# MECS-7210

2U Edge Computing Server with Dual Intel® Xeon® Processor

# User’s Manual

![Front view of a black server rack with ports, connectors, and ventilation grilles (no visible text or labels)](.mecs-7210-50m-00013-1020-12/72739891e5af0223f5a3a7111952a8b3ff85fa930e101e1a233ffa9760b0a6f3.jpg)

Manual Rev.: Rev. 1.2

Revision Date: June 16, 2021

Part No.: 50M-00013-1020

# Preface

# Copyright © 2021 ADLINK Technology, Inc.

This document contains proprietary information protected by copyright. All rights are reserved. No part of this manual may be reproduced by any mechanical, electronic, or other means in any form without prior written permission of the manufacturer.

# Disclaimer

The information in this document is subject to change without prior notice in order to improve reliability, design, and function and does not represent a commitment on the part of the manufacturer.

In no event will the manufacturer be liable for direct, indirect, special, incidental, or consequential damages arising out of the use or inability to use the product or documentation, even if advised of the possibility of such damages.

# Environmental Responsibility

ADLINK is committed to fulfill its social responsibility to global environmental preservation through compliance with the European Union's Restriction of Hazardous Substances (RoHS) directive and Waste Electrical and Electronic Equipment (WEEE) directive. Environmental protection is a top priority for ADLINK. We have enforced measures to ensure that our products, manufacturing processes, components, and raw materials have as little impact on the environment as possible. When products are at their end of life, our customers are encouraged to dispose of them in accordance with the product disposal and/or recovery programs prescribed by their nation or company.

![Symbol of a trash bin crossed out by two diagonal lines (no text or numbers present)](.mecs-7210-50m-00013-1020-12/26878ed211d90dd113f630d9cf51589c6d7a038ccaf9e34c904a22d6ae674751.jpg)

![The image displays a black and white geometric design on a white background. It features a large central black rectangle. This central shape is flanked on the left by a thin vertical black bar and on the right by a thick vertical black bar. Horizontal black bars run across the top and bottom edges, connecting the left and right vertical bars. Additionally, two small black squares are positioned to the far left of the thin vertical bar, with one square aligned with the top horizontal bar and the other aligned with the bottom horizontal bar.](.mecs-7210-50m-00013-1020-12/11f67b77101e0bba251699ec25ccadb77cd2101cf09973d3e5a2bda87eceb895.jpg)

# Trademarks

Product names mentioned herein are used for identification purposes only and may be trademarks and/or registered trademarks of their respective companies.

Revision History

<table><tr><td>Revision</td><td>Release Date</td><td>Description of Change(s)</td></tr><tr><td>1.0</td><td>2020-12-18</td><td>Initial release</td></tr><tr><td>1.1</td><td>2021-02-25</td><td>Update specifications; add Enter BIOS section; update MTBF</td></tr><tr><td>1.2</td><td>2021-06-16</td><td>Add HDD/User LED settings and commands; correct SW2 settings; update command in “3.9.1 Updating the BIOS via Network with BMC Tool”; add BIOS content</td></tr></table>

# Conventions

![This image displays a standard warning sign featuring a yellow triangle with a black border. Inside the triangle is a black exclamation point. Below the triangle, the text 'CAUTION:' appears in black capital letters.](.mecs-7210-50m-00013-1020-12/a301bc95c4197342680d895361b7fa299dc0a30a24d8210dd76bc7369abf5aa0.jpg)

mise en garde

Information to prevent minor physical injury, component damage, data loss, and/or program corruption when trying to complete a task.

Informations destinées à prévenir les blessures corporelles mineures, les dommages aux composants, la perte de données et/ou la corruption de programme lors de l'exécution d'une tâche.

![The image displays a standard warning symbol consisting of a red triangle with rounded corners. Inside the triangle is a white exclamation point. Directly below the triangle, the word 'WARNING:' appears in black, capital letters.](.mecs-7210-50m-00013-1020-12/c89c82997c9abc3321e857cf76533831ea4fc724e5056741f8a6d22f3b133188.jpg)

AVERTISSEMENT

Information to prevent serious physical injury, component damage, data loss, and/or program corruption when trying to complete a specific task.

Informations destinées à prévenir les blessures corporelles graves, les dommages aux composants, la perte de données et/ou la corruption de programme lors de l'exécution d'une tâche spécifique.

# Table of Contents

# Preface ......

# 1 Overview ... 6

1.1 Introduction .. . 6
1.2 Block Diagram. 7
1.3 Mechanical Overview.. . 8

1.3.1 Front Panel .. ....8
1.3.2 Rear Panel.. ..8
1.3.3 Chassis Layout . ..9

1.4 Mechanical Dimensions . 10

# 2 Specifications ..... .11

2.1 MECS-7210 Specifications . ..11

# 3 Getting Started... .. 13

3.1 Removing the Chassis Cover .. . 13
3.2 Installing Memory Modules . . 14
3.3 PCIe Card Installation .. . 15

3.3.1 Single-Slot-Passive Cooled PCIe Cards . ...15
3.3.2 Fan Cooled or Dual-Slot Passive Cooled PCIe Cards . ...18

3.4 PCIe x16 Slot Secondary Power Supply.. .. 20
3.5 Connecting the System to Ground. .. 21
3.6 Login to the BMC via Console Port.. . 22
3.7 Login to the BMC via Network . . 24
3.8 BMC eth0 Default and Static IP Settings. .. 26
3.9 BIOS Update.. .. 27

3.9.1 Updating the BIOS via Network with BMC Tool.. ..27
3.9.2 Updating BIOS via Host with BIOS Tool.. ..28

3.10 BMC Firmware Update via Network. . 29
3.11 BMC Firmware Update via Host with Yafuflash.. . 30
3.12 Enter BIOS Setup . .. 31

# 4 System Interfaces.... . 32

4.1 Status LEDs . . 32

4.1.1 Power LED (green).. ..32
4.1.2 Alert LED (red)..... ..32
4.1.3 Drive Activity LED (yellow).. .32

4.2 LAN Ports... .. 33

4.3 SFP+ Ports.. . 34

4.3.1 SFP+ LED Behaviour ... ..34

4.4 Dual USB 3.0 and RJ-45 Console Port. .. 35
4.5 HDD/User LED Switch .. . 36
4.6 User LED Commands .

4.6.1 OEM ADLINK Set LED Status .. ..36
4.6.2 OEM ADLINK Get LED Status.. ..37

4.7 Board Layout.. . 38

# 5 BIOS Setup......... ... 39

5.1 BIOS Setup Menu . . 39

5.1.1 Menu Selection Bar .. ..39
5.1.2 Menu Conventions.. ..40

5.2 Main Menu .. . 40

5.2.1 BIOS Information . ..41
5.2.2 System Information.. ..41

5.3 Advanced Menu . 42

5.3.1 Sub-Menu: Serial Port Console Redirection.. ....43
5.3.2 Sub-Menu: Console Redirection Settings ......... ..44
5.3.3 Sub-Menu: Legacy Console Configuration... ..46
5.3.4 Sub-Menu: Network Stack Configuration .......... ..47
5.3.5 Sub-Menu: iSCSI Configuration .. ..48
5.3.6 Sub-Menu: Intel(R) I210 Gigabit Network Connection ...... ..49
5.3.7 Sub-Menu: NIC Configuration . ..50

5.4 Platform Configuration Menu . . 51

5.4.1 Sub-Menu: CPU Configuration. ..52
5.4.2 Sub-Menu: Memory Configuration... ..53
5.4.3 Sub-Menu: Memory Topology.. ..55
5.4.4 Sub-Menu: UPI Configuration.. ..56
5.4.5 Sub-Menu: UPI Status .. ..58
5.4.6 Sub-Menu: Memory Error Enabling. ..59
5.4.7 Sub-Menu: PCIe Error Enabling. ..60
5.4.8 Sub-Menu: Socket 0/1 Configuration .......... ..62
5.4.9 Sub-Menu: PCH SATA Configuration ........... ....63
5.4.10 Sub-Menu: SATA Mode options........ ....64

5.5 Server Mgmt Menu . . 65

5.5.1 Sub-Menu: BMC network Configuration.. ....66
5.5.2 Sub-Menu: BMC User Setting . ..67
5.5.3 Sub-Menu: Add User .. ..68
5.5.4 Sub-Menu: Delete User ... ..69
5.5.5 Sub-Menu: Change User Setting.. ..70

5.6 Security Menu . . 71

5.6.1 Sub-Menu: Secure Boot .. .... ....73
5.6.2 Sub-Menu: Key Management.. ....74

5.7 Boot Menu... . 75
5.8 Save & Exit Menu . 77

# Important Safety Instructions .................... ....... 78

# Consignes de Sécurité Importantes .... .. 80

# Getting Service ...... . 82

# 1 Overview

# 1.1 Introduction

The ADLINK MECS-7210 is a 2U 19" rackmount edge computing server with Intel® Xeon® Scalable processor and Intel® C620 series Chipset. The MECS-7210 features an IO intensive architecture with up to 2x PCIe x16 FHFL interfaces, 2x 2.5’’ SATA drive bays, 4x SFP+ ports, and is an ideal platform for 5G mobile edge computing infrastructure deployment.

The main features of the MECS-7210 are summarized as follows:

• Supports 2x FHFL PCIe x16 Gen 3 extension
16x DDR4 memory slots for up to 512GB memory to meet the requirement of network packet processing
• Up to 2x 2.5" external hot-swappable SATA drives, additional storage expansion via PCIe or M.2 NVMe (optional)
• Intelligent system management compatible with IPMI 2.0, supports SOL and adaptive fan speeds
Support for PacketManager software to provide data plane software stacks for dynamic layer 3 forwarding and flow-based forwarding, accelerating development of customer applications
Integrates Wind River® Titanium Server, and open source software including Intel® DPDK, Open vSwitch and nDPI, facilitating the building of packet parsing applications

# 1.2 Block Diagram

![Based on the provided flowchart, here is the accurate and concise description of the labeled blocks and their connections:\n\n**Labeled Blocks:**\n*   **M.2**\n*   **PSU**\n*   **Onboard Low-profile PCIe x8 slot**\n*   **Intel® C624 Chipset** (containing sub-blocks **3x QAT** and **PCH 4x10G**)\n*   **SKL EP CPU0 non-FPGA SKU**\n*   **SKL EP CPU1 non-FPGA SKU**\n*   **AST-2500**\n*   **SPI Flash**\n*   **I210** (two instances)\n*   **1x USB Socket**\n*   **RDIMM** (labeled 0 through 5)\n*   **UART SW**\n*   **RGB**\n*   **VGA Header**\n*   **PWR/RST Header**\n*   **SATA x3**\n*   **2x hot-swappable 2.5' SATA**\n*   **Console**\n*   **Alert LED**\n*   **HDD/APP LED**\n*   **PWR LED**\n*   **Reset**\n*   **HW**\n*   **LAN Port 0,1,3,4**\n*   **4x SFP+**\n*   **2x USB**\n*   **1x RJ45 (IPMI)**\n*   **1x RJ45**\n*   **USB 3.0 x2**\n*   **Full-size PCIe x16 slot (single-slot or dual-slot)** (two instances)\n*   **M.2** (two dashed instances)\n\n**Connections:**\n*   **M.2** connects via **SATA** to the **Intel® C624 Chipset**.\n*   **PSU** connects to the **Intel® C624 Chipset**.\n*   **PSU** (via fan icons) connects via **PCIe x8** to **SKL EP CPU0** and **Onboard Low-profile PCIe x8 slot**.\n*   **Intel® C624 Chipset** connects bidirectionally to **SKL EP CPU0** via **PCIe x16** and **DMIx4**.\n*   **SKL EP CPU0** connects bidirectionally to **SKL EP CPU1** via **UPI**.\n*   **SKL EP CPU0** connects to **RDIMM** blocks (0-5).\n*   **SKL EP CPU1** connects to **RDIMM** blocks (0-5).\n*   **SKL EP CPU0** connects via **PCIe x16** to a **Full-size PCIe x16 slot (single-slot or dual-slot)**.\n*   **SKL EP CPU0** connects via **PCIe x4** to an **M.2** slot.\n*   **SKL EP CPU1** connects via **PCIe x4** to an **M.2** slot.\n*   **SKL EP CPU1** connects via **PCIe x16** to a **Full-size PCIe x16 slot (single-slot or dual-slot)**.\n*   **Intel® C624 Chipset** connects bidirectionally to **AST-2500** via **NC-SI**, **IPMB/PECI/GPIO/...**, **USB**, **PCIe x1**, **UPC**, and **SPI Flash**.\n*   **AST-2500** connects to **SPI Flash** via **SPI**.\n*   **AST-2500** connects via **PWM/TACH** to the fan icons.\n*   **PCH 4x10G** (inside Chipset) connects to **I210** blocks, which then connect to **LAN Port 0,1,3,4**, **USB 3.0 x2**, **4x SFP+**, **2x USB**, **1x RJ45 (IPMI)**, and **1x RJ45**.\n*   **Intel® C624 Chipset** connects to **1x USB Socket**.\n*   **AST-2500** connects via **SATA x3** to **2x hot-swappable 2.5' SATA**.\n*   **AST-2500** connects to **UART SW**, which connects to **Console**.\n*   **AST-2500** connects to **RGB**, which connects to **VGA Header**, which connects to **PWR/RST Header**.\n*   **AST-2500** connects to **Alert LED**, **HDD/APP LED**, **PWR LED**, and **HW**.\n*   **PWR/RST Header** connects to **Reset**.](.mecs-7210-50m-00013-1020-12/41f25ee44d79b59542936a6664eec66bc1a23b969bbbddac123b0f773e4224fb.jpg)

# 1.3 Mechanical Overview

# 1.3.1 Front Panel

![SATA Drive\nBays x2\nLEDs\nConsole\nPort\nVGA\nPCIe Expansion Slots x2\nRJ45 x2 SFP+ x4\nUSB x2\nReset\nButton\nPower\nButton](.mecs-7210-50m-00013-1020-12/17f0c133446a7c34d699b95e947efddd9336638534dbfe8777d146aeaae6aec5.jpg)

# 1.3.2 Rear Panel

![Fans\nRedundant\nPower Supply](.mecs-7210-50m-00013-1020-12/2529bd94a54e53057de24ede0ff1f9057a1cd0b9e24b85f48e60c7cd07d716b6.jpg)

# 1.3.3 Chassis Layout

![PSU\nDDRS DIMM x16\nFans\nPCIe x16\nGen3\nFHFL x2\nM.2 SATA\nSlot\nUSB\nSATA Drive\nBays x2\nConsole Port Mode\nSwitch (SW2)](.mecs-7210-50m-00013-1020-12/f3cd05102e8cdb002916bbba3ec251a1c80a6ca0925763daa6e06f213e4480dc.jpg)

See 3.1 Removing the Chassis Cover on page 13 for instructions on removing the cover.

# 1.4 Mechanical Dimensions

![Units: mm\n423\nTop View\n438](.mecs-7210-50m-00013-1020-12/1c78d37cbae30167c0fda67f5158ae5a9df1078ce42afc369425fbc076c267a2.jpg)

![Front View\n480.60](.mecs-7210-50m-00013-1020-12/0d33bf50c0cea05440bcde5ae2da7719b0f5696313720016caf68c8ad33b8f8d.jpg)

# 2 Specifications

# 2.1 MECS-7210 Specifications

Main System

<table><tr><td>CPU</td><td>Intel® Xeon® Silver 4116 Processor 2.10 GHz (12C/24T, 85W) Intel® Xeon® Silver 4210 Processor 2.20 GHz (10C/20T, 85W) Intel® Xeon® Silver 4214 Processor 2.20 GHz (12C/24T, 85W) Intel® Xeon® Silver 4216 Processor 2.10 GHz (16C/32T, 100W) Intel® Xeon® Gold 6130 Processor 2.10 GHz (16C/32T, 125W) Intel® Xeon® Gold 6230 Processor 2.10 GHz (20C/40T, 125W) Intel® Xeon® Gold 6238T Processor 1.90 GHz (22C/44T, 125W) Note: Please contact your ADLINK representative for other processor SKUs.</td></tr><tr><td>L3 Cache</td><td>From 11MB to 24.75MB, dependent on processor</td></tr><tr><td>Chipset</td><td>Intel® C624/C627 Chipset</td></tr><tr><td>Memory</td><td>16x DDR4-2666 DIMM sockets, ECC, registered, up to 512GB</td></tr><tr><td>BIOS</td><td>AMI BIOS on SPI flash memory</td></tr><tr><td>Operating System</td><td>Windows 7 64-bit, Windows 10 64-bit, Windows Server 2016, Linux Kernel 2.6 and above</td></tr><tr><td>Intel® QuickAssist Technology</td><td>100Gb/s Intel® QAT support (optional)</td></tr><tr><td>Trusted Platform Module</td><td>TPM 1.2 (TPM 2.0 optional)</td></tr><tr><td>Chassis Management</td><td>IPMI v2.0 compliant with iKVM and SOL support</td></tr><tr><td>Software Support</td><td>Validated with DPDK, provides a high throughput for data plane packet processing</td></tr></table>

Interfaces

<table><tr><td>Expansion (SKU dependent)</td><td>2x PCIe x16 Gen3 FHFL single/dual-slot interface</td></tr><tr><td>Ethernet</td><td>2x RJ-45 10/100/1000BASE-T Ethernet ports4x 10G SFP+ Ethernet ports</td></tr><tr><td>Remote Console</td><td>1x RJ-45 serial port</td></tr><tr><td>USB</td><td>2x USB 3.0 (front panel)2x USB 3.0 (internal)</td></tr><tr><td>Graphics</td><td>1x VGA port</td></tr><tr><td>LEDs</td><td>Power, Alert, Drive Activity (user programmable)</td></tr></table>

Storage

<table><tr><td>Drive Bays</td><td>2x 2.5” external hot-swappable SATA 6 Gb/s drive bays</td></tr><tr><td>Internal</td><td>1x onboard M.2 2242 M key SATA 6 Gb/s slot2x M.2 2242/2280 NVMe slots (optional)</td></tr></table>

Mechanical & Environmental

<table><tr><td>Form Factor</td><td>2U 19” rackmount 438mm x 88mm x 420mm (W x H x D)</td></tr><tr><td>Fans</td><td>3 fans, adaptive speed</td></tr><tr><td>Power</td><td>800W or 1200W 1+1 redundant PSU100V to 240V AC @50-60Hz</td></tr><tr><td>Temperature $^{1}$ </td><td>Operating: -5°C 55°CStorage: -40°C to 70°C</td></tr><tr><td>Humidity $^{1}$ </td><td>Operating: 10% to 85% @40°C, non-condensingStorage: 5% to 90%, non-condensing</td></tr><tr><td rowspan="2">Shock $^{2}$ </td><td>Operating: half-sine 2G, 11ms pulse, 100 pulses on each of three axes</td></tr><tr><td>Non-operating: trapezoidal, 25G, 170 inches/sec delta V, three drops on each of three axes</td></tr><tr><td>Vibration</td><td>Non-operating: 2.2Grms, 10 minutes per axis on all three axes</td></tr><tr><td>Certifications</td><td>FCC Class A, CE emissions, UL, CB, CCC and RoHS compliant</td></tr><tr><td>MTBF</td><td>798789 hours @ 25°C (TBC)</td></tr></table>

# Notes:

1 Temperature and humidity specifications are valid only with ADLINK approved add-on devices, excluding hard drives and PCIe cards.
2 Shock and Vibration tests were conducted with WinFast RTX 2060 Super Classic graphics card installed.

# 3 Getting Started

# 3.1 Removing the Chassis Cover

Follow the instructions below to remove the chassis top cover.

![The image features a standard yellow triangular warning sign with a black border. Inside the triangle is a large black exclamation point. Below the triangle, the word 'CAUTION:' is written in black capital letters.](.mecs-7210-50m-00013-1020-12/45dd8c2b31e3172ec96e3ef9b2428b701208e737245d64b1f72fb40c9ebe02d1.jpg)
mise en garde

All installation procedures are restricted to qualified personnel.

Toutes les procédures d'installation sont réservées au personnel qualifié.

1. Remove the 2 screws on each side of the top cover (small arrows) and loosen the captive screw at the rear of the cover (circled).

![Diagram of a mechanical or electrical component with red arrows indicating directional flow, no text or symbols present.](.mecs-7210-50m-00013-1020-12/64f3221843dc8a67e09513935d5e1cdc5a1b08212368d1892a92eebde6dad0d7.jpg)

2. Press down on the two depressions with your thumbs and slide the cover towards the rear of the chassis (large arrows). Remove the cover.

To reinstall the cover, slide it towards the front of the chassis, then replace and tighten the screws loosened and removed in Step 1.

# 3.2 Installing Memory Modules

When installing memory modules in the MECS-7210, the blue DIMM slots of each channel can be freely populated (it is suggested to fill the slots from “outside to inside” for each CPU). However, the black DIMM slots must be populated after the blue DIMM slots are completely filled, otherwise the device will not boot up. Please refer to the figure below.

Note: The device will not boot up if the black DIMM slots are populated before the blue DIMM slots are completely filled.

![Blue\nBlue\nBlack\nCPU0\nBlack\nBlue\nBlue\nBlue\nBlue\nBlack\nCPU1\nBlack\nBlue\nBlue\nBlue\nBlue\nFCI\nFCI](.mecs-7210-50m-00013-1020-12/1ebf44fb07414f9adc85aac03550a3b97bbca6f408c4a09d086afd1541269fd7.jpg)

![The image displays a standard yellow triangular warning sign with a black exclamation point in the center. Below the triangle, the text reads 'CAUTION:' followed by the French phrase 'mise en garde'.](.mecs-7210-50m-00013-1020-12/51bffb6d245730ea94f4844c32fe5355f8465bef03ff66ac3994630bcbb3b7b2.jpg)

All installation procedures are restricted to qualified personnel. Toutes les procédures d'installation sont réservées au personnel qualifié.

# 3.3 PCIe Card Installation

Sample installation instructions for two types of PCIe expansion cards are described below. For detailed information on the PCIe daughter board and adapter brackets required for your cards and the specific installation procedures, please contact your ADLINK representative.

![The image displays a yellow triangular warning sign with a black border. Inside the triangle is a large black exclamation point. Below the triangle, the word 'CAUTION' is written in black capital letters.](.mecs-7210-50m-00013-1020-12/95f77185f5534df4e7ae49fa91bd0f004a7afc8dc07343f1268738cd80594b78.jpg)
mise en garde

All installation procedures are restricted to qualified personnel.

Toutes les procédures d'installation sont réservées au personnel qualifié.

# 3.3.1 Single-Slot-Passive Cooled PCIe Cards

Follow the instructions below to install single-slot-passive cooled PCIe expansion cards.

1. Remove the screw securing the bracket screw cover of the PCIe slot you wish to install an expansion card in.

![Front view of a server rack with multiple ports and connectors, showing two red-circled points of interest (no text or symbols visible)](.mecs-7210-50m-00013-1020-12/bdacd52f3e3f31fa9d8cfaa601f6a0948c5fecd4c1ed2437a07c8dfaa3854a32.jpg)

2. Rotate the bracket cover clockwise and remove the screw securing the PCIe bracket blanking plate.

![3D diagram of a server rack with hexagonal mesh and internal components, showing a red arrow indicating a component (no text or symbols present)](.mecs-7210-50m-00013-1020-12/1177ab26791cb5a2bcd715609c24da48abfc6fd1a789a63f3ee16214378f7f2e.jpg)

3. To install the single-slot-passive cooled PCIe expansion card, align the tab on the bracket with the opening on the rear I/O panel and insert the PCIe connectors into the slot on the daughter board. Make sure the connectors are fully inserted into the PCIe slot.

![H=14.47mm\nSingle slot](.mecs-7210-50m-00013-1020-12/e841e60c077986e847e28ace56f138bb8f2c6dfff5ee73f47f2dbdd603f1fbd2.jpg)

4. Secure the PCIe expansion card to the chassis using two screws as shown below.

![Single-slot\nH(=14.47mm](.mecs-7210-50m-00013-1020-12/9fd3bdb894cc139113bd71eb0022e4031ee8ff77d6ecd93968475ead603c7972.jpg)

5. Secure the PCIe expansion card bracket with the screw removed in Step 2, and rotate the bracket cover counter-clockwise.

![3D diagram of a server rack with hexagonal mesh and internal components, showing a red arrow indicating a component (no text or symbols present)](.mecs-7210-50m-00013-1020-12/c5ec3f556841c8a2d12b279c2c3623d8ec8bc7d680b44a080e0ada2bf025d224.jpg)

6. Replace the screw securing the bracket screw cover.

![3D rendering of a server rack with hexagonal mesh partition and indicator lights (no text or symbols visible)](.mecs-7210-50m-00013-1020-12/3023e806e029ffbb4f4b3ce87c160b4e9b71978acca00994b10a4b1c5f183004.jpg)

7. Repeat Steps 1 through 6 to install another single-slot-passive cooled PCIe expansion card.

# 3.3.2 Fan Cooled or Dual-Slot Passive Cooled PCIe Cards

Follow the instructions below to install single/dual-slot fan cooled or dual-slot passive cooled PCIe expansion cards.

1. Remove the I/O bracket from the PCIe expansion card.

![The image displays four 3D models arranged in a two-by-two grid.\n\n**Top Row:**\n*   **Left:** A grey graphics card featuring a fan shroud and the text 'QUADRO' on its side. A metal bracket is attached to the left end, highlighted by a red arrow pointing towards it.\n*   **Right:** A brown, rectangular block-like component mounted on a green circuit board. It also has a metal bracket on the left end, indicated by a red arrow.\n\n**Bottom Row:**\n*   **Left:** The same grey 'QUADRO' graphics card as above, but the metal bracket is missing, exposing the internal green circuit board at the end.\n*   **Right:** The same brown rectangular block as above, but without the metal bracket, showing the green circuit board base clearly.](.mecs-7210-50m-00013-1020-12/6c85f0e70b74a65de0d3e09e7569051e58ae68b1768bd6fd2b45d99703ef805e.jpg)

2. Turn the expansion card over and attach the adapter bracket with two screws.

![3D CAD model of a green NVIDIA CPU board with mounting holes and internal circuitry (no text or symbols visible)](.mecs-7210-50m-00013-1020-12/6442cf03f4425bdcfe8201dab7248cf317b0d1098436a5d73542da4fc65b5cdd.jpg)

![3D CAD model of a green NVIDIA CPU board with mounting holes and internal circuitry (no text or symbols)](.mecs-7210-50m-00013-1020-12/22dee191c4fc5c05b21518e49fcc9b9650f7972308c50aba1868a18d631a392d.jpg)

![3D CAD rendering of a quadro electronic device with green circuit board and fan (no text or symbols visible)](.mecs-7210-50m-00013-1020-12/98cc7497ae4127c072b8f81715cd66ce9bf92007779150d8132a934c447895cb.jpg)

![3D rendering of a brown rectangular electronic component mounted on a green base plate (no text or symbols visible)](.mecs-7210-50m-00013-1020-12/a6768c42c6ace0a650bffedd05e899760265008aedf6af61d5be16b47e8ac0fa.jpg)

3. If the PCIe expansion card is shorter than 312cm (full length size), attach the rear adapter bracket with two screws as shown.

![3D CAD model of a quadro electronic device with green connectors and mounting bracket (no text or symbols)](.mecs-7210-50m-00013-1020-12/a4667fd92e574a6d5d7e499b318a4ad6695945700598acdef1b13d3cbdff1de1.jpg)

4. Install the PCIe expansion card by inserting the PCIe connector into the slot on the daughter board. Make sure the connector is fully inserted into the PCIe slot.
5. Secure the PCIe expansion card to the chassis using four screws as shown below.

![Technical diagram of a computer motherboard showing internal components like CPU, RAM, and drive slots with red annotations highlighting specific areas.](.mecs-7210-50m-00013-1020-12/3b5de7c2c8448c3f2c9f5d27f2eebf8dedbd7cf0ed3447e75220c5cb4ab47d24.jpg)

# 3.4 PCIe x16 Slot Secondary Power Supply

The power supply on the MECS-7210 is equipped with two 8-pin ATX-type 12V power connectors to provide secondary power for PCIe x16 cards if required. Two break-out cables are also included. The pin definitions of the connectors and cables are described below.

# 8-pin ATX-type 12V Power Connector Pinout

<table><tr><td>Pin #</td><td>Signal</td><td>Pin #</td><td>Signal</td></tr><tr><td>1</td><td>COM</td><td>5</td><td>+12V</td></tr><tr><td>2</td><td>COM</td><td>6</td><td>+12V</td></tr><tr><td>3</td><td>COM</td><td>7</td><td>+12V</td></tr><tr><td>4</td><td>COM</td><td>8</td><td>+12V</td></tr></table>

![4\n8\n1\n5](.mecs-7210-50m-00013-1020-12/82f2ef8bdffc23f5eb42657d05abd6ce92915451ccfffb7076145f2d012016c5.jpg)

# Breakout Cable Connector Pinout

![P1 1 5\n4 8\nP3 4 1\n6 3\n#2 #1\nP2 #1 #2\n3 6\n1 4](.mecs-7210-50m-00013-1020-12/61d082fc956f05230c7beb74c75118928e993df877cf9febec05c770d6f889dc.jpg)

Pinout
![Based on the provided block diagram, here are the labeled blocks and their connections:\n\n**Labeled Blocks:**\n*   **Column P1:** 1, 2, 3, 4, 5, 6, 7, 8\n*   **Column P2:** 1, 2, 3, #1, #2, 4, 5, 6\n*   **Column P3:** 1, 2, 3, #1, #2, 4, 5, 6\n\n**Connections:**\n*   **1 (P1)** connects to **1 (P2)** and **1 (P3)**.\n*   **2 (P1)** connects to **2 (P2)** and **2 (P3)**.\n*   **3 (P1)** connects to **3 (P2)** and **3 (P3)**.\n*   **4 (P1)** splits into two paths:\n    *   One path connects to **#1 (P2)**, which then connects to **#1 (P3)**.\n    *   One path connects to **#2 (P2)**, which then connects to **#2 (P3)**.\n*   **5 (P1)** connects to **4 (P2)** and **4 (P3)**.\n*   **6 (P1)** connects to **5 (P2)** and **5 (P3)**.\n*   **7 (P1)** connects to **6 (P2)**.\n*   **8 (P1)** connects to **6 (P3)**.](.mecs-7210-50m-00013-1020-12/2c233e9bd6924f016ad7b4c7809c7c19cf6dae1b808b88ecaa4e8746658e95c4.jpg)

![The image features a yellow triangular warning sign with a black border and a black exclamation point in the center. Below the triangle, the word 'CAUTION:' is written in black capital letters, followed by the partially visible text 'mise en garde'.](.mecs-7210-50m-00013-1020-12/a76126998d177f25634c2a12f37311ef2c9b824c54f42d36c69aff5d9046f8a5.jpg)

All installation procedures are restricted to qualified personnel. Toutes les procédures d'installation sont réservées au personnel qualifié.

# 3.5 Connecting the System to Ground

The MECS-7210 is connected to ground by the ground pin of the 3-prong IEC power cord. Please use the power cord provided with the system for your region.

A grounding stud (M3 size) is provided on the rear of the chassis for additional connection to ground.

![800W\n94%\n800W\n94%\nGrounding\nStud](.mecs-7210-50m-00013-1020-12/3eacb3a2485a5c268a4e3c61380ccfe0d95cfe900e6de9c429622b69d595236c.jpg)

# 3.6 Login to the BMC via Console Port

# Step 1

Set the Console Port to BMC mode using the 4-pole DIP Console Port Mode Switch (SW2) on the I/O board (see 1.3.3 Chassis Layout on page 9).

<table><tr><td>Pin</td><td>Default</td><td>BMC Debug</td></tr><tr><td>1</td><td>OFF</td><td>ON</td></tr><tr><td>2</td><td>ON</td><td>OFF</td></tr><tr><td>3</td><td>OFF</td><td>ON</td></tr><tr><td>4</td><td>ON</td><td>OFF</td></tr></table>

# Step 2

Use the included RJ-45 to DB-9 console port adapter cable to connect the PC to the RJ-45 console port of the MECS-7210 (circled below). Refer to 4.4 Dual USB 3.0 and RJ-45 Console Port on page 35 for the adapter cable pin definition.

![Exterior view of a beige USB connector with terminal connectors (no text or symbols visible)](.mecs-7210-50m-00013-1020-12/0ec770bd1c90c9d0b4f938bbf4a6649bb593ab696b82b7bc7388642e5c8a850f.jpg)

![HDD 1\nHDD 2\n1 SPF+ 3\nIOI0I\nVGA\nPWR RST](.mecs-7210-50m-00013-1020-12/41928d34fb704a00bb1ef350250af76df19193358f3b11ea435d39bbf043c14b.jpg)

# Step 3

Open a serial port console tool (such as PuTTY), choose the higher COM port (it may be different depending on your computer), then set the baud rate to 115200.

![PuTTY Configuration\nCategory:\nSession\nLogging\nTerminal\nKeyboard\nBell\nFeatures\nWindow\nAppearance\nBehaviour\nTranslation\nSelection\nColours\nConnection\nData\nProxy\nTelnet\nRlogin\nSSH\nSerial\nBasic options for your PuTTY session\nSpecify the destination you want to connect to\nSerial line Speed\nCOM3 115200\nConnection type:\nRaw Telnet Rlogin SSH Serial\nLoad, save or delete a stored session\nSaved Sessions\nCOM3\nDefault Settings\n2600T\n2600_CPU_Server\n2610T\n2610T_board\nCOM3\nCSA-7400\nLoad\nSave\nDelete\nClose window on exit:\nAlways Never Only on clean exit\nAbout Help Open Cancel](.mecs-7210-50m-00013-1020-12/fe0643ee7d6ab544104ed4261e7000cb2960f413e47a4915339bf9e7e4dc2714.jpg)

# Step 3

Input the user name “sysadmin” and password “superuser” to login to the system.

![AMI00306425F122 login: sysadmin\nPassword:\nlogin(1773): pam_unix(login:account): account sysadmin has password changed in future\nlogin(1773): pam_unix(login:session): session opened for user sysadmin by LOGIN(uid=0)\n(1773 INFO)SERIAL Login from IP:127.0.0.1 user:sysadmin\n\nlogin(1773): (1773 INFO)SERIAL Login from IP:127.0.0.1 user:sysadmin\n\nlogin(1773): root login on 'ttyS4'\n~ #](.mecs-7210-50m-00013-1020-12/da8330d59636932c1a6e99a65198f1ff0bb924fa3123370b0b97510130320908.jpg)

# 3.7 Login to the BMC via Network

# Step 1

Connect the LAN cable to left RJ-45 LAN port (eth0, circled below);

![HDD 1\nHDD 2\nIOIOI\n1 SPF+ 3\nVGA\nPWR RST](.mecs-7210-50m-00013-1020-12/b8cae6acfd8709548bead3ba07a9183e3e77ca59fdca0e00f6ae4e54bdb2aa63.jpg)

# Step 2

Open a serial port console tool (such as PuTTY) enter the IP address, and open a connection to the BMC (login using serial console first to check the IP address).

![PuTTY Configuration (Save mode : File)\nCategory:\nSession\nLogging\nTerminal\nKeyboard\nBell\nFeatures\nExtraPuTTY\nSettings\nStatusBar\nFilesTransfer\nWindow\nAppearance\nBehaviour\nTranslation\nBasic options for your PuTTY session\nSpecify the destination you want to connect to\nHost Name (or IP address)	Port\n10.0.0.7	22\nConnection type:\nRaw	Telnet	Rlogin	SSH	Serial\nCygtem\nLoad, save or delete a stored session\nSaved Sessions\nDefault Settings\n2080\ncom-30400\ncom-6150\nremote\nvm\nLoad\nClose window on exit:\nAlways	Never	Only on clean exit\nNever, Auto-Connect\nAbout	Open	Cancel](.mecs-7210-50m-00013-1020-12/671e8142d8e056be5aadaa3c4a5b37882e2c1ea0e91abb04af3c332eb1dd9523.jpg)

# Step 3

Input the user name “sysadmin” and password “superuser” to login to the system

![login as: sysadmin\nsysadmin@10.0.0.7's password:\n~ #\n~ #](.mecs-7210-50m-00013-1020-12/0be787698b3e42ff64fb50fa86397e987bb7045db725e5d731d80f15e8cdc57d.jpg)

# 3.8 BMC eth0 Default and Static IP Settings

The default IP setting is DHCP. Users can login to the BMC to modify the IP.

# Static IP Settings

Ipmitool -I lan -H 127.0.0.1 -U admin -P admin raw 0x0c 0x01 0x01 0x0 0x1 # start config

Ipmitool -I lan -H 127.0.0.1 -U admin -P admin raw 0x0c 0x01 0x01 0x4 0x1 # set IP to static mode

Ipmitool -I lan -H 127.0.0.1 -U admin -P admin raw 0x0c 0x01 0x01 0x3 0xac 0x14 0x5 0xe8 # set IP, the last four bytes is IP in hex, here is 172.20.5.232

Ipmitool -I lan -H 127.0.0.1 -U admin -P admin raw 0xc 0x1 0x1 0x6 0xff 0xff 0xff 0x0 #Change Mask to 255.255.255.0

Ipmitool -I lan -H 127.0.0.1 -U admin -P admin raw 0x0c 0x01 0x01 0xC 0xac 0x14 0x5 0xfe # set Gateway, the last four bytes, here is 172.20.5.254

Ipmitool -I lan -H 127.0.0.1 -U admin -P admin raw 0x0c 0x01 0x01 0x0 0x0 # set complete DHCP setting:

Ipmitool -I lan -H 127.0.0.1 -U admin -P admin raw 0x0c 0x01 0x01 0x0 0x1 # start config

Ipmitool -I lan -H 127.0.0.1 -U admin -P admin raw 0x0c 0x01 0x01 0x4 0x2 # set IP to DHCP mode

Ipmitool -I lan -H 127.0.0.1 -U admin -P admin raw 0x0c 0x01 0x01 0x0 0x0 # set complete

# 3.9 BIOS Update

Users can update the MECS-7210 system BIOS over various interfaces (Gigabit LAN, KCS, console port).

# 3.9.1 Updating the BIOS via Network with BMC Tool

1. Install a Linux distribution, such as Ubuntu 14, to the debug PC.
2. Install “expect” to your debug PC (ex: sudo apt-get install expect).
3. Copy the BMC FW package “BMC\_MECS-7210\_Release\_Vx.xx” to the debug PC;

# Upgrade Procedure:

1. Check the IP of the BMC of MECS-7210. Power on the MECS-7210, boot the BMC to Linux (username: sysadmin; Passwd: superuser), and type “ifconfig” check its IP address.

```txt
AMI72696679006E login:
AMI72696679006E login: sysadmin
Password:
login[1623]: pam_unix(login:session): session opened for user sysadmin by LOGIN(uid=0)
[1623 INFO]SERIAL Login from IP:127.0.0.1 user:sysadmin

login[1623]: [1623 INFO]SERIAL Login from IP:127.0.0.1 user:sysadmin

login[1623]: root login on 'ttyS4'
~ #
~ #
~ # ifconfig

eth0 Link encap:Ethernet HWaddr 72:69:66:79:00:6E
inet addr:172.20.5.77 Bcast:172.20.5.255 Mask:255.255.255.0
inet0 addr: fe80::1009.66ff:fe79:6e/64 Scope:Link
UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1
RX packets:191 errors:0 dropped:5 overruns:0 frame:0
TX packets:58 errors:0 dropped:0 overruns:0 carrier:0
collisions:0 txqueuelen:1000
RX bytes:21025 (20.5 KiB) TX bytes:8142 (7.9 KiB)
Interrupt:2

eth1 Link encap:Ethernet HWaddr 01:C0:A8:12:36:57
inet6 addr: fe80::1c0:a800:112:3657/64 Scope:Link
UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1
RX packets:0 errors:0 dropped:0 overruns:0 frame:0
TX packets:44 errors:0 dropped:0 overruns:0 carrier:0
collisions:0 txqueuelen:1000
RX bytes:0 (0.0 B) TX bytes:10332 (10.0 KiB)
Interrupt:3
```

2. On the debug PC, execute the following commands to perform the upgrade.

cd BMC\_MECS-7210\_Release\_Vx.xx

cd BIOS

./adlinktool.sh upgradebios1 BIOS\_xxxx.bin 172.20.5.77

Note: Only “bin” files are supported when updating the BIOS via Network.

# 3.9.2 Updating BIOS via Host with BIOS Tool

1. Boot/Login to Shell
2. Update the BIOS over host with the following commands.

Example:

AfuEfix64 BIOS.ROM /p /b /n /k (to update BIOS without ME) AfuExfi64 BIOS.BIN /p /b /n /k /me (to update the entire BIOS)

![fs0:\MECS7210) dir\nDirectory of: fs0:\MECS7210\n\n04/06/20 05:44p (DIR) 4,096 .\n04/06/20 05:44p (DIR) 0 ..\n01/14/20 03:22p 505,968 AfuEf ix64.efi\n01/14/20 03:22p 7,360 HISTORY.txt\n01/14/20 03:22p 33,554,432 MECS-7210_00210.BIN\n01/14/20 03:22p 16,777,216 MECS-7210_00210.ROM\n01/14/20 03:22p 402 pBIOS.nsh\n02/14/20 04:04p 403 pSPI.nsh\n6 File(s) 50,845,781 bytes\n2 Dir(s)\n\nfs0:\MECS7210)](.mecs-7210-50m-00013-1020-12/c89b02d96827abdc9ce3652cc16ffcefef197284f49d6145d70fc4b5ec88650d.jpg)

# 3.10 BMC Firmware Update via Network

The MECS-7210 supports a BMC Chassis Management firmware, IPMI v2.0 compliant. To install the BMC firmware via network, perform the following steps.

1. Install a Linux distribution, such as Ubuntu 14, to the debug PC.
2. Install “expect” to your debug PC (ex: sudo apt-get install expect).
3. Copy the BMC FW package “BMC\_MECS-7210\_Release\_Vx.xx” to the debug PC;

# Upgrade Procedure:

1. Check the IP of the BMC of MECS-7210. Power on the MECS-7210, boot the BMC to Linux (username: sysadmin; Passwd: superuser), and type “ifconfig” check its IP address.

```txt
AMI72696679006E login:
AMI72696679006E login: sysadmin
Password:
login[1623]: pam_unix(login:session): session opened for user sysadmin by LOGIN(uid=0)
[1623 INFO]SERIAL Login from IP:127.0.0.1 user:sysadmin

login[1623]: [1623 INFO]SERIAL Login from IP:127.0.0.1 user:sysadmin

login[1623]: root login on 'ttyS4'
~ #
~ #
~ # ifconfig

eth0 Link encap:Ethernet HWaddr 72:69:66:79:00:6E
inet addr:172.20.5.77 Bcast:172.20.5.255 Mask:255.255.255.0
ineto addr: fe80..1009.66ff:fe79:6e/64 Scope:Link
UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1
RX packets:191 errors:0 dropped:5 overruns:0 frame:0
TX packets:58 errors:0 dropped:0 overruns:0 carrier:0
collisions:0 txqueuelen:1000
RX bytes:21025 (20.5 KiB) TX bytes:8142 (7.9 KiB)
Interrupt:2

eth1 Link encap:Ethernet HWaddr 01:C0:A8:12:36:57
inet6 addr: fe80::1c0:a800:112:3657/64 Scope:Link
UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1
RX packets:0 errors:0 dropped:0 overruns:0 frame:0
TX packets:44 errors:0 dropped:0 overruns:0 carrier:0
collisions:0 txqueuelen:1000
RX bytes:0 (0.0 B) TX bytes:10332 (10.0 KiB)
Interrupt:3
```

2. On the debug PC, execute the following commands to perform the upgrade.

cd BMC\_MECS-7210\_Release\_Vx.xx

cd FW

./adlinktool.sh bmc1 rom.ima 172.20.5.77

# 3.11 BMC Firmware Update via Host with Yafuflash

The MECS-7210 supports a BMC Chassis Management firmware, IPMI v2.0 compliant. To update the BMC firmware via host with Yafuflash, perform the following steps.

1. Login to the OS with root user permission.
2. Update the BMC over host using the commands below:

Example:

\$ sudo ./Yafuflash -kcs rom.ima

YAFUFlash - Firmware Upgrade Utility (Version 4.117.7)

(C)Copyright 2016, American Megatrends Inc. The Module root allocated size is different from the one in the Image So,Type (Y/y) to do Full Firmware Upgrade or (N/n) to exit Enter your Option : Y

\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*

WARNING!

FIRMWARE UPGRADE MUST NOT BE INTERRUPTED ONCE IT IS STARTED. PLEASE DO NOT USE THIS FLASH TOOL FROM THE REDIRECTION CONSOLE.

<table><tr><td>Upl oading Firmware Image : 100%... done</td></tr><tr><td>Ski pping [boot] Module ....</td></tr><tr><td>Flashing [conf] Module ....</td></tr><tr><td>Flashing Firmware Image : 100%... done</td></tr><tr><td>Veri fying Firmware Image : 100%... done</td></tr><tr><td>Flashing [root] Module ....</td></tr><tr><td>Flashing Firmware Image : 100%... done</td></tr><tr><td>Veri fying Firmware Image : 100%... done</td></tr><tr><td>Flashing [osimage] Module ....</td></tr><tr><td>Flashing Firmware Image : 100%... done</td></tr><tr><td>Veri fying Firmware Image : 100%... done</td></tr><tr><td>Flashing [www] Module ....</td></tr><tr><td>Flashing Firmware Image : 100%... done</td></tr><tr><td>Veri fying Firmware Image : 100%... done</td></tr><tr><td>Flashing [testapps] Module ....</td></tr><tr><td>Flashing Firmware Image : 100%... done</td></tr><tr><td>Veri fying Firmware Image : 100%... done</td></tr><tr><td>Flashing [ast2500e] Module ....</td></tr><tr><td>Flashing Firmware Image : 100%... done</td></tr><tr><td>Veri fying Firmware Image : 100%... done</td></tr><tr><td>Resetting the firmware....</td></tr></table>

Open IPMI Drivers

Loading Open IPMI Driver:ipmi\_devintf BMC is booting up, Please load ipmi\_si Open IPMI Driver after the BMC Boots up!!!! Loading Open IPMI Driver:ipmi\_msghandler

# 3.12 Enter BIOS Setup

To enter the BIOS setup screen, follow these steps:

1. Power on the MECS-7210.
2. Press the &lt;Delete&gt; or &lt;ESC&gt; key on your keyboard when you see the following text prompt: “Press DEL or ESC to enter Setup” .

(Note: If Quick Boot is enabled, the screen below will not display, but pressing the &lt;Delete&gt; or &lt;ESC&gt; key will still allow you to enter the BIOS setup screen.)

![American\nMegatrends\nwww.ami.com\nVersion 2.20.1275. Copyright (C) 2020 American Megatrends, Inc.\nMECS-7210 REV:0.06.10\nPress (DEL) or (ESC) to enter setup.](.mecs-7210-50m-00013-1020-12/faad14ab3a1b79b6df40430f8aa1270bee1e0ea066a110a0b68119912a2445cb.jpg)

3. After pressing the &lt;Delete&gt; or &lt;ESC&gt; key, the main BIOS setup menu will display. You can access the other setup screens from the main BIOS setup menu, such as Chipset and Power menus.

# 4 System Interfaces

![SATA Drive\nBays x2\nConsole\nPort\nVGA\nPower LED\nAlert LED\nHDD LED\n1 QE 2\n1\n3\n10Ω\nRJ45 x2\n2 SFP+ x4\nUSB x2\nVGA\nPWR RST\nReset\nButton\nPower\nButton](.mecs-7210-50m-00013-1020-12/95a20eade2176c7a349595d8568996a3e464160654b07c797ebeb1c6c222f510.jpg)

# 4.1 Status LEDs

# 4.1.1 Power LED (green)

The Power LED will light in boot up state.

# 4.1.2 Alert LED (red)

The LED will light when a BIOS failure is detected or a sensor reading exceeds its upper/lower un-recoverable threshold.

# 4.1.3 Drive Activity LED (yellow)

The Drive Activity (HDD) LED is controlled by SATALED# from the chipset. When SATA storage is active (read/write), the LED will blink.

Note: This LED can also be user defined. Refer to 4.5 HDD/User LED and 4.6 User LED Commands on page 36.

# 4.2 LAN Ports

<table><tr><td>Pin #</td><td>Signal</td></tr><tr><td>1</td><td>MDI_P0</td></tr><tr><td>2</td><td>MDI_N0</td></tr><tr><td>3</td><td>MDI_P1</td></tr><tr><td>4</td><td>MDI_N1</td></tr><tr><td>5</td><td>MDI_P2</td></tr><tr><td>6</td><td>MDI_N2</td></tr><tr><td>7</td><td>MDI_P3</td></tr><tr><td>8</td><td>MDI_N3</td></tr></table>

![LED1\nLED2\n8\n1](.mecs-7210-50m-00013-1020-12/55f50b7e3d57b42afcc2817af5f303d4e94bbe926dff0d153f576ca2de20bee7.jpg)

# LAN LED Behaviour

The LAN LEDs are integrated into the RJ-45 connector. Their behavior is as follows:

<table><tr><td colspan="2">LED1 (Speed)</td></tr><tr><td>10 Mbps</td><td>Off</td></tr><tr><td>100 Mbps</td><td>Green</td></tr><tr><td>1000 Mbps</td><td>Orange</td></tr></table>

The LED2 (Link/Activity) indicates that a link has been established by lighting orange. When data is transmitted the LED blinks orange.

<table><tr><td colspan="2">LED2 (Link/Activity)</td></tr><tr><td>Link with no activity</td><td>Steady</td></tr><tr><td>Link with activity</td><td>Blinking</td></tr></table>

# 4.3 SFP+ Ports

<table><tr><td>Pin</td><td>Signal Name</td></tr><tr><td>1</td><td>GND</td></tr><tr><td>2</td><td>TX_FAULT</td></tr><tr><td>3</td><td>TX_DSBL</td></tr><tr><td>4</td><td>SDA</td></tr><tr><td>5</td><td>SCL</td></tr><tr><td>6</td><td>MOD_ABS</td></tr><tr><td>7</td><td>RS0</td></tr><tr><td>8</td><td>RX_,OS</td></tr><tr><td>9</td><td>RS1</td></tr><tr><td>10</td><td>GND</td></tr><tr><td>11</td><td>GND</td></tr><tr><td>12</td><td>RD-</td></tr><tr><td>13</td><td>RD+</td></tr><tr><td>14</td><td>GND</td></tr><tr><td>15</td><td>VCCR</td></tr><tr><td>16</td><td>VCCT</td></tr><tr><td>17</td><td>GND</td></tr><tr><td>18</td><td>TX+</td></tr><tr><td>19</td><td>TX-</td></tr><tr><td>20</td><td>GND</td></tr></table>

![20\n11\n1\n10](.mecs-7210-50m-00013-1020-12/e0cafc61c815cfe320fc74a83b574b83ee89552dbdb24a603981041612335510.jpg)

# 4.3.1 SFP+ LED Behaviour

![Link\nStatus\nLink\nActivity](.mecs-7210-50m-00013-1020-12/c6f1a7f0784a0b4e6ca8e6e9c2c307c3c1b06cc128c7eefb0c4a6d483509184d.jpg)

The LEDs point to the respective port.

<table><tr><td>LED</td><td>Status</td><td>Behavior</td></tr><tr><td rowspan="2">Link Status</td><td>Link up</td><td>Yellow (steady)</td></tr><tr><td>Link down</td><td>Off</td></tr><tr><td rowspan="2">Link Activity</td><td>Active</td><td>Green (blinking)</td></tr><tr><td>Not active</td><td>Off</td></tr></table>

# 4.4 Dual USB 3.0 and RJ-45 Console Port

<table><tr><td>Pin</td><td>Signal Name</td></tr><tr><td>R1</td><td>N/C</td></tr><tr><td>R2</td><td>N/C</td></tr><tr><td>R3</td><td>COM_TXD</td></tr><tr><td>R4</td><td>GND</td></tr><tr><td>R5</td><td>GND</td></tr><tr><td>R6</td><td>COM_RXD</td></tr><tr><td>R7</td><td>N/C</td></tr><tr><td>R8</td><td>N/C</td></tr><tr><td>U1</td><td>5V</td></tr><tr><td>U2</td><td>USB2_N</td></tr><tr><td>U3</td><td>USB2_P</td></tr><tr><td>U4</td><td>GND</td></tr><tr><td>U5</td><td>SSRX_N</td></tr><tr><td>U6</td><td>SSRX_P</td></tr><tr><td>U7</td><td>GND</td></tr><tr><td>U8</td><td>SSTX_N</td></tr><tr><td>U9</td><td>SSTX_P</td></tr><tr><td>U10</td><td>5V</td></tr><tr><td>U11</td><td>USB2_N</td></tr><tr><td>U12</td><td>USB2_P</td></tr><tr><td>U13</td><td>GND</td></tr><tr><td>U14</td><td>SSRX_N</td></tr><tr><td>U15</td><td>SSRX_P</td></tr><tr><td>U16</td><td>GND</td></tr><tr><td>U17</td><td>SSTX_N</td></tr><tr><td>U18</td><td>SSTX_P</td></tr></table>

![R8\nR1\nU18\nU14\nU13\nU10\nU10\nU9\nU5\nU9\nU5\nU1\nU4](.mecs-7210-50m-00013-1020-12/958cc1d30acacdfcda9bfd24811f9be59b0d522234eef09f982a060da96798fd.jpg)

The MECS-7210 comes with an RJ-45 to DB-9 console port adapter cable.

![9\n1\nA\nB\nB向\n1](.mecs-7210-50m-00013-1020-12/4c53207f9f1ed0d1998cb89b634c73c39d9ec00733403973b54277d767ff527f.jpg)

<table><tr><td>DB-9 Pin</td><td>Signal</td></tr><tr><td>1</td><td>—</td></tr><tr><td>2</td><td>RXD</td></tr><tr><td>3</td><td>TXD</td></tr><tr><td>4</td><td>DTR</td></tr><tr><td>5</td><td>SG</td></tr><tr><td>6</td><td>DSR</td></tr><tr><td>7</td><td>RTS</td></tr><tr><td>8</td><td>CTS</td></tr><tr><td>9</td><td>—</td></tr></table>

# 4.5 HDD/User LED Switch

The HDD/User LED Switch (SW1) can be used to set the function of the Drive Activity LED (default is Drive Activity).

<table><tr><td>LED Function</td><td>Pin 1</td><td>Pin 2</td></tr><tr><td>HDD Activity</td><td>ON</td><td>OFF</td></tr><tr><td>User Defined</td><td>OFF</td><td>ON</td></tr></table>

The HDD/User LED Switch (SW1) is located under the SATA drive bays as shown below. Remove the SATA Drive Bays and open the chassis cover to access SW1 (see 3.1 Removing the Chassis Cover on page 13).

![Interior view of an electronic device showing a green circuit board with multiple microphones and a red circle highlighting a component (no visible text or symbols)](.mecs-7210-50m-00013-1020-12/4ac77b040c35d232fd612636449856fad17425009374c6ea9e8a0f768bc8bcaf.jpg)

# 4.6 User LED Commands

# 4.6.1 OEM ADLINK Set LED Status

NetFn=2Eh, Cmd=10h

<table><tr><td>Byte</td><td>Data Field</td></tr><tr><td>1~3</td><td>ADLINK Manufacturer ID -005F13h, LS byte first.</td></tr><tr><td>4</td><td>LED ID:01h= Alert LED (red)02h = App LED (yellow)Other values: reserved</td></tr><tr><td>5</td><td>LED Function:00h = LED OFF override.01h - 1Eh = LED BLINKING override. The off duration is specified by the value of this byte, and the on duration is specified by the value of byte 5. Both values specify the time in hundreds of milliseconds (100 ms-3 s).1Fh = LED state is restored to Local Control state20h-FEh ReservedFF = LED ON override</td></tr><tr><td>6</td><td>On-duration:The LED on-time in hundreds of milliseconds if (01h Byte 6 1Eh) and ignored otherwise.Otherwise, this field is ignored and is set to 0h.</td></tr><tr><td></td><td>Response Field</td></tr><tr><td>1</td><td>Completion Code</td></tr><tr><td>2-4</td><td>ADLINK Manufacturer ID – 005F13h, LS byte first.</td></tr></table>

# 4.6.2 OEM ADLINK Get LED Status

NetFn=2Eh, Cmd=11h

<table><tr><td>Byte</td><td>Data Field</td></tr><tr><td>1-3</td><td>ADLINK Manufacturer ID – 005F13h, LS byte first.</td></tr><tr><td>4</td><td>LED ID:01h= Alert LED (Red)02h = App LED (Yellow)Other values: reserved</td></tr><tr><td></td><td>Response Field</td></tr><tr><td>1</td><td>Completion Code</td></tr><tr><td>2-4</td><td>ADLINK Manufacturer ID D of ran, LS byte first.</td></tr><tr><td>5</td><td>LED ID:01h= Alert LED (Red)02h = App LED (Yellow)Other values: reserved</td></tr><tr><td>6</td><td>LED Function:00h = LED OFF override.01h - 1Eh = LED BLINKING override. The off duration is specified by the value of this byte, and the on duration is specified by the value of byte 7. Both values specify the time in hundreds of milliseconds (100 ms-3 s).1Fh = LED is in Local Control state20h-FEh ReservedFF = LED ON override</td></tr><tr><td>7</td><td>On-duration :The LED on-time in hundreds of milliseconds if (01h Byte 6 1Eh) and ignored otherwise set to 0h.</td></tr></table>

# 4.7 Board Layout

![H\nK\nE\nG\nD\nC\nJ\nB\nF\nA](.mecs-7210-50m-00013-1020-12/9192f4b61920949d8fb68f1184329a79477f131f12a2c8406cdd60f50c46638a.jpg)

<table><tr><td>A</td><td>CPU0</td><td>G</td><td>PCIe x8 slot</td></tr><tr><td>B</td><td>CPU1</td><td>H</td><td>SATA Port</td></tr><tr><td>C</td><td>PCH</td><td>I</td><td>NIM slot</td></tr><tr><td>D</td><td>BMC Chip</td><td>J</td><td>PWR CONN</td></tr><tr><td>E</td><td>CPLD Chip</td><td>K</td><td>B2B for Daughter Board</td></tr><tr><td>F</td><td>DDR4 DIMM</td><td></td><td></td></tr></table>

# 5 BIOS Setup

# 5.1 BIOS Setup Menu

The BIOS setup utility is invoked by pressing &lt;ESC&gt; or &lt;DEL&gt; keys. User can change BIOS settings during setup utility runs. A system reset is required for new settings to take effect.

In the BIOS setup utility, there are several hot keys are designed for specific purposes, as listed below.

&lt;F1&gt;: General help in setup menu
&lt;F8&gt;: Load previous BIOS values
&lt;F9&gt;: Load BIOS default in setup utility
&lt;F10&gt;: Save & Exit setup utility

To navigate through the BIOS setup menu, use the following.

<table><tr><td>→←</td><td>Left/Right. The Left and Right &lt; Arrow &gt; keys allow you to select a setup screen.For example: Main screen, Advanced screen, Chipset screen, and so on.</td></tr><tr><td>↑↓</td><td>Up/Down The Up and Down &lt; Arrow &gt; keys allow you to select a setup item or sub-screen.</td></tr><tr><td>+-</td><td>Plus/Minus The Plus and Minus &lt; Arrow &gt; keys allow you to change the field value of a particular setup item.For example: Date and Time.</td></tr><tr><td>Tab</td><td>The &lt; Tab &gt; key allows you to select setup fields.</td></tr></table>

# 5.1.1 Menu Selection Bar

The Menu Selection Bar is located at the top of the screen. It displays the top level available menus to the user:

• Main Menu
Advanced Menu
• Platform Configuration Menu
• Server Mgmt
• Security Menu
Boot Menu
Save & Exit Menu

# 5.1.2 Menu Conventions

The appearance of the setup menu listed in this chapter is a sample to describe the item list. It is shown on a VT100 terminal via serial console. The menu conventions are as follows.

# Using color

The mandatory BIOS setup fields are in black. The BIOS setup fields currently not used are in grey. The display only strings are in black.

# Using brackets

Editable menu options are marketed with squares ‘[‘ and ‘]’ to distinguish them from display only fields that can’t be modified.

# 5.2 Main Menu

The Main Menu provides read-only information about the system and also allows you to set the system date and time. The tables below show screen shots of the Main menu details, submenus and settings.

Aptio Setup Utility – Copyright (C) 2017 American Megatrends, Inc.

<table><tr><td>Main</td><td>Advanced</td><td>Platform Configuration</td><td>Server Mgmt</td><td>Security</td><td>Boot</td><td>Save &amp; Exit</td></tr><tr><td colspan="5">BIOS Information</td><td rowspan="8" colspan="2">Set the Date. Use Tab to switch between Date elements.</td></tr><tr><td colspan="3">BIOS Vendor</td><td rowspan="2" colspan="2">American Megatrends 5.14</td></tr><tr><td colspan="3">Core Version</td></tr><tr><td colspan="3">Compliancy</td><td colspan="2">UEFI 2.7; PI 1.6</td></tr><tr><td colspan="3">BIOS Version</td><td colspan="2">MECS-7120 0.07.10</td></tr><tr><td colspan="3">Build Date</td><td colspan="2">07/29/2020</td></tr><tr><td colspan="3">MRC Version</td><td colspan="2">0584.D01</td></tr><tr><td colspan="3">SPS FW Version</td><td colspan="2">0A:4.1.4.296</td></tr><tr><td colspan="7">System Information</td></tr><tr><td colspan="3">Project Name</td><td colspan="2">MECS-7210</td><td></td><td></td></tr><tr><td colspan="3">CPU 0 Brand String</td><td colspan="2">Intel(R) Xeon(R) Gold 5218 CPU @2.30GHz</td><td></td><td></td></tr><tr><td colspan="3">CPU 1 Brand String</td><td colspan="2">Intel(R) Xeon(R) Gold 5218 CPU @2.30GHz</td><td></td><td></td></tr><tr><td colspan="3">CPU Frequency</td><td colspan="2">2300 MHz</td><td></td><td></td></tr><tr><td colspan="3">Total Memory</td><td colspan="2">16384 MB (DDR4)</td><td colspan="2">&lt;&lt;: Select Screen</td></tr><tr><td colspan="3">Memory Frequency</td><td colspan="2">2132 MHz</td><td colspan="2">^v: Select Item</td></tr><tr><td colspan="3">PCH SKU</td><td colspan="2">LBG QS/PRQ - 1G(S0)</td><td colspan="2">Enter: Select +/-: Change Opt.</td></tr><tr><td colspan="3">System Date</td><td colspan="2">[Thu 04/23/2018]</td><td colspan="2">F1: General Help</td></tr><tr><td colspan="3">System Time</td><td colspan="2">[16:28:59]</td><td colspan="2">F8: Previous Values</td></tr><tr><td rowspan="3" colspan="3">Access Level</td><td rowspan="3" colspan="2">Administrator</td><td colspan="2">F9: Optimized Default</td></tr><tr><td colspan="2">F10: Save &amp; Exit</td></tr><tr><td colspan="2">ESC: Exit</td></tr></table>

Version 2.19.1268. Copyright (C) 2017 American Megatrends, Inc.

# 5.2.1 BIOS Information

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>BIOS Vendor</td><td>Info-only.American Megatrends</td><td>Display vendor name of system BIOS.</td></tr><tr><td>Core Version</td><td>Info-onlyx.yy</td><td>Display core version of booting BIOS.</td></tr><tr><td>Compliancy</td><td>Info-onlyUEFI 2.7; PI 1.6</td><td>Display compliancy of booting BIOS</td></tr><tr><td>BIOS Version</td><td>Info-only.x.yy.zz</td><td>Display version of booting BIOS.</td></tr><tr><td>Build Date</td><td>Info-only.MM/DD/YYYY</td><td>It shows the date that BIOS was built.</td></tr><tr><td>MRC Version</td><td>Info-only.xxx.Ryy</td><td>Display the revision of MRC code which is implemented in BIOS.</td></tr><tr><td>SPS FW Version</td><td>Info-only.ww:x.y.z.aaa</td><td>Display the version of Intel manageability firmware which is implemented in BIOS.</td></tr></table>

# 5.2.2 System Information

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>Project Name</td><td>Info-only.MECS-7210</td><td>It shows project name.</td></tr><tr><td>CPU 0/1 Brand String</td><td>Info-only.Intel(R) Xeon ...</td><td>It shows what CPU is booting the system.</td></tr><tr><td>CPU Frequency</td><td>Info-only.XXXX MHz</td><td>It shows CPU&#x27;s frequency.</td></tr><tr><td>Total Memory</td><td>Info-only.XXXX MB (DDR4)</td><td>It shows total memory size used on the motherboard and memory type.</td></tr><tr><td>Memory Frequency</td><td>Info-only.XXXX MHz</td><td>It shows memory&#x27;s frequency.</td></tr><tr><td>PCH SKU</td><td>Info-only.LBG xxxxx</td><td>It shows what PCH SKU is designed on motherboard.</td></tr><tr><td>System Date</td><td>MM/DD/YYYY</td><td>For configuring/showing system date. When setting the Date, usekey to switch between Date elements.</td></tr><tr><td>System Time</td><td>HH:MM:SS</td><td>For configuring/showing system time. When setting the Time, usekey to switch between Time elements.</td></tr><tr><td>Access Level</td><td>Info-only.Administrator/User</td><td>It shows what access level is used to enter BIOS setup menu.</td></tr></table>

# 5.3 Advanced Menu

This menu contains the settings for most of the user interfaces in the system.

<table><tr><td>Main</td><td>Advanced</td><td>Platform Configuration</td><td>Server Mgmt</td><td>Security</td><td>Boot</td><td>Save &amp; Exit</td></tr><tr><td colspan="5">Above 4G Decoding [Disabled]</td><td colspan="2">Network Stack Settings</td></tr><tr><td colspan="5">&gt; Serial Port Console Redirection</td><td colspan="2"></td></tr><tr><td colspan="5">&gt; Network Stack Configuration</td><td colspan="2"></td></tr><tr><td colspan="5">&gt; iSCSI Configuration</td><td colspan="2"></td></tr><tr><td colspan="5">&gt; Intel(R) I210 Gigabit Network Connection - 00:E0:18:07:</td><td colspan="2"></td></tr><tr><td colspan="5">&gt; Intel(R) I210 Gigabit Network Connection - 00:E0:18:08</td><td colspan="2"></td></tr><tr><td colspan="5"></td><td colspan="2">&lt;&lt;: Select Screen^v: Select ItemEnter: Select+/-: Change Opt.F1: General HelpF8: Previous ValuesF9: Optimized DefaultF10: Save &amp; ExitESC: Exit</td></tr></table>

Version 2.19.1268. Copyright (C) 2017 American Megatrends, Inc.

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>Above 4G Decoding</td><td>DisabledEnabled</td><td>The definition of “Above 4G decoding” is to allow the user to enable or disable memory-mapped I/O for a 64-bit PCIe device to 4GB or greater address space</td></tr><tr><td>Serial Port Console Redirection</td><td>Sub-Menu</td><td>For configuring serial console.</td></tr><tr><td>Network Stack Configuration</td><td>Sub-Menu</td><td>For configuring Network Stack.</td></tr><tr><td>iSCSI Configuration</td><td>Sub-Menu</td><td>For iSCSI Configuration.</td></tr><tr><td>Intel(R) I210 Gigabit Network Connection - ...</td><td>Sub-Menu</td><td>Onboard Ethernet controller configuration loaded by EFI driver. The setup page designed by Intel and when running Ethernet EFI driver, this page will be shown. It is related to “Network” setting in Boot setup page.</td></tr></table>

# 5.3.1 Sub-Menu: Serial Port Console Redirection

Aptio Setup Utility – Copyright (C) 2017 American Megatrends, Inc.

Advanced

COM0

Console Redirection

[Enabled]

> Console Redirection Settings

Legacy Console Redirection

> Legacy Console Redirection Settings

Serial Port for Out‐of‐Band Management/

Windows Emergency Management Services (EMS)

Console Redirection

[Disabled]

> Console Redirection Settings

Console Redirection Enable or Disable.

>&lt;: Select Screen

^v: Select Item

Enter: Select

+/‐: Change Opt.

F1: General Help

F8: Previous Values

F9: Optimized Default

F10: Save & Exit

ESC: Exit

Version 2.19.1268. Copyright (C) 2017 American Megatrends, Inc.

&lt;table&gt;<tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>Console Redirection</td><td>EnabledDisabled</td><td>Enable or disable serial port console redirection function.</td></tr><tr><td>Console Redirection Settings</td><td>Sub-Menu</td><td>For configuring serial port settings when console redirection function is enabled.</td></tr><tr><td>Legacy ConsoleRedirection Settings</td><td>Sub-Menu</td><td>For configuring Legacy Console Redirection Settings</td></tr></table>

# 5.3.2 Sub-Menu: Console Redirection Settings

Aptio Setup Utility – Copyright (C) 2017 American Megatrends, Inc.

Advanced

<table><tr><td colspan="2">Console Redirection Settings</td><td>Emulation: ANSI:Extended ASCII char</td></tr><tr><td>Terminal Type</td><td>[VT100+]</td><td>set. VT100: ASCII char</td></tr><tr><td>Bits per second</td><td>[115200]</td><td>set. VT100+: Extends</td></tr><tr><td>Data Bits</td><td>[8]</td><td rowspan="2">VT100 to support color, function keys, etc.</td></tr><tr><td>Parity</td><td>[None]</td></tr><tr><td>Stop Bits</td><td>[1]</td><td rowspan="7">VT-UTF8: Uses UTF8 encoding to map Unicode chars onto 1 or more</td></tr><tr><td>Flow Control</td><td>[None]</td></tr><tr><td>VT-UTF8 combo key support</td><td>[80x24]</td></tr><tr><td>Recorder</td><td>[Enable]</td></tr><tr><td>Resolution 100x31</td><td>[Disabled]</td></tr><tr><td>Putty KeyPad</td><td>[Disabled]</td></tr><tr><td></td><td>[VT100]</td></tr><tr><td></td><td></td><td>&gt;&lt;: Select Screen^v: Select ItemEnter: Select+/-: Change Opt.F1: General HelpF8: Previous ValuesF9: Optimized DefaultF10: Save &amp; ExitESC: Exit</td></tr></table>

Version 2.19.1268. Copyright (C) 2017 American Megatrends, Inc.

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>Terminal Type</td><td>VT100VT100+VT-UTF8ANSI</td><td>Configure the type of console emulation.Emulation:ANSI: Extended ASCII char set.VT100: ASCII char set.VT100+: Extends VT100 to support color, function keys, etc.VT-UTF8: Uses UTF8 encoding to map Unicode chars onto 1 or more bytes.</td></tr><tr><td>Bits per second</td><td>9600192003840057600115200</td><td>Selects serial port transmission speed. The speed must be matched on the other side.Long or noisy lines may require lower speed.</td></tr><tr><td>Data Bits</td><td>78</td><td>Configure the number of data bits in each transmitted or received serial character for both serial ports.</td></tr><tr><td>Parity</td><td>NoneEvenOddMarkSpace</td><td>Configures if parity bit is generated (transmit data) or checked.A parity bit can be sent with the data bits todetect some transmission errors. Even: parity bit is 0 if the num of 1's in the data bits is even. Odd: parity bit is 0 if num of 1's in the data bits is odd. Mark: parity bit is always 1. Space: Parity bit is always 0. Mark and Space Parity do not allow for error detection. They can be used as an additional data bit.</td></tr><tr><td>Stop Bits</td><td>12</td><td>Configures the number of stop bits transmitted and received in each serial character for both serial ports. Stop bits indicate the end of a serial data packet. (A start bit indicates the beginning). The standard setting is 1 stop bit. Communication with slow devices may require more than 1 stop bit.</td></tr><tr><td>Flow Control</td><td>NoneHardware RTS/CTS</td><td>Configures flow control for console redirection. Hardware flow control uses RTC/CTS.</td></tr><tr><td>VT-UTF8 combo key Support</td><td>EnableDisable</td><td>Enable VT-UTF8 Combination Key Support for ANSI/VT100 terminals</td></tr><tr><td>Recorder Mode</td><td>EnableDisable</td><td>With this mode enabled only text will be sent. This is to capture Terminal data.</td></tr><tr><td>Resolution 100x31</td><td>EnableDisable</td><td>Enables or disables extended terminal resolution</td></tr><tr><td>Putty KeyPad</td><td>VT100</td><td>Select FunctionKey and KeyPad on Putty.</td></tr></table>

# 5.3.3 Sub-Menu: Legacy Console Configuration

Aptio Setup Utility – Copyright © 2020 American Megatrends, Inc.

Advanced

Legacy Console Redirection Settings

Redirection COM Port

Redirection

Redirection After POST

[COM0]

[80x24]

[Always Enable]

Select a COM port to display redirection of Legacy OS and Legacy OPROM Message

>&lt;: Select Screen

^v: Select Item

Enter: Select

+/‐: Change Opt.

F1: General Help

F8: Previous Values

F9: Optimized Default

F10: Save & Exit

ESC: Exit

Version 2.20.1275. Copyright © 2018 American Megatrends, Inc.

&lt;table&gt;<tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>Redirection COM Port</td><td>COM0</td><td>Select a COM port to display redirection of Legacy OS and Legacy OPROM Messages</td></tr><tr><td>Redirection</td><td>80X2480X25</td><td>On Legacy OS, the Number of Rows and Columns supported redirection</td></tr><tr><td>Redirection After POST</td><td>Always EnableBootLoader</td><td>When Bootloader is selected, then Legacy Console Redirection is disabled before booting to legacy OS. When Always Enable is selected, then Legacy Console Redirection is enabled for legacy OS. Default setting for this option is set to Always Enable.</td></tr></table>

# 5.3.4 Sub-Menu: Network Stack Configuration

Aptio Setup Utility – Copyright (C) 2017 American Megatrends, Inc.

Advanced

<table><tr><td rowspan="2" colspan="2">Network Stack Configuration</td><td>Enable/Disable UEFI</td></tr><tr><td>Network Stack</td></tr><tr><td>Network Stack</td><td>[Enabled]</td><td></td></tr><tr><td>Ipv4 PXE Support</td><td>[Enabled]</td><td></td></tr><tr><td>Ipv6 PXE Support</td><td>[Enabled]</td><td></td></tr><tr><td></td><td></td><td>&gt;&lt;: Select Screen^v: Select ItemEnter: Select+/-: Change Opt.F1: General HelpF8: Previous ValuesF9: Optimized DefaultF10: Save &amp; ExitESC: Exit</td></tr></table>

Version 2.19.1268. Copyright (C) 2017 American Megatrends, Inc.

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>Network Stack Configuration</td><td>Info-only</td><td></td></tr><tr><td>Network Stack</td><td>Disabled Enabled</td><td>To enable or disable network stack.</td></tr><tr><td>IPv4 PXE Support</td><td>Disabled Enabled</td><td>To enable or disable IPv4 PXE boot.</td></tr><tr><td>IPv6 PXE Support</td><td>Disabled Enabled</td><td>To enable or disable IPv6 PXE boot.</td></tr></table>

# 5.3.5 Sub-Menu: iSCSI Configuration

Aptio Setup Utility – Copyright © 2018 American Megatrends, Inc.

Advanced

iSCSI Initiator Name

> Add an Attempt

> Delete Attempts

> Change Attempt Order

The worldwide unique

Name of iSCSI

Initiator. Only IQN

Format is accepted.

Range is from 4 to 223

>&lt;: Select Screen

^v: Select Item

Enter: Select

+/‐: Change Opt.

F1: General Help

F8: Previous Values

F9: Optimized Default

F10: Save & Exit

ESC: Exit

Version 2.19.1268. Copyright © 2018 American Megatrends, Inc.

&lt;table&gt;<tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>iSCSI Initiator Name</td><td>Info-only</td><td></td></tr><tr><td>Add an Attempt</td><td>Sub-Menu</td><td>To Add an Attempt for MAC Selection if it’s available.</td></tr><tr><td>Delete Attempts</td><td>Sub-Menu</td><td>To Delete Attempts if it’s available.</td></tr><tr><td>Change Attempt Order</td><td>Sub-Menu</td><td>To Change Attempt Order if it’s available.</td></tr></table>

# 5.3.6 Sub-Menu: Intel(R) I210 Gigabit Network Connection

This setup page is shown when “Network” setting in Boot page is set to “UEFI”. When the BIOS boots the system, it will launch the onboard Ethernet I210 controller’s UEFI driver. The driver provides a setup page for configuring Ethernet parameters and shows information about Ethernet controller. When the Ethernet’s UEFI driver is not executed, this setup page will not be shown.

Aptio Setup Utility – Copyright (C) 2017 American Megatrends, Inc. Advanced

<table><tr><td colspan="2">&gt; NIC Configuration</td><td>Click to configure the network device port.</td></tr><tr><td>Blink LEDs</td><td>0</td><td></td></tr><tr><td>UEFI Driver</td><td>Intel(R) PRO/1000 6.7...</td><td></td></tr><tr><td>Adapter PBA</td><td>000300-000</td><td></td></tr><tr><td>Device Name</td><td>Intel(R) I210 Gigabit...</td><td></td></tr><tr><td>Chip Type</td><td>Intel i210</td><td></td></tr><tr><td>PCI Device ID</td><td>1533</td><td></td></tr><tr><td>PCI Address</td><td>03:00:00</td><td></td></tr><tr><td>Link Status</td><td>[Disconnected]</td><td></td></tr><tr><td>MAC Address</td><td>00:E0:18:07:18:00</td><td>&lt;&lt;: Select Screen</td></tr><tr><td>Virtual MAC Address</td><td>00:00:00:00:00:00</td><td>^v: Select ItemEnter: Select+/-: Change Opt.F1: General HelpF8: Previous ValuesF9: Optimized DefaultF10: Save &amp; ExitESC: Exit</td></tr></table>

Version 2.19.1268. Copyright (C) 2017 American Megatrends, Inc.

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>NIC Configuration</td><td>Sub-Menu</td><td>For configuring link speed and wake function.</td></tr></table>

# 5.3.7 Sub-Menu: NIC Configuration

Aptio Setup Utility – Copyright (C) 2017 American Megatrends, Inc.

Advanced

Link Speed Wake On LAN

[Auto Negotiated] [Enabled]

Specifies the port speed used for the selected boot protocol.

>&lt;: Select Screen

^v: Select Item

Enter: Select

+/‐: Change Opt.

F1: General Help

F8: Previous Values

F9: Optimized Default

F10: Save & Exit

ESC: Exit

Version 2.19.1268. Copyright (C) 2017 American Megatrends, Inc.

&lt;table&gt;<tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>Link Speed</td><td>Auto Negotiated10 Mbps Half10 Mbps Full100 Mbps Half100 Mbps Full</td><td>For setting link speed of Ethernet.</td></tr><tr><td>Wake On LAN</td><td>EnabledDisabled</td><td>For enabling/disabling wake on LAN function.</td></tr></table>

# 5.4 Platform Configuration Menu

Aptio Setup Utility – Copyright (C) 2017 American Megatrends, Inc.

<table><tr><td>Main</td><td>Advanced</td><td>Platform Configuration</td><td>Server Mgmt</td><td>Security</td><td>Boot</td><td>Save &amp; Exit</td></tr><tr><td colspan="5">&gt;CPU Configuration</td><td rowspan="11" colspan="2">CPU Configuration parameters</td></tr><tr><td colspan="5">&gt;Memory Configuration</td></tr><tr><td colspan="5">&gt;UPI Configuration</td></tr><tr><td colspan="5">&gt;Memory Error Enabling</td></tr><tr><td colspan="5">&gt;PCIe Error Enabling</td></tr><tr><td colspan="5">&gt;Socket0 Configuration</td></tr><tr><td colspan="5">&gt;Socket1 Configuration</td></tr><tr><td colspan="5">&gt;PCH SATA Configuration</td></tr><tr><td colspan="3">SR-IOV Support</td><td>[Enable]</td><td></td></tr><tr><td colspan="3">Intel© VT for Directed I/O (VT-d)</td><td>[Enable]</td><td></td></tr><tr><td colspan="3">Automatic Board Power Up</td><td>[On]</td><td></td></tr><tr><td colspan="5"></td><td colspan="2">&gt;&lt;: Select Screen^v: Select ItemEnter: Select+/-: Change Opt.F1: General HelpF8: Previous ValuesF9: Optimized DefaultF10: Save &amp; ExitESC: Exit</td></tr></table>

Version 2.19.1268. Copyright © 2017 American Megatrends, Inc.

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>CPU Configuration</td><td>Sub-Menu</td><td>For configuring CPU features/functions.</td></tr><tr><td>Memory Configuration</td><td>Sub-Menu</td><td>For configuring memory features and functions.</td></tr><tr><td>UPI Configuration</td><td>Sub-Menu</td><td>For configuring UPI features and functions.</td></tr><tr><td>Memory Error Enabling</td><td>Sub-Menu</td><td>For configuring memory error assertion settings.</td></tr><tr><td>PCIe Error Enabling</td><td>Sub-Menu</td><td>For configuring PCIe error assertion settings.</td></tr><tr><td>Socket0 Configuration</td><td>Sub-Menu</td><td>For configuring Socket0 features and functions.</td></tr><tr><td>Socket1 Configuration</td><td>Sub-Menu</td><td>For configuring Socket1 features and functions.</td></tr><tr><td>PCH SATA Configuration</td><td>Sub-Menu</td><td>For SATA operating mode setting.</td></tr><tr><td>SR-IOV Support</td><td>Disable Enable</td><td>For enabling/disabling SR-IOV Support.</td></tr><tr><td>Intel© VT for Directed I/O (VT-d)</td><td>Disable Enable</td><td>For enabling/disabling Intel VT-d function.</td></tr><tr><td>Automatic Board Power Up</td><td>On Off</td><td>Select 0m/Off for ACPI state after a G3</td></tr></table>

# 5.4.1 Sub-Menu: CPU Configuration

Aptio Setup Utility – Copyright (C) 2017 American Megatrends, Inc.

Platform

Configuration

CPU Configuration

Hyper‐Threading

Execute Disable Bit

VMX

Enable Intel(R) TXT

Numa

Hardware Prefetcher

SpeedStep (Pstates)

Turbo Mode

[Enable]

[Enable]

[Disable]

[Disable]

[Enable]

[Enable]

[Enable]

[Enable]

Enable/Disable Hyper‐Threading

>&lt;: Select Screen

^v: Select Item

Enter: Select

+/‐: Change Opt.

F1: General Help

F8: Previous Values

F9: Optimized Default

F10: Save & Exit

ESC: Exit

Version 2.19.1268. Copyright (C) 2017 American Megatrends, Inc.

&lt;table&gt;<tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>CPU Configuration</td><td>Info-only</td><td></td></tr><tr><td>Hyper-Threading</td><td>EnableDisable</td><td>To enable or disable hyper-threading function of CPU.</td></tr><tr><td>Execute Disable Bit</td><td>DisableEnable</td><td>Execute Disable Bit can help prevent certain classes of malicious buffer overflow attacks. OS and application installed must support this feature in order for it is enabled.</td></tr><tr><td>VMX</td><td>DisableEnable</td><td>To enable or disable Virtual-Machine Extensions of CPU.</td></tr><tr><td>Enable Intel(R) TXT</td><td>DisableEnable</td><td>Enable or disable Intel(R) TXT function.</td></tr><tr><td>Numa</td><td>DisableEnable</td><td>For enabling or disabling Numa function.</td></tr><tr><td>Hardware Prefetcher</td><td>DisableEnable</td><td>To enable or disable hardware prefetcher of CPU.</td></tr><tr><td>SpeedStep (P-states)</td><td>DisableEnable</td><td>To enable or disable Speedstep function of CPU.</td></tr><tr><td>Turbo Mode</td><td>DisableEnable</td><td>To enabled or disable Turbo Mode of CPU.</td></tr></table>

# 5.4.2 Sub-Menu: Memory Configuration

Aptio Setup Utility – Copyright © 2018 American Megatrends, Inc.

Platform

Configuration

Memory Configuration

> Memory Topology

Memory Frequency [Auto]

Channel Interleaving [Auto]

Rank Interleaving [Auto]

ADDDC Sparing [Disable]

Patrol Scrub [Enable]

Patrol Scrub Interval 24

Patrol Scrub Address [System Physical Addr]

Data Scrambling [Disable]

Volatile Memory Mode [1LM]

Displays memory

topology with Dimm

population information

>&lt;: Select Screen

^v: Select Item

Enter: Select

+/‐: Change Opt.

F1: General Help

F8: Previous Values

F9: Optimized Default

F10: Save & Exit

ESC: Exit

Version 2.19.1268. Copyright © 2018 American Megatrends, Inc.

&lt;table&gt;<tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>Memory Configuration</td><td>Info-only</td><td></td></tr><tr><td>Memory Topology</td><td>Sub-Menu</td><td>To display memory topology with DIMM's population information.</td></tr><tr><td>Memory Frequency</td><td>Auto1866213324002666</td><td>Use this item to set the maximum memory frequency for onboard memory modules.</td></tr><tr><td>Channel Interleaving</td><td>Auto1-way Interleave2-way Interleave3-way Interleave</td><td>Channel interleaving divide memory blocks and spread contiguous portions of data across interleaved channels. It increases potential read bandwidth as requests for data can be made to all interleaved channels in an overlapped manner. Enable channel interleaving is possible to enhance the performance.</td></tr><tr><td>Rank Interleaving</td><td>Auto</td><td>The interleaving is performed on rank</td></tr><tr><td></td><td>1-way Interleave2-way Interleave4-way Interleave8-way Interleave</td><td>to have different bandwidth.</td></tr><tr><td>ADDDC Sparing</td><td>DisableEnable</td><td>It is to enable/disable ADDDC sparing.NOTE: it can't be enabled when mirror mode is enabled or memory sparing is enabled.</td></tr><tr><td>Patrol Scrub</td><td>DisableEnable</td><td>When setting, Enable is set to this option, patrol scrub is initialized to read through all of memory in an interval hour period which is gotten from “Patrol Scrub interval” option. Patrol scrub will correct any correctable error correction code (ECC) errors it encounters by writing back the corrected data to memory.</td></tr><tr><td>Patrol Scrub Interval</td><td>24</td><td>Hour-based setting for the interval of patrol scrub.NOTE: this option will be hidden when “Patrol Scrub” is disabled.</td></tr><tr><td>Patrol Scrub Address</td><td>Reverse AddressSystem Physical Address</td><td>This is a feature for configuring the mode of Patrol scrub. When “System Physical Address” is set, patrol runs in system address generation mode. If it is set to “Reverse Address”, patrol will run in legacy mode.NOTE: this option will be hidden when “Patrol Scrub” is disabled.</td></tr><tr><td>Data Scrambling</td><td>DisableEnableAuto</td><td>Enable it to enhance system performance and data integrity.</td></tr><tr><td>Volatile Memory Mode</td><td>1LM2LMAuto</td><td>Configure “volatile memory mode” to one-level memory mode or two-level memory mode.</td></tr></table>

# 5.4.3 Sub-Menu: Memory Topology

Aptio Setup Utility – Copyright © 2018 American Megatrends, Inc.

Platform

Configuration

Socket0.ChD.Dimm0 :

2132MT/s SRx4 16GB RDIMM

Socket0.ChE.Dimm0 :

2132MT/s SRx4 16GB RDIMM

Socket0.ChF.Dimm0 :

2132MT/s SRx4 16GB RDIMM

>&lt;: Select Screen

^v: Select Item

Enter: Select

+/‐: Change Opt.

F1: General Help

F8: Previous Values

F9: Optimized Default

F10: Save & Exit

ESC: Exit

Version 2.19.1268. Copyright © 2018 American Megatrends, Inc.

&lt;table&gt;<tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>SocketX.ChY.DimmZ:</td><td>Info-only</td><td>The information shows only when memory is present in the DIMM slot.It is the information of DIMM slot&#x27;s location and X, Y and Z indicate which slot has memory plugged. $\mathbf{X} = 0/1 - CPU0/CPU1$  $\mathbf{Y} = Channel A/B/C/D/E/F of CPU0 or Channel G/H/J/K/L/M of CPU1$ Z will always be 0 because hardware design only supports one DIMM per channel.Regarding to the topology, please refer to section 2.2 – Memory initialization.</td></tr><tr><td>[Memory Frequency] [Rank number] [Memory size][Memory type]</td><td>Info-only</td><td>It is the information of memory frequency, type and size which varies by what memory is plugged.For example: 2132MT/s SRx4 16GB RDIMMIt means 16GB registered DIMM with 2133MT/s frequency is operating at 1 single rank x4 configuration.</td></tr></table>

# 5.4.4 Sub-Menu: UPI Configuration

Aptio Setup Utility – Copyright © 2018 American Megatrends, Inc.

Platform

Configuration

UPI Configuration

> UPI Status

Link Speed Mode [Fast]

Link Frequency Select [Auto]

KTI Prefetch [Enable]

Stale AtoS [Disable]

LLC dead line alloc [Enable]

UPI Status Help

>&lt;: Select Screen

^v: Select Item

Enter: Select

+/‐: Change Opt.

F1: General Help

F8: Previous Values

F9: Optimized Default

F10: Save & Exit

ESC: Exit

Version 2.19.1268. Copyright © 2018 American Megatrends, Inc.

&lt;table&gt;<tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>UPI Configuration</td><td>Info-only</td><td></td></tr><tr><td>UPI Status</td><td>Sub-Menu</td><td>To show the current UPI status includes number of CPU, IIO and UPI link speed and frequency.</td></tr><tr><td>Link Speed Mode</td><td>SlowFast</td><td>For configure UPI link speed.UPI speed mode should be ‘Slow’ when there only has one processor installed because UPI is not functional. Set ‘Slow’ for multi-processor only when it wants UPI to run at the boot speed of 50 MT/s.</td></tr><tr><td>Link Frequency Select</td><td>9.6GT/s10.4GT/sAutoUse Per Link Setting</td><td>For selecting UPI link frequency.When there is only one processor, setting of this item will not be functional and status of link frequency will be unknown or 1S configuration.</td></tr><tr><td>KTI Prefetch</td><td>DisableEnable</td><td>It is for enabling/disabling KTI prefetch function.</td></tr><tr><td>Stale AtoS</td><td>DisableEnableAuto</td><td>The in-memory directory has three states:invalid (I), snoopAll (A), and Shared (S).The snoopAll (A) means the data may exist in another socket or modified state.Shared (S) state means the data may be shared across one or more socket's caches. When reading memory and directory line is in the A state, we must snoop all the other sockets because another socket may have the line in modified state. If this is the case, the snoop will return the modified data.However, it may be the case that all snoops come back a miss if another socket read the line earlier and then dropped it from its cache without modifying it.Disable – allows processing memory directory states as described above.Enable – where a line in A state returns only snoop misses, the line will be transition to S state. Subsequent reads to the line will encounter it in S state and not have to snoop, saving latency and snoop bandwidth.</td></tr><tr><td>LLC dead line alloc</td><td>DisableEnableAuto</td><td>In CPU cache scheme, mid-level cache (MLC) evictions are filled into last-level case (LLC). When lines are evicted from MLC, core can flag them as “dead”. This means that lines are not likely to be read again. This option allows dropping dead line and never fills them into LLC if the option is disabled. When it is enabled, the LLC can opportunistically fill dead lines into LLC if space is available.</td></tr></table>

# 5.4.5 Sub-Menu: UPI Status

Aptio Setup Utility – Copyright © 2018 American Megatrends, Inc.

Platform

Configuration

UPI Status

<table><tr><td>Number of CPU</td><td>1</td></tr><tr><td>Number of IIO</td><td>1</td></tr><tr><td>UPI Link Speed</td><td>Slow or 1S</td></tr><tr><td>UPI Link Frequency</td><td>Unknown or 1S</td></tr></table>

>&lt;: Select Screen

^v: Select Item

Enter: Select

+/‐: Change Opt.

F1: General Help

F8: Previous Values

F9: Optimized Default

F10: Save & Exit

ESC: Exit

Version 2.19.1268. Copyright © 2018 American Megatrends, Inc.

&lt;table&gt;<tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>UPI Status</td><td>Info-only</td><td></td></tr><tr><td>Number of CPU</td><td>Info-only</td><td>Shows how many CPUs are using on system.</td></tr><tr><td>Number of IIO</td><td>Info-only</td><td>Shows how many IIOs are using on system.</td></tr><tr><td>UPI Link Speed</td><td>Info-only</td><td>Shows current UPI speed (fast/slow).</td></tr><tr><td>UPI Link Frequency</td><td>Info-only</td><td>Shows current UPI link frequency (9.6 GT/s or 10.4 GT/s).</td></tr></table>

# 5.4.6 Sub-Menu: Memory Error Enabling

Aptio Setup Utility – Copyright © 2018 American Megatrends, Inc.

Platform

Configuration

Memory Error Enabling

<table><tr><td>Memory Error</td><td>[Enable]</td></tr><tr><td>Mem Corrected Error</td><td>[Enable]</td></tr><tr><td>Error Threshold</td><td>3e8</td></tr><tr><td>Leaky bucket low bit</td><td>28</td></tr><tr><td>Leaky bucket high bit</td><td>29</td></tr></table>

Enable/Disable Memory Error

<table><tr><td>&gt;&lt;: Select Screen^v: Select ItemEnter: Select+/-: Change Opt.F1: General HelpF8: Previous ValuesF9: Optimized DefaultF10: Save &amp; ExitESC: Exit</td></tr></table>

Version 2.19.1268. Copyright © 2018 American Megatrends, Inc.

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>Memory Error Enabling</td><td>Info-only</td><td></td></tr><tr><td>Memory Error</td><td>DisableEnable</td><td>This is used to enable/disable memory error handling.</td></tr><tr><td>Mem Corrected Error</td><td>DisableEnable</td><td>This is used to enable/disable memory correctable error handling.</td></tr><tr><td>Error Threshold</td><td>1000</td><td>Rank sparing enables a failing rank to be replaced by an unused spare rank installed on the same DDR channel. The failure prediction is done viacorrected error thresholdand a leaky bucket, both of which are programmable to allow the platform to “judge” when the right time is to spare a failing rank.The value set in this item will be set to correctable error threshold used for error handling.</td></tr><tr><td>Leaky bucket low bit</td><td>40</td><td>Value range: 1 – 41It is to set low bit for the leaky bucket algorithm which is used to check the data transmissions between CPU sockets and the memory controller.</td></tr><tr><td>Leaky bucket high bit</td><td>41</td><td>Value range: 1 – 41It is to set high bit for the leaky bucket algorithm which is used to check the data transmissions between CPU sockets and the memory controller.</td></tr></table>

# 5.4.7 Sub-Menu: PCIe Error Enabling

Aptio Setup Utility – Copyright © 2018 American Megatrends, Inc.

Platform

Configuration

PCIe Error Enabling

<table><tr><td>Corrected Error</td><td>[Enable]</td></tr><tr><td>PCIE Corrected Error</td><td>[Enable]</td></tr><tr><td>Error Threshold Mask</td><td>3f</td></tr><tr><td>Error Threshold</td><td>1</td></tr><tr><td>Uncorrected Error</td><td>[Enable]</td></tr><tr><td>Fatal Error Enable</td><td>[Enable]</td></tr><tr><td>AER Corrected Error</td><td>[Enable]</td></tr><tr><td>AER Advisory Nonfatal</td><td>[Enable]</td></tr><tr><td>AER NonFatal Error</td><td>[Enable]</td></tr><tr><td>AER Fatal Error</td><td>[Enable]</td></tr><tr><td>SERR Propagation</td><td>[Enable]</td></tr><tr><td>PERR Propagation</td><td>[Enable]</td></tr><tr><td>Signal to OS on SERR</td><td>[Enable]</td></tr><tr><td>Signal to OS on PERR</td><td>[Enable]</td></tr></table>

Enable & escalate Correctable Errors to error pins.

>&lt;: Select Screen

^v: Select Item

Enter: Select

+/‐: Change Opt.

F1: General Help

F8: Previous Values

F9: Optimized Default

F10: Save & Exit

ESC: Exit

Version 2.19.1268. Copyright © 2018 American Megatrends, Inc.

&lt;table&gt;<tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>PCIe Error Enabling</td><td>Info-only</td><td></td></tr><tr><td>Corrected Error</td><td>DisableEnable</td><td>It is used to enable/disable PCIecorrectable error monitoring and handling.</td></tr><tr><td>PCIE Corrected Error</td><td>DisableEnable</td><td>It is used to enable/disable PCIecorrectable error counter.</td></tr><tr><td>Error Threshold Mask</td><td>0x3F</td><td>This is for setting what errors will be included in error count. (Bit 0 – Bit 5)Bit 0 – receiver errorBit 1 – Bad TLPBit 2 – Bad DLLPBit 3 – replay num rolloverBit 4 – Replay Timer TimeoutBit 5 – Advisory non-fatal</td></tr><tr><td>Error Threshold</td><td>1</td><td>It is for setting the threshold of PCIecorrectable error counter.</td></tr><tr><td>Uncorrected Error</td><td>Disable</td><td>It is for enabling/disabling the escalation</td></tr><tr><td></td><td>Enable</td><td>of uncorrectable event to error pins.</td></tr><tr><td>Fatal Error Enable</td><td>DisableEnable</td><td>It is for enabling/disable the escalation of PCIe fatal errors to error pins.</td></tr><tr><td>AER Corrected Error</td><td>DisableEnable</td><td>For enabling or disabling PCIE AER correctable error reporting.</td></tr><tr><td>AER Advisory Nonfatal</td><td>DisableEnable</td><td>For enabling or disabling PCIE AER Advisory Non-fatal error reporting.</td></tr><tr><td>AER NonFatal Error</td><td>DisableEnable</td><td>For enabling or disabling PCIE AER Non-fatal error reporting.</td></tr><tr><td>AER Fatal Error</td><td>DisableEnable</td><td>For enabling or disabling PCIE AER fatal error reporting.</td></tr><tr><td>SERR Propagation</td><td>DisableEnable</td><td>When PCI express root port detects an error, it will bring down the PCIe link associated with the affected root port within one cycle and then SMM handler restores the link. PCIe LER (live error recovery) prevents the transfer of associated corrupt data during process, trapping errors at a root port to prevent their propagation.This option is to enable/disable the prevention of SERR propagation.</td></tr><tr><td>PERR Propagation</td><td>DisableEnable</td><td>This option is to enable/disable the prevention of PERR propagation.</td></tr><tr><td>Signal to OS on SERR</td><td>DisableEnable</td><td>It is used for notifying OS on receiving SERR event.</td></tr><tr><td>Signal to OS on PERR</td><td>DisableEnable</td><td>It is used for notifying OS on receiving PERR event.</td></tr></table>

# 5.4.8 Sub-Menu: Socket 0/1 Configuration

Aptio Setup Utility – Copyright © 2018 American Megatrends, Inc.

Platform

Configuration

Memory Error Enabling

Daughter Board PCIe(IOU2 IIO PCIe BR3) [x16]

Enable/Disable Memory Error

>&lt;: Select Screen

^v: Select Item

Enter: Select

+/‐: Change Opt.

F1: General Help

F8: Previous Values

F9: Optimized Default

F10: Save & Exit

ESC: Exit

Version 2.19.1268. Copyright © 2018 American Megatrends, Inc.

&lt;table&gt;<tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>Daughter Board PCIe(IOU2 IIO PCIe BR3)</td><td>X16X8</td><td>Selects PCIe port Bifurcation for selected slot(s)</td></tr></table>

# 5.4.9 Sub-Menu: PCH SATA Configuration

Aptio Setup Utility – Copyright © 2018 American Megatrends, Inc.

Platform

Configuration

PCH SATA Configuration

<table><tr><td>SATA Controller</td><td>[Enable]</td></tr><tr><td>Configure SATA as</td><td>[AHCI]</td></tr><tr><td>SATA test mode</td><td>[Disable]</td></tr><tr><td>&gt;SATA Mode options</td><td></td></tr><tr><td>Support Aggressive Link Power Management</td><td>[Enable]</td></tr></table>

SATA Port 0

<table><tr><td>Port 0</td><td>[Enable]</td></tr><tr><td>Hot Plug</td><td>[Disable]</td></tr><tr><td>Configure as eSATA</td><td>[Disable]</td></tr><tr><td>Spin up Device</td><td>[Disable]</td></tr><tr><td>sSTS Device Type</td><td>[Hard Disk Drive]</td></tr><tr><td>SATA Topology</td><td>[Unknown]</td></tr></table>

CPU Configuration parameters

>&lt;: Select Screen

&lt;table&gt;<tr><td>^v: Select Item</td></tr><tr><td>Enter: Select</td></tr><tr><td>+/-: Change Opt.</td></tr><tr><td>F1: General Help</td></tr><tr><td>F8: Previous Values</td></tr><tr><td>F9: Optimized Default</td></tr><tr><td>F10: Save &amp; Exit</td></tr><tr><td>ESC: Exit</td></tr></table>

Version 2.19.1268. Copyright © 2018 American Megatrends, Inc.

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>SATA Controller</td><td>DisableEnable</td><td>For controlling SATA controller's enabling/disabling.</td></tr><tr><td>Configure SATA as</td><td>AHCIRAID</td><td>For SATA operating mode setting.</td></tr><tr><td>SATA test mode</td><td>DisableEnable</td><td>Enable/Disable SATA test mode</td></tr><tr><td>SATA Mode option</td><td>Sub-Menu</td><td>SATA mode related option</td></tr><tr><td>Support Aggressive Link Power Management</td><td>DisableEnable</td><td>Enables/Disables SALP</td></tr><tr><td>Port 0</td><td>DisableEnable</td><td>Enable or Disable SATA Port</td></tr><tr><td>Hot Plug</td><td>DisableEnable</td><td>Designates this port as Hot Pluggable</td></tr><tr><td>Configure as eSATA</td><td>DisableEnable</td><td>Configures port as External SATA (eSATA)</td></tr><tr><td>Spin up Device</td><td>DisableEnable</td><td>If enabled for any of ports Staggerred Spin Up will be performed and only the drives witch have this option enabled will spin up at boot. Otherwise all drives spin up at boot.</td></tr><tr><td>SATA Device Type</td><td>Hard Disk DriveSolid State Drive</td><td>Identify the SATA port is connected to Solid State Drive or Hard Disk Drive</td></tr><tr><td>SATA Topology</td><td>UnknownISATADirect ConnectFlexM2</td><td>Identify the Secondary SATA Topology if it is Default or ISATA or Flex or DirectConnect or M2</td></tr></table>

# 5.4.10 Sub-Menu: SATA Mode options

Aptio Setup Utility – Copyright © 2018 American Megatrends, Inc.

Platform

Configuration

<table><tr><td>SATA HDD Unlock</td><td>[Enable]</td><td rowspan="2">CPU Configuration parameters</td></tr><tr><td>SATA Led locate</td><td>[Rnable]</td></tr><tr><td></td><td></td><td>&gt;&lt;: Select Screen^v: Select ItemEnter: Select+/-: Change Opt.F1: General HelpF8: Previous ValuesF9: Optimized DefaultF10: Save &amp; ExitESC: Exit</td></tr></table>

Version 2.19.1268. Copyright © 2018 American Megatrends, Inc.

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>SATA HDD Unlock</td><td>DisableEnable</td><td>Enable: HDD password unlock is enabled in the OS</td></tr><tr><td>SATA Led locate</td><td>DisableEnable</td><td>If enabled LED/SGPIO hardware is attached</td></tr></table>

# 5.5 Server Mgmt Menu

Aptio Setup Utility – Copyright (C) 2017 American Megatrends, Inc.

<table><tr><td>Main</td><td>Advanced</td><td>Platform Configuration</td><td>Server Mgmt</td><td>Security</td><td>Boot</td><td>Save &amp; Exit</td></tr><tr><td colspan="3">BMC Self Test Status</td><td>PASSED</td><td></td><td rowspan="12" colspan="2">CPU Configuration parameters</td></tr><tr><td colspan="3">BMC Device Revision</td><td>32</td><td></td></tr><tr><td colspan="3">BMC Device Revision</td><td>1</td><td></td></tr><tr><td colspan="3">BMC Firmware Revision</td><td>1.06</td><td></td></tr><tr><td colspan="3">IPMI Version</td><td>2.0</td><td></td></tr><tr><td colspan="3">BMC Interface(s)</td><td>KCS, USB</td><td></td></tr><tr><td colspan="3">POST Watchdog Timer</td><td>[Disabled]</td><td></td></tr><tr><td colspan="3">POST Watchdog timeout</td><td>[6 minutes]</td><td></td></tr><tr><td colspan="3">POST Watchdog Timer Policy</td><td>[Reset]</td><td></td></tr><tr><td colspan="3">OS Watchdog Timer</td><td>[Disabled]</td><td></td></tr><tr><td colspan="3">OS Wtd Timer Timeout</td><td>[10 minutes]</td><td></td></tr><tr><td colspan="3">OS Wtd Timer Policy</td><td>[Reset]</td><td></td></tr><tr><td colspan="3">&gt; BMC network configuration</td><td></td><td></td><td rowspan="2" colspan="2">&gt;&lt;: Select Screen^v: Select ItemEnter: Select+/-: Change Opt.F1: General HelpF8: Previous ValuesF9: Optimized DefaultF10: Save &amp; ExitESC: Exit</td></tr><tr><td colspan="3">&gt; BMC User Setting</td><td></td><td></td></tr></table>

Version 2.19.1268. Copyright © 2017 American Megatrends, Inc.

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>BMC Self Test Status</td><td>Info-only</td><td>Shows BMC Self Test Status</td></tr><tr><td>BMC Device ID</td><td>Info-only</td><td>Shows BMC Device ID</td></tr><tr><td>BMC Device Revision</td><td>Info-only</td><td>Shows BMC Device Revision</td></tr><tr><td>BMC Firmware Revision</td><td>Info-only</td><td>Shows BMC Firmware Revision</td></tr><tr><td>IPMI Version</td><td>Info-only</td><td>Shows IPMI Version</td></tr><tr><td>BMC Interface(s)</td><td>Info-only</td><td>Shows BMC Interface(s)</td></tr><tr><td>POST Watchdog Timer</td><td>DisableEnable</td><td>Enable or Disable POST Watchdog Timer(FRB-2 timer)</td></tr><tr><td>POST Watchdog timeout</td><td>3 minutes4 minutes5 minutes6 minutes</td><td>Enter value Between 3 to 6 min for FRB-2 Timer Expiration value</td></tr><tr><td>POST Watchdog Timer Policy</td><td>Do Nothing Reset</td><td>Configure how the system should respond if the POST Watchdog Timer(FRB-2 Timer) expires. Not available if (FRB-2 Timer) is disabled.</td></tr><tr><td>OS Watchdog Timer</td><td>DisableEnable</td><td>If enabled, starts a BIOS timer which can only be shut off by Management Softwareafter the OS loads. Helps determine that the OS successfully loaded or follows the OS Boot Watchdog Timer policy.</td></tr><tr><td>OS Wtd Timer Timeout</td><td>5 minutes10 minutes15 minutes20 minutes</td><td>Configure the length of the OS Boot Watchdog Timer. Not available if OS Boot Watchdog Timer is disabled."</td></tr><tr><td>OS Wtd Timer Policy</td><td>Do Nothing Reset</td><td>Configure how the system should respond if the OS Boot Watchdog Timer expires. Not available if OS Boot Watchdog Timer is disabled</td></tr><tr><td>BMC network configuration</td><td>Sub-Menu</td><td>Configure BMC network parameters</td></tr><tr><td>BMC User Setting</td><td>Sub-Menu</td><td>Pressto Add, Delete and Set Privilege level for users</td></tr></table>

# 5.5.1 Sub-Menu: BMC network Configuration

Aptio Setup Utility – Copyright (C) 2017 American Megatrends, Inc.

Server

Mgmt

‐‐ BMC network configuration‐‐

Configure IPV4 support

LAN channel 1

Configuration Address source [Unspecified]

Current Configuration Address source DynamicAddressBmcDhcp

Station IP address 0.0.0.0

Subnet mask 0.0.0.0

Station MAC address 00‐30‐64‐10‐09‐50

Router IP address 0.0.0.0

Router MAC address 00‐00‐00‐00‐00‐00

\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*

Configure IPV6 support

\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*

Lan channel 1

IPV6 Support [Enabled]

Configuration Address source [Unspecified]

Current Configuration Address source DynamicAddressBmcDhcp

Station IP6 address

Prefix Length 0

IPV6 Router1 IP Address

IPV6 address status Active

IPV6 DHCP Algorithm DHCPv6

>&lt;: Select Screen

^v: Select Item

Enter: Select

+/‐: Change Opt.

F1: General Help

F8: Previous Values

F9: Optimized Default

F10: Save & Exit

ESC: Exit

&lt;table&gt;<tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>Configuration Address source</td><td>UnspecifiedStaticDynamicBmcDhcpDynamicBmcNonDhcp</td><td>Select to configure LAN channel parameters statically or dynamically(by BIOS or BMC). Unspecified option will not modify any BMC network parameters during BIOS phase</td></tr><tr><td>IPV6 Support</td><td>DisableEnable</td><td>Enable or Disable LAN1 IPV6 Support</td></tr></table>

# 5.5.2 Sub-Menu: BMC User Setting

Aptio Setup Utility – Copyright (C) 2017 American Megatrends, Inc.

Main Advanced Platform Server Security Boot Save & Exit Configuration Mgmt

>Add User

>Delete user

>Change User Setting

>&lt;: Select Screen

^v: Select Item

Enter: Select

+/‐: Change Opt.

F1: General Help

F8: Previous Values

F9: Optimized Default

F10: Save & Exit

ESC: Exit

Version 2.19.1268. Copyright © 2017 American Megatrends, Inc.

&lt;table&gt;<tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>Add User</td><td>Sub-Menu</td><td>Press &lt;Enter&gt; to Add a User</td></tr><tr><td>Delete user</td><td>Sub-Menu</td><td>Press &lt;Enter&gt; to Delete a User</td></tr><tr><td>Change User Setting</td><td>Sub-Menu</td><td>Press &lt;Enter&gt; to Change User Settings</td></tr></table>

# 5.5.3 Sub-Menu: Add User

Aptio Setup Utility – Copyright (C) 2017 American Megatrends, Inc.

Server

Mgmt

BMC Add User Dtails

User Name

USER Password

User Access

Channel No

User Privilege Limit

[Disable]

0

[Reserved]

>&lt;: Select Screen

^v: Select Item

Enter: Select

+/‐: Change Opt.

F1: General Help

F8: Previous Values

F9: Optimized Default

F10: Save & Exit

ESC: Exit

Version 2.19.1268. Copyright © 2017 American Megatrends, Inc.

&lt;table&gt;<tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>User Name</td><td>Enter to set user name</td><td>Enter BMC User Name</td></tr><tr><td>User Password</td><td>Enter to set password</td><td>Enter BMC User Password</td></tr><tr><td>User Access</td><td>DisableEnable</td><td>Enable/Disable the BMC User&#x27;s Access</td></tr><tr><td>Channel No</td><td>0~15</td><td>Enter BMC Channel Number</td></tr><tr><td>User Privilege Limit</td><td>ReservedCallbackUserOperatorAdministratorOEM ProprietaryNo Access</td><td>Enter BMC User Privilege Limit for Selected Channel</td></tr></table>

# 5.5.4 Sub-Menu: Delete User

Aptio Setup Utility – Copyright (C) 2017 American Megatrends, Inc.

Server

Mgmt

BMC Delete User Dtails

User Name

USER Password

>&lt;: Select Screen

^v: Select Item

Enter: Select

+/‐: Change Opt.

F1: General Help

F8: Previous Values

F9: Optimized Default

F10: Save & Exit

ESC: Exit

Version 2.19.1268. Copyright © 2017 American Megatrends, Inc.

&lt;table&gt;<tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>User Name</td><td>Enter to set user name</td><td>Enter BMC User Name</td></tr><tr><td>User Password</td><td>Enter to set password</td><td>Enter BMC User Password</td></tr></table>

# 5.5.5 Sub-Menu: Change User Setting

Aptio Setup Utility – Copyright (C) 2017 American Megatrends, Inc.

Server

Mgmt

BMC Change User Setting

User Name

USER Password

User Access [Disable]

Channel No 0

User Privilege Limit [Reserved]

>&lt;: Select Screen

^v: Select Item

Enter: Select

+/‐: Change Opt.

F1: General Help

F8: Previous Values

F9: Optimized Default

F10: Save & Exit

ESC: Exit

Version 2.19.1268. Copyright © 2017 American Megatrends, Inc.

&lt;table&gt;<tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>User Name</td><td>Enter to set user name</td><td>Enter BMC User Name</td></tr><tr><td>User Password</td><td>Enter to set password</td><td>Enter BMC User Password</td></tr><tr><td>User Access</td><td>DisableEnable</td><td>Enable/Disable the BMC User&#x27;s Access</td></tr><tr><td>Channel No</td><td>0~15</td><td>Enter BMC Channel Number</td></tr><tr><td>User Privilege Limit</td><td>ReservedCallbackUserOperatorAdministratorOEM ProprietaryNo Access</td><td>Enter BMC User Privilege Limit for Selected Channel</td></tr></table>

# 5.6 Security Menu

This menu contains the settings for system security.

Aptio Setup Utility – Copyright (C) 2017 American Megatrends, Inc.

<table><tr><td>Main</td><td>Advanced</td><td>Platform</td><td>Server Mgmt</td><td>Security</td><td>Boot</td><td>Save &amp; Exit</td></tr><tr><td colspan="7">Configuration</td></tr><tr><td colspan="5">Password Description</td><td></td><td></td></tr><tr><td colspan="5">If ONLY the Administrator&#x27;s password is set, then this only limits access to Setup and is Only asked for when entering Setup.</td><td></td><td></td></tr><tr><td colspan="5">If ONLY the User&#x27;s password is set, then this is a power on password and must be entered to boot or enter Setup. In Setup the user will have Administrator rights.</td><td></td><td></td></tr><tr><td colspan="5">The password length must be in the following range:</td><td></td><td></td></tr><tr><td colspan="3">Minimum length</td><td>3</td><td></td><td></td><td></td></tr><tr><td colspan="3">Maximum length</td><td>20</td><td></td><td></td><td></td></tr><tr><td colspan="5">Administrator Password</td><td rowspan="2" colspan="2">&lt;&lt;: Select Screen^v: Select ItemEnter: Select+/-: Change Opt.</td></tr><tr><td colspan="5">User Password</td></tr><tr><td colspan="5">&gt; Secure Boot</td><td rowspan="2" colspan="2">F1: General HelpF8: Previous ValuesF9: Optimized DefaultF10: Save &amp; ExitESC: Exit</td></tr><tr><td colspan="5">HDD Security Configuration</td></tr></table>

Version 2.19.1268. Copyright (C) 2017 American Megatrends, Inc.

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>Administrator Password</td><td>Enter to set password</td><td>Configure/Clear Administrator Password. When pressing enter, a menu will be popped up for creating new password. When password installed, press enter without inputting password, it will clear password.</td></tr><tr><td>User Password</td><td>Enter to set password</td><td>Configure/Clear User Password. When pressing enter, a menu will be popped up for creating new password. When password installed, press enter without inputting password, it will clear password.</td></tr><tr><td>Secure Boot</td><td>Sub-Menu</td><td>For secure boot configuration.</td></tr><tr><td>HDD Security Configuration</td><td>Sub-Menu</td><td>For HDD security, it will list all HDD detected on motherboard. Select the HDD and then press enter can figure/clear HDD password.</td></tr></table>

When selecting a HDD to configure passwords, BIOS will enter another setup page as below. The method of configuring HDD password is the same as that for BIOS passwords. Once a password is set, it will reflect the status on the screen, such as ‘HDD User Pwd Status’ changed to ‘INSTALLED’. When there is no HDD user password installed, you can change the master password without confirming the latest installed password. Once the HDD user password is installed, the HDD master password cannot be changed.

Aptio Setup Utility – Copyright (C) 2017 American Megatrends, Inc.

Security

<table><tr><td colspan="2">HDD Password Description</td><td rowspan="4"></td></tr><tr><td colspan="2">Allows Access to Set, Modify and Clear HardDisk User and Master Passwords.User Password need to be installed for Enabling Security. Master Password can be Modified only when successfully unlocked with Master Password in POST</td></tr><tr><td colspan="2">HDD PASSWORD CONFIGURATION</td></tr><tr><td colspan="2">P4:ST9160412AS</td></tr><tr><td>Security Supported</td><td>Yes</td><td rowspan="8">&gt;&lt;: Select Screen^v: Select ItemEnter: Select+/-: Change Opt.F1: General HelpF8: Previous ValuesF9: Optimized DefaultF10: Save &amp; ExitESC: Exit</td></tr><tr><td>Security Enabled</td><td>Yes</td></tr><tr><td>Security Locked</td><td>No</td></tr><tr><td>Security Frozen</td><td>No</td></tr><tr><td>HDD User Pwd Status</td><td>INSTALLED</td></tr><tr><td>HDD Master Pwd Status</td><td>INSTALLED</td></tr><tr><td colspan="2">Set User Password</td></tr><tr><td colspan="2">Set Master Password</td></tr></table>

Version 2.19.1268. Copyright (C) 2017 American Megatrends, Inc.

# 5.6.1 Sub-Menu: Secure Boot

Aptio Setup Utility – Copyright (C) 2017 American Megatrends, Inc.

Security

<table><tr><td colspan="2">Secure Boot</td><td>Secure Boot activated when</td></tr><tr><td>System Mode</td><td>User</td><td rowspan="2">Platform Key(PK) is enrolled, System mode is</td></tr><tr><td>Secure Boot</td><td>Not Active</td></tr><tr><td>Secure Boot Control</td><td>[Disabled]</td><td rowspan="2">User/Deployed, and CSM function is disabled</td></tr><tr><td>&gt;Key Management</td><td></td></tr><tr><td></td><td></td><td>&gt;&lt;: Select Screen^v: Select ItemEnter: Select+/-: Change Opt.F1: General HelpF8: Previous ValuesF9: Optimized DefaultF10: Save &amp; ExitESC: Exit</td></tr></table>

Version 2.19.1268. Copyright (C) 2017 American Megatrends, Inc.

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>Secure Boot</td><td>Info-only</td><td></td></tr><tr><td>System Mode</td><td>Info-only</td><td>Showing current system mode.</td></tr><tr><td>Secure Boot</td><td>Info-only</td><td>Showing current state of secure boot function.</td></tr><tr><td>Secure Boot Control</td><td>DisabledEnabled</td><td>Secure Boot can be enabled if:1. System running in User mode with enrolled Platform Key (PK)2. CSM function is disabled.</td></tr><tr><td>Key Management</td><td>Sub-Menu</td><td>For installing/appending/erasing secure boot databases and keys.</td></tr></table>

# 5.6.2 Sub-Menu: Key Management

Aptio Setup Utility – Copyright (C) 2017 American Megatrends, Inc.

Security

<table><tr><td colspan="4">Key Management</td><td>Enroll Factory Defaults or load certificates from a file:</td></tr><tr><td>Secure Boot variable</td><td>Size</td><td>Key#</td><td>Key Source</td><td>1.Public Key Certificate in:</td></tr><tr><td>&gt; Platform Key(PK)</td><td>0</td><td>0</td><td>No Key</td><td>a)EFI_SIGNATURE_LIST</td></tr><tr><td>&gt; Key Exchange Keys</td><td>0</td><td>0</td><td>No Key</td><td>b)EFI_CERT_X509 (DER encoded)</td></tr><tr><td>&gt; Authorized Signatures</td><td>0</td><td>0</td><td>No Key</td><td rowspan="2">c)EFI_CERT_RSA2048(bin)d)EFI_CERT_SHA256, 384, 5122.Authenticated UEFI Variable3.EFI PE/COFF Image</td></tr><tr><td>&gt; Forbidden Signatures</td><td>0</td><td>0</td><td>No Key</td></tr><tr><td></td><td></td><td></td><td></td><td>&gt;&lt;: Select Screen^v: Select ItemEnter: Select+/-: Change Opt.F1: General HelpF8: Previous ValuesF9: Optimized DefaultF10: Save &amp; ExitESC: Exit</td></tr></table>

Version 2.19.1268. Copyright (C) 2017 American Megatrends, Inc.

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>Platform Key(PK)</td><td>Enter</td><td>For installing/saving/erasing PK.</td></tr><tr><td>Key Exchange Keys</td><td>Enter</td><td>For installing/saving/appending/erasing KEK.</td></tr><tr><td>Authorized Signatures</td><td>Enter</td><td>For installing/saving/appending/erasing db.</td></tr><tr><td>Forbidden Signatures</td><td>Enter</td><td>For installing/saving/appending/erasing dbx.</td></tr></table>

# 5.7 Boot Menu

This menu contains the settings for bootable devices in the system.

<table><tr><td colspan="7">Aptio Setup Utility – Copyright (C) 2017 American Megatrends, Inc.</td></tr><tr><td>Main</td><td>Advanced</td><td>Platform Configuration</td><td>Server Mgmt</td><td>Security</td><td>Boot</td><td>Save &amp; Exit</td></tr><tr><td colspan="5">Boot Configuration</td><td colspan="2">Select boot mode LEGACY /UEF</td></tr><tr><td colspan="3">Quite Boot</td><td colspan="2">[Disable]</td><td colspan="2"></td></tr><tr><td colspan="3">CSM Support</td><td colspan="2">[Enabled]</td><td colspan="2"></td></tr><tr><td colspan="3">Network</td><td colspan="2">[UEFI]</td><td colspan="2"></td></tr><tr><td colspan="3">Storage</td><td colspan="2">[UEFI]</td><td colspan="2"></td></tr><tr><td colspan="3">Video</td><td colspan="2">[Legacy]</td><td colspan="2"></td></tr><tr><td colspan="3">Boot mode select</td><td colspan="2">[UEFI]</td><td colspan="2"></td></tr><tr><td colspan="3">Boot Configuration</td><td colspan="2"></td><td colspan="2"></td></tr><tr><td colspan="3">Boot Option #1</td><td colspan="2">[USB Hard Disk]</td><td colspan="2"></td></tr><tr><td colspan="3">Boot Option #2</td><td colspan="2">[USB CD/DVD]</td><td colspan="2"></td></tr><tr><td colspan="3">Boot Option #3</td><td colspan="2">[USB Key]</td><td colspan="2"></td></tr><tr><td colspan="3">Boot Option #4</td><td colspan="2">[USB Floppy]</td><td colspan="2">&gt;&lt;: Select Screen</td></tr><tr><td colspan="3">Boot Option #5</td><td colspan="2">[USB Lan]</td><td colspan="2">^v: Select Item</td></tr><tr><td colspan="3">Boot Option #6</td><td colspan="2">[Network]</td><td colspan="2">Enter: Select</td></tr><tr><td colspan="3">Boot Option #7</td><td colspan="2">[Hard Disk]</td><td colspan="2">+/-: Change Opt.</td></tr><tr><td colspan="3">Boot Option #8</td><td colspan="2">[CD/DVD]</td><td colspan="2">F1: General Help</td></tr><tr><td colspan="3">Boot Option #9</td><td colspan="2">[UEFI AP:UEFI: Built...]</td><td colspan="2">F8: Previous Values</td></tr><tr><td colspan="3">&gt;UEFI USB Key Drive BBS Priorities</td><td colspan="2"></td><td colspan="2">F9: Optimized Default</td></tr><tr><td colspan="3">&gt;UEFI Application Boot Priorities</td><td colspan="2"></td><td colspan="2">F10: Save &amp; Exit</td></tr><tr><td colspan="3"></td><td colspan="2"></td><td colspan="2">ESC: Exit</td></tr></table>

Version 2.19.1268. Copyright (C) 2017 American Megatrends, Inc.

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>Quite Boot</td><td>DisabledEnabled</td><td>Enables or Disables Quiet Boot option.</td></tr><tr><td>CSM Support</td><td>DisabledEnabled</td><td>Enable to support operating system that only support legacy mode.</td></tr><tr><td>Network</td><td>Do not launchUEFILegacy</td><td>Select the method of launch option ROM of network controller. UEFI will execute EFI driver and legacy will search option ROM of device to hook.</td></tr><tr><td>Storage</td><td>Do not launchUEFILegacy</td><td>Select the method of launch option ROM of storage controller. UEFI will execute EFI driver and legacy will search option ROM of device to hook.</td></tr><tr><td>Video</td><td>Do not launchUEFILegacy</td><td>Select the method of launch option ROM of graphic controller. UEFI will execute EFI driver and legacy will search option ROM of device to hook.</td></tr><tr><td>Boot mode select</td><td>LEGACYUEFI</td><td>Select boot mode, LEGACY/UEFI.</td></tr><tr><td>Boot Option #1 ~ #9</td><td>#1: USB Hard Disk#2: USB CD/DVD#3: USB Key#4: USB Floppy#5: USB Lan#6: Network#7: Hard Disk#8: CD/DVD#9: Built-in EFI Shell</td><td>For boot priority setting.</td></tr><tr><td>XXXX Drive BBS Priorities</td><td>Sub-Menu</td><td>When the bootable device is attached to system and found by BIOS, it will be listed at boot option#. If there are many devices with the same device type found, it can set priority among these devices through this sub-menu.</td></tr></table>

# 5.8 Save & Exit Menu

Aptio Setup Utility – Copyright (C) 2017 American Megatrends, Inc.

<table><tr><td>Main</td><td>Advanced</td><td>Platform Configuration</td><td>Server Mgmt</td><td>Security</td><td>Boot</td><td>Save &amp; Exit</td></tr><tr><td colspan="5">Save Changes and Exit</td><td rowspan="10" colspan="2">Exit system setup after saving the changes.</td></tr><tr><td colspan="5">Discard Changes and Exit</td></tr><tr><td colspan="5">Save Changes and Reset</td></tr><tr><td colspan="5">Discard Changes and Reset</td></tr><tr><td colspan="5">Save Options</td></tr><tr><td colspan="5">Save Changes</td></tr><tr><td colspan="5">Discard Changes</td></tr><tr><td colspan="5">Restore Defaults</td></tr><tr><td colspan="5">Save as User Defaults</td></tr><tr><td colspan="5">Restore User Defaults</td></tr><tr><td colspan="5">Boot Override</td><td colspan="2">&lt;&lt;: Select Screen</td></tr><tr><td colspan="5">Launch EFI Shell from filesystem device</td><td colspan="2">^v: Select ItemEnter: Select+/-: Change Opt.F1: General HelpF8: Previous ValuesF9: Optimized DefaultF10: Save &amp; ExitESC: Exit</td></tr></table>

Version 2.19.1268. Copyright (C) 2017 American Megatrends, Inc.

<table><tr><td>BIOS Item</td><td>Options</td><td>Description</td></tr><tr><td>Save Changes and Exit</td><td>Enter</td><td>Save changed settings and exit BIOS setup utility.</td></tr><tr><td>Discard Changes and Exit</td><td>Enter</td><td>Skip changed setting and exit BIOS setup utility.</td></tr><tr><td>Save Changes and Reset</td><td>Enter</td><td>Save all changed settings and let system do reset to boot system.</td></tr><tr><td>Discard Changes and Reset</td><td>Enter</td><td>Discard all changed settings and let system do reset to boot system.</td></tr><tr><td>Save Changes</td><td>Enter</td><td>Save all changed settings.</td></tr><tr><td>Discard Changes</td><td>Enter</td><td>Discard changes done so far to any of the setup options.</td></tr><tr><td>Restore Default</td><td>Enter</td><td>Load the default made when BIOS was built.</td></tr><tr><td>Save as User Default</td><td>Enter</td><td>Save all changed done so far as User Defaults.</td></tr><tr><td>Restore User Default</td><td>Enter</td><td>Load the default that user save as user defaults.</td></tr><tr><td>Boot Override</td><td>Info-only</td><td></td></tr></table>

# Important Safety Instructions

For user safety, please read and follow all instructions, WARNINGS, CAUTIONS, and NOTES marked in this manual and on the associated equipment before handling/operating the equipment.

1. Read these safety instructions carefully.
2. Keep this user’s manual for future reference.
3. Read the specifications section of this manual for detailed information on the operating environment of this equipment.
4. The equipment can be operated at an ambient temperature of $ 4 0 ^ { \circ } \mathsf { C }$
5. When installing/mounting or uninstalling/removing equipment; or when removal of the chassis lid required for user servicing (Section 3.1-3.5):
• Turn off power and unplug any power cords/cables, and
• Reinstall the chassis lid before restoring power.

![The image displays a standard warning sign consisting of a dark red triangle with a white exclamation point in the center. Below the triangle, the text 'WARNING:' is printed in black, uppercase letters.](.mecs-7210-50m-00013-1020-12/9ded40f00b0aa67e8437b82bdeb57bd617e0f6f722fe851a4b3c55f306a18e9e.jpg)

Hazardous moving parts. Keep body parts out of the motion path.

![A black outline of a triangle enclosing a symbol of a four-bladed fan or propeller.](.mecs-7210-50m-00013-1020-12/bad36395f62e26d9b9be7fa1f6014230bb1f9d67fa002087bb4803bfc2051f4c.jpg)

6. To avoid electrical shock and/or damage to equipment:

• Keep equipment away from water or liquid sources;
• Keep equipment away from high heat or high humidity;
• Keep equipment properly ventilated (do not block or cover ventilation openings);
• Make sure to use recommended voltage and power source settings;
Always install and operate equipment near an easily accessible electrical socketoutlet;
• Secure the power cord (do not place any object on/over the power cord);
Only install/attach and operate equipment on stable surfaces and/or recommended mountings;
If the equipment will not be used for long periods of time, turn off and unplug the equipment from its power source.
• The power cord must be connected to a socket or outlet with a ground connection.

7. Never attempt to fix the equipment. Equipment should only be serviced by qualified personnel.

8. An RTC battery may be provided for uninterrupted, backup or emergency power.

![The image shows a yellow triangular warning sign with a black border containing a black exclamation point. Below the triangle, the text 'CAUTION:' is printed in black capital letters.](.mecs-7210-50m-00013-1020-12/dac333b41fa6fa1ce2ba9ec08328ea2518349d1e8f22be1d7ed41356dbbafc13.jpg)

Risk of explosion if battery is replaced with one of an incorrect type. Please dispose of used batteries appropriately.

9. This equipment is not suitable for use in locations where children are likely to be present.

10. Equipment must be serviced by authorized technicians when:

The power cord or plug is damaged;
Liquid has penetrated the equipment;
• It has been exposed to high humidity/moisture;
• It is not functioning or does not function according to the user’s manual;
• It has been dropped and/or damaged; and/or,
It has an obvious sign of breakage.

11. Please pay strict attention to all warnings and advisories appearing on the device, to avoid injury or damage.
12. The equipment may have more than one power supply input. To reduce the risk of electrical shock, trained personnel should disconnect all power supply inputs before servicing.

![The image displays a standard safety warning sign. It features a yellow triangle with a black border containing a large black exclamation point in the center. Below the triangle, the word 'CAUTION:' is printed in black capital letters.](.mecs-7210-50m-00013-1020-12/7fc156c4314c9da3ae15560ae6e1e8ef8381e883b33e4044e91e80496c23cf4d.jpg)

Shock hazard! Disconnect all power supply inputs before servicing.

![The image displays a standard yellow triangular warning sign with a black border. In the center, there is a black lightning bolt symbol, indicating an electrical hazard or high voltage.](.mecs-7210-50m-00013-1020-12/e026ad6dc6c07fa013790613720261c47fff345904b6303abca4fd3b92f557bb.jpg)
Shock hazard! Risque d'électrocution!

![The image is a black and white line drawing depicting a schematic diagram. On the far left, there are three vertical parallel lines. To their right is a large triangle pointing to the right, containing three short vertical dashes on its left side. Above the triangle, there are three diagonal lines slanting upwards to the right. At the top right, a horizontal arrow points to the right. There is no text in the image.](.mecs-7210-50m-00013-1020-12/3c6b726a081330ea75e5d4e3efe4598c7a27a410c32d716ccfa03ada890b0e0d.jpg)
Multiple power sources Sources d'alimentation multiples

13. It is recommended that equipment be installed only in a server room or computer room where access is:

Restricted to qualified service personnel or users familiar with restrictions applied to the location, reasons therefor, and any precautions required;
Only afforded by the use of a tool or lock and key, or other means of security, and is controlled by the authority responsible for the location.

14. Suitable for installation in Information Technology Rooms in accordance with Article 645 of the National Electrical Code and NFPA 75.

# Consignes de Sécurité Importantes

Pour assurer la sécurité de l’utilisateur, veuillez lire et suivre toutes les directives, ainsi que les AVERTISSEMENTS, MISES EN GARDE et REMARQUES de ce manuel et indiqués sur l’équipement associé avant de manipuler ou utiliser l’équipement.

1. Veuillez lire attentivement ces instructions de sécurité avec soin.
2. Veuillez conserver ce manuel pour référence future.
3. Veuillez lire la section des spécifications de ce manuel pour avoir des informations détaillées sur l’environnement d’exploitation de cet équipement.
4. L’équipement peut être utilisé à une température ambiante de 40 °C.
5. Lors de l’installation ou du montage et de la désinstallation ou de la dépose de l’équipement; ou lors de la dépose du couvercle du châssis pour procéder à l’entretien par l’utilisateur (Sections 3.1-3.5):

• Coupez l’alimentation et débranchez les cordons et les câbles d’alimentation, et
Reposez le couvercle du châssis avant de remettre l’alimentation.

![The image features a red equilateral triangle containing a white exclamation point in its center. Below the triangle, the word 'WARNING' is written in black capital letters.](.mecs-7210-50m-00013-1020-12/4f41d06d042cede34202c9459563c5e836f178dc55f42b71a3b14578c6a287b5.jpg)
AVERTISSEMENT

Pièces mobiles dangereuses. Gardez les parties du corps hors de la trajectoire.

![The image displays a simple black line drawing on a white background. It features a large triangle pointing upwards. Centered inside the triangle is a symbol resembling a four-bladed fan or propeller, with a central hub and four curved blades radiating outward. There is no text in the image.](.mecs-7210-50m-00013-1020-12/9e175ae4cead6e2ce76ffab8c81e63d1332f2b0f4dcde5da615a34ec18233d6a.jpg)

6. Pour éviter un risque d’électrocution et pour éviter d’endommager l’équipement :

• Éloignez l’équipement de l’eau et de toute source liquide;
• Éloignez l’équipement de toute source de chaleur ou d’humidité élevée;
Gardez l’équipement correctement ventilé (ne pas bloquer ou couvrir les ouvertures de ventilation);
Veillez à utiliser la tension recommandée et les réglages adéquats pour la source d’alimentation;
Veuillez toujours installer et exploiter l’équipement à proximité d’une prise de courant facilement accessible;
Assurez-vous que le cordon d’alimentation est acheminé de manière sécuritaire (ne déposez aucun objet dessus);
Installez, fixez et utilisez l’équipement sur des surfaces stables ou sur les fixations recommandées uniquement;
Si l’équipement n’est pas utilisé pendant une longue période, éteignez-le et débranchez-le de sa source d’alimentation.
• Le cordon d'alimentation doit être connecté à une prise ou à une prise de courant avec mise à la terre.

7. N’essayez jamais de réparer l’équipement. L’équipement ne doit être réparé que par du personnel qualifié.

8. Une pile au lithium peut être installée pour assurer l’alimentation de secours ou d’urgence en continu.

![The image displays a standard warning sign featuring a yellow triangle with a black border. Inside the triangle is a black exclamation point. Below the triangle, the word 'CAUTION:' is printed in black, uppercase letters.](.mecs-7210-50m-00013-1020-12/6416b2d144c5c64ad67abc2fd9bf33468f7e39c4153a6c10df492aa83ac8510e.jpg)
mise en garde

Risque d'explosion si la batterie est remplacée par une batterie d'un type incorrect. Veuillez éliminer les piles usagées de manière appropriée.

9. Cet équipement ne convient pas à une utilisation dans des lieux pouvant accueillir des enfants.
10. L’équipement doit être entretenu par des techniciens agréés lorsque :

le cordon d’alimentation est endommagé ou lorsque la fiche électrique est endommagée;
du liquide a pénétré à l’intérieur de l’équipement;
l’équipement a été exposé à un taux d’humidité élevé;
l’équipement ne fonctionne pas ou ne fonctionne pas conformément au manuel de l’utilisateur;
• l’équipement est tombé ou lorsqu’il a été endommagé;
• l’équipement présente un signe évident de défaillance.

11. Veuillez porter une attention rigoureuse à tous les avertissements et à tous les avis figurant sur l’appareil, pour éviter des blessures ou des dommages.
12. L’équipement peut avoir plus d’une entrée d’alimentation. Pour réduire le risque d’électrocution, le personnel qualifié devrait déconnecter toutes les entrées d’alimentation avant de procéder à l’entretien.

![The image displays a yellow triangular warning sign with a black border. Inside the triangle is a large black exclamation point. Below the triangle, the word 'CAUTION' is printed in black capital letters.](.mecs-7210-50m-00013-1020-12/8e352b359d5817a65198fab9a110efd9b2e3f35e4fdbb79552a920f54ee4acc7.jpg)
mise en garde

Risque d'électrocution! Débranchez toutes les entrées d'alimentation avant de procéder à l'entretien.

![The image shows a yellow triangular warning sign with a thick black border. Inside the triangle is a black lightning bolt symbol, indicating an electrical hazard. There is no text present in the image.](.mecs-7210-50m-00013-1020-12/f449c986eea78f6e81e3505df2892742ee75fb775767b5cbaa87fe440a4c3897.jpg)
Shock hazard! Risque d'électrocution!

![The image displays a schematic diagram featuring black line drawings on a white background.\n\n*   **Far Left:** There are two vertical parallel lines. To their right, three short horizontal lines are stacked vertically.\n*   **Center:** A large triangle points to the right (resembling an operational amplifier symbol). Inside the triangle, near the top edge, are two short horizontal lines. To the left of the triangle's base are two short vertical lines. To the right of the triangle's tip are three short horizontal lines.\n*   **Top:** An arrow points to the right. Below the arrow shaft, there are four horizontal lines stacked vertically.](.mecs-7210-50m-00013-1020-12/990173bcfb91a91105b1e7789a9da313e846081371c121d60caaa138b2a100d3.jpg)
Multiple power sources Sources d'alimentation multiples

13. Il est recommandé que l'équipement soit installé que dans une salle de serveur ou de la salle informatique où:

L'accès est limité au personnel de maintenance qualifié ou utilisateurs familiers avec les restrictions appliquées à l'emplacement, motifs, et tout les précautions nécessaires, et;
• L'accès est uniquement assurée par l'utilisation d'un outil ou clé, ou d'autres moyens de sécurité, et est contrôlé par l'autorité responsable de l'emplacement.

14. Peut être installé dans des salles de matériel de traitement de l’information conformément à l’article 645 du National Electrical Code et à la NFPA 75.

# Getting Service

Ask an Expert: http://askanexpert.adlinktech.com

# ADLINK Technology, Inc.

Address: 9F, No.166 Jian Yi Road, Zhonghe District

New Taipei City 235, Taiwan

新北市中和區建一路 166 號 9 樓

Tel: +886-2-8226-5877

Fax: +886-2-8226-5717

Email: service@adlinktech.com

# Ampro ADLINK Technology, Inc.

Address: 5215 Hellyer Avenue, #110, San Jose, CA 95138, USA

Tel: +1-408-360-0200

Toll Free: +1-800-966-5200 (USA only)

Fax: +1-408-360-0222

Email: info@adlinktech.com

# ADLINK Technology (China) Co., Ltd.

Address: 上海市浦东新区张江高科技园区芳春路 300 号 (201203)

300 Fang Chun Rd., Zhangjiang Hi-Tech Park, Pudong New Area

Shanghai, 201203 China

Tel: +86-21-5132-8988

Fax: +86-21-5132-3588

Email: market@adlinktech.com

# ADLINK Technology GmbH

Address: Hans-Thoma-Strasse 11, D-68163, Mannheim, Germany

Tel: +49-621-43214-0

Fax: +49-621 43214-30

Email: emea@adlinktech.com

Please visit the Contact page at www.adlinktech.com for information on how to contact the ADLINK regional office nearest you.
[🔗 Link to the original document](.mecs-7210-50m-00013-1020-12/mecs-7210-50m-00013-1020-12.pdf)