# CEI-4x10G-SFP +

User’s Guide

![Close-up of a green printed circuit board with integrated circuits and capacitors, no readable text or symbols present.](.prod-spec-cei-4x10g-sfp-card-79024-user-manual/4f0b0dcbffffef645ea9237770512775d89527b7dd0e65e862c39c76d2c59bbf.jpg)

Revision History

<table><tr><td>Revision</td><td>Description</td><td>Date</td><td>Author</td></tr><tr><td>1.0</td><td>CEI-4x10G-SFP+ Card</td><td>2023/6/29</td><td>Lauryn Hsu</td></tr></table>

# Preface

# Disclaimer

Information in this document is provided in connection with ADLINK products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in ADLINK´s Terms and Conditions of Sale for such products, ADLINK assumes no liability whatsoever, and ADLINK disclaims any express or implied warranty, relating to sale and/or use of ADLINK products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property right. If you intend to use ADLINK products in or as medical devices, you are solely responsible for all required regulatory compliance, including, without limitation, Title 21 of the CFR (US), Directive 2007/47/EC (EU), and ISO 13485 & 14971, if any. ADLINK may make changes to specifications and product descriptions at any time, without notice.

# Environmental Responsibility

ADLINK is committed to fulfil its social responsibility to global environmental preservation through compliance with the European Union's Restriction of Hazardous Substances (RoHS) directive and Waste Electrical and Electronic Equipment (WEEE) directive. Environmental protection is a top priority for ADLINK. We have enforced measures to ensure that our products, manufacturing processes, components, and raw materials have as little impact on the environment as possible. When products are at their end of life, our customers are encouraged to dispose of them in accordance with the product disposal and/or recovery programs prescribed by their nation or company.

![The image displays a standard yellow warning sign featuring a thick black border and a central black exclamation mark.](.prod-spec-cei-4x10g-sfp-card-79024-user-manual/cadd98e080ac31d0e1094c45bf281355feb9a95da6160ce6c09642863ad716d2.jpg)

California Proposition 65 Warning: This product can expose you to chemicals including acrylamide, arsenic, benzene, cadmium, Tris(1,3- dichloro-2-propyl)phosphate (TDCPP), 1,4-Dioxane, formaldehyde, lead, DEHP, styrene, DINP, BBP, PVC, and vinyl materials, which are known to the State of California to cause cancer, and acrylamide, benzene, cadmium, lead, mercury, phthalates, toluene, DEHP, DIDP, DnHP, DBP, BBP, PVC, and vinyl materials, which are known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.

![The image displays a black outline drawing of a wheeled trash bin with a lid. A large black 'X' is superimposed over the bin, indicating it should not be disposed of in that manner. At the bottom of the image, there is a solid black rectangular shape. No other text or symbols are visible.](.prod-spec-cei-4x10g-sfp-card-79024-user-manual/592f21c4ed54767105db4c337dcc708c4a770bc85af21876327f8d3c750a38fc.jpg)

# Trademarks

Product names mentioned herein are used for identification purposes only and may be trademarks / registered trademarks of respective companies.

# Copyright © 2021 ADLINK Technology Incorporated

This document contains proprietary information protected by copyright. All rights are reserved. No part of this manual may be reproduced by any mechanical, electronic, or other means in any form without prior written permission of the manufacturer.

# Safety Instructions

For user safety, please read and follow all Instructions, WARNINGs, CAUTIONs, and NOTEs marked in this manual and on the associated equipment before handling/operating the equipment.

Read these safety instructions carefully.

Keep this manual for future reference.
• Read the specifications section of this manual for detailed information on the operating environment of this equipment.
• Turn off power and unplug any power cords/cables when installing/mounting or un-installing/removing equipment.
• To avoid electrical shock and/or damage to equipment:
• Keep equipment away from water or liquid sources;
• Keep equipment away from high heat or high humidity;
• Keep equipment properly ventilated (do not block or cover ventilation openings);
• Make sure to use recommended voltage and power source settings;
• Always install and operate equipment near an easily accessible electrical socket outlet;
• Secure the power cord (do not place any object on/over the power cord);
• Only install/attach and operate equipment on stable surfaces and/or recommended mountings;
• If the equipment will not be used for long periods of time, turn off the power source and unplug the equipment.

# Conventions

The following conventions may be used throughout this manual, denoting special levels of information

![The image displays a red icon resembling a document or memo pad. It features a thick red outline shaped like a piece of paper with a folded bottom-right corner. Inside the white interior, there are two horizontal red lines centered one above the other.](.prod-spec-cei-4x10g-sfp-card-79024-user-manual/1eee979589f7eaa8ad4abc4ff38adda6a633fee01d41d271d0ed7589e9cedae0.jpg)

Note: This information adds clarity or specifics to text and illustrations.

![The image displays a yellow triangular warning symbol with rounded corners. Inside the triangle is a black exclamation point centered vertically. The background is white.](.prod-spec-cei-4x10g-sfp-card-79024-user-manual/6c14cdf5147b68b028e7357addc2b8ea009ffee97b41279491c547dba19c3e02.jpg)

Caution: This information indicates the possibility of minor physical injury, component damage, data loss, and/or program corruption.

![The image features a red warning symbol consisting of a triangle with rounded corners. Inside the red triangle is a white exclamation point centered vertically and horizontally. The background surrounding the symbol is white.](.prod-spec-cei-4x10g-sfp-card-79024-user-manual/29c03168108f60512e84103fb120e37d0a0303df40407083fee3f7e57ae3e8a5.jpg)

Warning: This information warns of possible serious physical injury, component damage, data loss, and/or program corruption.

# Getting Service

Ask an Expert: http://askanexpert.adlinktech.com

# ADLINK Technology, Inc.

No. 66, Huaya 1st Rd., Guishan District, Taoyuan City 333411, Taiwan

Tel: +886-3-216-5088

Fax: +886-3-328-5706

Email: service@adlinktech.com

# Ampro ADLINK Technology, Inc.

6450 Via Del Oro, San Jose, CA 95119-1208, USA

Tel: +1-408-360-0200

Toll Free: +1-800-966-5200 (USA only)

Fax: +1-408-600-1189

Email: info@adlinktech.com

# ADLINK Technology (China) Co., Ltd.

300 Fang Chun Rd., Zhangjiang Hi-Tech Park, Pudong New Area, Shanghai, 201203, China

Tel: +86-21-5132-8988

Fax: +86-21-5132-3588

Email: market@adlinktech.com

# ADLINK Technology GmbH

Hans-Thoma-Strasse 11, D-68163 Mannheim, Germany

Tel: +49-621-43214-0

Fax: +49-621 43214-30

Email: emea@adlinktech.com

Please visit the Contact page at www.adlinktech.com for information on how to contact the ADLINK regional office nearest you.

# Table of Contents

2.1. Interface... ... 10
2.2. 10GbE PHY .. . 10
2.3. Dimensions.. .. 11
2.4. Operating Temperature.. .. 11
2.5. Specification Compliance.. . 11
2.6. IO Expander & EEPROM .. ... 12
4.1. Input Interface Definitions .. ... 14
5.1. Connector and LED Locations. ... 16
5.2. LED Indicators ... ... 17
5.3. 10GbE Adaptor Card Installation . ... 18

# List of Figures

Figure 1 – CEI-4x10G-SFP+ function diagram . .. 13

Figure 3 – Module feature locations ........ ... 16

Figure 5 – CEI-4x10G-SFP+ mechanical dimensions ......... ... 19

# 1. Introduction

The ADLINK CEI-4x10G-SFP+ Card is a 10GbE copper network adapter card that delivers fast 10Gbps network access. It converts up to four 10GBASE-KR interfaces & related CEI style sideband signals to four 10G Ethernet ports interfaces at SFP+ connectors, through Intel C827 PHY and multiple IO expanders.

The CEI-4x10G-SFP+ Card can only be used with ADLINK’s COM-HPC-sIDH module (PICMG COM-HPC Rev 1.0 Server Type compliant)

By using the CEI-4x10G-SFP+ Card with an COM-HPC Server reference carrier board and COM-HPC-sIDH module, customers can quickly emulate the functionality of their end product for software development and hardware verification. Applications include entry level switch, cloud storage platforms and communications servers.

# 2. Specifications

# 2.1. Interface

# Input

Up to four 10GBASE-KR & related CEI style sideband signals from a dedicated COM-HPC Server Type through 64-pin OCP Mezzanine card connector

# Output

Up to four 10G Ethernet ports at four SFP+ connectors

# 2.2. 10GbE PHY

# PHY

Intel C827 Optical Fiber

Converts 10GBASE-KR and sidebands to 10GSFP+

# PHY FW on SPI ROM

Dedicated ROM for PHY firmware store

# ID EEPROM (AT24C32E EEPROM)

I2C based device, identify the capabilities of the attached site. This allows the firmware to configure the attached PHY(s) and necessary I/O modes.

![EEPROM\n282:03:\n4x10G-C827-OCP-SFP\n51-79024-0A10\nS/N\nM40BPEAAD6\nLF\n000E\n23\n100\n16A\n23\n100\n16A\n2R2\n219\n2LB\nADLINK\n2R2\n219\n2LB\nH6\nH5\nH4\nH3\nH2\nH1\nCE\nADLINK\nEEPROM](.prod-spec-cei-4x10g-sfp-card-79024-user-manual/5abdbfa5ed9d31239be3b51c20989db191a817c7354725dfd803b0d1eaa85d76.jpg)

# 2.3. Dimensions

110 mm x 68 mm (PCB only, connector NOT included)

# 2.4. Operating Temperature

0°C to +55°C

# 2.5. Specification Compliance

PICMG COM-HPC Rev 1.0

# 2.6. IO Expander & EEPROM

Additional expander and EEPROM not mention above are described as below:

# PCA9575 IO Expander

I2C based device, deserialize for low speed sideband IO, including interrupt, reset and so on

# PCA9685 LED Ctrl

I2C based device, handle the LED indication

# 3. Block Diagram

4x10G-C827-0CP-SFP+reV.A1 51-79024-0A10-A0

# Block Diagram

![**Blocks:**\n*   **Left:** 'OCP type C connector'\n*   **Center Top:** 'PHY' and 'C827'\n*   **Center Bottom:** 'I2C MUX' and 'PCA9546AD'\n*   **Right:** Four blocks stacked vertically, each labeled 'SFP+ connector'\n\n**Connections:**\n*   **Between 'OCP type C connector' and 'PHY C827':** Five double-headed arrows labeled 'KR P/N TX0', 'KR P/N TX1', 'KR P/N TX2', 'KR P/N TX3', and 'MDC/MDIO'.\n*   **Between 'I2C MUX PCA9546AD' and 'OCP type C connector':** A single line labeled 'I2C' with an arrowhead pointing toward the 'OCP type C connector'.\n*   **Between 'PHY C827' and the 'SFP+ connector' blocks:** Four separate double-headed arrows, each labeled 'SFI', connecting the PHY block to each of the four 'SFP+ connector' blocks.\n*   **Between 'I2C MUX PCA9546AD' and the 'SFP+ connector' blocks:** A horizontal line connects the MUX block to a vertical dashed line that links the four 'SFP+ connector' blocks together.](.prod-spec-cei-4x10g-sfp-card-79024-user-manual/9bcf8da7c3a8460e7f56c391fb6d6e4978e787b43197e34356a19a09e8141ee6.jpg)

Figure 1 – CEI-4x10G-SFP+ function diagram

# 4. Pinout and Signal Descriptions

# 4.1. Input Interface Definitions

The table below is a comprehensible list of all signal pins supported on the 64-pin OCP connector of CEI-4x10G-SFP+ Card. The signal naming follow the PICMG COM-HPC Rev 1.0 Server Type specification. Signals described in the specification but not supported on the CEI-4x10G-SFP+ Card are strikethrough.

![Close-up of a green printed circuit board with gold connectors and a beige connector (no readable text or symbols)](.prod-spec-cei-4x10g-sfp-card-79024-user-manual/1e2f437f466fd6841ce9181afacd3d4f205a47695cec2d22f09b5807605e00da.jpg)

Table 1: CEI-4x10G-SFP+ Card Pin Definitions

<table><tr><td>Pin</td><td>Name</td><td>Pin</td><td>Name</td></tr><tr><td>33</td><td>+12V</td><td>1</td><td>MEZZC_SMCLK</td></tr><tr><td>34</td><td>+12V</td><td>2</td><td>MEZZC_SMDATA</td></tr><tr><td>35</td><td>+12V</td><td>3</td><td>MEZZC_EXT_MDIO_I2C_SEL_OU</td></tr><tr><td>36</td><td>MEZZC_RSVD1</td><td>4</td><td>GND</td></tr><tr><td>37</td><td>R_ETH_SDP0</td><td>5</td><td>MEZZC_TX_P_ETH2</td></tr><tr><td>38</td><td>R_ETH_SDP1</td><td>6</td><td>MEZZC_TX_N_ETH2</td></tr><tr><td>39</td><td>GND</td><td>7</td><td>GND</td></tr><tr><td>40</td><td>MEZZC_TX_P_ETH0</td><td>8</td><td>MEZZC_LED_P1_0_N</td></tr><tr><td>41</td><td>MEZZC_TX_N_ETH0</td><td>9</td><td>MEZZC_LED_P1_1_N</td></tr><tr><td>42</td><td>GND</td><td>10</td><td>GND</td></tr><tr><td>43</td><td>MEZZC_LED_P0_0_N</td><td>11</td><td>MEZZC_TX_P_ETH3</td></tr><tr><td>44</td><td>MEZZC_LED_P0_1_N</td><td>12</td><td>MEZZC_TX_N_ETH3</td></tr><tr><td>45</td><td>GND</td><td>13</td><td>GND</td></tr><tr><td>46</td><td>MEZZC_TX_P_ETH1</td><td>14</td><td>MEZZC_LED_P2_0_N</td></tr><tr><td>47</td><td>MEZZC_TX_N_ETH1</td><td>15</td><td>MEZZC_LED_P2_1_N</td></tr><tr><td>48</td><td>GND</td><td>16</td><td>GND</td></tr><tr><td>49</td><td>ETH_CEI0_MDIO_CLK_R</td><td>17</td><td>OCP_RX_P_ETH2</td></tr><tr><td>50</td><td>ETH_CEI0_MDIO_DAT_R</td><td>18</td><td>OCP_RX_N_ETH2</td></tr><tr><td>51</td><td>GND</td><td>19</td><td>GND</td></tr><tr><td>52</td><td>OCP_RX_P_ETH0</td><td>20</td><td>MEZZ_SCL0</td></tr><tr><td>53</td><td>OCP_RX_N_ETH0</td><td>21</td><td>MEZZ_SDA0</td></tr><tr><td>54</td><td>GND</td><td>22</td><td>GND</td></tr><tr><td>55</td><td>MEZZC_LED_P3_0_N</td><td>23</td><td>OCP_RX_P_ETH3</td></tr><tr><td>56</td><td>MEZZC_LED_P3_1_N</td><td>24</td><td>OCP_RX_N_ETH3</td></tr><tr><td>57</td><td>GND</td><td>25</td><td>GND</td></tr><tr><td>58</td><td>OCP_RX_P_ETH1</td><td>26</td><td>MEZZ_SCL1</td></tr><tr><td>59</td><td>OCP_RX_N_ETH1</td><td>27</td><td>MEZZ_SDA1</td></tr><tr><td>60</td><td>GND</td><td>28</td><td>GND</td></tr><tr><td>61</td><td>MEZZ_SCL2</td><td>29</td><td>MEZZ_SCL3</td></tr><tr><td>62</td><td>MEZZ_SDA2</td><td>30</td><td>MEZZ_SDA3</td></tr><tr><td>63</td><td>GND</td><td>31</td><td>R_ETH_SDP2</td></tr><tr><td>64</td><td>MEZZC_PRSNTC_N</td><td>32</td><td>R_ETH_SDP3</td></tr></table>

# 5. Module Interfaces and Configuration

This chapter describes connectors, LEDs and switches that are used on the 10GbE adaptor card. The locations of these items is as below:

# 5.1. Connector and LED Locations

![1x OCP Connector\n4x SFP+ Connectors](.prod-spec-cei-4x10g-sfp-card-79024-user-manual/b9a61978348863c15074407017d6803c413efdbe15a82f9e167ee2e1eae018e0.jpg)

Figure 2 – Module feature locations

# 5.2. LED Indicators

There are two status LEDs for each 10GSFP+ port

![Speed\nLink / Active Status](.prod-spec-cei-4x10g-sfp-card-79024-user-manual/5a01040f4815ad82722a2698e43595cdbaab4c2b1928181bcddb9425334542e0.jpg)

<table><tr><td>Function</td><td>LED Color</td><td>LED State</td><td>Description</td></tr><tr><td colspan="4"></td></tr><tr><td rowspan="3">Speed</td><td rowspan="3">Green / Yellow</td><td>Off</td><td>TBC</td></tr><tr><td>Yellow</td><td>1 Gbps link speed</td></tr><tr><td>Green</td><td>10 Gbps link speed</td></tr><tr><td rowspan="3">Link / Active Status</td><td rowspan="3">Green</td><td>Off</td><td>No Link</td></tr><tr><td>Steady On</td><td>Link established, no activity detected</td></tr><tr><td>Blinking</td><td>Link established, activity detected</td></tr></table>

# 5.3. 10GbE Adaptor Card Installation

Below is an example of a 10GbE adapter card installed on the COM-HPC Server carrier board with a COM-HPC-sIDH Module (or illustration purposes only).

![Close-up of a black computer motherboard with visible CPU socket, RAM slots, and various electronic components (no readable text or symbols)](.prod-spec-cei-4x10g-sfp-card-79024-user-manual/340d069ad09200d91d9c21c9aff8f5bc03f324d34aa82c0450f4b1221685be91.jpg)

Note: a specific cable and connection will be required if input 5VSB to 10GbE adaptor card is needed for the testing purpose, please contact local ADLINK representative for detail

# 6. Mechanical

![11.40\n10.09\n2.99\n0\n1.60\n9.30](.prod-spec-cei-4x10g-sfp-card-79024-user-manual/6ecd94af2e77fff33bbb688d5b0dde9ce4c78764e58936a2b8df4f6b4daa456c.jpg)

![0\n9.20\n15.53\n46.05\n49.69\n60.55\n77.98\n103.05\n110.05\n3\n4x Ø 3.30\n43.82\n64.80\n67.60\n28.20\n38.05\n103.05\n2x Ø 3.30\n71](.prod-spec-cei-4x10g-sfp-card-79024-user-manual/6fbecf433b7299a8788e29a8bb8686cfc19f1efec6d7e78da8e612060bfa186e.jpg)

All dimensions are shown in millimeters. Tolerances should be ± 0.25mm, unless otherwise noted.