 IPv6 Support</td></tr><tr><td>IPv6Configuration Address source</td><td>UnspecifiedStaticDynamicBmcDhcpDynamicBmcNonDhcp</td><td>Select to configure LAN channel parameters statically or dynamically (by BIOS or BMC). Unspecified option will not modify any BMC network parameters during BIOS phase.</td></tr><tr><td>IPv6Configuration Router Lan1 Address source</td><td>UnspecifiedStaticDynamicBmcDhcp</td><td>Select to configure LAN channel parameters statically or dynamically (by BIOS or BMC). Unspecified option will not modify any BMC network parameters during BIOS phase</td></tr><tr><td>VLAN Support</td><td>EnabledDisabledUnspecified</td><td>Enable VLAN Support to specify the 802.1q VLAN ID</td></tr></table>

# 7.9 View System Event Log

![Aptio Setup - AMI\nMain Advanced Chipset Security Boot Save & Exit Server Mgmt\nIPMI Version 2.0\nIPMI BMC Interface KCS\nBMC Support (Enabled)\nIPMI Interface Type (Kcs Interface)\nWait For BMC (Disabled)\nWait For Full BMC Initialization (Disabled)\nFRB-2 Timer (Enabled)\nFRB-2 Timer timeout View System Event Log\nFRB-2 Timer Policy\nOS Watchdog Timer Retrieving all system events will take time. Do you want to continue?\nOS Wtd Timer Timeout\nOS Wtd Timer Policy\nBMC Configured Power Yes No\nControl Policy Select\nPower Control Policy\nSystem Event Log\nBmc self test log\nBMC network configuration\nView System Event Log\nBMC User Settings\nBMC Warm Reset\nPress (Enter) to view the System Event Log Records.\nF1: General Help\nF8: Previous Values\nF9: Optimized Defaults\nF10: Save & Exit\nESC: Exit\nVersion 2.22.1294 Copyright (C) 2026 AMI](.axe-7420gwa-50m-22811-1000-02/c7ffc1d8bb29b466857449ed00d2d587e8ead0b6eb130e339ae0f4ab1766f291.jpg)

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>View System Event Log</td><td>YesNo</td><td>Retrieving all system events will take time. Do you want to continue?</td></tr></table>

# 7.10 BMC User Settings

![Aptio Setup - AMI\nServer Mgmt\nBMC User Settings\n► Add User\n► Delete User\n► Change User Settings\nPress (Enter) to Add a User.\n+: Select Screen\n↑↓: Select Item\nEnter: Select\n+/-: Change Opt.\nF1: General Help\nF8: Previous Values\nF9: Optimized Defaults\nF10: Save & Exit\nESC: Exit\nVersion 2.22.1294 Copyright (C) 2026 AMI](.axe-7420gwa-50m-22811-1000-02/f3bd542c84758bf6d93b95916f25895cab13c5ea19cafc3b12c5f93f9a1dbfd3.jpg)

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>Add User</td><td>Enter</td><td>Press &lt;Enter&gt; to Add a User.</td></tr><tr><td>Delete User</td><td>Enter</td><td>Press &lt;Enter&gt; to Delete a User.</td></tr><tr><td>Change User Settings</td><td>Enter</td><td>Press &lt;Enter&gt; to Change User Settings.</td></tr></table>

# 7.11 BMC Warm Reset

![Aptio Setup - AMI\nMain Advanced Chipset Security Boot Save & Exit Server Mgmt\nIPMI Version 2.0\nIPMI BMC Interface KCS\nBMC Support (Enabled)\nIPMI Interface Type (Kcs Interface)\nWait For BMC (Disabled)\nWait For Full BMC Initialization (Disabled)\nFRB-2 Timer (Enabled)\nFRB-2 Timer timeout 6\nFRB-2 Timer Policy (Do Nothing)\nOS Watchdog Timer (Disabled)\nOS Wtd Timer Timeout 10\nOS Wtd Timer Policy (Reset)\nBMC Configured Power\nControl Policy Power Restore\nPower Control Policy (Unspecified)\n► System Event Log\n► Bmc self test log\n► BMC network configuration\n► View System Event Log\n► BMC User Settings\nBMC Warm Reset\nPress (Enter) to do Warm Reset\nBMC.\n◆: Select Screen\n↑↓: Select Item\nEnter: Select\n+/-: Change Opt.\nF1: General Help\nF8: Previous Values\nF9: Optimized Defaults\nF10: Save & Exit\nESC: Exit\nVersion 2.22.1294 Copyright (C) 2026 AMI](.axe-7420gwa-50m-22811-1000-02/eae1f288ea30d86d6d808cab52760f82b8d4f3758507b3e5ecb4c3f2a6e525f6.jpg)

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>BMC Warm Reset</td><td>Enter</td><td>Press &lt;Enter&gt; to do Warm Reset BMC.</td></tr></table>

# BMC

This chapter provides detailed information on understanding, configuring, and managing the BMC.

<table><tr><td>Abbreviation</td><td>Description</td></tr><tr><td>BMC</td><td>Baseboard management controller</td></tr><tr><td>CLI</td><td>Command line interface</td></tr><tr><td>FRU</td><td>Field replaceable unit</td></tr><tr><td>GUI</td><td>Graphical user interface</td></tr><tr><td>IPMI</td><td>Intelligent platform management interface</td></tr><tr><td>IPU</td><td>Intelligence Processing Unit</td></tr><tr><td>NTP</td><td>Network time protocol</td></tr><tr><td>PSU</td><td>Power supply unit</td></tr><tr><td>SDR</td><td>Sensor data record</td></tr><tr><td>SEL</td><td>System event log</td></tr><tr><td>SNMP</td><td>Simple network management protocol</td></tr><tr><td>SoL</td><td>Serial over LAN</td></tr></table>

# 8.1 BMC Introduction

# Software Interface

BMC (Baseboard Management Controller) is equipped with a multitude of interfaces, each designed to cater to different aspects of server management and monitoring. These interfaces provide comprehensive control and insight, ensuring administrators can effectively oversee server operations.

# Web GUI

The product supports Web GUI access through HTTPS (port 443), with HTTP disabled by default for enhanced security. The Web GUI offers a management interface, enabling users to view system information, system events, and status, as well as to control the managed servers.

# IPMI Interface

The IPMI (Intelligent Platform Management Interface) is a standardized interface used for remote monitoring and management of server systems. It provides a powerful set of tools for system administrators to control and monitor servers independently of the operating system.

# Features of IPMI

Event Logging: Critical system events and hardware status changes are logged, facilitating efficient troubleshooting.

Security: IPMI supports secure interfaces and protocols for safe remote management.

# Redfish

Redfish is a modern, RESTful API used for the management of servers, storage, and networking equipment in data centers and large-scale enterprise environments. It's designed to replace older, less efficient management interfaces with a standardized, scalable, and secure approach.

# 8.2 Web GUI Introduction

The Web GUI of BMC is a critical component that offers an intuitive and user-friendly platform for managing and monitoring server operations remotely. This web-based interface ensures administrators can efficiently interact with the server’s BMC from anywhere.

# Web Login

Web login to the BMC interface is a straightforward process designed to provide secure and easy access to server management tools.

# Environment Setup

Before logging into the BMC's Web GUI, certain environmental prerequisites must be met:

 Network Configuration

Ensure the server and the device used for access are on the same network or have a route to connect.

 Browser Requirements:

Verify that the web browser used is compatible with the BMC's Web GUI. Commonly supported browsers include Chrome, Firefox, Safari, and Edge.

 BMC IP Address

You can setup the BMC IP address from the server’s BIOS interface or ipmitool command listed in the section 5.3 BMC LAN Configuration. To setup from BIOS interface, navigate to the "Server Mgmt" tab and select the "BMC network configuration" option.

![Aptio Setup - AMI\nServer Mgmt\n--BMC network configuration--\n******************\nConfigure IPv4 support\n******************\nLan channel 1\nConfiguration Address (Unspecified)\nCurrent Configuration DynamicAddressBmcDhcp\nStation IP address 0.0.0.0\nSubnet mask 0.0.0.0\nStation MAC address 00-30-64-66-77-88\nRouter IP address 0.0.0.0\nRouter MAC address 00-00-00-00-00-00\nLan channel 2\nConfiguration Address (Unspecified)\nCurrent Configuration DynamicAddressBmcDhcp\nStation IP address 172.20.2.12\nSelect to configure LAN\nchannel parameters\nstatically or\ndynamically(by BIOS or\nBMC). Unspecified\noption will not modify\nany BMC network\nparameters during BIOS\n+: Select Screen\n↑↓: Select Item\nEnter: Select\n+/-: Change Opt.\nF1: General Help\nF8: Previous Values\nF9: Optimized Defaults\nF10: Save & Exit\nESC: Exit\nVersion 2.22.1289 Copyright (C) 2024 AMI\nAB](.axe-7420gwa-50m-22811-1000-02/c7105e652120ba8bf53ce32bfff56ff889b7f01e45008716f83ba8f37141089b.jpg)

 Security Considerations

For security reasons, access to the BMC Web GUI is exclusively through HTTPS.

# User Sign-In

#  Accessing the Login Page

Open your web browser and type in the BMC's IP address, obtained from the BIOS, preceded by "https://". For example, https://[BMC-IP-Address].

This action will direct you to the BMC Web GUI login page.

![ISB-W890 BMC\nUsername\nPassword\nUS - English\nRemember Username\nSign me in\nI forgot my password](.axe-7420gwa-50m-22811-1000-02/3a6163146e7a92f0386dcaef9773b7f54ac129c8582737356f30f938fc5b2c81.jpg)

#  Selecting Language

Below the login fields, there is an option to select your preferred language.

The BMC Web GUI supports multiple languages, including Simplified Chinese, Traditional Chinese, and English.

Choose your desired language from the dropdown menu before logging in.

#  Entering Login Credentials

On the login page, you will be prompted to enter your username and password.

The default username: admin

The default password: admin

After entering these credentials, click the "Sign me in" button to proceed.

#  Other fields

Remember Username: Check this option to remember your login Username. If you select this option, the browser will save your credentials internally in its memory, and when you open that site the next time, it will auto-fill Username for you.

I Forgot my Password: If you forget your password, you can generate a new password using this link.

# Web Interface Overview

This section provides an overview of the BMC's Web Interface, emphasizing the functionalities and information displayed on the main interface. The primary purpose of the main interface is to offer a quick and comprehensive understanding of the current status of the BMC.

![ADLINK\nISB-W890 BMC\nFirmware Information\n1.04.0\nJun 12 2026 09:36:18 CST\nHost Online\nQuick Links..\nDashboard Control Panel\n0 d 0 hrs\nPower-On Hours\n4\nAccess Logs\nMore info\nHome ) Dashboard\nSensors\nSystem Inventory\nFRU Information\nLogs & Reports\nSettings\nRemote Control\nImage Redirection\nPower Control\nMaintenance\nSign out](.axe-7420gwa-50m-22811-1000-02/5305c6d37171a6167a4449f0691d2b141403c23bb0ab44fd09feb10b1a314cd4.jpg)

The BMC Web GUI is primarily divided into three sections, each offering specific functionalities and information crucial for server management.

# 1. Top Menu Bar

Functionality: The top menu bar is designed for receiving and viewing server messages, setting BMC global configurations, and accessing the BIOS configuration interface. This area serves as a quick access point for important notifications and system adjustments.

<table><tr><td>Function</td><td>Icon</td><td>Detailed Description</td></tr><tr><td>Message</td><td>&lt;img src="images/064540a0c795d2ba40e99dd3c57a0e1d1b6adfbff1ec09ba1bd88e4436a29e79.jpg"/&gt;</td><td>Display the messages received.</td></tr><tr><td>Notification</td><td>&lt;img src="images/df821db6aecddae8e6ed3eeacf3bd03d5c2af38d6fe9d43a921ea2320315d2d0.jpg"/&gt;</td><td>Display the notifications received.</td></tr><tr><td>Language</td><td>&lt;img src="images/1082baba26c5a6cd401c648456465dca41cbf6f267ae49766fe319c09adc893d.jpg"/&gt;</td><td>Set Board Language.</td></tr><tr><td>Bios interface</td><td>&lt;img src="images/2bc7905fc7d4b1e874c1da0056477c2ac18409df973cef9355ee82d90099e250.jpg"/&gt;</td><td>Open the new window or popup to configure the BIOS settings.</td></tr><tr><td>Dashboard Expansion</td><td>&lt;img src="images/49d64d03115d141560f10daa63ba1f404ff1e5c5dc82ce850be82ab2ec56d332.jpg"/&gt;</td><td>Show/Hide limited Dashboard Widgets.</td></tr><tr><td>2FA</td><td>&lt;img src="images/6c5cc5cbe3292d5e7bdfb49c830d9513facf217680c34d982ccd70b7c17340ec.jpg"/&gt;</td><td>Enable/Disable Two Factor Authentication.</td></tr><tr><td>Synchronization</td><td>&lt;img src="images/38418b5e38b76505e770b3aae53cc979681a70a7d1f420d6ac2b815ce26e6889.jpg"/&gt;</td><td>On/Off to synchronize with latest Sensor and Event Log updates.</td></tr><tr><td>Refresh</td><td>&lt;img src="images/aca3fd1c4ced604203ba3800f26d237720e1776dd31a65573fe2937272a1a522.jpg"/&gt;</td><td>Reload the current page.</td></tr><tr><td>Profile</td><td>&lt;img src="images/edd06bbd7d651377bf54d0f9e86061a3419b3b9ab54c8796ffa40e153441fc6a.jpg"/&gt; [5X4T]</td><td>Set the User Profile.</td></tr></table>

# 2. Server Version Information

This section of the interface displays the current version information of various server components, listed in the following order:

![MegaRAC SP-X\nFirmware Information\n1.02.100\nJan 5 2026 12:03:34 CST\n● Host Offline](.axe-7420gwa-50m-22811-1000-02/63f95caff8dc495e9b607d20096dd5c82a70849780454ea4f603a7924ee7d5fb.jpg)

BMC Version Information
BMC Image Build Date and Time
Chassis Power Status

The version information window provides a quick overview of the server's hardware and firmware status, ensuring that administrators are immediately aware of the current versions and operational status.

The Chassis Power Status will be displayed as Host Online / Host Offline. To Change the Power Control Status, click Host Online / Host Offline link.

# 3. Function Menu bar

The menu bar displays the following.

 Dashboard
 Sensor
 System Inventory
 FRU Information
 Logs & Reports
 Settings
 Remote Control
 Image Redirection
 Power Control
 Maintenance
 Sign out

# Server Information

# FRU Information

![The image shows a small rectangular dropdown menu box containing the number '0' on the left side and a downward-pointing triangle arrow on the right side.](.axe-7420gwa-50m-22811-1000-02/74ed393ed0d99c71325604f512010e67db3eb6a380b5aa4f30c9b761686063d4.jpg)

FRU Device Name

BMC\_FRU

Chassis Information

<table><tr><td>Chassis Information Area Format Version</td><td>1</td></tr><tr><td>Chassis Type</td><td>Unspecified</td></tr><tr><td>Chassis Part Number</td><td>91-XXXX-XXX</td></tr><tr><td>Chassis Serial Number</td><td>0000000000000000000</td></tr></table>

Chassis Extra

Board Information

<table><tr><td>Board Information Area Format Version</td><td>1</td></tr><tr><td>Language</td><td>English</td></tr><tr><td>Manufacture Date Time</td><td>Fri Nov 17 19:33:00 2023</td></tr><tr><td>Board Manufacturer</td><td>ADLINK Technology</td></tr><tr><td>Board Product Name</td><td>MECS-7120</td></tr><tr><td>Board Serial Number</td><td>0000000000000000000</td></tr><tr><td>Board Part Number</td><td>91-XXXX-XXX</td></tr><tr><td>FRU File ID</td><td></td></tr><tr><td>Board Extra</td><td></td></tr></table>

Product Information

<table><tr><td>Product Information Area Format Version</td><td>1</td></tr><tr><td>Language</td><td>English</td></tr><tr><td>Product Manufacturer</td><td>ADLINK Technology</td></tr><tr><td>Product Name</td><td>MECS-7120</td></tr><tr><td>Product Part Number</td><td>91-XXXXX-XXX</td></tr><tr><td>Product Version</td><td>1</td></tr><tr><td>Product Serial Number</td><td>0000000000000000000</td></tr><tr><td>Asset Tag</td><td>TEST</td></tr><tr><td>FRU File ID</td><td></td></tr><tr><td>Product Extra</td><td></td></tr></table>

The FRU (Field Replaceable Unit) Information interface in the BMC Web GUI is accessed by clicking on the "FRU Information" option in the left-hand function bar. This feature allows users to view electronic label information for the motherboard and other components, providing detailed FRU data.

Structure and Functionality of the FRU Information Interface. The FRU information is divided into four main sections, each offering specific insights:

<table><tr><td>Information Category</td><td>Description</td></tr><tr><td>Available FRU Devices</td><td>Details about each FRU device:FRU Device IDFRU Device Name</td></tr><tr><td>Chassis Information</td><td>Information related to the server's chassis, featuring:Chassis Information Area Format VersionChassis TypeChassis Part NumberChassis Serial NumberChassis Extra</td></tr><tr><td>Board Information</td><td>Data about the server's mainboard, encompassing:Board Information Area Format VersionLanguageManufacture Date TimeBoard ManufacturerBoard Product NameBoard Serial NumberBoard Part NumberFRU File IDBoard Extra</td></tr><tr><td>Product Information</td><td>Comprehensive details about the product, including:Product Information Area Format VersionLanguageProduct ManufacturerProduct NameProduct Part NumberProduct VersionProduct Serial NumberAsset TagFRU File IDProduct Extra</td></tr></table>

# Sensor Information

The Sensor Information panel in the BMC Web GUI provides a detailed overview of the current status and readings from various sensors within the server. Accessing and understanding this data is essential for maintaining the server's health and performance.

Accessing the Sensor Information Panel
Navigating to the Panel
Click on the "Sensor" button located on the left side of the BMC Web GUI

# 8.2.3.2.1 Introduction to Sensor Interface

This will lead you to the Sensor Information interface, which is central for real-time sensor status monitoring.

# Sensor Information Interface Layout

The Sensor Information interface is divided into four distinct sections, each providing specific types of sensor data:

# 1. Critical Sensors

This section displays the status of critical sensors, highlighting if any sensor has exceeded its threshold or is showing abnormal readings.

It's a focal point for quickly identifying potential issues that require immediate attention.

# 2. Discrete Sensor States

QDiscrete Sensor States (12)

<table><tr><td>Sensor Name</td><td>State</td></tr><tr><td>ACPI_Power</td><td>S0/G0 &#x27;Working</td></tr><tr><td>FAN1_Presence</td><td>Device Inserted / Device Present</td></tr><tr><td>FAN2_Presence</td><td>Device Inserted / Device Present</td></tr><tr><td>FAN3_Presence</td><td>Device Inserted / Device Present</td></tr><tr><td>FAN4_Presence</td><td>Device Inserted / Device Present</td></tr><tr><td>FAN5_Presence</td><td>Device Inserted / Device Present</td></tr><tr><td>HDD1_Status</td><td>Drive Presence</td></tr><tr><td>HDD2_Status</td><td>Drive Absence</td></tr><tr><td>PSU1_Presence</td><td>Device Inserted / Device Present</td></tr><tr><td>PSU1_Status</td><td>Presence Detected, Power Supply Failure Detected, Power Supply Input Lost (AC/DC)</td></tr><tr><td>PSU2_Presence</td><td>Device Inserted / Device Present</td></tr><tr><td>PSU2_Status</td><td>Presence Detected</td></tr></table>

Shows the status of discrete sensors, particularly focusing on those that are offline.

This part is crucial for identifying sensors that are not functioning or are disconnected.

# 3. Normal Sensors

Normal Sensors (46)

<table><tr><td>Sensor Name</td><td>Reading</td><td>Behavior</td></tr><tr><td>↓ CPU_Outlet_Temp</td><td>28 °C</td><td></td></tr><tr><td>○ CPU_Power</td><td>34 Watts</td><td></td></tr><tr><td>↓ CPU_TJMAX</td><td>99 °C</td><td></td></tr><tr><td>↓ CPU_Temp</td><td>31 °C</td><td></td></tr><tr><td>↓ DIMM_A1_Temp</td><td>23 °C</td><td></td></tr><tr><td>♣ FAN1_Speed_Inner</td><td>7050 Rpm</td><td></td></tr><tr><td>♣ FAN1_Speed_Outer</td><td>6000 Rpm</td><td></td></tr><tr><td>♣ FAN2_Speed_Inner</td><td>7050 Rpm</td><td></td></tr><tr><td>♣ FAN2_Speed_Outer</td><td>6000 Rpm</td><td></td></tr><tr><td>♣ FAN3_Speed_Inner</td><td>7050 Rpm</td><td></td></tr><tr><td>♣ FAN3_Speed_Outer</td><td>6000 Rpm</td><td></td></tr><tr><td>♣ FAN4_Speed</td><td>6750 Rpm</td><td></td></tr></table>

Displays the actual readings from various sensors.

These readings include data such as temperature, fan speeds, voltage levels, and more.

The section provides a comprehensive view of the real-time operating conditions of the server.

# 4. Disabled Sensors

Q Disabled Sensors (16)

<table><tr><td>×DIMM_B1_Temp</td><td>×DIMM_C1_Temp</td><td>×DIMM_E1_Temp</td><td>×DIMM_G1_Temp</td></tr><tr><td>×DIMM_H1_Temp</td><td>×PSU2_Inlet_Temp</td><td>×PSU2_Sec_Temp</td><td>×PSU2_Prm_Temp</td></tr><tr><td>×TBF100_Up_Temp</td><td>×TBF100_Down_Temp</td><td>×PSU2_VOUT</td><td>×PSU2_POUT</td></tr><tr><td>×PSU2_PIN</td><td>×PSU2_Status</td><td>×TBF100_Up_PWR</td><td>×TBF100_Down_PWR</td></tr></table>

Lists sensors that are currently not in operation or are disabled.

This section helps in identifying which sensors are not contributing to the monitoring process and may need reactivation or maintenance.

# 8.2.3.2.2 Detailed Sensor Information

Accessing and Viewing Sensor Details. To view detailed information about a specific sensor, simply click on the desired sensor listed in the Sensor Information panel. This action will lead you to a dedicated detail page for that sensor.

On this detailed page, extensive information about the selected sensor is displayed, including its current operational status, various parameters, and any unique specifications.

![Sensor detail All information about this sensor\nACPI_Power Sensor Information\nSensor State Reading - 0x8001\nACPI_Power Sensor Events\nJanuary 2024\nID: 48 ACPI_Power sensor of type System ACPI Power State logged a s5 or g2 soft off 3 days ago\nID: 36 ACPI_Power sensor of type System ACPI Power State logged a s0 or g0 working 3 days ago\nID: 34 ACPI_Power sensor of type System ACPI Power State logged a s5 or g2 soft off 3 days ago\nID: 18 ACPI_Power sensor of type System ACPI Power State logged a s0 or g0 working 3 days ago\nID: 16 ACPI_Power sensor of type System ACPI Power State logged a s5 or g2 soft off 3 days ago\nID: 12 ACPI_Power sensor of type System ACPI Power State logged a s0 or g0 working 3 days ago](.axe-7420gwa-50m-22811-1000-02/1ed447190d22e0259fe57d82662c5ea7f9a51da9ff7b471c29442282b910b9dd.jpg)

# Customizing Sensor Thresholds:

For general sensors, the detailed interface provides the capability to adjust various sensor threshold parameters. Administrators have the flexibility to modify several threshold levels including:

Upper Non-Recoverable

Upper Critical

Upper Non-Critical

Lower Non-Critical

Lower Critical

Lower Non-Recoverable

# Practical Application:

Adjusting these thresholds is vital for preemptive alerts and ensuring that sensors are operating within safe and optimal ranges.

![A light green circular icon featuring a white question mark in the center, set against a white background.](.axe-7420gwa-50m-22811-1000-02/fd4ae11a0306957597dacee73609e8c64d08601383d0ffb72759ecaba0564d94.jpg)

QPOV8\_E810 Sensor Information
![| Time (HH:MM:SS) | Volts |\n| --------------- | ----- |\n| 14:51:20        | 0.83  |\n| 14:51:41        | 0.79  |\n| 14:52:45        | 0.82  |\n| 14:53:06        | 0.79  |\n| 14:53:26        | 0.82  |\n| 14:53:47        | 0.79  |\n| 14:00:00        | 0.83  |](.axe-7420gwa-50m-22811-1000-02/8462c4fd765229259e34095eb2b689f5db4a6111a0951b1fa4faedbe689188ab.jpg)

0.81Volts

<table><tr><td>Upper Non-Recoverable</td><td>0.88 Volts</td></tr><tr><td>Upper Critical</td><td>NA</td></tr><tr><td>Upper Non-Critical</td><td>NA</td></tr><tr><td>Lower Non-Critical</td><td>0.76 Volts</td></tr><tr><td>Lower Critical</td><td>0.74 Volts</td></tr><tr><td>Lower Non-Recoverable</td><td>0.72 Volts</td></tr></table>

Change Thresholds

If the synchronization button in the top menu bar is active, accessing the detail interface for a general sensor will enable a graphing feature. This feature provides a line graph depicting the sensor’s data over time. It serves as a visual tool for quickly assessing the sensor’s performance.

# 8.2.3.2.3 Modifying Sensor Thresholds

Accessing Sensor Thresholds Modification Interface. In the Sensor Details interface, locate and click on the "Change Thresholds" button. This action will redirect you to the Sensor Thresholds interface.

# Sensor Thresholds

# Change Threshold Values

![The image displays two identical light green circular icons arranged side-by-side on a white background. Inside each green circle is a white question mark.](.axe-7420gwa-50m-22811-1000-02/83f82ee2831f16b6cbc04f70806acef646373e13b2a02cae77714dca5eb56750.jpg)

#

# Sensor Name

# Upper Non-recoverable

13.20

# Upper Critical

12.84

# Upper Non-critical

12.60

# Lower Non-critical

11.40

# Lower Critical

11.16

# Lower Non-recoverable

10.80

# Retain Threshold Values

![The image displays a solid blue background featuring a white, pixelated graphic in the center. The graphic appears to be a stylized letter 'E' or a simplified document icon, characterized by a blocky white shape containing two dark, rectangular areas within it. The image is low-resolution and blurry.](.axe-7420gwa-50m-22811-1000-02/c8354bd617dd2720f2c2b7696d9af6d302b550be24ed328ea116f15a9ce48921.jpg)

Save

# Sensor Thresholds Interface:

The Sensor Thresholds interface displays each sensor's name along with its threshold values.
Users can view and modify thresholds for each sensor, including upper and lower warning and critical limits.
Thresholds not applicable or unavailable for a sensor are marked as "NA".

# Retaining Threshold Values

At the bottom of the interface, a "Retain Threshold Values" checkbox is provided.

Note: If this option is not selected, threshold adjustments will be temporary, reverting to default upon BMC reboot or power loss.

# Server Information

BMC provides various logging functions that are crucial for system diagnosis, monitoring, and security. Logs are divided into different types, each with a specific purpose.

Accessing BMC Logs

To view these logs, navigate to the BMC web interface:

From the left-side functional panel, click on "Logs & Reports".
A dropdown menu will appear, listing the following types of logs available for viewing:

![Logs & Reports\n» IPMI Event Log\n» System Log\n» Audit Log\n» Video Log\n» SOL Video Log](.axe-7420gwa-50m-22811-1000-02/3d818adc8692bc6269c0167b1abfac896cedc7bbdf9c2eb9568b605c1642a1cb.jpg)

 IPMI Event Log
 System Log
 Audit Log
 Video Log
 SOL Video Log

# IPMI Event Log

This page displays the list of event logs occurred by the different sensors on this device. Double click on a record to see the details of that entry. You can use the sensor type or sensor name filter options to view those specific events or you can also sort the list of entries by clicking on any of the column headers.

To open the Event Log page, click Logs & Reports > Event Log from the menu bar. A sample screenshot of Event Log page is shown below.

![| Event Log | Sensor Type | Event Log Count |\n| :--- | :--- | :--- |\n| January 2000 | All Events | 1 |\n| January 2022 | All Events | 3 |\n| January 2024 | All Events | 2 |](.axe-7420gwa-50m-22811-1000-02/9cc7709ce627f56abf155ef59f8f77c4ba5be5eb76e5fb4ead7cacf5cb4124df.jpg)

The Event Log page consists of the following fields:

Filter By Date: Filtering can be done by selecting Start Date and End Date using Calendar.

Note: Date should be in MM/DD/YYYY format. By default, all log time will be displayed in BMC time zone.

Filter By Type: The category could be either All Events, System Event Records, OEM Event Records, BIOS Generated Events, SMI Handler Events, System Management Software Events, System Software - OEM Events, Remote Console Software Events, Terminal Mode Remote Console software Events.

Note: Once the Filter By Date and Filter type are selected, the list of events will be displayed with the Event ID, Time Stamp, Sensor Type, Sensor Name and Description.

UTC Offset: Displays the current UTC Offset value based on which event Time Stamps will be updated. Navigational arrows can be used to selectively access different pages of the Event Log.

Event Log Statistics: Displays the statistical graph for the selected date.

Clear Event Logs: To delete all the event logs.

Download Event Logs: To download the event logs.

# Procedure

1. From the Filter ByDate field, select the time period by Start Date and End Date using Calendar for the event categories. The events will be displayed according to the selected date.
2. From the Filter By Type field, select the Type of the event and Sensor name to view the events for the date. The events will be displayed based on the selected time period.
3. To clear all events from the list, click Clear All Event Logs.
4. To download the event logs, click Download Event Logs.

Note: When Clear All Event Logs action is performed, there might be some events present even after clearing those events are generated after performing clear operation which can be verified using its timestamp.

# System Log

System Log page will display all the system events occurred in this device that has been already configured.

Note: Logs have to be configured under Settings > Log Settings in order to display any entries.

To open the Event Log page, click Logs & Reports > System Log from the menu bar.

![System Log All system event logs\nFilter by Date Start Date End Date Event Category Alert\nSystem Log: 1 out of 1 event entries\nJanuary 2024\nID: 1 January 22nd 2024, 6:40:12 pm AMI003064F3092B kernel: kernel -- (7.330370) Copyright (c) 2009-2015 American Megatrends Inc. -](.axe-7420gwa-50m-22811-1000-02/ef0fe86d9546b43eac869f767d4ff76c86807d5f9621ffdf3b6012aeb732c17c.jpg)

# Procedure

To view System Log, click the System Log tab to view all system events. Entries can be filtered based on Filter By Date (Start Date and End Date) and Event Category like Alert, Critical, Error, Notification, Warning, Debug, Emergency and Information.

# Audit Log

Audit Log page will display all the system events occurred in this device that has been already configured.

Note: Logs have to be configured under Settings > Log Settings > Advanced Log Settings in order to display any entries.

To open the Event Log page, click Logs & Reports > Audit Log from the menu bar.

![Audit Log All audit logs\nFilter by Date Start Date End Date\nJanuary 2024\nID: 4 January 23rd 2024, 10:03:13 am AMI003064F3092B spx_restservice: spx_restservice - (2094 : 2094 INFO)https Login from IP:172.20.2.72 user:admin -\nID: 3 January 22nd 2024, 7:13:34 pm AMI003064F3092B spx_restservice: spx_restservice - (2094 : 2094 INFO)HTTPS logout from IP:172.20.2.54 user:admin -\nID: 2 January 22nd 2024, 6:40:35 pm AMI003064F3092B login(2273): login 2273 - (2273 : 2273 INFO)SERIAL Login from IP:127.0.0.1 user:sysadmin -\nID: 1 January 22nd 2024, 6:40:25 pm AMI003064F3092B spx_restservice: spx_restservice - (2094 : 2094 INFO)https Login from IP:172.20.2.54 user:admin -](.axe-7420gwa-50m-22811-1000-02/3c0eab3945b780a87dd3c33314b8b787055d1ca5e55df98a8b256e0ccfac603c.jpg)

# Video Log

The video log page will record the configured system events in the device in a video format that has been already configured.

Note: Video Trigger Settings should be enabled, to display the Video Log page. Video Trigger Settings can be configured under Settings > Video Recording > Auto Video Settings > Video Trigger Settings.

To open the Video Log page, click Logs & Reports > Video Log from the menu bar. A sample screenshot of Video Log page is shown below

![Video Log All video event logs\nFilter by Date Start Date End Date\nVideo Log: 1 out of 1 event entries\nJanuary 2024\nvideo_dump_2024y-01m-23d_10h-55m-26s.dat Post Event Recorded on Tuesday, January 23rd 2024, 10:55:45 am\nID: 1 7 minutes ago](.axe-7420gwa-50m-22811-1000-02/9f461ceae2c9bb27678104c12ab57345f120bee86359e0cb6465f9b6d4402092.jpg)

After clicking on the video event, the video conversation box will pop up. Play the current video. In this interface, you can choose to download or delete the current video log.

![Video Log\nFilter by\nJanuary 2\nDuration 8:00\nUS - English\n2FA\nSync\nRefresh\nadmin\nHome ) Video Log\nID: 1 an hour ago](.axe-7420gwa-50m-22811-1000-02/120043b376ff61e443ea9b82bfe7a99f847a0322f41626f69efc2fa1e6b1cc15.jpg)

Note: Video will be allowed to play/download only if file size is lesser than 40MB. Browsers have various memory restrictions, due to this browser cannot store and process data greater than 40MB (approximately). If file size is greater than 40MB, user will be notified with a message to use Java player Application.

The video data may not be proper if the browser zoom in/out settings are changed during video playback.

To download a video, you need to wait for the video buffering to complete before downloading.

# SOL Video Log

The sol log page will record configured system events through sol.

Note: SOL Trigger Settings should be enabled, to display the SOL Log page. SOL Trigger Settings can be configured under Settings > Video Recording > SOL Settings > SOL Trigger Settings.

SOL Configurations can set the baud rate of the serial port.

To open the Video Log page, click Logs & Reports > SOL Log from the menu bar. A sample screenshot of SOL Log page is shown below.

![SOL Video log All SOL Video log\nS.No File Name File Information\n1 SOLHostCapture_Archive_1_01232024_13_26_08.log Tuesday, January 23rd 2024, 1:26:08 pm](.axe-7420gwa-50m-22811-1000-02/c17ff3315a6fbbf1493ef9eb8380790edac565a1052bf4eff8d3b9b5ebd39cb0.jpg)

S.No - The serial number

File Name - The video filename

File Information - Day, date, and time of video upload

Download - To download the selected video

Delete - To delete the selected video.

Note: The timestamp displayed in the file information represents last modified time, and it will be updated (if the file is modified) when the webpage is refreshed.

# Power Control

It is used to control power on the WEB. A sample screenshot of service management is shown as below.

# Power Control on Host Server

# Power Actions

![The image shows two light green circular icons positioned side-by-side. Inside each circle is a white question mark centered vertically. The background is white.](.axe-7420gwa-50m-22811-1000-02/12912ee0bad1bd961cabe15cf7caa23458c1ce7e5794876facc69876dd28f776.jpg)

#

![A horizontal row of white circles arranged against a solid black background. The circles are evenly spaced and appear to be touching or slightly overlapping, creating a chain-like effect. Four complete circles are fully visible in the center, flanked by partial circles visible on the far left and far right edges.](.axe-7420gwa-50m-22811-1000-02/588a6b25231a0045e86746a1100c30380e418c9a32e0299639bd48b49fd47239.jpg)

Power Off

![The image displays three faint, light gray concentric rings or circles arranged horizontally against a plain white background. There is no visible text.](.axe-7420gwa-50m-22811-1000-02/02384692d4343b229c1c4214f026accf55dadf16e35e0a1712a7876823a0d771.jpg)

Power On

![Four white plates with raised rims and central indentations are arranged in a horizontal row against a plain background. There is no text in the image.](.axe-7420gwa-50m-22811-1000-02/7fbb4649db78d3900b77ba01879fee733fc926c7f7b628d0438cc098de8ee0fa.jpg)

Power Cycle

![The image displays a blue circle containing a white checkmark centered within it.](.axe-7420gwa-50m-22811-1000-02/b7c028bfef3a4b2c31b5f73bdf56bbb32ff44815d6d41933b29a949f00929485.jpg)

Hard Reset

![The image displays a vertical black line on the left side. To the right of this line is a circle drawn with a thin black outline and a white interior, set against a white background.](.axe-7420gwa-50m-22811-1000-02/25d6a388d35790ad37e3179e94fd10e5c43f11bd36a46747e601684840085507.jpg)

ACPI Shutdown

![The image displays two white power icons arranged horizontally on a solid blue background.](.axe-7420gwa-50m-22811-1000-02/ad8435b3acb0bd40cc38a12fdeff6f371d762f9e57e65e4c287f4fd2b7776017.jpg)

Perform Action

The power control consists of the following items.

Power off: Power on the chassis.
Power on: Power off the chassis.
Power Cycle: Power off the chassis and power on the chassis.
Hard Reset: Restart the chassis.
ACPI Shutdown: Soft power off the chassis.

# BMC Settings

The BMC Settings section in the BMC web interface is a centralized location for accessing and modifying a wide range of configuration settings for the BMC.

1. In the BMC web interface, click on the "Settings" button located in the functional menu on the left side.
2. This action will open a group menu that displays various configurable options and settings.

Settings

![Captured BSOD\nLog Settings\nPlatform Event Filter\nSystem Firewall](.axe-7420gwa-50m-22811-1000-02/fb9070b62dcd14dbc8b5fa1d3a29f99f28a999f485f08041ae4a0777a6e4c83f.jpg)

![Date & Time\nMedia Redirection Settings\nServices\nUser Management](.axe-7420gwa-50m-22811-1000-02/0221523705ace6d1f27a80803b466061b4effa8a52ba62df9d4216f2ec67ece5.jpg)

![External User Services\nNetwork Settings\nSMTP Settings\nVideo Recording](.axe-7420gwa-50m-22811-1000-02/7c5b182bb71dcbce5b7654ae9798c094d32340263b2407ad60aafef67b1a7b2f.jpg)

![KVM Mouse Setting\nPAM Order Settings\nSSL Settings\nIPMI Interfaces](.axe-7420gwa-50m-22811-1000-02/a935b0aafab7d583a070820485dd0215bbb1b2eeb9a76299d942d3a39103ddf7.jpg)

# Features

Comprehensive Configuration: This interface allows you to adjust and set most of the BMC's configurations, tailoring the controller to your specific needs and preferences.

Information Retrieval: Besides configuration, this section also provides access to essential information about the BMC and the server it manages.

# Captured BSOD

This page displays a snapshot of the blue screen captured if the host system crashed since last reboot. A screenshot of Captured BSOD is shown below.

![Captured BSOD\nLast BSOD Screen Captured\nterminal File Edit View Search Terminal Help\nroot@amlqa:~\nroot@amlqa:-# 15:23](.axe-7420gwa-50m-22811-1000-02/f1e3c4d9ef62b5979c9adaa35bd2d80e5dd5ccac188c59997f1cd3d85952508c.jpg)

Note: KVM service should be enabled to display the BSOD screen. KVM Service can be configured under Settings > Services > KVM.

# Date & Time

This field is used to set the date and time on the BMC. A sample screenshot of Date & Time is shown as below.

# Date&Time

ConfigureDate&Time
![The left half of a light green circle containing a white question mark.](.axe-7420gwa-50m-22811-1000-02/9a72c518420f7ffe18a89f41952e69e99509cfef923119bf8e429af60647d407.jpg)

![World map with scattered white circular markers indicating locations, no text or labels present](.axe-7420gwa-50m-22811-1000-02/b10930a687eef56712bc3345bce4745c00887cc59382b6803bec11a79c29cd94.jpg)

\_Feb 26,202410:45:52AM(GMT+08:00 CST)-Asia/Shanghai

![The image contains no text. It depicts a simple black-and-white line drawing featuring a thin vertical black line on the left side and a large, empty rectangle with a double-line border to its right.](.axe-7420gwa-50m-22811-1000-02/0e82f2e8648f707e5b173bfa2b6b51668d61d7ade977684fe557a2e8b377fa8d.jpg)

AutomaticNTPDate&Time

![The image displays a cropped vertical section of a graphic interface. On the left side, there is a blue rectangular area containing a white, downward-pointing arrow (or chevron) in its center. To the right of this blue area is a plain white background. There is no text present in the image.](.axe-7420gwa-50m-22811-1000-02/2272b65e14d4799966ac3781e8cbca7b9b89e21cc5f53d106b838c1b6c617422.jpg)

Automatic PTP Date& Time

PTP Interface

![The image features a white background above a solid black horizontal line. Four small, dark, triangular shapes are arranged in a row along the top edge of the black line. There is no text in the image.](.axe-7420gwa-50m-22811-1000-02/406940823c8cb51107123335ca2354fca8f171181ee91a8a50a75db09c5324f3.jpg)

PTP Preset

![The image displays a white background with a thin, horizontal black line running across the center. On the left side of the line, there is a black shape resembling a bow tie or a rolled towel. On the right side, there is a black shape resembling a pair of scissors.](.axe-7420gwa-50m-22811-1000-02/753563b3a46559e1ea4ef01f4c26e1a6c9e9eb4638afcd3e402f42ef5cd18604.jpg)

PTP Transport

![The image displays a black, downward-pointing chevron or arrow symbol centered against a white background.](.axe-7420gwa-50m-22811-1000-02/789163c41d1272d33713bbe5cac26417c0cfd91abd0e2f70e9f0d5ee34aa8e06.jpg)

Unicast

![The image displays a vertical column of six identical black shapes against a plain white background. Each shape is a solid, downward-pointing triangle or chevron, evenly spaced and centered horizontally.](.axe-7420gwa-50m-22811-1000-02/6e71338f5e1cd7742b1f1267e0f5976193f763858fbf8bd4417efa58ecf1e20f.jpg)

PTPUnicast IP

![The image displays a thin, black horizontal line running across the very top edge against a plain white background.](.axe-7420gwa-50m-22811-1000-02/40b76945bf6e80de8858636d764d255b7f2422021f549dbe5ad1eff17350499e.jpg)

PTP Delay Mechanism

E2E

![Two black, downward-pointing chevrons are centered horizontally on a plain white background.](.axe-7420gwa-50m-22811-1000-02/4f97b19752e54411ef9b86082bb04b12438331f6c50b4c16a53c3bba4ccc8bc5.jpg)

PTP Inbound Latency

![The image displays a white background with two thin, horizontal black lines. One line runs across the very top edge, and the other runs across the very bottom edge. There is no text present in the image.](.axe-7420gwa-50m-22811-1000-02/7bd56e73575ef4b88a5759c332fc972df99f3ac0fc8631d9bb0f5a7b933a8bd1.jpg)

PTP Outbound Latency

![The image displays a blank, solid white horizontal rectangle. There is no text or other content visible.](.axe-7420gwa-50m-22811-1000-02/c772c4e8eb1408fb789162ce4c4a4f267de14561bb27556185f2f34ec48cef42.jpg)

PTP Priority1

![The image displays a white rectangular area. A thick black vertical line runs along the entire left edge, and a thin grey horizontal line is visible at the very top edge. There is no text.](.axe-7420gwa-50m-22811-1000-02/26c8fa1f54e756f2ef09e780607465a82bb2aca4c7f91bb5d31f971ec135712c.jpg)

PTP Max Master capacity

5

![The image displays a white background with two thin, vertical black lines running parallel to each other.](.axe-7420gwa-50m-22811-1000-02/4f1c6314178f9bd181525f00e00c331e659753a78a4356c52f87316787a6e027.jpg)

![The image displays a fragment of a grid or table structure on a white background. Visible elements include thin black vertical lines on the far left, center, and right sides, along with horizontal lines near the top. The arrangement of lines suggests a partial view of rectangular cells. There is no text present.](.axe-7420gwa-50m-22811-1000-02/cfa7c3f9d7f8680a012dbb909f3645371356f9e16eb50c506696b424fd843131.jpg)

Panic Mode

PTP Log request delay

Save

The Date & Time section consists of the following fields.

Configure Date & Time: Displays Time zone list containing the UTC offset along with the locations and Navigational line to select the location which can be used to display the exact local time.

Select Time Zone: This field is used to set the date and time on the BMC.

Note: Based on the manual selection of GMT or ETC/GMT, time zone alone will be changed and date & time will remain the same.

Automatic NTP Date & Time: To automatically synchronize Date and Time with the NTP Server.

Primary NTP Server: To configure a primary NTP server to use when automatically setting the date and time. The following address formats & Domain name format are supported:

 IPv4 Address format
 IPv6 Address format
 Domain name format allowed ‘A-Z’, ‘a-z’, ‘0-9’, dash (-), underscore (\_) and dot(.) characters

Secondary NTP Server: To configure a secondary NTP server to use when automatically setting the date and time.

The following address formats & Domain name format are supported

 IPv4 Address format
 IPv6 Address format
 Domain name format allowed ‘A-Z’, ‘a-z’, ‘0-9’, dash (-), underscore (\_) and dot(.) characters

 Automatic PTP Date & Time: To enable/disable the use of PTP servers to automatically set the date and time.
PTP Interface: To configure a PTP server interface to use when automatically setting the date and time.
 PTP Preset: To configure a PTP Preset type to use when automatically setting the date and time.
PTP Transport: To configure a PTP Transport type to use when automatically setting the date and time.
 PTP Ipmode: To configure a PTP Ipmode type to use when automatically setting the date and time.
PTP Unicast IP: To configure a Unicast IP when ipmode is unicast and server to use when automatically setting the date and time.
 PTP Delay Mechanism: To configure a PTP Delay Mechanism type to use when automatically setting the date and time.
 PTP Inbound Latency: To configure an Inbound latency of the server to use when automatically setting the date and time.
 PTP Outbound Latency: To configure a PTP outbound latency server to use when automatically setting the date and time.
PTP Priority1: To configure a priority of PTP clock to use when automatically setting the date and time.
PTP Max Master capacity: To configure a max master capacity of the PTP clock to use when automatically setting the date and time.
Panic Mode: To configure a PTP clock to not reset if jump is more than 1 second, use when automatically setting the date and time.

Save: To save the settings.

Note: If the time zone is selected as Manual Offset, the map selection will be disabled. The Time-Zone settings will be reflected only after saving the settings.

If disable the Automatic Date & Time, the time needs to select by users themselves or the time would not change.

# Procedure

1. Select the Timezone location either using drop down or Map.

2. Enable Automatic Date &Time option to enable/disable the use of NTP servers to automatically set the date and time.

a) In the Primary NTP Server and Secondary NTP Server fields, specify the NTP servers of the device respectively.

Note: Secondary NTP server is optional field. If the Primary NTP server is not working fine, then the Secondary NTP Server will be tried.

3. Enable Automatic PTP Date &Time to enable/disable the use of PTP servers to automatically set the date and time.

a) Enter the Interface, Preset, Transport, Ipmode, Unicast IP, Delay Mechanism, Inbound Latency, Outbound Latency, Priority1, Max Master capacity and Log request delay details in their corresponding fields.
b) Enable/Disable Panic Mode to not reset if jump is more than 1 second, use when automatically setting the date and time.

4. Click Save button to save the settings.

# External User Services

# 8.2.6.3.1 LDAP/E-Directory Settings

The Lightweight Directory Access Protocol (LDAP)/E-Directory Settings is an application

protocol for querying and modifying data of directory services implemented in Internet Protocol (IP) networks.

In MegaRAC GUI, LDAP is an Internet protocol that MegaRAC® card can use to authenticate users. If you have an LDAP server configured on your network, you can use it as an easy way to add, manage and authenticate MegaRAC® card users. This is done by passing login requests to your LDAP Server. This means that there is no need to define an additional authentication mechanism, when using the MegaRAC card. Since your existing LDAP Server keeps an authentication centralized, you will always know who is accessing the network resources and can easily define the user or group-based policies to control access.

To open External User Services page, click Settings -> External User Services from the menu bar. A sample screenshot of External User Services page is shown below.

External User Services

![The image shows a dark grey icon resembling a document or notepad, tilted slightly to the left. On its surface, there are three horizontal white lines stacked vertically, representing text or a list. The object has a slight 3D appearance, with a darker shaded edge on the left side.](.axe-7420gwa-50m-22811-1000-02/813f13b6d5343f7195b4a8694eddf18438f3a1c71c4bbfe9dc7d15da3d519dd2.jpg)

![The image displays two dark, vertical, rounded rectangular shapes positioned side-by-side against a white background. There is no text present.](.axe-7420gwa-50m-22811-1000-02/b88f99216b29b09997ac91cc66d913708d7d7fe0e26ca86b097adf6a61e61ccf.jpg)

![The image displays a blurry, black silhouette of a telephone handset receiver positioned vertically against a plain white background.](.axe-7420gwa-50m-22811-1000-02/a9d0478f2ba8ab054af8d4e7b1d98d171d93cedc766efac9079a5f123e8f51c0.jpg)

To open LDAP/E-DIRECTORY Settings page, click Settings > External User Services > LDAP/E-Directory Settings from the menu bar.

A sample screenshot of External User Services page is shown below.

LDAP/E-Directory Settings

![The image displays a simple black icon of a book, tilted slightly to the right. It features a dark, rounded rectangular shape with two horizontal white lines centered on the cover, resembling text.](.axe-7420gwa-50m-22811-1000-02/813d3536baeb02a66a265a3da90eba584c59541d2ede058409163a1761f50417.jpg)

![The image displays a black and white icon resembling a medal or award. It features a large circle at the top with a thick black outline and a solid black center. Below the circular section are two ribbon tails extending downwards.](.axe-7420gwa-50m-22811-1000-02/73a0d0451143c0abe66e981a3df4ed8380392a7b6a70588ee8228c43ca82e537.jpg)

The fields of LDAP/E-Directory Settings Page are explained below.

General Settings: To configure LDAP/E-Directory Settings. Options are Enable LDAP/E-Directory Authentication, IP Address, Port and Search base.

Role Groups: To add a new role group to the device. Alternatively, double click on a free slot to add a role group.

Note: It is recommended to Enable LDAP configuration from configure general settings page otherwise error message will pop-up stating that "LDAP configuration is not enabled" while trying to create/view LDAP role groups.

# Procedure

Entering the details in General LDAP/E-Directory Settings Page.

1. In the LDAP/E-Directory Settings Page, click General Settings. A sample screenshot of General LDAP Settings page is given below.

General LDAP Settings

![Enable LDAP/E-Directory Authentication\nEncryption Type\n✓ No Encryption ○ SSL ○ StartTLS\nCommon Name Type\n✓ IP Address ○ FQDN\nServer Address\nPort\n389\nBind DN\nE.g., cn=admin,ou=login,dc=domain,dc=com\nPassword\nWhitespace not allowed\nSearch Base\nE.g., ou=login,dc=domain,dc=com\nAttribute of User Login\ncn\nSave](.axe-7420gwa-50m-22811-1000-02/709577fe7033c95b28d9a415afa6c6b7f327b49ad238cf5916cc846c304500b4.jpg)

2. Click Enable LDAP/E-Directory Authentication, to enable LDAP/E-Directory Settings.

Note: During login prompt, use username to login as an LDAP Group member.

3. Select the encryption type for LDAP/E-Directory from the Encryption Type.

Note: Configure proper port number, when SSL is enabled.

4. Select the Common Name Type as IP Address.

5. Enter the IP address of LDAP server in the Server Address field.

Note:

IP Address made of 4 numbers separated by dots as in ‘xxx.xxx.xxx.xxx’.

Each Number ranges from 0 to 255.

First Number must not be 0.

Supports IPv4 Address format and IPv6 Address format.

Configure FQDN address, when using StartTLS with FQDN.

5. Specify the LDAP Port in the Port field.

Note:

Default Port is 389. For SSL connections, default port is 636. The Port value ranges from 1 to 65535.

6. Specify the Bind DN that is used during bind operation, which authenticates the client to the server.

Note:

Bind DN is a string of 4 to 253 alpha-numeric characters.

It must start with an alphabetical character.

Special Symbols like dot(.), comma(,), hyphen(-), underscore(\_), equal-to(=) are allowed.

Example: cn=manager,ou=login, dc=domain,dc=com

7. Enter the password in the Password field.

# Note:

Password must be at least 1 character long.

White space is not allowed.

This field will not allow more than 48 characters.

8. Enter the Search Base. The Search base allows the LDAP server to find which part of the external directory tree to be searched. The search base may be something equivalent to the organization, group of external directory.

# Note:

Search base is a string of 4 to 253 alpha-numeric characters.

It must start with an alphabetical character.

Special Symbols like dot(.), comma(,), hyphen(-), underscore(\_), equal-to(=) are allowed.

Example: ou=login,dc=domain,dc=com.

9. Select Attribute of User Login to find the LDAP/E-Directory server which attribute should be used to identify the user.

Note: It only supports cn or uid.

10. Select CA Certificate File from the Browse field to identify the certificate of the trusted CA certs.

11. Select the Certificate File to find the client certificate filename.

12. Select Private Key to find the client private key filename.

Note: All the 3 files are required, when SSL or StartTLS is enabled.

13. Click Save to save the settings.

# To add a new Role Group

1. In the LDAP/E-Directory Settings Page, Click Role Groups and select a blank row.

Note: It is recommended to Enable LDAP configuration from configure general settings page otherwise error message will pop-up stating that "LDAP configuration is not enabled" while trying to create/view LDAP role groups.

2. Click Add Role Group or alternatively double click on the blank row to open the Add Role group Page as shown in the screenshot below.

Role Groups

![Group Name\nGroup Domain\neg, dc=domain\nGroup Privilege\nKVM Access\nVMedia Access\nSave](.axe-7420gwa-50m-22811-1000-02/399273b0ad9de9c03d6c24549fa2447d8aa0f7480f4ad17f2f361de638890271.jpg)

3. In the Group Name field, enter the name that identifies the role group.

# Note:

Maximum size of Role Group Name is 255 bytes.

Special symbols hyphen and underscore are allowed.

4. In the Group Domain field. Enter the Role Group Domain where the role group is located.

# Note:

Maximum size of Group Domain Name is 255 bytes.

It must start with an alphabetical character.

Special Symbols like dot(.), comma(,), hyphen(-), underscore(\_), equal-to(=) are allowed.

Example: cn=manager,ou=login, dc=domain,dc=com

5. In the Group Privilege field, enter the level of privilege (User, Administrator, Operator, None) to assign to this role group.

6. Select the required options or both.

 KVM Access
 VMedia Access

Note: VMedia privilege is not applicable for LMedia and RMedia clients.

7. Click Save to save the new role group and return to the Role Group List.

# 8.2.6.3.2 Active Directory Settings

An active directory is a directory structure used on Microsoft Windows based computers and

servers to store information and data about networks and domains. An active directory (sometimes referred to as AD) does a variety of functions including the ability to provide information on objects. It also helps to organize these objects for easy retrieval and access, allows access by end users and administrators and allows the administrator to set security up for the directory.

In MegaRAC SP-X application, Active Directory allows you to configure the Active Directory

Server Settings. The displayed table shows any configured Role Groups and the available slots. You can modify, add or delete role groups from here. Group domain can be the AD domain or a trusted domain. Group Name should correspond to the name of an actual AD group.

Note: To view the page, you must be at least a User and to modify or add a group, you must be an Administrator.

To open Active Directory Settings page, click Settings > External User Settings > Active Directory from the menu bar. A sample screenshot of Active Directory Settings page is shown below.

Active directory Settings

![This is a vertical, low-resolution close-up image. On the far left is a thin, black vertical strip. To the right of this strip are two large, vertical, dark grey shapes with rounded tops that resemble buttons or columns. The image is extremely zoomed in, obscuring any specific context, and there is no legible text visible.](.axe-7420gwa-50m-22811-1000-02/f324311f13decf640d5f3a9d2078e46e900e3b3c681163e7be2f0861565b075e.jpg)

![The image displays a low-resolution, grayscale icon resembling a prize medal or rosette. It features a circular top composed of concentric rings, situated above two triangular shapes pointing downward that resemble ribbons.](.axe-7420gwa-50m-22811-1000-02/739cc12fede0007eab528e4cbe28707a9204f75e50e019a515214ffb4a3cdbf8.jpg)

The fields of Active Directory page are explained below.

General Settings: This option is used to configure Active Directory General Settings. Options are Enable Active Directory Authentication, Secret User Name, Secret Password, User Domain name, and up to three Domain Controller Server Addresses.

Role Groups: To add a new role group to the device. Alternatively, double click on a free slot to add a role group.

Note: It is recommended to Enable AD configuration from configure general settings page otherwise error message will pop-up stating that "AD configuration is not enabled" while trying to create/view AD role groups.

# Procedure

# Entering the details in General Active Directory Settings Page

1. Click on General Settings to open the General Active Directory Settings Page.

General Active Directory Settings

![Enable Active Directory Authentication\nSSL\nSecret Username\nSecret Password\nUser Domain Name\nDomain Controller Server Address 1\nDomain Controller Server Address 2\nDomain Controller Server Address 3\nSave](.axe-7420gwa-50m-22811-1000-02/7b4c8c8cbf9a4acb1c1a08b38206406e269c18d66033a62df323df096cc4da0e.jpg)

2. In the Active Directory Settings page, check or uncheck the Enable Active directory Authentication check box to enable or disable Active Directory Authentication respectively.

Note: If you have enabled Active Directory Authentication, enter the required information to access the Active Directory server.

3. SSL: Check or uncheck to enable or disable the SSL.

4. Specify the Secret user name and password in the Secret UserName and Secret Password fields respectively.

# Note:

Secret username/password for AD is not mandatory. When secret username & password is empty, Authentication fails will be always treated as Invalid Password error. For Invalid Password error PAM will not try other Authentication Methods.
User Name is a string of 1 to 64 alpha-numeric characters.
It must start with an alphabetical character.
It is case-sensitive.
Special characters like comma, period, colon, semicolon, slash, backslash, square brackets, angle brackets, pipe, equal, plus, asterisk, question mark, ampersand, double quotes, space are not allowed.
Password must be at least 6 character long and will not allow more than 127 characters.
White space is not allowed.

5. Specify the Domain Name for the user in the User Domain Name field. e.g., MyDomain.com

6. Configure IP addresses in Domain Controller Server Address1, Domain Controller Server Address2 and Domain Controller Server Address3.

# Note:

IP address of Active Directory server: At least one Domain Controller Server Address must be configured.

IP Address made of 4 numbers separated by dots as in "xxx.xxx.xxx.xxx".
Each number ranges from 0 to 255.
First number must not be 0.
Domain Controller Server Addresses will support IPv4 Address format and IPv6 Address format.

# 7. Click Save to save the entered settings and return to Active Directory Settings Page.

![Role Groups\nNone\nNone\nNone\nNone\nNone](.axe-7420gwa-50m-22811-1000-02/09211bdc765a16e80a7f8c3f334e57b6d3a378017836072725dae23014ec4b44.jpg)

The fields of Role Group page are explained below.

Role Group Name: The name that identifies the role group in the Active Directory.

# Note:

Maximum size of Role Group Name is 255 bytes.
Special symbols hyphen and underscore are allowed.

Group Domain: The domain where the role group is located.

# Note:

Maximum size of Group Domain Name is 255 bytes.
Special symbols hyphen, underscore and dot are allowed.

Group Privilege: The level of privilege to assign to this role group.

KVM Access: To provide access to KVM for AD authenticated role group user.

VMedia Access: To provide access to VMedia for AD authenticated role group user.

# To Add a New Role Group

1. In the Active Directory Settings page, select a Role Group and click Add Role Group or alternatively double click on the blank row to open the Add Role group Page as shown in the screenshot below.

Note: It is recommended to Enable AD configuration from configure general settings page otherwise error message will pop-up stating that "AD configuration is not enabled" while trying to create/view AD role groups.

Role Groups

![Group Name\nGroup Domain\neg, MyDomain.com\nGroup Privilege\nKVM Access\nVMedia Access](.axe-7420gwa-50m-22811-1000-02/731f38513018d2b364304e5c2bb63e93ee05f8443f0c769b56e1e1cc29314741.jpg)

2. In the Group Name field, enter the name that identifies the role group in the Active Directory.

# Note:

Maximum size of Role Group Name is 255 bytes.
Special symbols hyphen and underscore are allowed.

3. In the Group Domain field, enter the domain where the role group is located.

# Note:

Maximum size of Group Domain Name is 255 bytes.
Special symbols hyphen, underscore and dot are allowed.

4. In the Group Privilege field, enter the level of privilege to assign to this role group.

5. Select the required options

 KVM Access
 VMedia Access
Note: VMedia privilege is not applicable for LMedia and RMedia clients.

6. Click Save to add the new role group and return to the Role Group List.

# To Delete a Role Group

1. In the Role Groups Page, select the row that you wish to delete.
2. Click Delete Role Group.

# RADIUS Settings

RADIUS is a modular, high performance and feature-rich RADIUS suite including server, clients, development libraries and numerous additional RADIUS related utilities.

In MegaRAC GUI, this page is used to set the RADIUS Authentication.

To open RADIUS Settings page, click Settings -> External User Settings -> RADIUS Settings from the menu bar. A sample screenshot of RADIUS Settings page is shown below.

RADIUS Settings

![The image displays a grey telephone handset icon centered horizontally. Below the icon, the text 'General RADIUS Settings' is written in grey.](.axe-7420gwa-50m-22811-1000-02/5332e0b75f8b44b899df2b7816ab5017f6bdb97a36b31c33a25d9420365c02df.jpg)

![The image displays a white background featuring a centered gray icon resembling a gear composed of puzzle pieces. Directly below the icon is the gray text 'Advanced RADIUS Settings'.](.axe-7420gwa-50m-22811-1000-02/ea58434dbe860889b924744a65453d39ca8d4e47c0253bd435fd0c18160983ec.jpg)

# General RADIUS Settings

General RADIUS Settings

![Enable RADIUS Authentication\nServer Address\n\nPort\n1812\n\nSecret\n\nEnable KVM Access\nEnable VMedia Access\n\nSave](.axe-7420gwa-50m-22811-1000-02/a5a1cab2b409aa1d870f2ed031aefdb0207b9440f59d0c5a851a11fcde160a71.jpg)

The fields of General RADIUS Settings page are explained below.

Enable RADIUS Authentication: Option to enable/disable RADIUS authentication.

Server Address: The IP address of RADIUS server.

# Note:

IP Address (Both IPv4 and IPv6 format).
FQDN (Fully Qualified Domain Name) format.

Port: The RADIUS Port number.

# Note:

Default Port is 1812.
Port value ranges from 1 to 65535.

Secret: The Authentication Secret for RADIUS server.

# Note:

This field will not allow more than 31 characters.
Secret must be at least 4 characters long.
White space is not allowed.

Enable KVM Access: This field provides access to KVM for RADIUS authenticated users.

Enable VMedia Access: This field provides access to VMedia for RADIUS authenticated users.

Save: To save the settings.

# Procedure

1. Enable the RADIUS Authentication check box to authenticate the RADIUS.
2. Click Advanced RADIUS Settings. This opens the Radius Authorization window as shown below.

# Note:

It will not allow more than 127 characters. Special characters like ‘;’ and ‘#’ are not allowed.

It is recommended to Enable Radius configuration from configure general RADIUS settings page otherwise error message will pop-up stating that "Radius configuration is not enabled" while trying to create/view Advanced RADIUS Settings.

Advanced RADIUS Settings

![RADIUS Authorization\nAdministrator\nH=4\nOperator\nH=3\nUser\nH=2\nOEM Proprietary\nH=1\nNo Access\nH=0](.axe-7420gwa-50m-22811-1000-02/9462320fe99a4755fba6fb08c275e16c56cb0a78d7df7899cd9c648b272abdb8.jpg)

For Authorization Purpose, configure the Radius user with Vendor Specific Attribute in server side.

# Example:1

testadmin Auth-Type :=PAP,Cleartext-Password:= "admin"

Auth-Type :=PAP, Vendor-Specific="H=4"

# Example:2

testoperator Auth-Type := PAP, Cleartext-Password := "operator"

Auth-Type :=PAP, Vendor-Specific="H=3"

If you change the Vendor-Specific value in server then you should change the same values in this page.

3. Click Save to save the changes made.

# Service Management

It is used to set service information on the BMC. A sample screenshot of service management is shown as below.

Services
Home

<table><tr><td>Service ⇆</td><td>Status ⇆</td><td>Interfaces ⇆</td><td>Secure Port ⇆</td><td>Timeout ⇆</td><td>Maximum Sessions ⇆</td><td></td></tr><tr><td>web</td><td>Active</td><td>both</td><td>443</td><td>1800</td><td>20</td><td>≡ √</td></tr><tr><td>kvm</td><td>Active</td><td>both</td><td>443</td><td>1800</td><td>4</td><td>≡ √</td></tr><tr><td>cd-media</td><td>Active</td><td>both</td><td>443</td><td>N/A</td><td>4</td><td>≡ √</td></tr><tr><td>hd-media</td><td>Active</td><td>both</td><td>443</td><td>N/A</td><td>4</td><td>≡ √</td></tr><tr><td>ssh</td><td>Active</td><td>NA</td><td>22</td><td>600</td><td>N/A</td><td>≡ √</td></tr><tr><td>watchdog</td><td>Inactive</td><td>NA</td><td>N/A</td><td>N/A</td><td>1</td><td>≡ √</td></tr></table>

The service management consists of the following items.

web
kvm
cd-media
hd-media
ssh
watchdog

(Click the "edit" button in the "watchdog" column to enter the "watchdog" configuration interface (the interface is as follows), watchdog default state is inactive, if watchdog is set to the active state, it will monitor the BMC in real time.)

# Service Configuration

![Service Name\nwatchdog\nActive\nMaximum Sessions\n1](.axe-7420gwa-50m-22811-1000-02/b7df9f6bd5adcd8c47ba2668804942955d4d19d7a5a50c42334234093554505b.jpg)

# Network Configuration

Note: Change the IP settings of the management ports will disconnect the network.

This section is used to configure the network settings for the available LAN channels.

# 8.2.6.6.1 Network IP Settings

This section is used to configure the network IP settings.

To open the Network IP Settings page, click Settings -> Network Settings -> Network IP Settings.

Network IP Settings

![Enable LAN\nLAN Interface\neth0\nMAC Address\n00:30:64:66:77:88\nEnable IPv4\nEnable IPv4 DHCP\nIPv4 Address\n188.188.1.100\nIPv4 Subnet\n255.255.255.0\nIPv4 Gateway\n188.188.1.1](.axe-7420gwa-50m-22811-1000-02/638aaa40c0321d2e9a32f56ef50352a99d6073bb42c22ce1ed20cc003aa8480f.jpg)

The fields of Network IP Settings page are explained below.

 Enable LAN: Enable or disable the LAN settings.
 LAN Interface: Select the LAN interface to be configured.
 MAC Address: Display the read-only MAC Address of the selected interface.
 Enable IPv4: Enable or disable the IPv4 settings for the selected interface.
 Enable IPv4 DHCP: Enable or disable the IPv4 DHCP support for the selected interface. If disable the IPv4 DHCP support, then static IP address is selected, configure the static IPv4 Address, IPv4 Subnet, and IPv4 Gateway.

# Notes:

 An IP address consists of 4 numbers separated by dots, as in "xxx.xxx.xxx.xxx".
 Each number ranges from 0 to 255.
 The first number must not be 0.

![A blue square icon featuring a white checkmark in the center.](.axe-7420gwa-50m-22811-1000-02/e2d8b8e8c9c3114ca747959e50caf28fc30f6864a198a707e0f05a085a98f43b.jpg)

Enable IPv6

![The image displays a vertical schematic or diagram. In the center is a large white rectangle. Flanking this rectangle on both the left and right sides are thin vertical gray lines. Outside of those gray lines are thicker black vertical bars. On the far left and far right edges, there are additional thin vertical gray lines.](.axe-7420gwa-50m-22811-1000-02/e5520bf058b8a31bf1b58540e503228bcbe21fab69408d9c9c3fe67482e50834.jpg)

Enable IPv6 DHCP

IPv6 Index

0

&lt;

IPv6 Address

fe80::15ca:1212:749e:8f27%4

Subnet Prefix Length

0

IPv6 Gateway

 Enable IPv6: Enable or disable the IPv6 configuration settings.
 Enable IPv6 DHCP: Enable or disable the IPv6 DHCP support for the selected interface. It dynamically configures IPv6 address using DHCP (Dynamic Host Configuration Protocol).

Note: Disable this Enable IPv6 DHCP field and enter the values in following fields such as IPv6 Index, IPv6 Address, Subnet Prefix Length and IPv6 Gateway.

 IPv6 Index: Specify a static IPv6 index to be configured to the device. E.g.: 0
 IPv6 Address: Specify a static IPv6 address to be configured to the device. E.g.: 2004::2010.
 Subnet Prefix Length: Specify the subnet prefix length for the IPv6 settings. The value ranges from 0 to 128.
 IPv6 Gateway: Specify an IPv6 default gateway for the IPv6 settings.

![The image displays a diagram consisting of three adjacent rectangular boxes arranged horizontally. From left to right, the boxes contain the letters 'A', 'B', and 'C' respectively.](.axe-7420gwa-50m-22811-1000-02/ece67f9358c6046a7ff3b6e15b87e2a3db9dc881b6d5198e446a7f3e8dfb8f3e.jpg)

Enable VLAN

VLAN ID

VLAN Priority

![The image features a white, pixelated icon of a floppy disk centered on a solid blue background. This is the universal symbol for 'Save.' The icon consists of a rectangular outline with a smaller rectangular cutout near the top and a square cutout in the lower right section.](.axe-7420gwa-50m-22811-1000-02/cd663b7330224db9f6f9f55bc5a3ef9aa4fa3793e80904342fc45a832d7c3a14.jpg)

Save

 Enable VLAN: Enable or disable VLAN support for the selected interface.
 VLAN ID: Value ranges from 2 to 4094. VLAN ID 0, 1 & 4095 are reserved VLAN IDs.
 VLAN Priority: Value ranges from 0 to 7. 7 is the highest priority for VLAN.
 Save: Save the entries.

# 8.2.6.6.2 Network Link Configuration

This section is used to configure the network link.

To open Network Link Configuration page, click Settings &gt;Network Settings > Network Link Configuration.

Network Link Configuration

![LAN Interface\neth1\n✓ Auto Negotiation\nLink Speed\n100 Mbps\nDuplex Mode\nFULL Duplex\nNCSI Interface\nEnabled\nSave](.axe-7420gwa-50m-22811-1000-02/d598013d99533c9afe313f5306e0596ee6256295f6e5cefc472da241dfd53360.jpg)

The fields of the Network Link Configuration page are explained below.

 LAN Interface: Select the required network interface from the list to which the link speed and duplex mode are to be configured.
 Auto Negotiation: Enable to allow the device to perform automatic configuration to achieve the best possible mode of operation (speed and duplex) over a link.
 Link Speed: Link speed will list all the supported capabilities of the network interface. It can be 10/100/1000 Mbps.

Note: Link speed of 1000 Mbps is not applicable when Auto Negotiation is OFF.

 Duplex Mode: This field could be either Half Duplex or Full Duplex.
 NCSI Interface: The NCSI interface status could be either Enabled or Disabled for the selected LAN interface.
 Save: Save the settings.

# 8.2.6.6.3 DNS Configuration

The Domain Name System (DNS) is a distributed hierarchical naming system for computers,

services, or any resource connected to the Internet or a private network. It associates the information with domain names assigned to each of the participants. Most importantly, it translates domain names meaningful to humans into the numerical (binary) identifiers associated with networking equipment for the purpose of locating and addressing these devices worldwide.

This section is used to manage the DNS settings of a device.

To open DNS Configuration page, click Settings > Network Settings > DNS Configuration.

DNS Configuration

![DNS Enabled\nmDNS Enabled\nHost Name Setting\nAutomatic Manual\nHost Name\nAMI003064667788](.axe-7420gwa-50m-22811-1000-02/948bcfa96aef607364559c1db33656cfc520b27fe54896b89e773e1b513b5b1f.jpg)

The fields of DNS Configuration page are explained below.

# Domain Name Service Configuration

 DNS Enabled: Enable or disable all the DNS service configurations.
 mDNS Enabled: Enable or disable the multicast DNS.
 Host Name Setting: Choose either Automatic or Manual settings.
 Host Name: Display host name of the device.

If the Host setting is chosen as Manual, then specify the host name of the device.

# Notes:

 Value ranges from 1 to 64 alpha-numeric characters.
 Special character ‘-’(hyphen) is allowed.
 It must not start or end with a ‘-’(hyphen).
 The underscore (\_) character and double hyphen (--) character are not a legal character for use in host names.

BMC Registration Settings

BMC Interface

etho

![The image shows a blue square containing a white checkmark centered within it.](.axe-7420gwa-50m-22811-1000-02/1e932185febf457b29c1e55d0b05ddf18cb94a356b9ad36a99e6d89a5a96eb9f.jpg)

Register BMC

Registration Method

![A blue circle with a white check mark in the center.](.axe-7420gwa-50m-22811-1000-02/fb37c57bfcd65ca492517ca10b0273764a353938235ac256d24ea23d497f48a5.jpg)

Nsupdate

![Three white circles are arranged horizontally against a light grey background, separated by thin vertical black lines.](.axe-7420gwa-50m-22811-1000-02/4e214db44f652506ddd81fb878e8826ca191d78c930116304ddd8d62b145f981.jpg)

DHCP Client FQDN

![The image displays a vertical composition featuring solid black bars on the left and right edges. Centered between them is a large white square. Inside this white square is a concentric square outline drawn in a thin, faint gray line.](.axe-7420gwa-50m-22811-1000-02/bc2c3b5c26d333a0525380378da9223f7536996e39adba16c0f25907897c4d0d.jpg)

Hostname

BMC Interface

eth1

![The image displays a cropped view of a digital interface featuring two adjacent light blue squares. Each square contains a centered white checkmark. A thin dark vertical strip runs along the far left edge.](.axe-7420gwa-50m-22811-1000-02/680b0dde51ede63d7085ba667fb6c7d6e4c986e13bcee3fcda693ae970758c90.jpg)

Register BMC

Registration Method

![The image displays a blue circle containing a white checkmark in the center.](.axe-7420gwa-50m-22811-1000-02/28a272b6ac299412b6ba0b0b237af7b82e66ea24e4ad439f9fe36164726d591f.jpg)

Nsupdate

![The image displays three white circles aligned horizontally in a row against a black background. A black horizontal bar runs across the very top edge of the image.](.axe-7420gwa-50m-22811-1000-02/5e3e5e52e0ee979515e5b2184481ef1016fc488d75f1e7faee75b8ee1e8cbb50.jpg)

DHCP Client FQDN

![The image displays a white background with a thin black horizontal line running across the very top edge. Below this line are two white circles with thin grey outlines, positioned side-by-side. There is no visible text.](.axe-7420gwa-50m-22811-1000-02/5a3ef8c5834fdeaadee07f115ecf3eda9936b01fc9225968f97c4d4a739d6056.jpg)

Hostname

# BMC Registration Settings

 BMC Interface: Options to register the BMC through the Interfaces (eth0&eth1).
 Register BMC: Register BMC through registration method.
 Registration Method: Options to register the BMC through Nsupdate or DHCP Client FQDN or Hostname.

![Both\nEth0 TSIG Configuration\nTSIG Authentication Enabled\nCurrent TSIG Private File Information\nNot Available\nNew TSIG Private File\nEth1 TSIG Configuration\nTSIG Authentication Enabled\nCurrent TSIG Private File Information\nNot Available\nNew TSIG Private File](.axe-7420gwa-50m-22811-1000-02/0a9db855a137b57c95445aa9b776e6acf00c46cfa757bb7c1c2f7f625fbd4803.jpg)

# TSIG Configuration

 Both: Check this option to modify TSIG authentication for both interfaces.
 Eth 0&1:

TSIG Authentication Enabled: Check this box to enable TSIG authentication while registering DNS via nsupdate. Separate TSIG files can be uploaded for each LAN interface.
Current TSIG Private File Information: The information of current TSIG private file along with its uploaded date and time will be displayed (read only).
New TSIG Private File: Browse and navigate to the TSIG private file.

Domain Setting

![A blue circle containing a centered white checkmark.](.axe-7420gwa-50m-22811-1000-02/9b06e6acd286c1e81cfb48e008bea79880dde0aee72665cc4dfbfd62c06ab139.jpg)

Automatic

![The image displays two identical white circles with thin black outlines, arranged vertically with one positioned directly above the other on a white background.](.axe-7420gwa-50m-22811-1000-02/240469751a157c9cb7eae4c12036c2f94e0b4621838d0fc76e3d406a38bb6cec.jpg)

Manual

Domain Interface

eth1\_v4

 Domain Setting: Select whether the domain interface will be configured manually or automatically.

Automatic: If you select Automatic, the Domain Name cannot be configured as it will be done automatically.
Manual: If you select Manual, then specify the domain name of the device.

# Notes:

 If you select Automatic, it displays the Domain Interface option. If you select Manual, it displays Domain name.
√ Domain name must be a string of 4 to 253 alphanumeric characters. (254 characters are allowed only if the last byte is dot.)

 Domain name must start with a letter and end with a letter or digit. (Must contain at least one dot character) Only letters, digits, dot and hyphen are allowed.

Domain Name Server Setting

![A blue circle containing a white checkmark in the center.](.axe-7420gwa-50m-22811-1000-02/6fc3149c1538567cc07678a06a1102fb4eba35bafe9cd592fef3a712e632b096.jpg)

Automatic

![The image displays four white circles arranged horizontally in a row. There is no text present.](.axe-7420gwa-50m-22811-1000-02/e585312b86471c84b5b900cb9d80d8e9e1cf4ad65ca89fa936377192cdd24a79.jpg)

Manual

DNS Interface

IP Priority

![The image displays a blue circle containing a white checkmark in its center. The checkmark is stylized with a thick stroke. The circle appears to be part of a user interface icon, likely indicating a 'success' or 'completed' status. There is no text in the image.](.axe-7420gwa-50m-22811-1000-02/db32c7f697f8f36fc6a8cb3c2bcaf2686e866bb98a736a1e2fa4c63f4623f38c.jpg)

IPv4

![The image displays three identical white circles arranged horizontally in a row against a black background. The circles are evenly spaced and appear to be part of a loading or progress indicator.](.axe-7420gwa-50m-22811-1000-02/3086c7a7bc297254f35d0da5aa116c238b733df8271fe027a436fd17e4602925.jpg)

IPv6

![The image features a white icon of a floppy disk, commonly used to represent the 'Save' function, set against a solid blue background. The icon is positioned on the right side of the frame, next to a thin vertical strip visible along the far left edge.](.axe-7420gwa-50m-22811-1000-02/5ca0a89a270b7b833ddd2078b9b541ad3bf78e05e9a483a6a873c353cab48304.jpg)

Save

 Domain Name Server Setting:

Automatic - If you select Automatic, DNS Interface option should be explained.
Manual - Specify the DNS (Domain Name System) server address to be configured for the BMC.

 IP Priority:

IPv4: It will have 2 IPv4 DNS servers and 1 IPv6 DNS server.
IPv6: It will have 2 IPv6 DNS servers and 1 IPv4 DNS server.
Note: This is not applicable for Manual configuration.

 DNS Server 1, 2 & 3:

Specify the DNS (Domain Name System) server address to be configured for the BMC.

# Notes:

IPv4 Addresses should be given in dotted decimal representation.
IPv6 Addresses are supported and must be global unicast addresses.
DNS Server Address will support the following:

 IPv4 Address format.

 IPv6 Address format.

 Save: Save the entered changes.

# 8.2.6.6.4 Sideband Interface (NC-SI)

This section is used to configure Network Controller Sideband Interface (NCSI) settings.

To open the Sideband Interface (NC-SI) page, click Settings > Network Settings > Sideband Interface (NC-SI).

Sideband Interface (NC-SI)

![NCSI Mode\n✓ Auto Failover Mode ○ Manual Switch Mode\nNCSI Interface\neth1\nPackage ID\n0 (active)\nChannel Number\n0 (package 0)(active)](.axe-7420gwa-50m-22811-1000-02/5c9577eaa6fdc365fe36f212e975240071df907a268a9e0ab0d0ba9d5e21d8fe.jpg)

The fields of the Sideband Interface (NC-SI) page are explained below.

 NCSI Mode:

If you select Auto Failover Mode, the NCSI interface and other settings will be configured automatically.
If you select Manual Switch Mode, you are allowed to configure the below settings.

 NCSI Interface: Select the NSCI interface for which you need to configure NCSI settings.
 Package ID: Select the package ID to be configured for the selected interface.
 Channel Number: Select the channel number to be configured for the selected interface.
 Save: Save the settings.

# Remote Management

The "Remote Control" includes two functions: KVM and SOL, KVM is mainly used to remotely access the x86 system through WEB, and SOL is mainly to access x86 BIOS configuration information through WEB, WEB UI is as follows.

Remote Control Remote KVM& SOL

H5Viewer

![This image displays a cropped section of a bright green interface element, likely a button. It features a white icon depicting an arrow pointing diagonally upwards and to the right, emerging from the corner of an open square, which is the standard symbol for 'open in new tab' or an external link. There is no visible text in the image.](.axe-7420gwa-50m-22811-1000-02/06d7e143ddb25f6de6f1b176645f3d3ad992105cf63206b573c8b0615db99b48.jpg)

Launch H5Viewer

Serial Over LAN

![The image displays a cropped, low-resolution section of a white icon set against a solid bright green background. The icon consists of a square outline with an arrow inside it, pointing diagonally upwards and to the right from the upper right corner, resembling a 'share' or 'external link' symbol. There is no text visible in the image.](.axe-7420gwa-50m-22811-1000-02/844d61cc25a6264f7948006936e7aa2fbd188015356c81f25c7a51f5520516c5.jpg)

Activate

# KVM

# Launch H5Viewer

The system and browser requirements for Remote Control are given below.

# System Requirements

Client machine with 8GB RAM.

If the client machine has 4GB RAM or lower, there will be lag in Video/Keyboard/ Mouse/Media redirection functionality.

# Supported Browsers

 Chrome latest version
 IE11 and above
 Firefox (with limited support)
 Edge
 Safari (On Mac only)

Note: It is advisable to use Chrome or IE for H5Viewer, since Firefox has its own memory limitations.

To open Remote Control page, click Remote Control from the menu bar. A detailed description of the menu items is given below.

Open the "Remote Control" page, click "Launch H5Viewer". A sample screenshot of the Remote KVM page is shown below.

![Remote KVM (172.20.2.137) - (1024 x 768 ) - Google Chrome\n不安全 https://172.20.2.137/viewer.html\nStop KVM\nCD Image: Browse File (0 KB) Start Media\nVideo Mouse Options Keyboard Send Keys Hot Keys Video Record Power Active Users Help\nZoom 100%\n1月 19 11:21\nUsername\nUbuntu\nLWIN RWIN LALT LCTRL RALT RCTRL NUM CAPS SCR](.axe-7420gwa-50m-22811-1000-02/919d6ab07b73057f800dfa981b233e4eb9656f6bea5da4805aeca4fbd5c385b5.jpg)

# Procedure to Start KVM

1. Click Launch H5Viewer to open the Remote Control KVM page.
2. To stop the H5Viewer video redirection, click Stop KVM.

# Procedure to Start /Stop Media

1. Click Browse File to select CD Image. After selecting the image, Select/Unselect media boost option.
2. Click Start Media to redirect the selected CD image file to the Host. A sample screenshot is as shown below. Note: If media boost mode is selected, the processes related to media redirection will have high priority than other processes. This will improve media performance but other processes will have limited access to CPU cycle.

CD Image:ubuntu-22.04-desktop-amd64.iso (14665 KB) □ Media Boost Stop Media

3. To stop the CD Image redirection, click Stop Media.

A detailed description of menu items are given below.

# Video

This menu contains the following sub menu items.

Pause Video: This option is used for pausing Console Redirection.

Resume Video: This option is used to resume the Console Redirection when the session is paused.

Refresh Video: This option can be used to update the display shown in the Console Redirection window.

Capture Screen: This option helps to take the screenshot of the host screen and save it in the client s system.

# Mouse

Show Client Cursor: This menu item can be used to show or hide the local mouse cursor on the remote client system.

Mouse Mode: This option handles mouse emulation from local window to remote screen using either of the two methods. Only Administrator has the right to configure this option.

Absolute mouse mode: The absolute position of the local mouse is sent to the server if this option is selected.
Relative mouse mode: The Relative mode sends the calculated relative mouse position displacement to the server if this option is selected.
Other mouse mode: This mouse mode sets the client cursor in the middle of the client system and sends the deviation to the host. This mouse mode is specific for SUSE Linux installation.

Note: AMI MegaRAC SP‐X suggests users to use Linux version of OS except SUSE11.4 with BMC to avoid mouse sync issue in absolute mouse mode.

Client cursor will be hidden always. If you want to enable, use Alt + C to access the menu.

# Options

# Zoom:

Normal - By default, this option is selected.

Zoom In - For increasing the screen size. This zoom varies from 100% to 150% with an interval of 10%

Zoom Out - For decreasing the screen size. This zoom varies from 100% to 50% with an interval of 10%

Block Privilege Request: To enable or disable the access privilege of the user.

\*Compression Mode: This option helps to compress the Video data transfer to the specific mode.

\*DTC Quantization Table: This option helps to choose the video quality.

Note: \*Specific to AST SOC.

# Keyboard

Keyboard Layout: This feature is fully compatible when host and client has the same keyboard language layout. If the client and host language layouts differ, some special characters will not be compatible.

List of Host Physical Keyboard languages supported in SPX H5Viewer.

 English U.S.
 German.
 Japanese.

# Send Keys

This option is used to key items. This menu contains the following sub menu items.

Hold Down

Press and Release

# Hold Down

This menu contains the following sub menu items.

Right Ctrl Key: This menu item can be used to act as the right-side &lt;CTRL&gt; key when in

Console Redirection.

Right Alt Key: This menu item can be used to act as the right-side &lt;ALT&gt; key when in

Console Redirection.

Right Windows Key: This menu item can be used to act as the right-side &lt;WIN&gt; key when in Console Redirection.

Left Ctrl Key: This menu item can be used to act as the left-side &lt;CTRL&gt; key when in

Console Redirection.

Left Alt Key: This menu item can be used to act as the left-side &lt;ALT&gt; key when in

Console Redirection.

Left Windows Key: This menu item can be used to act as the left-side &lt;WIN&gt; key when in Console Redirection.

You can also decide how the key should be pressed: Hold Down or Press and Release.

# Press and Release

Ctrl+Alt+Del: This menu item can be used to act as if you depressed the &lt;CTRL&gt;,

&lt;ALT&gt;and&lt;DEL&gt; keys down simultaneously on the server that you are redirecting.

Left Windows Key: This menu item can be used to act as the left-side &lt;WIN&gt; key when in Console Redirection.

You can also decide how the key should be pressed: Hold Down or Press and Release.

Right Windows Key: This menu item can be used to act as the right-side &lt;WIN&gt; key when in Console Redirection.

Context Menu Key: This menu item can be used to act as the context menu key, when in Console Redirection.

Print Screen Key: This menu item can be used to act as the print screen key, when in Console Redirection.

# Hot Keys

This menu is used to add the user configurable shortcut keys to invoke in the host machine. The configured key events are saved in the BMC.

This menu contains the following sub menu items.

• Add Hot Keys - This menu is used to enable macros. Click Add to macros.

# Video Record

This menu contains the following sub menu items.

Record Video: This option is to start recording the screen.

Stop Recording: This option is used to stop the recording.

Record Settings: This option is used to set video record duration and video compression value. Video record duration value should be in the range of 1 to 1800 seconds. Video Compression value should be in the range of 0.1 (Low image quality) to 1.0 (High image quality).

Normalized video resolution to 1024 X 768 (\*specific to AST SOC): Host video will be scaled to 1024 x 768 in the recorded video file. Enabling this option improves client-side video recording performance in H5Viewer.

Disable this option to record video at same resolution as host video. The host video capture depends on client system performance. If this option is disabled, recorded video file may have inconsistency. (i.e., Recorded video file duration may not be the same as configured value).

# Note:

The Maximum video file size allowed is around 40MB. If the video file size reaches its max size limit, the recorded file is downloaded and recording will be in progress until the configured video recording time is reached. The video file is saved as video date‐month‐year hr‐min‐sec part no in client side video recording.

User have to take care of saving the video files in different browsers.

When H5Viewer focus is lost and if video recording is in progress, the recording will be stopped with a notification message and the recorded video file will be discarded.

Due to browser limitation, Set timeout/set interval will be delayed from specified time of interval when browser window loses focus, hence video server will not send the video packets to H5Viewer and so the video recording will be stopped.

# Power

The power options are to perform any power cycle operation. Click on the required option to perform the following operation.

Reset Server: To reboot the system without powering off (warm boot).

Immediate Shutdown: To perform Power OFF Immediately.

Orderly Shutdown: To Power OFF the server in proper order.

Power ON Server: To Power ON the server.

Power Cycle Serve: To first power off, and then reboot the system (cold boot).

# Active Users

Click this option to display the active users and their system IP address.

Active KVM Session can be terminated when there are multiple KVM Session from Master [FULL Privilege KVM Session].

# Help

Click this option to get more information About H5Viewer. The KVM Remote Console utility version and plugin version will be displayed.

# Quick Buttons

Quick Buttons: The upper right of H5Viewer window displays all the quick buttons. These quick buttons allow you to perform the below functions by clicking them.

<table><tr><td>Quick Buttons</td><td>Explanation</td></tr><tr><td></td><td>This quick button will show / hide notifications dropdown menu, which will contain the list of notifications displayed by H5Viewer.</td></tr><tr><td>Zoom 100%</td><td>It shows the current zoom value in percentage.</td></tr><tr><td>&lt;img src="images/73d3e0fbcebf9dab50213f29ef4a6d2f42b7c6f5275f5b1518ce6e4ed894ee8a.jpg"/&gt;</td><td>This quick button is used to display the current host monitor status. If icon is in green color, then host monitor is unlocked. If the icon is in red color host monitor is locked. By clicking the button, host monitor status can be toggled.This quick button is used to display the current server power status. If the icon is in green color, the server status is powered on. If the icon is in red color, the server status is powered off. Click the button to toggle immediate power off / power on the host.</td></tr></table>

# Status bar buttons

<table><tr><td>LWIN</td><td>RWIN</td><td>LALT</td><td>LCTRL</td><td>RALT</td><td>RCTRL</td><td>NUM</td><td>CAPS</td><td>SCR</td></tr></table>

Num/Caps/Scroll lock buttons are LED status buttons that denotes the current status of Num/Caps/ Scroll lock in the host.

# Keyboard LED Sync

When the H5Viewer is launched, the keyboard locks status and LEDs denoting the lock status of the host machine, should be in sync with the client machine. That is, if the Num/Caps/Scroll lock is enabled/disabled in the client machine, the same should be updated in the host machine as well.

# Note:

# Client-Side Limitations

Due to web browser related security concerns, this feature has following limitations.

‐ Host LEDstatus will be synced with client LEDstatus, only if user pressesany key in client keyboard when H5Viewer window is in focus.
‐ Client keyboard LED status cannot be updated from web browsers.

# Host Side Limitations

In some Linux hosts, when the host is booted into text mode, CAPS LOCK LED status will not be updated properly. CAPS LOCK LED will not turn ON/OFF while changing the CAPS lock status in the host OS.
‐ In such cases, H5Viewer CAPS LOCK synchronization functionality will not work properly.
‐Example ‐ Typing letters in H5Viewer (after pressing CAPS LOCK) will toggle between lower to upper case inside host.

# KVM Sharing

MegaRAC SP-X stack supports N number of KVM redirection sessions. Only one full permission H5Viewer session at a time. With Full permission in H5Viewer, the user can control the KVM redirection, and the other H5Viewer users can only view the video redirected from the server without intervention.

When the First user launches H5Viewer, the user will get full permission to control the host during KVM redirection. When another H5Viewer session is launched, the Video server will send KVM sharing permission request packet to the current session, for the new Requesting session.

Once the requesting session is authenticated, a packet containing the information such as the client IP/hostname and user name of the newly authenticated or logged in user, will be send to the current session. The first client shows the dialog as a shown below:

# Slave Permission

admin user with IP address 172.20.2.72 is trying to connect. What level of permission do you wish to grant them?(If Full Permission is selected, active H5Viewer media redirection will be terminated)

You have 4 more seconds to make a decision.The YES option will be chosen if no answer is obtained.

Full Permission

Partial Permission

Block Privilege Request

No Permission

Partial Permission

No Permission

Clicking the button in the dialog box will trigger specified action:

Full Permission: When this button is clicked, the requesting session will receive full access permission, and the current (full permission) session will have a partial KVM access permission only.

Partial Permission: When this button is clicked, the requesting session will receive partial permission and can only view server display (Video only).

Block Privilege Request > Partial Permission: Once this option is selected, both newly requesting session and active partial privileged session will get partial permission as auto response and can only view server display. Further request will be served by auto response mechanism.

Block Privilege Request > No Permission: Once this option is selected, both newly requesting session and active partial privileged session access will be denied as auto response. Further request will be served by auto response mechanism.

No Permission: When this button is clicked, the requesting session access will be denied.

# SOL

The serial over LAN (SOL) feature is very useful, and the SOL redirects the local serial interface via an IPMI session, allowing remote access to the console.

Click the "Active" button on the "Remote Control" interface to enter the SOL output window, and then enter the BIOS configuration interface, and the content of the BIOS configuration will be redirected to the WEB UI, as shown in the following figure.

<table><tr><td colspan="5">Aptio Setup - AMI</td><td></td></tr><tr><td>Main</td><td>Advanced</td><td>Platform</td><td>Configuration</td><td>Socket Configuration</td><td>Server Mgmt S</td></tr><tr><td>BIOS Information</td><td></td><td></td><td></td><td></td><td>Set the Date.</td></tr><tr><td>BIOS Vendor</td><td></td><td></td><td>American Megatrends</td><td></td><td>switch between</td></tr><tr><td>BIOS Version</td><td></td><td></td><td>1.2.10</td><td></td><td>Default Range</td></tr><tr><td>Build Date</td><td></td><td></td><td>01/24/2024</td><td></td><td>Year: 1998-99</td></tr><tr><td>RC Version</td><td></td><td></td><td>370.P03</td><td></td><td>Months: 1-12</td></tr><tr><td>SPS FW Version</td><td></td><td></td><td>6.1.2.48</td><td></td><td>Days: Depende</td></tr><tr><td></td><td></td><td></td><td></td><td></td><td>Range of Year</td></tr><tr><td>System Information</td><td></td><td></td><td></td><td></td><td></td></tr><tr><td>Project Name</td><td></td><td></td><td>MECS-7120</td><td></td><td></td></tr><tr><td>CPU Board Version</td><td></td><td></td><td>A1</td><td></td><td></td></tr><tr><td>CPU Brand String</td><td></td><td></td><td>Intel(R) Xeon? Gold 542 3N</td><td></td><td></td></tr><tr><td>CPU Frequency</td><td></td><td></td><td>2.10GHz</td><td></td><td>-----</td></tr><tr><td>Total Memory</td><td></td><td></td><td>16384 MB (DDR5)</td><td></td><td>&gt;&lt;: Select Sc</td></tr><tr><td>Memory Frequency</td><td></td><td></td><td>4000 MHz</td><td></td><td>^v: Select It</td></tr><tr><td>PCH SKU</td><td></td><td></td><td>EBG B1</td><td></td><td>Enter: Select</td></tr><tr><td></td><td></td><td></td><td colspan="2">---- Save &amp; Exit ----</td><td>+/-: Change O</td></tr><tr><td>System Date</td><td></td><td></td><td rowspan="3" colspan="2">Quit without saving?</td><td>F1: General H</td></tr><tr><td rowspan="2">System Time</td><td rowspan="2"></td><td rowspan="2"></td><td>F8: Previous</td></tr><tr><td>F9: Optimized</td></tr><tr><td rowspan="2">Access Level</td><td rowspan="2"></td><td rowspan="2"></td><td colspan="2">----</td><td>F10: Save &amp; E</td></tr><tr><td colspan="2">Yes No</td><td>ESC: Exit</td></tr><tr><td>PCH SKU</td><td></td><td></td><td colspan="2">----</td><td></td></tr></table>

# Server Maintenance

This function is mainly maintenance tasks on the device. Click Maintenance on the left function bar to enter the following interface.

![Maintenance\nBackup Configuration\nDual Image configuration\nFirmware Image Location\nFirmware Information\nFirmware Update\nPreserve Configuration\nRestore Configuration\nRestore Factory Defaults\nSystem Administrator](.axe-7420gwa-50m-22811-1000-02/da2c1c31924e325e1ebbee6a41095313a8178f1f8d4649435d9ed3ae212604a4.jpg)

# Firmware Update

The system upgrade function is for updating and maintaining the system. Mainly used to update BMC and BIOS. Here's how to update via the Web.

# 8.2.8.1.1 BMC Update

# Preserve Configuration

This page allows the user to configure the preserve configuration items, which will be used by the Restore factory defaults to preserve the existing configuration without overwriting with defaults/Firmware Upgrade configuration.

To open Preserve Configuration page, click Maintenance > Preserve Configuration from the menu bar. A sample screenshot of Preserve Configuration page is shown below.

![Preserve Configuration\nClick here to go to Firmware Update or Restore Factory Defaults\nCheck All\nSDR\nFRU\nSEL\nIPMI\nNetwork\nNTP\nSNMP\nSSH\nKVM\nAuthentication\nSyslog\nWeb\nExtlog\nRedfish\nSave](.axe-7420gwa-50m-22811-1000-02/b297ab8ec29e918ea806d331dd1ac4229e88da19e0e507e4be7db02cddef87d6.jpg)

The various fields of Preserve Configuration are as follows.

Click here to go to Firmware Update or Restore Factory Defaults: This link will redirect to the Firmware Update or Restore Factory Defaults page which needs to be preserved.

Check All: To check the entire configuration list.

Save: To save any changes made.

# Procedure

1. Click Firmware Update or Restore Configuration link to view Firmware Update or Restore Configuration page accordingly.
2. Select the required Preserve Configuration items by either choosing the items individually by selecting the appropriate check boxes or by selecting all or none using Check All.
3. Click Save to save the changes.

# Firmware Update

This wizard takes you through the process of firmware upgradation. A reset of the box will automatically follow if the upgrade is completed or cancelled. An option to Preserve All Configuration is available. Enable it, if you wish to preserve configured settings through the upgrade.

To perform Dual Firmware Update operation, click Maintenance > Firmware Update from the menu bar.

# Procedure

1. Click Browse to select firmware image.

Note: A file upload pop-up will be displayed for http/https but in the case of tftp files, the file is automatically uploaded displaying the status of upload.

2. Click Start firmware update to load the Firmware Update information. A sample screenshot is displayed below.

![Firmware Update\nNote:\nFollowing are the Firmware update methods and components supported in this page.\n• Dual Firmware update.\n• HPM Firmware update supports the following components.\n○ BOOT and APP\n○ BIOS\n• BIOS Firmware update\nSelect Firmware Image\nStart firmware update\nProtocol Type: HTTPS\nThe dual image formation to be used for firmware update is displayed as follows. To configure Image to be booted from upon\nReset, choose 'Dual image Configuration' under Maintenance.\nCurrent Active Image Image-1\nImage to be Updated\nInactive Image\nPreserve all Configuration. This will preserve all the configuration settings during the firmware update - irrespective of\nthe Individual Items marked as preserve/overwrite in the table below.\nAll configuration items below will be preserved as default during the restore configuration operation. Click 'Edit Preserve\nConfiguration' to modify the Preserve status settings.\nEdit Preserve Configuration\nS.No Preserve Configuration Item Preserve Status\n1 SDR Overwrite\n2 FRU Overwrite\n3 SEL Overwrite\n4 IPMI Overwrite\n5 NETWORK Overwrite\n6 NTP Overwrite\n7 SNMP Overwrite\n8 SSH Overwrite\n9 KVM Overwrite\n10 AUTHENTICATION Overwrite\n11 SYSLOG Overwrite\n12 WEB Overwrite\n13 EXTLOG Overwrite\n14 REDFISH Overwrite\nProceed to Flash\nWARNING:Please note that after entering the update mode, the widgets, other web pages and services will not work. All the open\nwidgets will be automatically closed. If the upgrading is cancelled in the middle of the wizard, the device will be reset only for BMC\nBOOT,and APP components of Firmware.](.axe-7420gwa-50m-22811-1000-02/f386a8cd268155112ca8088ad398b6c27711356dcf9ead36d852656fbbaeb0b9.jpg)

3. Select an Image (Inactive Image, Image 1, Image 2 or Both Image) from Image to be Updated drop-down list. The selected image will be getting flashed.

• Image to be Updated: To update an Image (Inactive, Image 1, Image 2 or Both) to be flashed. If You select an Inactive image, the Inactive image will be flashed. If you select both images, then Both Image 1 and Image 2 will be flashed with uploaded image file.
• reboot the device after update: This option is used to reboot the device after the firmware update.

![Protocol Type: HTTPS\nThe dual image formation to be used for firmware update is displayed as follows. To configure Image to be booted from upon Reset, choose 'Dual Image Configuration' under Maintenance.\nCurrent Active Image Image-1\nImage to be Updated\nInactive Image\nInactive Image\nImage 1\nImage 2\nBoth Images](.axe-7420gwa-50m-22811-1000-02/f20d42fc8e4e36711a36fab0adea1bb38bcf9467616306d48f32a2f12d30c937.jpg)

4. Click Preserve all Configuration to preserve all configuration.

• Preserve all Configuration: To preserve all configuration.
• Edit Preserve Configuration: To modify the Preserve status settings.

5. Click Proceed to Flash, it will prompt you with the warning message. Click Ok to start the Firmware update.

# The Dual Firmware Update undergoes the following steps:

a) Closing all active client requests
b) Preparing Device for Firmware Upgrade
c) Uploading Firmware Image
d) Verifying Firmware Image:

In Section Based Firmware Update, you can configure the firmware image for section-based flashing. Check the required sections and click Proceed to update the firmware.
If flashing is required for all images, select the option Full Flash.
If you select Version Compare Flash option from web, the current and uploaded module versions, FMHlocation, size will be compared.
If the modules differ in size and location, proceed with force firmware upgrade.
If all the module versions are same, restart BMC by saying all the module versions are similar.
If only a few module versions differ, those modules will be flashed.

Section Based Firmware Update
The following section is used to allow the user to configure the firmware image for section based flashing.

<table><tr><td colspan="3">□ Version Compare Flash</td><td colspan="2">□ Full Flash</td></tr><tr><td>Section Name</td><td>Image-1 Version</td><td>Image-2 Version</td><td>Uploaded version</td><td>Upgradable/Non-Upgradable</td></tr><tr><td>boot</td><td>13.5.000000</td><td>13.5.000000</td><td>13.5.000000</td><td></td></tr><tr><td>conf</td><td>13.5.000000</td><td>13.5.000000</td><td>13.5.000000</td><td></td></tr><tr><td>root</td><td>13.5.000000</td><td>13.5.000000</td><td>13.5.000000</td><td></td></tr><tr><td>osimage</td><td>13.5.000000</td><td>13.5.000000</td><td>13.5.000000</td><td></td></tr><tr><td>www</td><td>13.5.000000</td><td>13.5.000000</td><td>13.5.000000</td><td></td></tr><tr><td>extlog</td><td>13.5.000000</td><td>13.5.000000</td><td>13.5.000000</td><td></td></tr><tr><td>extlog</td><td>13.5.000000</td><td>0.0.</td><td>13.5.000000</td><td></td></tr><tr><td>bootlogo</td><td>1.0.000000</td><td>1.0.000000</td><td>1.0.000000</td><td></td></tr><tr><td>arcity</td><td>13.5.010003</td><td>13.5.010002</td><td>13.5.010003</td><td></td></tr></table>

e) Flashing Firmware Image
f) Resetting the image

# BIOS Update

This wizard takes you through the process of BIOS firmware upgradation.

To perform BIOS Firmware Update operation, click Maintenance > Firmware Update.

# Firmware Update

![Note:\nFollowing are the Firmware update methods and components supported in this page.\n• Dual Firmware update.\n• HPM Firmware update supports the following components.\n    ○ BOOT and APP\n    ○ BIOS\n• BIOS Firmware update.\n\nSelect Firmware Image\nMECS-7120_1110.BIN\n\nStart firmware update\n\nPreparing to flash...\n\nProceed\n\nWARNING: Please note that after entering the update mode, the widgets, other web pages and services will not work. All the open widgets will be automatically closed. If the upgradation is cancelled in the middle of the wizard, the device will be reset only for BMC BOOT, and APP components of Firmware.](.axe-7420gwa-50m-22811-1000-02/953277e6a67da31282510cd9acbf061d309adfb0a04f5ca98c2bf8b616e422b4.jpg)

# Procedure

1. Click Browse to select BIOS Firmware Image.
Note: Firmware update wizard will detect .bin and .bin\_enc extensions, and validate as BIOS firmware image.
2. Click Start firmware update to load the BIOS firmware image information.
3. Click Proceed, it will prompt you with the warning message. Click OK to start the firmware update.

172.20.2.12 says

Are you sure you want to flash?

![This image shows a pair of buttons. On the left is a blue button with the text 'OK' in white. On the right is a white button with the text 'Cancel' in black.](.axe-7420gwa-50m-22811-1000-02/def270e141c49acd1e3fc9f60575993167045e260bd111cff600518bbcc32edb.jpg)

4. Select the components from the list to flash. BIOS is mandatory, ME and NVRAM are optional.

Firmware Update

![Note:\nFollowing are the Firmware update methods and components supported in this page.\n• Dual Firmware update.\n• HPM Firmware update supports the following components.\n    ○ BOOT and APP\n    ○ BIOS\n• BIOS Firmware update.\n\nSelect Firmware Image\nMECS-7120_1110.BIN\n\nStart firmware update\n\nPreparing to flash...\n\nList of Components\n# Component Name Existing Version Uploaded Version Upgrade Progress\n1 BIOS 2280811 In progress...\n2 ME \n3 NVRAM \n\nProceed to flash image Cancel\n\nUploading 100%\n\nWARNING: Please note that after entering the update mode, the widgets, other web pages and services will not work. All the open widgets will be automatically closed. If the upgrading is cancelled in the middle of the wizard, the device will be reset only for BMC BOOT, and APP components of Firmware.](.axe-7420gwa-50m-22811-1000-02/09bfa4161001fd74aec3fded45c222eaf83ebb5b9d0bafbdbf945a7a508a1f07.jpg)

5. Click Proceed to flash image, it will prompt you with the selection message. Click Cancel, the update will be cancelled.

# 172.20.2.12 says

Are you sure the BlOS upgrade takes effect immediately? If yes, BMC will power off and power on the chassis after flash update. If no, the BlOS upgrade will take effect when the chassis is powered off.

OK

Cancel

Click OK: Update the device immediately, the chassis will be powered cycle. Once the BIOS firmware update is completed, it will prompt you with the success message. Click OK to complete the process.

# 172.20.2.12 says

The device has been updated successfully.

OK

Click Cancel: Update the device when the chassis is powered off. It will prompt you with the notification message. Click OK to complete the process.

# 172.20.2.12 says

The BlOS upgrade will take effect when the chassis is powered off.

OK

# 8.2.8.2.1 HPM Firmware Update – CPLD/BIOS

To perform HPM Firmware Update operation, click Maintenance > Firmware Update from the menu bar.

Note: For BIOS or CPLD firmware update, it is required to hash its uploaded image via creating HPM image utility.

# Create HPM Image

./CreateHPMImage create hpmimage.conf

CreateHPMImage is the creating HPM image utility from AMI.

# Sample of hpmimage.conf

```ini
[GLOBAL]
DeviceID = 0x20 ;1B Device ID as per IPMI
ManufacturerID = 0x005f13 ;3B Manufacturer ID as per IPMI
ProductID = 0x7120 ;2B Product ID
HPMImage = /home/bmc/outputjbc_02b4.hpm ;Path & Filename of final output HPM Image
[CPLD] ;Component Type: BIOS, CPLD
UpgradeActionType = 0x02 ;1B Upgrade Action Type: 0x02 = Upload, 0x03 - 0xFF = Reserved
FwVersionMajor = 0x02 ;1B This component's Major Version
FwVersionMinor = 0x04 ;1B This component's Minor Version
FwVersionAux = 0x02200000 ;4B This component's Aux Version
FwDescription = "cpld" ;21B Firmware Description String to be used
FwData = /home/bmc/cpld_02b4.jbc ;Path & Filename of Component's Image
SectionFlash = 0x0 ;For Section based flashing of the particular component 0 - disabled 1 - enabled
```

Note: The CPLD Image should be a .jbc file and enable the option "Enable real-time ISP to allow background programming when available".

☑ Enable real-time ISP to allow background programming when available

# Procedure for CPLD Firmware Update

1. Select HPM format of CPLD supported image to perform the CPLD Firmware Update.
2. Click Start firmware update to load the Firmware Update information. Once the image is successfully uploaded, the uploaded image information such as Component Name, Existing Version, Uploaded Version and Upgrade will be displayed as shown in the screenshot below. In addition, all the CPLD devices information such as Name, Interface, Interface Number, ID code and Firmware Version will be displayed as well. User can select the device that needs to be updated.

Select Firmware Image

outputjbc\_02b4.hpm

![A low-resolution, cropped image featuring a blurry white shape resembling the letter 'F' or a flag icon set against a solid blue background.](.axe-7420gwa-50m-22811-1000-02/8d05599b9b18ee1f94eada1d37273f951624039a56e564a7f96695d0de145bfd.jpg)

Start firmware update

![The image displays a close-up of a blue square icon containing a white checkmark in the center. It appears to be a selected checkbox interface element. The image is cropped on the left side and shows some pixelation. There is no text present.](.axe-7420gwa-50m-22811-1000-02/267a42cfc1a4a3bcf440a6b25b24eced2d7e789e48eaf538d256d3c966edcf68.jpg)

List of Components

<table><tr><td>#</td><td>Component Name</td><td>Existing Version</td><td>Uploaded Version</td><td>Upgrade</td></tr><tr><td>1</td><td>CPLD</td><td>0.0.0</td><td>2.4.35651584</td><td></td></tr></table>

List of CPLD devices

<table><tr><td>Name</td><td>Interface</td><td>Interface Number</td><td>ID Code</td><td>Firmware Version</td></tr><tr><td>ALTERA 10M50DA CPLD</td><td>JTAG</td><td>0x0</td><td>0x31050dd</td><td>0x65bba5</td></tr><tr><td>Proceed</td><td></td><td></td><td></td><td></td></tr></table>

3. Click Proceed, it will prompt you with the warning message. Click OK to start the firmware update.

172.20.2.18 says

Are you sure you want to flash?

OK

Cancel

If a CPLD firmware has been uploaded, it will prompt you with the selection message. Click Cancel, the update will be cancelled.

172.20.2.18 says

A new firmware has been upload. Are you sure to force update?

OK

Cancel

# A sample screenshot is shown below:

![Note:\nFollowing are the Firmware update methods and components supported in this page.\n• Dual Firmware update.\n• HPM Firmware update supports the following components.\n    ○ BOOT and APP\n    ○ BIOS\n    ○ CPLD\n• BIOS Firmware update\n\nSelect Firmware Image\noutputjbc_02b4.hpm\n\nStart firmware update\n\nPreparing to flash...\n\nUpdate All\n\nList of Components\n# Component Name Existing Version Uploaded Version Upgrade Progress\n1 CPLD 0.0.0 2.4.35651584 In progress...\n\nList of CPLD devices\nName Interface Interface Number ID Code Firmware Version\nALTERA 10M50DA CPLD JTAG 0x0 0x31050dd 0x65bba5\nProceed\n\nUpgrade (50%)](.axe-7420gwa-50m-22811-1000-02/2049d35b5820399c44ca59b2185372401d767399dbebc14f0b8a066d2415020d.jpg)

4. Once the CPLD Firmware Update process is completed, an alert message will be displayed as shown in the screenshot below.

172.20.2.18 says

The device has been updated successfully.

OK

# Firmware Configuration

# 8.2.8.3.1 Dual Image Configuration

This page is used to configure the dual image information. Dual Image support feature is helpful to store two firmware images on two SPI flash, and boot any of the image according to users request.

The running firmware is responsible for setting the Boot Selector options and Firmware Upload Selector options.

To open Dual Image Configuration, click Maintenance > Dual Image Configuration from the menu bar. A sample screenshot of Dual Image Configuration page is shown below.

![Dual Image configuration\nIMAGE 1\nFirmware Version 13.05.10003\nState Active\n✓ Image to be booted from upon reset\nIMAGE 2\nFirmware Version 13.05.10002\nState stand-by\n○ Image to be booted from upon reset\n○ Higher firmware version\n○ Lower firmware version\n○ Most recently updated firmware\n○ Least recently updated firmware\nSave](.axe-7420gwa-50m-22811-1000-02/730de5ff9144c7d35acd08786c4a357564d66eb8f2fa24443e024a83c7168ed0.jpg)

The various options of Dual Image Configuration are given below.

Firmware Version: Displays the firmware version of both images.

State: Displays the current state of both images.

Image to be booted from upon reset: This option is to boot particular image (either 1 or 2) in the next boot up process.

Higher firmware version: This option is to boot higher firmware version image among the dual images in the next boot up process.

Lower firmware version: This option is to boot lower firmware version image among the dual images in the next boot up process.

Most recently updated firmware: This option is to boot most recently updated firmware image among the dual images in the next boot up process.

Least recently updated firmware: This option is to boot least recently updated firmware image among the dual images in the next boot up process.

# Procedure

1. Select the required image to be configured or the required option for Image setting.
2. Click Save to save the changes.

# Fail Safe Booting Configuration:

Hardware based fail safe boot support: This feature supports switching to secondary image as failsafe using hardware configurations. Using this feature, the user can boot into secondary image, even though primary uboot is crashed. Please verify whether SOC supports this feature.

Software FailSafe Boot: Legacy AMI dual image support. This feature uses common UBOOT which switches between 2 different images based on user requirement. This feature does not requires a special hardware support.

# One-Click Log Collection

The One-Click Log Collection feature enables users to download essential BMC information data for detailed analysis of BMC status or issue identification.

To open the One-Click Log Collection, click One-click Log collection from the menu bar. A sample screenshot of Event Log page is shown below.

One-click Log Collection

![The image displays a bright green rectangular button. On the left side is a white icon depicting a downward-pointing arrow above a horizontal line. To the right of the icon is the white text 'Download' in a sans-serif font.](.axe-7420gwa-50m-22811-1000-02/316cf47457f929795af1aeffc2f7fb2030667ff87be9c745e3d36362c2e27039.jpg)

Click the "Download" button to automatically download the Log to the system.

The log package is named：

One-Click\_Collection\_Log\_[time].zip

Inside the zip file, you will find the following folders:

• conf: Configuration files
• tmp: Temporary files
• var: Variable files

# Firmware and Hardware versions

To get the version info of BMC, BIOS, CPLD and hardware, please refer to home page, up-left corner.

For example:

![MECS-7120\nVersion Information\nBMC: 1.4.dd360de7\nBIOS: 1.2.10\nCPLD: 02b4\nHW: A2 SKU: 1U\nMar 15 2024 05:58:02 UTC\nHost Online](.axe-7420gwa-50m-22811-1000-02/4a79ae1ce7a1fdf085a86e89b5e8dc261cb0be249cd30d733a2ecc1ba86aacc8.jpg)

# 8.3 IPMI

Intelligent Platform Management Interface (IPMI) is a standardized interface used for managing a computer system and monitoring its operation. It provides a set of specifications for hardware-based management, independent of the operating system.

# Overview of ipmitool

The ipmitool is a command-line utility that interfaces with the IPMI system. It allows administrators to execute a range of IPMI commands to manage and monitor servers. This tool is essential for system management, providing an interface to the IPMI functionalities of the server's BMC.

# General Usage of ipmitool

The ipmitool allows for a range of operations through its command-line interface. The general syntax includes various parameters for network communication and authentication.

Common Parameters:

-H or --hostname: Hostname or IP address of the target server (for network interfaces).

-U or --user: Username for login.

-P or --password: Password for login (it's recommended to input interactively for security).

<table><tr><td>Parameter</td><td>Alias</td><td>Description</td></tr><tr><td>-H</td><td>--hostname</td><td>Hostname or IP address of the target server (for network interfaces).</td></tr><tr><td>-U</td><td>--user</td><td>Username for login.</td></tr><tr><td>-P</td><td>--password</td><td>Password for login (recommended to be input interactively for security).</td></tr></table>

# Specific Interface Options

# LAN Interface (lan)

Usage: ipmitool -I lan -H [hostname] -U [username] -P [password] [command]

Note: The LAN interface is suitable for local communication with IPMI. For remote management capabilities, the LANplus interface should be used.

# Example:

![~ # ipmitool -I lan -H 127.0.0.1 -U admin -P admin.123 mc info\nIOCTL to get IP failed: -1\nDevice ID : 32\nDevice Revision : 1\nFirmware Revision : 1.03\nIPMI Version : 2.0\nManufacturer ID : 24339\nManufacturer Name : ADLINK Technology Inc.\nProduct ID : 28960 (0x7120)\nProduct Name : Unknown (0x7120)\nDevice Available : yes\nProvides Device SDRs : yes\nAdditional Device Support :\nSensor Device\nSDR Repository Device\nSEL Device\nFRU Inventory Device\nIPMB Event Receiver\nIPMB Event Generator\nChassis Device\nAux Firmware Rev Info :\n0x11\n0x0d\n0x10\n0xb9](.axe-7420gwa-50m-22811-1000-02/283440f27285650cc0efcf3d6b29508eabc374a5699c071c48cc11a3a16f3f47.jpg)

# LANplus Interface (lanplus)

Usage: ipmitool -I lanplus -H [hostname] -U [username] -P [password] [command]

Enhanced LAN interface with better encryption and additional features for secure remote communication.

# Example:

```txt
root@adlink-Default-string:/home/adlink# ipmitool -I lanplus -H 172.20.2.137 -U admin -P admin.123 mc info
Device ID : 32
Device Revision : 1
Firmware Revision : 1.03
IPMI Version : 2.0
Manufacturer ID : 24339
Manufacturer Name : ADLINK Technology Inc.
Product ID : 28960 (0x7120)
Product Name : Unknown (0x7120)
Device Available : yes
Provides Device SDRs : yes
Additional Device Support :
Sensor Device
SDR Repository Device
SEL Device
FRU Inventory Device
IPMB Event Receiver
IPMB Event Generator
Chassis Device
Aux Firmware Rev Info :
0x11
0x0d
0x10
0xb9
```

# KCS Interface (kcs)

Usage: ipmitool [command]

KCS (Keyboard Controller Style) is used for communication between the x86 segment and the BMC directly, without needing the -I parameter. It's used for local, direct communication with BMC.

# Example:

```txt
root@adlink-Default-string:/home/adlink#
root@adlink-Default-string:/home/adlink# ipmitool mc info
Device ID : 32
Device Revision : 1
Firmware Revision : 1.03
IPMI Version : 2.0
Manufacturer ID : 24339
Manufacturer Name : ADLINK Technology Inc.
Product ID : 28960 (0x7120)
Product Name : Unknown (0x7120)
Device Available : yes
Provides Device SDRs : yes
Additional Device Support :
Sensor Device
SDR Repository Device
SEL Device
FRU Inventory Device
IPMB Event Receiver
IPMB Event Generator
Chassis Device
Aux Firmware Rev Info :
0x11
0x0d
0x10
0xb9
root@adlink-Default-string:/home/adlink#
```

# ipmitool Command Introduction

This section is dedicated to introducing and explaining a variety of ipmitool commands, with detailed descriptions of their specific uses.

# Sensor Information

The ipmitool command is used to retrieve sensor information, allowing system users to monitor various hardware sensors within the server. These sensors can include temperature, voltage, fan speed, and other key operating metrics.

List sensor information using ipmitool command:

# Command:

ipmitool sensor

ipmitool sensor list

Return Details:

<table><tr><td>Return Details</td><td>Description</td></tr><tr><td>Sensor Name</td><td>Identifies the sensor.</td></tr><tr><td>Reading</td><td>The current value or status reported by the sensor.</td></tr><tr><td>Units</td><td>The measurement units for the sensor reading.</td></tr><tr><td>Status</td><td>Indicates the operational status of the sensor.</td></tr><tr><td>Lower/Upper Thresholds</td><td>The predefined limits for the sensor values, indicating warning or critical conditions.</td></tr></table>

Example:

<table><tr><td colspan="10">root@adlink-Default-string:/home/adlink# ipmitool sensor list</td></tr><tr><td>P12V_PSU</td><td>12.230</td><td>Volts</td><td>ok</td><td>10.800</td><td>11.160</td><td>11.400</td><td>12.600</td><td>12.840</td><td>13.200</td></tr><tr><td>P12V_AUX</td><td>12.200</td><td>Volts</td><td>ok</td><td>10.800</td><td>11.160</td><td>11.400</td><td>12.600</td><td>12.840</td><td>13.200</td></tr><tr><td>P3V3</td><td>3.315</td><td>Volts</td><td>ok</td><td>2.970</td><td>3.069</td><td>3.135</td><td>3.465</td><td>3.531</td><td>3.630</td></tr><tr><td>P5V</td><td>5.120</td><td>Volts</td><td>ok</td><td>4.500</td><td>4.650</td><td>4.750</td><td>5.250</td><td>5.350</td><td>5.500</td></tr><tr><td>PVNN_PCH_AUX</td><td>0.905</td><td>Volts</td><td>ok</td><td>0.810</td><td>0.837</td><td>0.855</td><td>0.941</td><td>0.963</td><td>0.990</td></tr><tr><td>P1V05_PCH_AUX</td><td>1.057</td><td>Volts</td><td>ok</td><td>0.945</td><td>0.977</td><td>0.998</td><td>1.082</td><td>1.124</td><td>1.155</td></tr><tr><td>P1V8_AUX</td><td>1.816</td><td>Volts</td><td>ok</td><td>1.620</td><td>1.674</td><td>1.728</td><td>1.864</td><td>1.926</td><td>1.980</td></tr><tr><td>P3V_BAT</td><td>2.998</td><td>Volts</td><td>ok</td><td>2.002</td><td>2.302</td><td>2.500</td><td>3.148</td><td>3.208</td><td>3.298</td></tr><tr><td>PVCCIN_CPU</td><td>1.813</td><td>Volts</td><td>ok</td><td>1.441</td><td>1.489</td><td>1.519</td><td>1.891</td><td>1.927</td><td>1.981</td></tr><tr><td>POV8_E810</td><td>0.822</td><td>Volts</td><td>ok</td><td>0.720</td><td>0.744</td><td>0.760</td><td>na</td><td>na</td><td>0.880</td></tr><tr><td>PVCCINFAON</td><td>1.090</td><td>Volts</td><td>ok</td><td>0.856</td><td>0.900</td><td>0.930</td><td>1.130</td><td>1.150</td><td>1.180</td></tr><tr><td>P3V3_AUX</td><td>3.300</td><td>Volts</td><td>ok</td><td>2.970</td><td>3.069</td><td>3.135</td><td>3.465</td><td>3.531</td><td>3.630</td></tr><tr><td>PVCCFA_EHV_FIVRA</td><td>1.812</td><td>Volts</td><td>ok</td><td>1.620</td><td>1.674</td><td>1.710</td><td>1.890</td><td>1.926</td><td>1.980</td></tr><tr><td>POV9_E810</td><td>0.888</td><td>Volts</td><td>ok</td><td>0.810</td><td>0.837</td><td>0.855</td><td>0.945</td><td>0.963</td><td>0.990</td></tr><tr><td>PVCCD_HV</td><td>1.124</td><td>Volts</td><td>ok</td><td>0.990</td><td>1.030</td><td>1.050</td><td>1.192</td><td>1.220</td><td>1.270</td></tr><tr><td>P12V_S3_DIMM</td><td>12.060</td><td>Volts</td><td>ok</td><td>10.800</td><td>11.160</td><td>11.400</td><td>12.600</td><td>12.840</td><td>13.200</td></tr><tr><td>PCIE_Outlet_Temp</td><td>27.000</td><td>degrees C</td><td>ok</td><td>na</td><td>na</td><td>na</td><td>55.000</td><td>60.000</td><td>65.000</td></tr><tr><td>CPU_Outlet_Temp</td><td>33.000</td><td>degrees C</td><td>ok</td><td>na</td><td>na</td><td>na</td><td>na</td><td>na</td><td>na</td></tr><tr><td>SYS_Inlet_Temp</td><td>28.000</td><td>degrees C</td><td>ok</td><td>na</td><td>na</td><td>na</td><td>na</td><td>na</td><td>na</td></tr><tr><td>HDD_BP_Temp</td><td>22.000</td><td>degrees C</td><td>ok</td><td>na</td><td>na</td><td>na</td><td>47.000</td><td>51.000</td><td>55.000</td></tr><tr><td>CPU_Temp</td><td>37.000</td><td>degrees C</td><td>ok</td><td>na</td><td>na</td><td>na</td><td>91.000</td><td>95.000</td><td>99.000</td></tr><tr><td>CPU_TJMAX</td><td>97.000</td><td>degrees C</td><td>ok</td><td>na</td><td>na</td><td>na</td><td>na</td><td>na</td><td>na</td></tr><tr><td>PCH_Temp</td><td>31.000</td><td>degrees C</td><td>ok</td><td>na</td><td>na</td><td>na</td><td>na</td><td>na</td><td>na</td></tr><tr><td>DIMM_A1_Temp</td><td>na</td><td>degrees C</td><td>na</td><td>na</td><td>na</td><td>na</td><td>106.000</td><td>116.000</td><td>125.000</td></tr><tr><td>DIMM_B1_Temp</td><td>na</td><td>degrees C</td><td>na</td><td>na</td><td>na</td><td>na</td><td>106.000</td><td>116.000</td><td>125.000</td></tr><tr><td>DIMM_C1_Temp</td><td>na</td><td>degrees C</td><td>na</td><td>na</td><td>na</td><td>na</td><td>106.000</td><td>116.000</td><td>125.000</td></tr><tr><td>DIMM_E1_Temp</td><td>31.000</td><td>degrees C</td><td>ok</td><td>na</td><td>na</td><td>na</td><td>106.000</td><td>116.000</td><td>125.000</td></tr><tr><td>DIMM_G1_Temp</td><td>na</td><td>degrees C</td><td>na</td><td>na</td><td>na</td><td>na</td><td>106.000</td><td>116.000</td><td>125.000</td></tr><tr><td>DIMM_H1_Temp</td><td>na</td><td>degrees C</td><td>na</td><td>na</td><td>na</td><td>na</td><td>106.000</td><td>116.000</td><td>125.000</td></tr><tr><td>ACPI_Power</td><td>0x0</td><td>discrete</td><td>0x0180</td><td>na</td><td>na</td><td>na</td><td>na</td><td>na</td><td>na</td></tr></table>

# Other ipmitool Commands Related to Sensor Information

Below is a table summarizing additional ipmitool commands pertinent to sensor management and monitoring:

# Power Control

Using ipmitool commands, you can effectively control the power mode.

# 8.3.2.2.1 Power Control Method

Using ipmitool command, it can control the power, such as power on, power off, power cycle, power reset.

# Command:

```typescript
ipmitool power &lt;on | off | cycle | reset&gt;
```

<table><tr><td>Command Element</td><td>Description</td></tr><tr><td>ipmitool power on</td><td>Power on the chassis.</td></tr><tr><td>ipmitool power off</td><td>Power off the chassis.</td></tr><tr><td>ipmitool power cycle</td><td>Power off the chassis and power on the chassis.</td></tr><tr><td>ipmitool power reset</td><td>Restart the chassis.</td></tr></table>

# Example:

```txt
root@bmc:/# ipmitool power on
Chassis Power Control: Up/On

root@bmc:/# ipmitool power off
Chassis Power Control: Down/Off

root@bmc:/# ipmitool power cycle
Chassis Power Control: Cycle

root@bmc:/# ipmitool power reset
Chassis Power Control: Reset
```

# Network Configuration

# 8.3.2.3.1 Get the current configuration of the management port

ipmitool lan print [&lt;channel number&gt;]

Note: To determine on which channel the LAN interface is located, issue the 'ipmitool channel info number' command until you come across a valid 802.3 LAN channel.

Example:
```yaml
root@bmc:/# ipmitool lan print 8
Set in Progress : Set Complete
Auth Type Support :
Auth Type Enable : Callback :
: User :
: Operator :
: Admin :
: OEM :
IP Address Source : DHCP Address
IP Address : 192.168.1.12
Subnet Mask : 255.255.255.0
MAC Address : 00:30:64:a8:7b:04
SNMP Community String : AMI
IP Header : TTL=0x40 Flags=0x40 Precedence=0x00 TOS=0x10
BMC ARP Control : ARP Responses Enabled, Gratuitous ARP Disabled
Gratituous ARP Intrvl : 1.0 seconds
Default Gateway IP : 192.168.1.1
Default Gateway MAC : 50:7b:9d:25:56:a1
Backup Gateway IP : 0.0.0.0
Backup Gateway MAC : 00:00:00:00:00:00
802.1q VLAN ID : Disabled
802.1q VLAN Priority : 0
RMCP+ Cipher Suites : 3,17
Cipher Suite Priv Max : XXXaXXXXXXXXaXXX
: X=Cipher Suite Unused
: c=CALLBACK
: u=USER
: o=OPERATOR
: a=ADMIN
: O=OEM
Bad Password Threshold : 0
Invalid password disable: no
Attempt Count Reset Int.: 0
User Lockout Interval : 0
```

# 8.3.2.3.2 Set the IP address source

ipmitool lan set &lt;channel number&gt; ipsrc &lt;source&gt;

source:
```yaml
- static: manually configured static IP address
- dhcp: address obtained by BMC running DHCP
```

# 8.3.2.3.3 Set the IP Address

```txt
ipmitool lan set &lt;channel number&gt; ipaddr &lt;x.x.x.x&gt;
```

# Example:

```batch
root@bmc:/# ipmitool lan set 8 ipaddr 192.168.1.100
```

```txt
Setting LAN IP Address to 192.168.1.100
```

# 8.3.2.3.4 Set the Netmask

```txt
ipmitool lan set &lt;channel number&gt; netmask &lt;x.x.x.x&gt;
```

# 8.3.2.3.5 Set the Default Gateway IP Address

```txt
ipmitool lan set &lt;channel number&gt; defqw ipaddr &lt;x.x.x.x&gt;
```

Note: Make sure the gateway IP address is pingable.

# 8.3.2.3.6 Set Network Configuration via BIOS

Enter BIOS Setup > Server Mgmt > BMC network configuration.

Aptio Setup - AMI
Server Mgmt
```txt
--BMC network configuration--
^|Select to configure LAN ^
* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *
* |channel parameters    *
Configure IPv4 support
* |statically or    *
* * * * * * * * * * * * * * * * * * * * * *
+|BMC). Unspecified    *
Lan channel 1
+|option will not modify   *
Configuration Address    [Unspecified]    +|any BMC network    +
Current Configuration    DynamicAddressBmcDhcp    +|parameters during BIOS v|
Station IP address    0.0.0.0    +|
Subnet mask    0.0.0.0    +|----
Station MAC address    00-30-64-66-77-88    +|>&lt;: Select Screen    |
Router IP address    0.0.0.0    +|^v: Select Item    |
Router MAC address    00-00-00-00-00-00    +|Enter: Select    |
Lan channel 2
+|+/-: Change Opt.    |
Configuration Address    [Unspecified]    +|F1: General Help    |
Current Configuration    DynamicAddressBmcDhcp    +|F8: Previous Values    |
Station IP address    192.168.1.12    +|F9: Optimized Defaults    |
|ESC: Exit    |
```
Version 2.22.1289 Copyright (C) 2024 AMI

Aptio Setup - AMI

Server Mgmt

&lt;table&gt;<tr><td colspan="2">--BMC network configuration--</td><td>^|Select to configure LAN ^|</td></tr><tr><td colspan="2">***************</td><td>*|channel parameters *|</td></tr><tr><td colspan="2">Configure IPv4 support</td><td>*|statically or *|</td></tr><tr><td colspan="2">***************</td><td>*|dynamically(by BIOS or *|</td></tr><tr><td colspan="2"></td><td>+|BMC). Unspecified *|</td></tr><tr><td colspan="2">Lan channel 1</td><td>+|option will not modify *|</td></tr><tr><td>Configuration Address</td><td>[Static]</td><td>+|any BMC network +|</td></tr><tr><td>Station IP address</td><td>188.188.1.2</td><td>+|parameters during BIOS v|</td></tr><tr><td>Subnet mask</td><td>255.255.255.0</td><td>+|</td></tr><tr><td>Station MAC address</td><td>00-30-64-66-77-88</td><td>+|----|</td></tr><tr><td>Router IP address</td><td>188.188.1.1</td><td>+|&gt;&lt;: Select Screen |</td></tr><tr><td>Router MAC address</td><td>00-00-00-00-00-00</td><td>+|^v: Select Item |</td></tr><tr><td colspan="2"></td><td>+|Enter: Select |</td></tr><tr><td colspan="2">Lan channel 2</td><td>+|+/-: Change Opt. |</td></tr><tr><td>Configuration Address</td><td>[Unspecified]</td><td>+|F1: General Help |</td></tr><tr><td>Current Configuration</td><td>DynamicAddressBmcDhcp</td><td>+|F8: Previous Values |</td></tr><tr><td>Station IP address</td><td>192.168.1.12</td><td>+|F9: Optimized Defaults |</td></tr><tr><td>Subnet mask</td><td>255.255.255.0</td><td>v|F10: Save &amp; Exit |</td></tr><tr><td colspan="2"></td><td>|ESC: Exit |</td></tr></table>

Version 2.22.1289 Copyright (C) 2024 AMI

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>Configuration Address source</td><td>StaticDynamicBmcDhcp</td><td>Set the IP address source</td></tr><tr><td>Station IP address</td><td>x.x.x.x</td><td>Set the IP address</td></tr><tr><td>Subnet mask</td><td>x.x.x.x</td><td>Set the netmask</td></tr><tr><td>Router IP address</td><td>x.x.x.x</td><td>Set the default gateway IP address</td></tr><tr><td>Router MAC address</td><td>xx:xx:xx:xx:xx:xx</td><td>Set the default gateway MAC address</td></tr></table>

# SOL

The serial over LAN (SOL) feature is very useful, and the SOL redirects the local serial interface via an IPMI session, allowing remote access to the console.

Open SOL functionality using ipmitool command:

# Command:

ipmitool sol activate

# Example:

<table><tr><td colspan="3">Main Advanced Platform Configuration Socket Configuration Server Mgmt &gt;</td></tr><tr><td>BIOS Information</td><td></td><td>|Set the Date|</td></tr><tr><td>BIOS Vendor</td><td>American Megatrends</td><td>|switch betwe|</td></tr><tr><td>BIOS Version</td><td>1.2.10</td><td>|Default Rang|</td></tr><tr><td>Build Date</td><td>01/24/2024</td><td>|Year: 1998-9|</td></tr><tr><td>RC Version</td><td>370.P03</td><td>|Months: 1-12|</td></tr><tr><td>SPS FW Version</td><td>6.1.2.48</td><td>|Days: Depend|</td></tr><tr><td></td><td></td><td>|Range of Yea|</td></tr><tr><td>System Information</td><td></td><td></td></tr><tr><td>Project Name</td><td>MECS-7120</td><td></td></tr><tr><td>CPU Board Version</td><td>/---- Save &amp; Exit ----\</td><td></td></tr><tr><td>CPU Brand String</td><td></td><td></td></tr><tr><td></td><td>| Quit without saving? |</td><td></td></tr><tr><td>CPU Frequency</td><td></td><td></td></tr><tr><td>Total Memory</td><td></td><td>|&lt;&lt;: Select S</td></tr><tr><td>Memory Frequency</td><td>Yes No |</td><td>|^v: Select I</td></tr><tr><td>PCH SKU</td><td></td><td>|Enter: Selec|</td></tr><tr><td></td><td></td><td>+/-: Change</td></tr><tr><td>System Date</td><td>[Fri 01/26/2024]</td><td>|F1: General</td></tr><tr><td>System Time</td><td>[03:01:19]</td><td>|F8: Previous|</td></tr><tr><td></td><td></td><td>|F9: Optimize|</td></tr><tr><td>Access Level</td><td>Administrator</td><td>|F10: Save &amp;</td></tr><tr><td></td><td></td><td>|ESC: Exit|</td></tr><tr><td></td><td></td><td></td></tr><tr><td></td><td></td><td></td></tr><tr><td></td><td></td><td></td></tr><tr><td></td><td></td><td></td></tr><tr><td></td><td></td><td></td></tr><tr><td></td><td></td><td></td></tr><tr><td></td><td></td><td></td></tr><tr><td></td><td></td><td></td></tr><tr><td></td><td></td><td></td></tr><tr><td></td><td></td><td></td></tr><tr><td></td><td></td><td></td></tr><tr><td></td><td></td><td></td></tr><tr><td></td><td></td><td></td></tr><tr><td></td><td></td><td></td></tr><tr><td></td><td></td><td></td></tr><tr><td></td><td></td><td></td></tr><tr><td></td><td></td><td></td></tr></table>

Enter the "ipmitool sol activate" command on CLI to enter the SOL output window, then enter the BIOS configuration interface, and the content of the BIOS field interface will be redirected to the local terminal, as shown in the above figure.

# Other ipmitool Commands Related to SOL

Below is a table summarizing additional ipmitool commands related to SOL:

<table><tr><td>Command Element</td><td>Description</td></tr><tr><td>ipmitool sol deactivate</td><td>Close SOL functionality</td></tr><tr><td>ipmitool sol info</td><td>Show SOL detailed information</td></tr><tr><td>ipmitool sol set &lt;set-in-progress | enabled | force-encryption | force-authentication | privilege-level | character-accumulate-level | character-send-threshold | retry-count | retry-interval | non-volatile-bit-rate | volatile-bit-rate&gt; &lt;value&gt;</td><td>Set SOL parameter value</td></tr><tr><td>ipmitool sol payload</td><td>Set SOL payload value</td></tr><tr><td>ipmitool sol looptest</td><td>SOL connection stress test</td></tr></table>

# BMC Information

To get the BMC information via ipmitool please refer to the following command:

```txt
ipmitool mc info
```

For example:
```txt
root@bmc:/# ipmitool mc info
Device ID : 32
Device Revision : 1
Firmware Revision : 1.03
IPMI Version : 2.0
Manufacturer ID : 24339
Manufacturer Name : ADLINK Technology Inc.
Product ID : 28960 (0x7120)
Product Name : Unknown (0x7120)
Device Available : yes
Provides Device SDRs : yes
Additional Device Support :
Sensor Device
SDR Repository Device
SEL Device
FRU Inventory Device
IPMB Event Receiver
IPMB Event Generator
Chassis Device
Aux Firmware Rev Info :
0x64
0x00
0x00
0x00
```

The full BMC version number is composed of the “Firmware Revision” and the “Aux Firmware Rev Info”. The Firmware Revision contains the major and minor version numbers. The Aux Firmware Rev Info contains the auxiliary version number, which is in little-endian format.

The full version number in the example above is as follows:

Major: 1

Minor: 3

Aux: 0x00000064 (hex) -> 100 (decimal)

# CPLD Update

```txt
ipmitool -z 0x3fff hpm upgrade &lt;hpm file&gt; component 5 force
```

Note: If a CPLD firmware has been uploaded, it will print "Firmware upgrade procedure failed".

# Example:

```batch
root@bmc:/# ipmitool -I lanplus -H 172.20.2.18 -U admin -P admin.123 -z 0x3fff hpm upgrade outputjbc_02b4.hpm component 5 force
```

```txt
Setting large buffer to 16383
```

```txt
PICMG HPM.1 Upgrade Agent 1.0.9:
```

```txt
Validating firmware image integrity...OK
```

```txt
Performing preparation stage...
```

```txt
Services may be affected during upgrade. Do you wish to continue? (y/n): y OK
```

```txt
Performing upgrade stage:
```

<table><tr><td>| ID | Name |</td><td colspan="3">Versions</td><td>| % |</td></tr><tr><td>| |</td><td>Active</td><td>Backup</td><td>| File</td><td>|</td></tr><tr><td>|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|---|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|--|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----| --|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----| ----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|-----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|------|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|--------------------|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|------------|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|****|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----------|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|mm|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|                |----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|----|
| * 5 | CPLD | 0.00 00000000 | ---.-- ---- | 2.04 00002002 | 100% | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
| | Upload Time: 00:00 | Image Size: 454924 bytes | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |</td><td></td><td></td><td></td><td></td></tr></table>

```ocaml
(*) Component requires Payload Cold Reset
```

```txt
Firmware upgrade procedure successful
```

# 8.4 Redfish

Redfish is a modern, RESTful API used for the management of servers, storage, and networking equipment in data centers and large-scale enterprise environments. It's designed to replace older, less efficient management interfaces with a standardized, scalable, and secure approach.

# Network Configuration

# GET - Ethernet Interface Collection

# Request:

```txt
GET https://{bmc ip}/redfish/v1/Managers/Self/EthernetInterfaces
```

# Response:

The response status is 200 OK.

# Example:

GET

![The image shows a narrow vertical section featuring a grey, downward-pointing chevron arrow centered horizontally. The arrow is situated within a white vertical band, flanked on either side by thin, darker vertical lines.](.axe-7420gwa-50m-22811-1000-02/84d9a9d202d107582492d29b7eaad556c36e211a46c4c9ea59d0c0a5e3c8b9ac.jpg)

```txt
https://172.20.2.12/redfish/v1/Managers/Self/EthernetInterfaces
```

```jsonl
{
    "@odata.context": "/redfish/v1/$metadata#EthernetInterfaceCollection.EthernetInterfaceCollection",
    "@odata.etag": "\"1705564980 Main",
    "@odata.id": "/redfish/v1/Managers/Self/EthernetInterfaces",
    "@odata.type": "#EthernetInterfaceCollection.EthernetInterfaceCollection",
    "Description": "Collection of Ethernet Interfaces for this Manager",
    "Members": [
    {
    "@odata.id": "/redfish/v1/Managers/Self/EthernetInterfaces/eth0"
    },
    {
    "@odata.id": "/redfish/v1/Managers/Self/EthernetInterfaces/eth1"
    },
    {
    "@odata.id": "/redfish/v1/Managers/Self/EthernetInterfaces/usb0"
    }
    ],
    "Members@odata.count": 3,
    "Name": "Ethernet Network Interface Collection"
}
```

# GET - Ethernet Interface Instance

# Request:

GET https://{{bmc ip}}/redfish/v1/Managers/Self/EthernetInterfaces/{{instance}}

# Response:

The response status is 200 OK. The format is JSON.

Ethernet Interface Properties:

<table><tr><td>Name</td><td>Type</td><td>Read Only</td><td>Description</td></tr><tr><td>AutoNeg</td><td>Boolean</td><td>×</td><td>Auto negotiation of speed and duplex on this interface is enabled or not.</td></tr><tr><td>DHCPv4</td><td>Object</td><td>×</td><td>Refer to DHCPv4 properties.</td></tr><tr><td>DHCPv6</td><td>Object</td><td>×</td><td>Refer to DHCPv6 properties.</td></tr><tr><td>Description</td><td>String</td><td>√</td><td></td></tr><tr><td>FullDuplex</td><td>Boolean</td><td>×</td><td>The value of this property shall represent the duplex status of the Ethernet connection on this interface.</td></tr><tr><td>HostName</td><td>String</td><td>×</td><td>DNS Hostname without any domain information.Maximum string size limit is 64.Minimum string size limit is 2.</td></tr><tr><td>IPv4Addresses</td><td>Array of Objects</td><td>√</td><td>Refer to IPv4 Address properties.</td></tr><tr><td>IPv4StaticAddresses</td><td>Array of Objects</td><td>×</td><td>Refer to IPv4 Address properties.</td></tr><tr><td>IPv6Addresses</td><td>Array of Objects</td><td>√</td><td>Refer to IPv6 Address properties.</td></tr><tr><td>IPv6StaticAddresses</td><td>Array of Objects</td><td>×</td><td>Refer to IPv6 Address properties.</td></tr><tr><td>IPv6DefaultGateway</td><td>String</td><td>√</td><td></td></tr><tr><td>Id</td><td>String</td><td>√</td><td></td></tr><tr><td>InterfaceEnabled</td><td>Boolean</td><td>×</td><td></td></tr><tr><td>LinkStatus</td><td>String</td><td>√</td><td></td></tr><tr><td>MACAddress</td><td>String</td><td>√</td><td></td></tr><tr><td>MTUSize</td><td>Number</td><td>×</td><td>Maximum size limit is 1500.Minimum size limit is 576.</td></tr><tr><td>MaxIPv6StaticAddresses</td><td>Number</td><td>√</td><td></td></tr><tr><td>Name</td><td>String</td><td>√</td><td></td></tr><tr><td>NameServers</td><td>Array of Strings</td><td>√</td><td></td></tr><tr><td>Oem</td><td>Object</td><td>√</td><td></td></tr><tr><td>PermanentMACAddress</td><td>String</td><td>√</td><td></td></tr><tr><td>SpeedMbps</td><td>Number</td><td>×</td><td>The current link speed of the interface in Mbps.</td></tr><tr><td>StatelessAddressAutoConfig</td><td>Object</td><td>×</td><td>This object shall contain the IPv4 and IPv6 Stateless Address Automatic Configuration (SLAAC) properties for this interface.</td></tr><tr><td>StaticNameServers</td><td>Array of Strings</td><td>×</td><td>Statically-defined set of DNS server IPv4 and IPv6 addresses.</td></tr><tr><td>Status</td><td>Object</td><td>√</td><td></td></tr><tr><td>VLAN</td><td>Object</td><td>×</td><td>VLANId: 0~4094.</td></tr></table>

DHCPv4 properties:

<table><tr><td>Name</td><td>Type</td><td>Read Only</td><td>Description</td></tr><tr><td>DHCPEnabled</td><td>Boolean</td><td>×</td><td>Determines whether DHCPv4 is enabled on this interface.</td></tr></table>

DHCPv6 properties:

<table><tr><td>Name</td><td>Type</td><td>Read Only</td><td>Description</td></tr><tr><td>OperatingMode</td><td>Boolean</td><td>×</td><td>This property shall control the operating mode of DHCPv6 on this interface. DHCPv6 stateful mode is used to configure addresses, and when it is enabled, stateless mode is also implicitly enabled.</td></tr></table>

IPv4 Address properties:

<table><tr><td>Name</td><td>Type</td><td>Read Only</td><td>Description</td></tr><tr><td>Address</td><td>String</td><td>-</td><td>IPv4 address.</td></tr><tr><td>AddressOrigin</td><td>String</td><td>-</td><td>IPv4 address source.</td></tr><tr><td>Gateway</td><td>String</td><td>-</td><td>IPv4 default gateway IP address.</td></tr><tr><td>SubnetMask</td><td>String</td><td>-</td><td>IPv4 netmask.</td></tr></table>

IPv6 Address properties:

<table><tr><td>Name</td><td>Type</td><td>Read Only</td><td>Description</td></tr><tr><td>Address</td><td>String</td><td>-</td><td>IPv6 address.</td></tr><tr><td>AddressOrigin</td><td>String</td><td>-</td><td>IPv6 address source.</td></tr><tr><td>PrefixLength</td><td>String</td><td>-</td><td>IPv6 network prefix length in bits. Max is 128.</td></tr></table>

# Example:

GET

![The image displays a highly pixelated and blurry vertical section of a graphic, likely a user interface icon. Against a white background, there are dark gray shapes. The most prominent feature is a downward-pointing chevron or arrow at the bottom. A second, indistinct dark shape is visible directly above it. There is no text visible in the image.](.axe-7420gwa-50m-22811-1000-02/2ba31656cd3385a4bd086c7abfe0acdbc51fa3a8ac406681481c528d84a23d28.jpg)

https://172.20.2.12/redfish/v1/Managers/Self/Ethernetlnterfaces/eth1

```jsonl
{
    "@odata.context": "/redfish/v1/$metadata#EthernetInterface.EthernetInterface",
    "@odata.etag": "\"1705564980\",
    "@odata.id": "/redfish/v1/Managers/Self/EthernetInterfaces/eth1",
    "@odata.type": "#EthernetInterface.v1_6_2.EthernetInterface",
    "AutoNeg": true,
    "DHCPv4": {
    "DHCPEnabled": true
    },
    "DHCPv6": {
    "OperatingMode": "Stateless"
    },
    "Description": "Ethernet Interface eth1",
    "FullDuplex": true,
    "HostName": "AMI003064667788",
    "IPv4Addresses": [
    {
    "Address": "172.20.2.12",
    "AddressOrigin": "DHCP",
    "Gateway": "172.20.2.1",
    "SubnetMask": "255.255.255.0"
    }
    ],
    "IPv6Addresses": [
    {
    "Address": "fe80::230:64ff:fea1:b104",
    "AddressOrigin": "LinkLocal",
    "PrefixLength": 64
    }
    ],
    "IPv6DefaultGateway": null,
    "Id": "eth1",
    "InterfaceEnabled": true,
```

```txt
"LinkStatus": "LinkUp",
"MACAddress": "00:30:64:A1:B1:04",
"MTUSize": 1500,
"MaxIPv6StaticAddresses": 16,
"Name": "eth1",
"NameServers": [
    "192.168.1.213",
    "192.168.1.214"
],
"Oem": {
    "Ami": {
    "@odata.type": "#AMIDNSConfiguration.v1_0_0.AMIDNSConfiguration",
    "DNSEnabled": true,
    "HostNameSetting": "Auto"
    }
},
"PermanentMACAddress": "00:30:64:A1:B1:04",
"SpeedMbps": 100,
"StatelessAddressAutoConfig": {
    "IPv4AutoConfigEnabled": false,
    "IPv6AutoConfigEnabled": false
},
"StaticNameServers": [
    null,
    null,
    null
],
"Status": {
    "Health": "OK",
    "State": "Enabled"
},
"VLAN": {
    "VLANEnable": false,
    "VLANId": 0
}
```

# PATCH - Ethernet Interface Instance

# Request:

```txt
PATCH https://{bmc ip}/redfish/v1/Managers/Self/EthernetInterfaces/{instance}
```

Please refer to the Ethernet Interface Properties that are patchable for which Read Only is False that can be sent as Request body in JSON format.

# Response:

The response status is 202 Accepted, with newly created Task details.

Example: Disable IPv4 DHCP and set static IPv4 address.

Add a key "If-Match" in request Headers tab. The value is your ETag value.

![PATCH https://172.20.2.12/redfish/v1/Managers/Self/EthernetInterfaces/eth1\nParams Authorization • Headers (10) Body • Pre-request Script Tests Settings\nHeaders 9 hidden\nKey Value\nIf-Match '1705564980'\nKey Value](.axe-7420gwa-50m-22811-1000-02/b9efbe286799a3eb309e503b47f86d124cf42e7429663529c34606df3ead72d9.jpg)

Add raw body data in request Body tab. The data format is JSON.

```json
{
    "DHCPv4": {
    "DHCPEnabled": false
    },
    "IPv4StaticAddresses": [
    {
    "Address": "172.20.2.234",
    "Gateway": "172.20.2.1",
    "SubnetMask": "255.255.255.0"
    }
    ]
}
```

Response body content.
```json
{
    "@odata.context": "/redfish/v1/$metadata#Task.Task",
    "@odata.id": "/redfish/v1/TaskService/Tasks/1",
    "@odata.type": "#Task.v1_4_2.Task",
    "Description": "Task for EthernetInterface Action",
    "Id": "1",
    "Name": "EthernetInterface Action",
    "TaskMonitor": "/redfish/v1/TaskService/TaskMonitors/1",
    "TaskState": "New"
}
```

# BIOS Configuration

# GET - HostInterface Instance

# Request:

```txt
GET https://{bmc ip}/redfish/v1/Managers/Self/HostInterfaces/Self
```

# Response:

The response status is 200 OK.

# Example:

GET

![The image is a low-resolution, cropped section featuring three vertical black lines. To the right of these lines is a blurry, V-shaped or chevron-like graphic element. The background is white, and there is no legible text visible.](.axe-7420gwa-50m-22811-1000-02/6ec2415707789f356eba605ba00e17eb4013c91eb3acf7afac8caeb976fa0dd6.jpg)

```txt
https://172.20.2.12/redfish/v1/Managers/Self/HostInterfaces/Self
```

```javascript
"@odata.context": "/redfish/v1/$metadata#HostInterface.HostInterface",
"@odata.etag": "\"1705997262\
",
"@odata.id": "/redfish/v1/Managers/Self/HostInterfaces/Self",
"@odata.type": "#HostInterface.v1_3_0.HostInterface",
"AuthenticationModes": [
    "BasicAuth",
    "RedfishSessionAuth"
],
"CredentialBootstrapping": {
    "EnableAfterReset": false,
    "Enabled": true,
    "RoleId": "HostInterfaceAdministrator"
},
"Description": "Host Interface",
```

```txt
"ExternallyAccessible": false,
"HostEthernetInterfaces": {
    "@odata.id": "/redfish/v1/Managers/Self/HostInterfaces/Self/HostEthernetInterfaces"
},
"HostInterfaceType": "NetworkHostInterface",
"Id": "Self",
"InterfaceEnabled": true,
"Links": {
    "ComputerSystems": [
    {
    "@odata.id": "/redfish/v1/Systems/Self"
    }
    ],
    "ComputerSystems@odata.count": 1,
    "CredentialBootstrappingRole": {
    "@odata.id": "/redfish/v1/AccountService/Roles/HostInterfaceAdministrator"
    }
},
"ManagerEthernetInterface": {
    "@odata.id": "/redfish/v1/Managers/Self/EthernetInterfaces/usb0"
},
"Name": "Host Interface",
"NetworkProtocol": {
    "@odata.id": "/redfish/v1/Managers/Self/NetworkProtocol"
},
"Status": {
    "Health": "OK",
    "State": "Enabled"
}
}
```

# GET – BIOS and BIOS/SD

# Request:

Get current BIOS Settings:

```txt
GET https://{bmc ip}/redfish/v1/Systems/Self/Bios
```

Get future BIOS Settings:

```txt
GET https://{bmc ip}/redfish/v1/Systems/Self/Bios/SD
```

# Response:

The response status is 200 OK.

# Example:

GET

![The image displays three identical grey, downward-pointing chevron icons arranged in a vertical column against a white background.](.axe-7420gwa-50m-22811-1000-02/b06e4b7960b93d3e0870053c2612c0b15a1161b101282afda1f3d29696f2e75d.jpg)

https://172.20.2.12/redfish/v1/Systems/Self/Bios

{

```javascript
"@Redfish.Settings": {
    "@odata.type": "#Settings.v1_2_2.Settings",
    "SettingsObject": {
    "@odata.id": "/redfish/v1/Systems/Self/Bios/SD"
    }
},
"@odata.context": "/redfish/v1/$metadata#Bios.Bios",
"@odata.etag": "\"1705640880\",
"@odata.id": "/redfish/v1/Systems/Self/Bios",
"@odata.type": "#Bios.v1_2_0.Bios",
"Actions": {
    "#Bios.ChangePassword": {
    "@Redfish.ActionInfo": "/redfish/v1/Systems/Self/Bios/ChangePasswordActionInfo",
    "target": "/redfish/v1/Systems/Self/Bios/Actions/Bios.ChangePassword"
    },
    "#Bios.ResetBios": {
    "target": "/redfish/v1/Systems/Self/Bios/Actions/Bios.ResetBios"
    }
},
"AttributeRegistry": "BiosAttributeRegistry22808.1.1.0",
"Attributes": {
    "ACPI004": false,
    "CRCS005": "CRCS005Enable",
    "FBO001": "FBO001UEFI",
```

```json
"FBO101": "FBO101HardDisk",
"FBO102": "FBO102NVME",
...
},
"Description": "Current BIOS Settings",
"Id": "Bios",
"Name": "Current BIOS Settings",
"ResetBiosToDefaultsPending": false
}
```

# POST – Reset BIOS Settings

# Request:

POST https://{{bmc ip}}/redfish/v1/Systems/Self/Bios/Actions/Bios.ResetBios

# Response:

The response status is 204 No Content.

# Example:

Add raw body data in request Body tab. The data format is JSON.

![POST\nhttps://172.20.2.137/redfish/v1/Systems/Self/Bios/Actions/Bios.ResetBios\nParams Authorization Headers (9) Body Pre-request Script Tests Settings\nnone form-data x-www-form-urlencoded raw binary JSON\n1\n2](.axe-7420gwa-50m-22811-1000-02/e232fbf3d725c86de1616cd09373ec05c121bb8217bc38bbec5419d32d4de6f0.jpg)

# POST – Change BIOS Password

# Request:

POST https://{{bmc ip}}/redfish/v1/Systems/Self/Bios/Actions/Bios.ChangePassword

# Response:

The response status is 204 No Content.

# Example:

Add raw body data in request Body tab. The data format is JSON.

![POST\nhttps://172.20.2.137/redfish/v1/Systems/Self/Bios/Actions/Bios.ChangePassword\nParams Authorization \nHeaders (9) Body \nPre-request Script Tests Settings\nnone form-data x-www-form-urlencoded raw binary JSON](.axe-7420gwa-50m-22811-1000-02/70f0a2bf0d85ca549aea78780bb0d8c26a8d50f28ccb36731bcf22f94d9e1a00.jpg)

```json
{
    "PasswordName": "SETUP001",
    "OldPassword": "old",
    "NewPassword": "new"
}
```

# PATCH – BIOS SD

Change the values of the attributes.

# Request:

```txt
PATCH https://{bmc ip}/redfish/v1/Systems/Self/Bios/SD
```

# Response:

The response status is 204 No Content.

Refer to PATCH - BIOS Watchdog Configuration.

# Sensor Information

This section is dedicated to explaining how to obtain sensor information through Redfish. Users can obtain the specific data of the required sensor through the following command.

# Request:

```txt
GET https://{bmc ip}/redfish/v1/Chassis/Self/Sensors/{Sensor ID}
```

# Response:

The response status is 200 OK.

# Example:

GET

![The image displays two identical grey downward-pointing chevrons arranged horizontally on a white background.](.axe-7420gwa-50m-22811-1000-02/ff52048070acf862734399cc5e9beb58b0be88a5e40c350753082734d2bcbadd.jpg)

```txt
https://172.20.2.36/redfish/v1/Chassis/Self/Sensors/1
```

```javascript
"@odata.context": "/redfish/v1/$metadata#Sensor.Sensor",
"@odata.etag": "\"1708661966\",
"@odata.id": "/redfish/v1/Chassis/Self/Sensors/1",
"@odata.type": "#Sensor.v1_0_2.Sensor",
"Accuracy": null,
"AdjustedMaxAllowableOperatingValue": null,
"AdjustedMinAllowableOperatingValue": null,
"ApparentVA": null,
"Description": null,
"ElectricalContext": null,
"Id": "1",
```

```javascript
"LoadPercent": null,
"Location": {
    "AltitudeMeters": null,
    "Contacts": [
    null
    ],
    "Latitude": null,
    "Longitude": null,
    "PartLocation": {
    "LocationOrdinalValue": null,
    "LocationType": null,
    "Orientation": null,
    "Reference": null,
    "ServiceLabel": null
    },
    "Placement": {
    "AdditionalInfo": null,
    "Rack": null,
    "RackOffset": null,
    "RackOffsetUnits": null,
    "Row": null
    },
    "PostalAddress": {
    "AdditionalCode": null,
    "AdditionalInfo": null,
    "Building": null,
    "City": null,
    "Community": null,
    "Country": null,
    "District": null,
    "Division": null,
    "Floor": null,
    "HouseNumber": null,
    "HouseNumberSuffix": null,
    "Landmark": null,
    "LeadingStreetDirection": null,
```

```javascript
"Name": null,
"Neighborhood": null,
"POBox": null,
"PlaceType": null,
"PostalCode": null,
"Road": null,
"RoadBranch": null,
"RoadPostModifier": null,
"RoadPreModifier": null,
"RoadSection": null,
"RoadSubBranch": null,
"Room": null,
"Seat": null,
"Street": null,
"StreetSuffix": null,
"Territory": null,
"TrailingStreetSuffix": null,
"Unit": null
}
},
"MaxAllowableOperatingValue": null,
"MinAllowableOperatingValue": null,
"Name": "P12V_PSU",
"PeakReading": null,
"PeakReadingTime": null,
"PhysicalContext": "VoltageRegulator",
"PhysicalSubContext": null,
"PowerFactor": null,
"Precision": null,
"ReactiveVAR": null,
"Reading": 12.22,
"ReadingRangeMax": 13.25,
"ReadingRangeMin": 10.7,
"ReadingType": "Voltage",
"ReadingUnits": null,
"SensingFrequency": null,
```

```txt
"SensorResetTime": null,
"Status": {
    "Health": "OK",
    "HealthRollup": null,
    "State": "Enabled"
},
"Thresholds": {
    "LowerCaution": {
    "Activation": null,
    "DwellTime": null,
    "Reading": 11.4
    },
    "LowerCritical": {
    "Activation": null,
    "DwellTime": null,
    "Reading": 11.16
    },
    "LowerFatal": {
    "Activation": null,
    "DwellTime": null,
    "Reading": 10.8
    },
    "UpperCaution": {
    "Activation": null,
    "DwellTime": null,
    "Reading": 12.6
    },
    "UpperCritical": {
    "Activation": null,
    "DwellTime": null,
    "Reading": 12.84
    },
    "UpperFatal": {
    "Activation": null,
    "DwellTime": null,
    "Reading": 13.2
```

```txt
}
},
"VoltageType": null
}
```

Other commands to access sensor information using Redfish:

# General Thermal Sensors Information

GET https://{{bmc ip}}/redfish/v1/Chassis/Self/Thermal

Retrieves detailed information about the server's thermal sensors, including current temperature readings.

# Temperature Sensor IDs

GET https://{{bmc ip}}/redfish/v1/Chassis/Self/ThermalSubsystem/ThermalMetrics

Retrieves IDs and specific metrics of temperature-related sensors.

# General Power Sensors Information

GET https://{{bmc ip}}/redfish/v1/Chassis/Self/Power

Retrieves comprehensive data about power-related sensors, including power supply status and output power.

# Power Sensor IDs

GET https://{{bmc ip}}/redfish/v1/Chassis/Self/PowerSubsystem

Retrieves IDs and detailed metrics related to power sensors.

# BMC Update

This section specifically explains how to obtain and upgrade BMC through Redfish.

Users can upgrade BMC and set Preserve Configuration through the following commands.

# GET - Preserve Configuration

This section describes how to use redfish to Get Preserve Configuration before upgrading BMC.

# Request:

GET https://{{bmc ip}}/redfish/v1/UpdateService

# Response:

The response status is 200 OK.

# Example:

```batch
GET https://172.20.2.36/redfish/v1/UpdateService
```

```jsonl
{
    "@odata.context": "/redfish/v1/$metadata#UpdateService.UpdateService",
    "@odata.etag": "\"1708925760\
    "@odata.id": "/redfish/v1/UpdateService",
```

```javascript
"@odata.type": "#UpdateService.v1_6_0.UpdateService",
"Actions": {
    "#UpdateService.SimpleUpdate": {
    "@Redfish.ActionInfo": "/redfish/v1/UpdateService/SimpleUpdateActionInfo",
    "target": "/redfish/v1/UpdateService/Actions/SimpleUpdate"
},
"Oem": {
    "#UpdateService.UploadCABundle": {
    "@Redfish.ActionInfo": "/redfish/v1/UpdateService/UploadCABundleActionInfo",
    "target": "/redfish/v1/UpdateService/Actions/Oem/UpdateService.UploadCABundle"
    }
},
"description": "Redfish Update Service",
"FirmwareInventory": {
    "@odata.id": "/redfish/v1/UpdateService/FirmwareInventory"
},
"Id": "UpdateService",
"MaxImageSizeBytes": 496611328,
"MultipartHttpPushUri": "/redfish/v1/UpdateService/upload",
"Name": "Update Service",
"Oem": {
    "AMIUpdateService": {
    "@odata.type": "#AMIUpdateService.v1_0_0.AMIUpdateService",
    "FlashPercentage": null,
    "PreserveConfiguration": {
    "Authentication": false,
    "EXTLOG": false,
    "FRU": false,
    "IPMI": false,
    "KVM": false,
    "NTP": false,
    "Network": false,
    "REDFISH": false,
    "SDR": false,
    "SEL": false,
```

```javascript
"SNMP": false,
"SSH": false,
"Syslog": false,
"WEB": false
},
"UpdateStatus": null,
"UpdateTarget": null
},
"BMC": {
"@odata.type": "#AMIUpdateService.v1_0_0.BMC",
"DualImageConfigurations": {
"ActiveImage": "2",
"BootImage": "2",
"FirmwareImage1Name": "Image1",
"FirmwareImage1Version": "13.05.010004",
"FirmwareImage2Name": "Image2",
"FirmwareImage2Version": "13.05.010003"
}
},
"ServiceEnabled": true,
"Status": {
"Health": "OK",
"State": "Enabled"
}
```

# PATCH - Preserve Configuration

This section describes how to use redfish to Set Preserve Configuration before upgrading BMC.

# Request:

PATCH https://{{bmc ip}}/redfish/v1/UpdateService

Please refer to the GET - Preserve Configuration.

# Response:

The response status is 204 No Content.

Example: Enable saving IPMI and SEL when upgrading BMC.

Add a key "If-Match" in request Headers tab. The value is your ETag value. This value can be obtained from GET - Preserve Configuration.

<table><tr><td colspan="7">PATCH https://172.20.2.36/redfish/v1/UpdateService</td></tr><tr><td>Params</td><td>Authorization</td><td>Headers (8)</td><td>Body</td><td>Pre-request Script</td><td>Tests</td><td>Settings</td></tr><tr><td>Headers</td><td>7 hidden</td><td></td><td></td><td></td><td></td><td></td></tr><tr><td></td><td>Key</td><td></td><td></td><td></td><td></td><td>Value</td></tr><tr><td></td><td>If-Match</td><td></td><td></td><td></td><td></td><td>&quot;1706750916&quot;</td></tr><tr><td></td><td>Key</td><td></td><td></td><td></td><td></td><td>Value</td></tr></table>

Add raw body data in request Body tab. The data format is JSON.

```json
Params Authorization Headers (10) Body Pre-request Script Tests Settings
none form-data x-www-form-urlencoded raw binary JSON
{
    "Oem": {
    "AMIUpdateService": {
    "PreserveConfiguration": {
    "IPMI": true,
    "SEL": true
    }
    }
    }
}
```

# POST – Firmware Update

This section describes how to use redfish to Update BMC firmware.

# Request:

POST https://{{bmc ip}}/redfish/v1/UpdateService/upload

# Response:

The response status is 202 Accepted.

# Example:

Using POSTMAN, please follow the steps as given below.

1. Ensure that all necessary files mentioned in the subsequent steps are placed in your working directory. Go to the top right corner of POSTMAN and click on the settings button. In the general settings, make the necessary adjustments.

# Working directory

![The image displays a horizontal toggle switch in the 'off' position. It features a white circular knob situated on the left side of a grey, pill-shaped track. There is no text.](.axe-7420gwa-50m-22811-1000-02/2b4cb18fc32564044cb63ee0dd6428dc8ec9381f4a2eec3c8d879a9c561452ea.jpg)

2. Create a JSON file parameters.json with content like below.

```json
{
    "Targets" : [
    "/redfish/v1/UpdateService/FirmwareInventory/BMCImage1"
    ]
}
```

3. Create a JSON file oem\_parameters.json with content like below.

```json
{
    "ImageType" : "BMC"
}
```

4. Open POSTMAN and enter the URI to POST the request.
5. Select POST method.
6. In the Authorization tab, select Basic Auth and update request.
7. In the Body tab, select form-data and provide the key name as UpdateFile in the KEY section and change its type from Text to File.
8. Click on Select File in the VALUE section to select the signed image which is available in your local machine to update.
9. Like step 7 and 8, provide key name UpdateParameters and select parameters.json created in step 2.
10. Like step 7 and 8, provide key name OemParameters and select oem\_parameters.json created in step 3.
11. Click Send.

![POST\nhttps://172.20.2.36/redfish/v1/UpdateService/upload\nSend\nParams Authorization Headers (9) Body Pre-request Script Tests Settings\nnone form-data x-www-form-urlencoded raw binary GraphQL\nKey Value Description --- Bulk Edit\nUpdateParameters File parameters.json\nOemParameters File oem_parameters.json\nUpdateFile File rom.ima\nKey Text Value Description](.axe-7420gwa-50m-22811-1000-02/86065f7534ea77920661130c43cf52a9fa714f5d1c3648fa3650e671dabf82a4.jpg)

# Response:

<table><tr><td colspan="5">Body Cookies Headers (14) Test Results Status: 202 Accepted</td></tr><tr><td>Pretty</td><td>Raw</td><td>Preview</td><td>Visualize</td><td>JSON</td></tr><tr><td>1</td><td></td><td></td><td></td><td></td></tr><tr><td>2</td><td rowspan="2" colspan="4">&quot;@odata.type&quot;: &quot;#UpdateService.v1_6_0.UpdateService&quot;, &quot;Messages&quot;: [</td></tr><tr><td>3</td></tr><tr><td>4</td><td colspan="4">#</td></tr><tr><td>5</td><td rowspan="6" colspan="4">&quot;@odata.type&quot;: &quot;#Message.v1_0_8.Message&quot;, &quot;Message&quot;: &quot;A new task /redfish/v1/TaskService/Tasks/4 was created.&quot;, &quot;MessageArgs&quot;: [ &quot;/redfish/v1/TaskService/Tasks/4&quot; ], &quot;MessageId&quot;: &quot;Task.1.0.New&quot;, &quot;Resolution&quot;: &quot;None&quot;, &quot;Severity&quot;: &quot;OK&quot; } ,</td></tr><tr><td>9</td></tr><tr><td>10</td></tr><tr><td>11</td></tr><tr><td>12</td></tr><tr><td>13</td></tr><tr><td>14</td><td colspan="4">#</td></tr><tr><td>15</td><td rowspan="4" colspan="4">&quot;@odata.type&quot;: &quot;#Message.v1_0_8.Message&quot;, &quot;Message&quot;: &quot;The action UpdateService.MultipartPush was submitted to do firmware update.&quot;, &quot;MessageArgs&quot;: [ &quot;UpdateService.MultipartPush&quot;</td></tr><tr><td>16</td></tr><tr><td>17</td></tr><tr><td>18</td></tr></table>

# Note:

The details of UpdateParameters are given in the table below.

<table><tr><td>Allowed value</td><td>Description</td></tr><tr><td>redfish/v1/UpdateService/FirmwareInventory/BMC</td><td>When the system does not support Dual Flash</td></tr><tr><td>redfish/v1/UpdateService/FirmwareInventory/BMCImage1</td><td>For systems with Dual Flash support, to upgrade Image 1</td></tr><tr><td>redfish/v1/UpdateService/FirmwareInventory/BMCImage2</td><td>For systems with Dual Flash support, to upgrade Image 2</td></tr></table>

# BIOS Update

This section specifically explains how to obtain and upgrade BIOS through Redfish.

Users can upgrade BIOS through the following commands.

# GET - BIOS Update Status

# Request:

$\mathsf { G E T h t t p s } . / / \qquad | \mathsf { r e d f i s h } / \mathsf { v } 1 / \mathsf { U p d a t e S e r v i c e }$

# Response:

The response status is 200 OK.

<table><tr><td>Name</td><td>Type</td><td>Read Only</td><td>Description</td></tr><tr><td>BIOSFlashEffectStatus</td><td>String</td><td>√</td><td>Indicates the BIOS update effect status:Waiting: there is a BIOS update task waiting to take effect.Updating: someone is updating BIOS.null: no BIOS update task.</td></tr></table>

# Example:

# GET

![The image displays a row of four identical, dark gray, downward-pointing chevron symbols arranged horizontally against a white background.](.axe-7420gwa-50m-22811-1000-02/c2b41b5dd538f65d1227493f066a2c4bf8a9781d601c4bfbdf5aa138816bdd57.jpg)

https://172.20.2.18/redfish/v1/UpdateService

```javascript
"@odata.context": "/redfish/v1/$metadata#UpdateService.UpdateService",
"@odata.etag": "\"1708587273 Main
"@odata.id": "/redfish/v1/UpdateService",
"@odata.type": "#UpdateService.v1_6_0.UpdateService",
"Actions": {
    "#UpdateService.SimpleUpdate": {
    "@Redfish.ActionInfo": "/redfish/v1/UpdateService/SimpleUpdateActionInfo",
    "target": "/redfish/v1/UpdateService/Actions/SimpleUpdate"
},
    "Oem": {
    "#UpdateService.UploadCABundle": {
    "@Redfish.ActionInfo": "/redfish/v1/UpdateService/UploadCABundleActionInfo",
    "target": "/redfish/v1/UpdateService/Actions/Oem/UpdateService.UploadCABundle"
    }
    }
},
"Description": "Redfish Update Service",
"FirmwareInventory": {
    "@odata.id": "/redfish/v1/UpdateService/FirmwareInventory"
},
"Id": "UpdateService",
"MaxImageSizeBytes": 496717824,
"MultipartHttpPushUri": "/redfish/v1/UpdateService/upload",
"Name": "Update Service",
"Oem": {
    "AMIUpdateService": {
    "@odata.type": "#AMIUpdateService.v1_0_0.AMIUpdateService",
    "BIOSFlashEffectStatus": null,
    "FlashPercentage": null,
    "PreserveConfiguration": {
    "Authentication": false,
    "EXTLOG": false,
```

```json
"FRU": false,
"IPMI": false,
"KVM": false,
"NTP": false,
"Network": false,
"REDFISH": false,
"SDR": false,
"SEL": false,
"SNMP": false,
"SSH": false,
"Syslog": false,
"WEB": false
},
"UpdateStatus": null,
"UpdateTarget": null
},
"BMC": {
"@odata.type": "#AMIUpdateService.v1_0_0.BMC",
"DualImageConfigurations": {
"ActiveImage": "1",
"BootImage": "1",
"FirmwareImage1Name": "Image1",
"FirmwareImage1Version": "13.05.010004",
"FirmwareImage2Name": "Image2",
"FirmwareImage2Version": "13.05.010003"
}
},
"ServiceEnabled": true,
"Status": {
"Health": "OK",
"State": "Enabled"
}
```

# POST – Firmware Update

This section describes how to use redfish to Update BIOS firmware.

# Request:

POST https://{{bmc ip}}/redfish/v1/UpdateService/upload

# Response:

The response status is 202 Accepted.

# Example:

Using POSTMAN, please follow the steps as given below.

1. Ensure that all necessary files mentioned in the subsequent steps are placed in your working directory. Go to the top right corner of POSTMAN and click on the settings button. In the general settings, make the necessary adjustments.

# Working directory

![A grey, pill-shaped toggle switch with a white circular knob positioned on the left side, indicating an 'off' state.](.axe-7420gwa-50m-22811-1000-02/a60366890fd2858dd2495b82bd78d7b8b94c35509d29f2d22770c60af24d29c3.jpg)

2. Create a JSON file parameters.json with content like below.

```json
{
    "Targets" : [
    "/redfish/v1/UpdateService/FirmwareInventory/BIOS"
    ]
}
```

3. Create a JSON file oem\_parameters.json with content like below.

```json
{
    "ImageType" : "BIOS",
    "update_me" : false,
    "update_nvram" : false,
    "effect_poweroff" : false,
    "force_update" : false
}
```

<table><tr><td>Name</td><td>Type</td><td>Description</td></tr><tr><td>update_me</td><td>Boolean</td><td>Optional. Default value is false. true: update ME. false: skip ME.</td></tr><tr><td>update_nvram</td><td>Boolean</td><td>Optional. Default value is false. true: update NVRAM. false: skip NVRAM.</td></tr><tr><td>effect_poweroff</td><td>Boolean</td><td>Optional. Default value is false. true: take effect when powered off. false: take effect immediately.</td></tr><tr><td>force_update</td><td>Boolean</td><td>Optional. Default value is false. true: force to update. false: do not update when other user is in in update mode or a BIOS firmware has been uploaded.</td></tr></table>

4. Open POSTMAN and enter the URI to POST the request.
5. Select POST method.
6. In the Authorization tab, select Basic Auth and update request.
7. In the Body tab, select form-data and provide the key name as UpdateFile in the KEY section and change its type from Text to File.
8. Click on Select File in the VALUE section to select the signed image which is available in your local machine to update.
9. Like step 7 and 8, provide key name UpdateParameters and select parameters.json created in step 2.
10. Like step 7 and 8, provide key name OemParameters and select oem\_parameters.json created in step 3.
11. Click Send.

<table><tr><td>POST</td><td colspan="4">https://172.20.2.18/redfish/v1/UpdateService/upload</td></tr><tr><td colspan="5">Params Authorization Headers (10) Body Pre-request Script Tests Settings Cookies none form-data x-www-form-urlencoded raw binary</td></tr><tr><td></td><td>Key</td><td>Value</td><td>∞∞</td><td>Bulk Edit</td></tr><tr><td>✓</td><td>UpdateFile</td><td>MECS-7120_1210.BIN ×</td><td colspan="2">A</td></tr><tr><td>✓</td><td>UpdateParameters</td><td>parameters.json ×</td><td colspan="2">A</td></tr><tr><td>✓</td><td>OemParameters</td><td>oem_parameters.json ×</td><td colspan="2">A</td></tr><tr><td></td><td>Key</td><td colspan="3">Value</td></tr></table>

Response:
```jsonl
{
    "@odata.type": "#UpdateService.v1_6_0.UpdateService",
    "Messages": [
    {
    "@odata.type": "#Message.v1_0_8.Message",
    "Message": "A new task /redfish/v1/TaskService/Tasks/1 was created.",
    "MessageArgs": [
    "/redfish/v1/TaskService/Tasks/1"
    ],
    "MessageId": "Task.1.0.New",
    "Resolution": "None",
    "Severity": "OK"
    },
    {
    "@odata.type": "#Message.v1_0_8.Message",
    "Message": "The action UpdateService.MultipartPush was submitted to do firmware update.",
    "MessageArgs": [
    "UpdateService.MultipartPush"
    ],
    "MessageId": "UpdateService.1.0.StartFirmwareUpdate",
    "Resolution": "None",
    "Severity": "OK"
    }
    ]
}
```

# CPLD Update

This section specifically explains how to obtain and upgrade BIOS through Redfish.

Users can upgrade BIOS through the following commands.

# GET - CPLD Update Status

Request:
```txt
GET https://{bmc ip}/redfish/v1/UpdateService
```

# Response:

The response status is 200 OK.

<table><tr><td>Name</td><td>Type</td><td>Read Only</td><td>Description</td></tr><tr><td>CPLDFlashEffectStatus</td><td>String</td><td>√</td><td>Indicates the CPLD update effect status:Waiting: there is a CPLD update waiting to take effect.Updating: someone is updating Firmware.null: no CPLD update.</td></tr></table>

# Example:

GET

![The image displays a vertical white strip containing two identical grey chevrons pointing downwards, stacked one above the other. A thin, dark vertical line runs along the right edge of the strip.](.axe-7420gwa-50m-22811-1000-02/2eb12c4784a906533b92dc7841e1c9bcad67a54e7bb110673822b82b24efe25b.jpg)

https://172.20.2.18/redfish/v1/UpdateService

```txt
{
...
"Oem": {
    "AMIUpdateService": {
    "@odata.type": "#AMIUpdateService.v1_0_0.AMIUpdateService",
    "BIOSFlashEffectStatus": null,
    "CPLDFlashEffectStatus": null,
    "FlashPercentage": null,
}
```

# POST – Firmware Update

This section describes how to use redfish to Update CPLD firmware.

# Request:

POST https://{{bmc ip}}/redfish/v1/UpdateService/upload

# Response:

The response status is 202 Accepted.

# Example:

Using POSTMAN, please follow the steps as given below.

1. Ensure that all necessary files mentioned in the subsequent steps are placed in your working directory. Go to the top right corner of POSTMAN and click on the settings button. In the general settings, make the necessary adjustments.

# Working directory

![The image displays a simple toggle switch icon against a white background. It features a gray, horizontal, rounded rectangular track containing a white circular knob positioned on the left side, indicating an 'off' state.](.axe-7420gwa-50m-22811-1000-02/eee69dfa795b961e3a1d633f0dfebd366d8cc44b45192d048b14b6677da13099.jpg)

2. Create a JSON file parameters.json with content like below.

```json
{
    "Targets" : [
    "/redfish/v1/UpdateService/FirmwareInventory/CPLD"
    ]
}
```

3. Create a JSON file oem\_parameters.json with content like below.

```json
{
    "ImageType" : "HPM",
    "force_update" : false
}
```

<table><tr><td>Name</td><td>Type</td><td>Description</td></tr><tr><td>force_update</td><td>Boolean</td><td>Optional. Default value is false.true: force to update.false: do not update when other user is in in update mode or a CPLD firmware has been uploaded.</td></tr></table>

4. Open POSTMAN and enter the URI to POST the request.
5. Select POST method.
6. In the Authorization tab, select Basic Auth and update request.
7. In the Body tab, select form-data and provide the key name as UpdateFile in the KEY section and change its type from Text to File.
8. Click on Select File in the VALUE section to select the signed image which is available in your local machine to update.
9. Like step 7 and 8, provide key name UpdateParameters and select parameters.json created in step 2.
10. Like step 7 and 8, provide key name OemParameters and select oem\_parameters.json created in step 3.
11. Click Send.

![POST\nhttps://172.20.2.18/redfish/v1/UpdateService/upload\nSend\nParams Authorization \nHeaders (10) Body \nPre-request Script Tests Settings\nnone \nform-data \nx-www-form-urlencoded \nraw \nbinary\nCookies\nKey\nValue\nooo\nBulk Edit\nUpdateFile\noutputjbc_02b4.hpm ×\nUpdateParameters\nparameters.json ×\nOemParameters\noem_parameters.json ×\nKey\nValue](.axe-7420gwa-50m-22811-1000-02/b809217b96a7309d62800487221c3f43c0fe3fc4084560f18331929308caf8d6.jpg)

# Response:

```jsonl
{
    "@odata.type": "#UpdateService.v1_6_0.UpdateService",
    "Messages": [
    {
    "@odata.type": "#Message.v1_0_8.Message",
    "Message": "A new task /redfish/v1/TaskService/Tasks/1 was created.",
    "MessageArgs": [
    "/redfish/v1/TaskService/Tasks/1"
    ],
    "MessageId": "Task.1.0.New",
    "Resolution": "None",
    "Severity": "OK"
    },
    {
    "@odata.type": "#Message.v1_0_8.Message",
    "Message": "The action UpdateService.MultipartPush was submitted to do firmware update.",
    "MessageArgs": [
    "UpdateService.MultipartPush"
    ],
    "MessageId": "UpdateService.1.0.StartFirmwareUpdate",
    "Resolution": "None",
    "Severity": "OK"
    }
    ]
}
```

# Power Control

This section is dedicated to explaining how to control power through Redfish.

# Request:

```txt
POST https://{bmc ip}/redfish/v1/Chassis/Self/Actions/Chassis.Reset
```

# Response:

The response status is 202 Accepted.

# Example:

![POST\nhttps://172.20.2.16/redfish/v1/Chassis/Self/Actions/Chassis.Reset\nParams Authorization Headers (10) Body Pre-request Script Tests Settings\nnone form-data x-www-form-urlencoded raw binary JSON\n{\n'ResetType': 'ForceRestart'\n}](.axe-7420gwa-50m-22811-1000-02/029cf445a0511f385212a740ff997e45d4d1458dd7c8a2861a78ab7c4abc7c28.jpg)

Note: The ResetType can be one of the following values: "On", "ForceOff", "GracefulShutdown", "ForceRestart", "PowerCycle".

# Response:

```json
{
    "@odata.context": "/redfish/v1/$metadata#Task.Task",
    "@odata.id": "/redfish/v1/TaskService/Tasks/1",
    "@odata.type": "#Task.v1_4_2.Task",
    "Description": "Task for Chassis Reset",
    "Id": "1",
    "Name": "Chassis Reset",
    "TaskMonitor": "/redfish/v1/TaskService/TaskMonitors/1",
    "TaskState": "New"
}
```

# BMC Firmware Version

To get BMC version, use "Managers" class.

# Request:

```txt
POST https://{bmc ip}/redfish/v1/Managers/Self
```

# Response:

The response status is 200 OK.

# Example:

![GET\nhttps://192.168.1.1/redfish/v1/Managers/Self\n≡ Docs Params Authorization • Headers (8) Body Scripts Settings\nnone ○ form-data ○ x-www-form-urlencoded ○ raw ○ binary ○ GraphQL](.axe-7420gwa-50m-22811-1000-02/094bffda7f660e3eb29360168278de4cbd802cb8acbcccf0f4a47a18263ecf89.jpg)

![Body Cookies Headers (24) Test Results | 200 OK · 198 ms · 4.34 KB · e.g. Sa\n{ } JSON ▷ Preview Visualize ▼\n62 'FirmwareVersion': '1.02.100',](.axe-7420gwa-50m-22811-1000-02/c8189ab091d83c1cabdd4a754e1e9501e9fb9b68e590babcc851ea8f9de21623.jpg)

Member "FirmwareVersion" consists of:

BMC version - 1.02.100

# BIOS Version

To get BIOS version, use "Systems" class.

# Request:

```txt
POST https://{bmc ip}/redfish/v1/Systems/Self
```

# Response:

The response status is 202 OK.

# Example:

![GET\nhttps://172.20.2.18/redfish/v1/Systems/Self\nParams Authorization Headers (9) Body Pre-request Script\nBody Cookies Headers (31) Test Results\nPretty Raw Preview Visualize JSON\n32 },\n33 'BiosVersion': '1.2.10',\n34 'Boot': {\n35 'RootNext': null.](.axe-7420gwa-50m-22811-1000-02/db5f079a5ba1362ffebe4b192f4818cbb74a87ceb0a9998e7cbfc0e466c2588b.jpg)

Member "BiosVersion" has the value.

"1.2.10" - Leading version.Major version.Minor version

Please note that minor version of BIOS is always represented in hexadecimal number.

# Safety Instructions

For user safety, please read and follow all instructions, WARNINGS, CAUTIONS, and NOTES marked in this manual and on the associated equipment before handling/operating the equipment.

1. Read these safety instructions carefully.

2. Keep this user’s manual for future reference.

3. Read the specifications section of this manual for detailed information on the operating environment of this equipment.

4. The equipment can be operated at an ambient temperature of 55°C.

5. When installing/mounting or uninstalling/removing equipment; or when removal of the chassis lid required for user servicing (Section 3.1-3.5):

Turn off power and unplug any power cords/cables, and
Reinstall the chassis lid before restoring power.

![The image displays a standard safety symbol consisting of a red equilateral triangle with a white exclamation point in the center. Below the triangle, the text 'WARNING:' is written in black, uppercase letters against a white background.](.axe-7420gwa-50m-22811-1000-02/e9b4837cbb4b113b14f93247cfc108e8070537097713bfe4b1e80a24dadba8ce.jpg)

Hazardous moving parts. Keep body parts out of the motion path.

![The image displays a black and white line drawing. It features a large, upward-pointing equilateral triangle outlined in black. Centered inside the triangle is a symbol resembling a fan or propeller, consisting of a central dot with four curved, petal-like blades radiating outward.](.axe-7420gwa-50m-22811-1000-02/7895c81c376edc2ccc24b50109ae4fbbc462d55d9a8a34be657bbf51bc581222.jpg)

6. To avoid electrical shock and/or damage to equipment:

Keep equipment away from water or liquid sources;
Keep equipment away from high heat or high humidity;
Keep equipment properly ventilated (do not block or cover ventilation openings);
Make sure to use recommended voltage and power source settings;
• Always install and operate equipment near an easily accessible electrical socket-outlet;
Secure the power cord (do not place any object on/over the power cord);
The power cord must be connected to a socket or outlet with a ground connection.

• Only install/attach and operate equipment on stable surfaces and/or recommended mountings;

• If the equipment will not be used for long periods of time, turn off and unplug the equipment from its power source.

7. Never attempt to fix the equipment. Equipment should only be serviced by qualified personnel.

8. An RTC battery may be provided for uninterrupted, backup or emergency power.

![The image shows a yellow triangular warning sign with a thick black border. Centered inside the triangle is a large black exclamation point. Below the triangle, the text 'CAUTION:' is written in black capital letters.](.axe-7420gwa-50m-22811-1000-02/d80736b4b194eb4aa5b593a12f7f14688b3390e6d22cb021adb07145d89cbaf6.jpg)

Risk of explosion if battery is replaced with one of an incorrect type. Discard used batteries according to the manufacturer's instructions.

9. This equipment is not suitable for use in locations where children are likely to be present.

10. Equipment must be serviced by authorized technicians when:

The power cord or plug is damaged;
Liquid has penetrated the equipment;
It has been exposed to high humidity/moisture;
• It is not functioning or does not function according to the user’s manual;
It has been dropped and/or damaged; and/or,
It has an obvious sign of breakage.

11. Please pay strict attention to all warnings and advisories appearing on the device, to avoid injury or damage.

12. The equipment may have more than one power supply input. To reduce the risk of electrical shock, trained personnel should disconnect all power supply inputs before servicing.

![The image shows a yellow triangular warning sign with a black border. Inside the triangle is a large black exclamation point. Below the triangle, the text reads 'CAUTION:' in black capital letters.](.axe-7420gwa-50m-22811-1000-02/435eb3ff2a750a888facf00bad45ad963b047017af24e81b4d39cba01aaa92c1.jpg)

Shock hazard! Disconnect all power supply inputs before servicing.

![The image features a yellow triangular warning sign with a black border and a black lightning bolt symbol in the center. Below the sign, the text 'Shock hazard!' appears in black font.](.axe-7420gwa-50m-22811-1000-02/b379721cb8758b58b485f9bb3543b8f041f1b3d77a4c9b7421f6fc03a10d4a18.jpg)

![Multiple power sources](.axe-7420gwa-50m-22811-1000-02/782e3cda5537f8482d7bc1c311f6a90ebc0f1dc8c15297675f1ba83baaf3b3a8.jpg)

13. It is recommended that equipment be installed only in a server room or computer room where access is:

Restricted to qualified service personnel or users familiar with restrictions applied to the location, reasons therefor, and any precautions required;
Only afforded by the use of a tool or lock and key, or other means of security, and is controlled by the authority responsible for the location.

14. Suitable for installation in Information Technology Rooms in accordance with Article 645 of the National Electrical Code and NFPA 75.

15. This product is intended to be supplied by a certified DC power source providing reinforced/double insulation from AC mains with an output rating of 36V to 72V DC ,20A min., Tma = 55°C. All power connection wiring must be performed by a qualified electrician in accordance with National Electrical Code, ANSI/NFPA 70 and Canadian Electrical Code, Part I, CSA C22.1. The DC power supply should be well-grounded to ensure safe operation. The protective earthing conductor shall be minimum 14 AWG and having green-and-yellow insulation. The ground wire should be installed first (before "+" and "-") and then removed.

16. When using a Fiber Optic Small-Form Pluggable (SFP) module, ensure it is IEC 60825-1, IEC 60825-2 and IEC 60950-1 or IEC 62368-1 certified and a Class 1 Laser Product.

# Consignes de Sécurité Importantes

Pour assurer la sécurité de l’utilisateur, veuillez lire et suivre toutes les directives, ainsi que les AVERTISSEMENTS, MISES EN GARDE et REMARQUES de ce manuel et indiqués sur l’équipement associé avant de manipuler ou utiliser l’équipement.

1. Veuillez lire attentivement ces instructions de sécurité avec soin.
2. Veuillez conserver ce manuel pour référence future.
3. Veuillez lire la section des spécifications de ce manuel pour avoir des informations détaillées sur l’environnement d’exploitation de cet équipement.
4. L’équipement peut être utilisé à une température ambiante de 55 °C.
5. Lors de l’installation ou du montage et de la désinstallation ou de la dépose de l’équipement; ou lors de la dépose du couvercle du châssis pour procéder à l’entretien par l’utilisateur (Sections 3.1-3.5):

Coupez l’alimentation et débranchez les cordons et les câbles d’alimentation, et
Reposez le couvercle du châssis avant de remettre l’alimentation.

![The image features a red triangle containing a white exclamation point, positioned above the black text 'WARNING:'.](.axe-7420gwa-50m-22811-1000-02/5cf9a6e85ba622f3074bd525470168fa61b03f2a9d3af1ffe98c954a462801c4.jpg)
AVERTISSEMENT

Pièces mobiles dangereuses. Gardez les parties du corps hors de la trajectoire.

![The image displays a black and white graphic featuring a large equilateral triangle with a thick black outline. Inside the triangle is a symbol resembling a four-bladed fan or propeller, with curved blades radiating from a small central white circle. The entire graphic is framed by thick black horizontal bars at the very top and bottom of the image.](.axe-7420gwa-50m-22811-1000-02/dd6a08437ab34ec1248aabbcd111e6b896cc1e98b4e2f3b1904266d654e04591.jpg)

6. Pour éviter un risque d’électrocution et pour éviter d’endommager l’équipement :

Éloignez l’équipement de l’eau et de toute source liquide;
Éloignez l’équipement de toute source de chaleur ou d’humidité élevée;
Gardez l’équipement correctement ventilé (ne pas bloquer ou couvrir les ouvertures de ventilation);
• Veillez à utiliser la tension recommandée et les réglages adéquats pour la source d’alimentation;
Veuillez toujours installer et exploiter l’équipement à proximité d’une prise de courant facilement accessible;
Assurez-vous que le cordon d’alimentation est acheminé de manière sécuritaire (ne déposez aucun objet dessus);
Installez, fixez et utilisez l’équipement sur des surfaces stables ou sur les fixations recommandées uniquement;
Si l’équipement n’est pas utilisé pendant une longue période, éteignez-le et débranchez-le de sa source d’alimentation.
• Le cordon d'alimentation doit être connecté à une prise ou à une prise de courant avec mise à la terre.

7. N’essayez jamais de réparer l’équipement. L’équipement ne doit être réparé que par du personnel qualifié.

8. Une pile au lithium peut être installée pour assurer l’alimentation de secours ou d’urgence en continu.

![The image shows a yellow triangular warning sign with a thick black border. Inside the triangle is a large black exclamation point. Below the triangle, the word 'CAUTION:' appears in black capital letters.](.axe-7420gwa-50m-22811-1000-02/1b5ea27c7883c2fa92e1bcfdd5179cf794049008dea4424b49e3c5724fe4182d.jpg)
mise en garde

Risque d'explosion si la batterie est remplacée par une batterie d'un type incorrect. Jetez les piles usagées conformément aux instructions du fabricant.

9. Cet équipement ne convient pas à une utilisation dans des lieux pouvant accueillir des enfants.

10. L’équipement doit être entretenu par des techniciens agréés lorsque :

• le cordon d’alimentation est endommagé ou lorsque la fiche électrique est endommagée;
du liquide a pénétré à l’intérieur de l’équipement;
l’équipement a été exposé à un taux d’humidité élevé;
• l’équipement ne fonctionne pas ou ne fonctionne pas conformément au manuel de l’utilisateur;
l’équipement est tombé ou lorsqu’il a été endommagé;
l’équipement présente un signe évident de défaillance.

11. Veuillez porter une attention rigoureuse à tous les avertissements et à tous les avis figurant sur l’appareil, pour éviter des blessures ou des dommages.

12. L’équipement peut avoir plus d’une entrée d’alimentation. Pour réduire le risque d’électrocution, le personnel qualifié devrait déconnecter toutes les entrées d’alimentation avant de procéder à l’entretien.

![The image displays a yellow triangular warning sign containing a black exclamation point. Below the symbol, the text reads 'CAUTION:' in black capital letters, followed by 'mise en garde' in black lowercase letters on the line below.](.axe-7420gwa-50m-22811-1000-02/98cde554a6549f39380d867ee25862f81e99d381894b3c54944d1aadd0872f22.jpg)

Risque d'électrocution! Débranchez toutes les entrées d'alimentation avant de procéder à l'entretien.

![The image shows a standard safety warning sign consisting of a yellow equilateral triangle with a thick black border. In the center is a black lightning bolt symbol, indicating a high voltage or electrical hazard.](.axe-7420gwa-50m-22811-1000-02/ae410faa2ca8ea3872520814c462849e117d7f9b8bfeaafafcc5e1876647a51f.jpg)
Shock hazard! Risque d'électrocution!

![The image displays a black-and-white schematic symbol. On the far left, there are two vertical parallel lines. Next to them, two horizontal lines extend to the right and enter the left side of a triangle that points to the right. From the right side of the triangle, three horizontal lines emerge, each terminating in a short vertical bar perpendicular to the line. Above these three lines, a long horizontal arrow points to the right.](.axe-7420gwa-50m-22811-1000-02/18df9d1e660e0a67ab1a017b9921611daf373c04b8e696e83da78f8528fd9eb0.jpg)
Multiple power sources Sources d'alimentation multiples

13. Il est recommandé que l'équipement soit installé que dans une salle de serveur ou de la salle informatique où:

L'accès est limité au personnel de maintenance qualifié ou utilisateurs familiers avec les restrictions appliquées à l'emplacement, motifs, et tout les précautions nécessaires, et;
L'accès est uniquement assurée par l'utilisation d'un outil ou clé, ou d'autres moyens de sécurité, et est contrôlé par l'autorité responsable de l'emplacement.

14. Peut être installé dans des salles de matériel de traitement de l’information conformément à l’article 645 du National Electrical Code et à la NFPA 75.

15. Ce produit est destiné à être alimenté par une source d'alimentation CC certifiée fournissant une isolation renforcée/double du secteur CA avec une puissance de sortie de -48 V à -60 V CC, 12 A min., Tma = 55°C. Tout le câblage de connexion d'alimentation doit être effectué par un électricien qualifié conformément au Code national de l'électricité, ANSI / NFPA 70 et au Code canadien de l'électricité, Partie I, CSA C22.1. L'alimentation CC doit être bien mise à la terre pour garantir un fonctionnement sûr. Le conducteur de mise à la terre de protection doit être au minimum 14 AWG et avoir une isolation verte et jaune. Le fil de terre doit être installé en premier (avant «+» et «-») puis retiré.

# FCC Warning

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

— Reorient or relocate the receiving antenna.
— Increase the separation between the equipment and receiver.
— Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
1 Consult the dealer or an experienced radio/TV technician for assistance.

# Getting Service

Ask an Expert: https://www.adlinktech.com/en/Askanexpert

# ADLINK Technology, Inc.

Address: No. 66, Huaya 1st Road, Guishan District Taoyuan City 333, Taiwan

Tel: +886-3-216-5088

Fax: +886-3-328-5723

Email: service@adlinktech.com

# Ampro ADLINK Technology, Inc.

Address: 6450 Via Del Oro, San Jose, CA 95119-1208, USA

Tel: +1-408-360-0200

Toll Free: +1-800-966-5200 (USA only)

Fax: +1-408-600-1189

Email: info@adlinktech.com

# ADLINK Technology (China) Co., Ltd.

Address: 300 Fang Chun Rd., Zhangjiang Hi-Tech Park, Pudong New Area Shanghai, 201203 China

Tel: +86-21-5132-8988

Fax: +86-21-5132-3588

Email: market@adlinktech.com

# ADLINK Technology GmbH

Address: Hans-Thoma-Strasse 8-10, 68163 Mannheim, Germany

Tel: +49-621-43214-0

Fax: +49-621 43214-30

Email: emea@adlinktech.com

Please visit the Contact page at www.adlinktech.com for information on how to contact the ADLINK regional office nearest you.
[🔗 Link to the original document](.axe-7420gwa-50m-22811-1000-02/axe-7420gwa-50m-22811-1000-02.pdf)